Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “absolute”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

SORCE and TSIS-1 SIM Comparison: Absolute Irradiance Scale Reconciliation

The Solar Radiation and Climate Experiment (SORCE) and Total and Spectral Irradiance Sensor (TSIS-1) conducted an intercomparison for the two Spectral Irradiance Monitors (SIM) spanning 704 days from 23 March 2018 to 25 February 2020 and permitted 554 time-matched pairs of observations. This comparison was conducted during the extremely quiescent Solar Cycle 24 minimum, so all observed differences and drifts between the two sensors are instrumental in nature. The TSIS-1 SIM benefitted from advanced calibration capabilities based on SI standards that were not available during the preflight calibration time period of SORCE. For this reason, a revision of the SORCE SIM absolute scale is appropriate. As expected, wavelength dependent differences in absolute agreement are a function of detector sensitivity and local changes in spectral slope. At the time of the comparison SORCE SIM has been on-orbit for 17 years while TSIS-1 observations commenced immediately after a 100-day outgassing and commissioning period. Peak-to-peak absolute scale differences are about 12% with a mean fractional difference of 0.7% ± 2.9%. The greatest scale differences occur at the change-over between the UV and visible photodiodes in the 310 nm region, and a systematic disagreement is present in the 850–1,600 nm range. A multiplicative scale correction factor has been developed to reconcile the TSIS-1 and SORCE difference with a wavelength dependent error on the mean typically less than 0.01% derived from every matched pair of observations.

Jerald Harder↗

Absolute Distance Measurement with the MSTAR Sensor

The MSTAR sensor (Modulation Sideband Technology for Absolute Ranging) is a new system for measuring absolute distance, capable of resolving the integer cycle ambiguity of standard interferometers, and making it possible to measure distance with sub-nanometer accuracy. The sensor uses a single laser in conjunction with fast phase modulators and low frequency detectors. We describe the design of the system - the principle of operation, the metrology source, beamlaunching optics, and signal processing - and show results for target distances up to 1 meter. We then demonstrate how the system can be scaled to kilometer-scale distances.

modulation sideband technology for absolute rangin↗

Determination of the absolute contours of optical flats

Emersons procedure is used to determine true absolute contours of optical flats. Absolute contours of standard flats are determined and a comparison is then made between standard and unknown flats. Contour differences are determined by deviation of Fizeau fringe.

Primak, W.↗

Singular perturbation of absolute stability.

The influence of a small parameter at the higher derivatives in the differential equations describing nonlinear systems of the Lur'e-Postnikov class on absolute stability in the parameter space is investigated. The conditions leading to singular perturbations of absolute stability are examined.

Siljak, D. D.↗

A recalibration of the absolute magnitudes of supergiants.

Since luminosities of the supergiants are obtained most accurately by the group membership method, the study employed distance moduli of stellar groups that were determined from the magnitudes of the B-type main sequence stars using an extinction ratio of 3.0. For the supergiants, this ratio was taken to be a function of the spectral type following Schmidt-Kaler (1965) and Lee (1970). Supergiant data used in the construction of mean absolute magnitudes are discussed. In contrast to previous calibrations, no significant trend of visual absolute magnitude within a spectral subclass was found for the supergiants. Significant differences in some MK classes were observed between the results presented and the results of Blaauw and Schmidt-Kaler.

Stothers, R.↗

Singular perturbation of absolute stability.

It was previously shown (author, 1969) that the regions of absolute stability in the parameter space can be determined when the parameters appear on the right-hand side of the system equations, i.e., the regular case. Here, the effect on absolute stability of a small parameter attached to higher derivatives in the equations (the singular case) is studied. The Lur'e-Postnikov class of nonlinear systems is considered.

Siljak, D. D.↗

Experimental comparisons of the international pyrheliometric scale with the absolute radiation scale.

Solar irradiance measurements by instruments (Eppley Angstrom Pyrheliometers) reproducing the International Pyrheliometric Scale (IPS) have been compared with measurements made simultaneously by a number of JPL Active Cavity Radiometers (ACR) and the Practical Absolute Cavity Radiometer (PACRAD). The results of these tests demonstrate a systematic difference between the absolute radiation scale as defined by the ACR and PACRAD measurements and the IPS.

Willson, R. C.↗

Absolute intensity and polarization of rotational Raman scattering from N2, O2, and CO2

An experimental examination of the absolute intensity, polarization, and relative line intensities of rotational Raman scattering (RRS) from N2, O2, and CO2 is reported. The absolute scattering intensity for N2 is characterized by its differential cross section for backscattering of incident light at 647.1 nm, which is calculated from basic measured values. The ratio of the corresponding cross section for O2 to that for N2 is 2.50 plus or minus 5 percent. The intensity recent for N2, O2, and CO2 are shown to compare favorably to values calculated from recent measurements of the depolarization of Rayleigh scattering plus RRS. Measured depolarizations of various RRS lines agree to within a few percent with the theoretical value of 3/4. Detailed error analyses are presented for intensity and depolarization measurements. Finally, extensive RRS spectra at nominal gas temperatures of 23 C, 75 C, and 125 C are presented and shown to compare favorably to theoretical predictions.

Penney, C. M.↗

Absolute photon-flux measurements in the vacuum ultraviolet

Absolute photon-flux measurements in the vacuum ultraviolet have extended to short wavelengths by use of rare-gas ionization chambers. The technique involves the measurement of the ion current as a function of the gas pressure in the ion chamber. The true value of the ion current, and hence the absolute photon flux, is obtained by extrapolating the ion current to zero gas pressure. Examples are given at 162 and 266 A. The short-wavelength limit is determined only by the sensitivity of the current-measuring apparatus and by present knowledge of the photoionization processes that occur in the rate gases.

Samson, J. A. R.↗

Absolute flux measurements in the rocket ultraviolet

A two-channel spectrometer was calibrated in the wavelength region 1200-3400 A and flown on an Aerobee rocket to observe the stars alpha Lyr, eta UMa, and zeta Oph. Standard tungsten lamps provided the absolute calibration down to 2250 A, and a photodiode calibrated by the National Bureau of Standards was the reference at shorter wavelengths. The molecular branching-ratio technique of relative calibration using the gases CO, NO, and N2 was a check on the absolute calibration. The flux from eta UMa agrees with the prediction of a hydrogen line blanketed model atmosphere within 10% between 1700 and 3400 A and within 4% over most of this wavelength region.

Bohlin, R. C.↗

An S-band radiometer design with high absolute precision

A radiometer for the remote measurement of sea surface temperature is described. The development of an instrument capable not only of high relative accuracy (i.e., resolution) but also of high absolute precision is considered. The concepts underlying the design of an instrument capable of an absolute accuracy of a few tenths degrees Kelvin in the measurement of brightness temperature at S band are described. The role of the antenna is discussed, and the importance of high ohmic and beam efficiencies is stressed. The hardware itself is fully described, along with an outline concerning the design of a unique cryogenically cooled termination used to calibrate the whole radiometer, including antenna. Finally, some test results are presented that show that the design goals for the instrument have been closely approached.

Hardy, W. N.↗

Orbital elements and absolute dimensions of the eclipsing system LY Aurigae

Orbital solutions were obtained for the early-type eclipsing binary LY Aurigae from the light curves obtained with the OAO-2 by Heap and from the V light curve obtained from ground-based observations by Mayer and Horak. The solutions take into account the existence of a nearby companion not accounted for by previous investigators. The spectroscopic observations by Mayer and Batten were used to compute absolute dimensions for the binary orbit and for each component. This binary system presents an unique opportunity to determine accurately the absolute dimensions of an O9.5 III star.

Mccluskey, G. E., Jr.↗

Absolute line strengths for carbon and sulfur

Work has been conducted to reduce substantially uncertainties concerning the line strengths for carbon and sulfur. Two or more independent methods were used to measure thermodynamic variables and to calibrate detectors for absolute sensitivity and spectral response. The absolute transition probabilities of 124 visible and infrared lines of C I, S I, and S II were measured in a consistent way.

Miller, M. H.↗

Absolute plate motions by boundary velocity minimizations

The main interaction of the earth's interior with the lithosphere is as a material source and sink. An absolute reference frame defined by minimizing the translational motion of tectonic plate boundaries differs by 0.6 cm/year from a frame defined by hot spot traces and by 0.4 cm/year from the frame defined by the most plausible model of drag forces on the plates. The rms absolute translational velocities are about 2 cm/year for ocean-ocean plate boundaries and 1.5 cm/year for ocean-continent plate boundaries. The close agreement between the source and sink and the drag-dependent definitions suggests that the lithosphere, as a stress guide, to some extent controls the locations of its sources and sinks.

Kaula, W. M.↗

The absolute concentration of O/3P/ in the earth's stratosphere

Results are presented for an experimental application of the laminar flow-through/resonance technique, which allows direct observations of the absolute concentration of atoms and radicals in the earth's upper atmosphere. Atomic resonance fluorescence was used in conjunction with a parachute-borne flow-through module deployed from a balloon at a height of 40 km to determine the concentration of ground-state atomic oxygen at 40 to 25 km in the atmosphere. The equipment is described, and the measurements and experimental uncertainties are plotted. It is shown that the observed absolute concentration of ground-state atomic oxygen is similar to that predicted by model calculations, and it is concluded that this technique provides a simple and direct means of measuring atomic and radical concentrations in the part-per-trillion range in unperturbed stratospheric samples.

Anderson, J. G.↗

Absolute radiometry and the solar constant

A series of active cavity radiometers (ACRs) are described which have been developed as standard detectors for the accurate measurement of irradiance in absolute units. It is noted that the ACR is an electrical substitution calorimeter, is designed for automatic remote operation in any environment, and can make irradiance measurements in the range from low-level IR fluxes up to 30 solar constants with small absolute uncertainty. The instrument operates in a differential mode by chopping the radiant flux to be measured at a slow rate, and irradiance is determined from two electrical power measurements together with the instrumental constant. Results are reported for measurements of the solar constant with two types of ACRs. The more accurate measurement yielded a value of 136.6 plus or minus 0.7 mW/sq cm (1.958 plus or minus 0.010 cal/sq cm per min).

Willson, R. C.↗