Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ablator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Development of the C{sup 6+} laser ablation ion source for the KEK digital accelerator

A laser ion source that provides a fully ionized carbon ion beam is under joint development at the High Energy Accelerator Research Organization and Brookhaven National Laboratory. Long-pulse (6 ns) and short-pulse (500 ps) laser systems were tested by using them to irradiate a graphite target. Notable differences between the systems were observed in these experiments. Preliminary experimental results, such as the charge-state spectrum, beam intensity, and stability, are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-density carbon ablator ignition path with low-density gas-filled rugby hohlraum

A recent low gas-fill density (0.6 mg/cc 4 He) cylindrical hohlraum experiment on the National Ignition Facility has shown high laser-coupling efficiency (>96%), reduced phenomenological laser drive corrections, and improved high-density carbon capsule implosion symmetry [Jones et al., Bull. Am. Phys. Soc. 59(15), 66 (2014)]. In this Letter, an ignition design using a large rugby-shaped hohlraum [Amendt et al., Phys. Plasmas 21, 112703 (2014)] for high energetics efficiency and symmetry control with the same low gas-fill density (0.6 mg/cc 4 He) is developed as a potentially robust platform for demonstrating thermonuclear burn. The companion high-density carbon capsule for this hohlraum design is driven by an adiabat-shaped [Betti et al., Phys. Plasmas 9, 2277 (2002)] 4-shock drive profile for robust high gain (>10) 1-D ignition performance and large margin to 2-D perturbation growth.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron temperature and electron number density measurements in laser ablation Z-pinch experiments of Al2O3

Aluminum oxide (Al2O3) plasma was generated using the Ti:Sapphire/Nd:glass laser and Z-pinch pulse-power generator at the University of Nevada, Reno, Nevada Terawatt Facility. To determine the electron temperature, we use the Boltzmann plot method for the transitions (Al III 4d 2D3/2 → 4p 2P1/2) at 451.2564 nm, (Al III 4d 2D5/2 → 4p 2P3/2) at 452.9194 nm, (Al III 4p 2P3/2 → 4s 2S1/2) at 569.6603, and (Al III 4p 2P1/2 → 4s 2S1/2) at 572.2728 nm. Simultaneously, Mach–Zehnder laser interferometry was used to measure the electron number density. We compared simulated spectra obtained from PrismSPECT with electron number density and temperature measurements, and the electron temperature was found to range from 1.8 to 2.8 eV, while the electron number density was found to range from 2.3 × 1017 to 6.9 × 1017 cm−3 early in the pinched plasma formation.

Dutra, E. C.↗

Laser ablation spectrometry for studies of uranium plasmas, reactor monitoring, and spent fuel safety

Nuclear security is one of the defining challenges of our time. Nuclear threats range from deliberate dispersal of radioactive material to contaminate the vital infrastructure to diversion and smuggling of special nuclear material for clandestine nuclear programs and nuclear terrorism, respectively. There is an associated need to develop and sustain the nuclear forensics capabilities, which requires the understanding of complex processes that occur in plasmas of nuclear materials. The area of nuclear safety has seen a resurgence of public interest, and there is a concomitant need to safely store used nuclear fuel and detect structural material failure in nuclear power systems, especially in innovative reactor designs envisioned for future adoption. Laser-produced plasmas are complicated extreme environments that can generate intense and rich, highly specific signatures of nuclear and radiological materials, which can then be explored in a wide range of applications. They include interdiction and rapid detection of nuclear materials, including their isotopic composition, detection over long distances, laboratory simulation of weapons effects, monitoring the condition of structural materials in dry cask storage containers, and novel instrumentation for nuclear power systems. We present a compilation of recent representative examples of the application of laser spectroscopy, and laser-induced breakdown spectroscopy in particular, to nuclear safety and security problems. A case is made that spectroscopic techniques based on laser-produced plasmas offer complementary, and sometimes unique, capabilities that motivate the continued exploration of their efficient production and understanding of the signatures they produce

(020.3260) Isotope shifts, (140.3440) Laser-induce↗

The Hugoniot and chemistry of ablator plastic below 100 GPa

The equation of state of glow discharge polymer (GDP) was measured to high precision using the two-stage light gas gun at Lawrence Livermore National Laboratory at pressures up to 70 GPa. Both absolute measurements and impedance matching techniques were used to determine the principal and secondary Hugoniots. GDP likely reacts at about 30 GPa, demonstrated by specific emission at 450 nm coupled with changes to the Hugoniot and reshock points. As a result of these reactions, the shock pressure in GDP evolves in time, leading to a possible decrease in pressure as compression increases, or negative compressibility, and causing complex pressure profiles within the plastic. Velocity wave profile variation was observed as a function of position on each shot, suggesting some internal variation of GDP may be present, which would be consistent with previous observations. The complex temporal and possibly structural evolution of GDP under shock compression suggests that calculations of compression and pressure based upon bulk or mean measurements may lead to artificially low pressures and high compressions. Evidence for this includes a large shift in calculating reshock pressures based on the reflected Hugoniot. These changes also suggest other degradation mechanisms for inertial confinement fusion implosions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ablators - From Apollo to Future Missions to Moon, Mars and Beyond

Apollo was designed to carry astronauts safely back from the Moon at return speeds exceeding 11 km/s and requireddevelopment of a new ablative thermal protection system (TPS) to protect the capsule from entry heating. Mercuryand Gemini, that preceded Apollo, were focused on Earth orbiting system demonstration and lessons learned fromthem were used in Apollo. The ablative material and associated system development for Lunar return conditionsrequired considerable ground and flight testing. Mars Viking Lander missions required a new lighter weight ablatoras entry heating was benign compared to Apollo. Pioneer-Venus and Galileo Probe missions required a new and morecapable ablator than Apollo. After two decades, Mars Pathfinder followed by Mars Exploration Rover missions,smaller than Viking but more demanding, were able to use Viking ablative TPS. At the same time, advances in manufacturing and materials technology led to development of innovative lightweight ablators. These new ablators enabled Stardust and Genesis Sample Return Missions. Around the turn of this century, NASA decided on a scaled-upversion of the Apollo capsule for human exploration of Moon and Mars and the ablative heat shield to protect the CrewExploration Vehicle ended up being the Apollo ablative TPS. The Artemis 1 mission is currently fitted with tiledsystem, different than Orion EFT-1 but with the Apollo ablative material as a result of lessons learned. NASA iscurrently planning on sample return missions from Mars, and this will require robust ablative TPS that can providehigher reliability than any other past mission. There are still unexplored high scientific value destinations in the solarsystem. In situ exploration of Uranus, Neptune, Saturn and sample return missions with return speed much higher thanStardust will require ablators capable of withstanding extreme entry that are also efficient. New ablative TPS havebeen developed in anticipation of these future missions. This paper is intended to tell the story of these ablators,illustrated through examples. We see the use of flight proven ablators was sometimes a risky proposition and newablators perceived to be higher risk have proved otherwise. The history of ablators illustrates the challenges eachmission had to address, either through the use of flight proven or new ablative TPS, to be successful.

Venkatapathy, Ethiraj↗

Relationship between LIBS Ablation and Pit Volume for Geologic Samples: Applications for in situ Absolute Geochronology

In planetary sciences, in situ absolute geochronology is a scientific and engineering challenge. Currently, the age of the Martian surface can only be determined by crater density counting. However this method has significant uncertainties and needs to be calibrated with absolute ages. We are developing an instrument to acquire in situ absolute geochronology based on the K‐Ar method. The protocol is based on the laser ablation of a rock by hundreds of laser pulses. Laser Induced Breakdown Spectroscopy (LIBS) gives the potassium content of the ablated material and a mass spectrometer (quadrupole or ion trap) measures the quantity of 40Ar released. In order to accurately measure the quantity of released 40Ar in cases where Ar is an atmospheric constituent (e.g., Mars), the sample is first put into a chamber under high vacuum. The 40Arquantity, the concentration of K and the estimation of the ablated mass are the parameters needed to give the age of the rocks. The main uncertainties with this method are directly linked to the measures of the mass (typically some μg) and of the concentration of K by LIBS (up to 10%). Because the ablated mass is small compared to the mass of the sample, and because material is redeposited onto the sample after ablation, it is not possible to directly measure the ablated mass. Our current protocol measures the ablated volume and estimates the sample density to calculate ablated mass. The precision and accuracy of this method may be improved by using knowledge of the sample's geologic properties to predict its response to laser ablation, i.e., understanding whether natural samples have a predictable relationship between laser energy deposited and resultant ablation volume. In contrast to most previous studies of laser ablation, theoretical equations are not highly applicable. The reasons are numerous, but the most important are: a) geologic rocks are complex, polymineralic materials; b) the conditions of ablation are unusual (for example, variable vacuum pressure), and c) the ablation is made with hundreds of successive laser pulses. In this work, we aim to understand the effects that occur on LIBS spectra when a homogeneous rock or a mineral is ablated under high vacuum. Understanding these effects is important to define best practices for LIBS measurements and may lead to improved measurement (or possibly prediction) of the ablated volume. We will describe our laboratory approach and first results, and discuss its utility for situ absolute geochronology campaigns.

Devismes, D.↗

A Novel CT to Cone-Beam CT Registration Method Enables Immediate Real-Time Intraprocedural Three-Dimensional Assessment of Ablative Treatments of Liver Malignancies

AimTo evaluate a novel contrast-enhanced cone-beam computed tomography (CE-CBCT) registration method for accurate immediate assessment of ablation outcomes.Materials and MethodsContrast-enhanced computed tomography (CECT) was registered with CE-CBCT by applying semiautomatic landmark registration followed by automatic affine and non-rigid registration to correct for respiratory phase differences and liver deformation. This scheme was retrospectively applied to 30 patients who underwent 38 percutaneous microwave liver ablations. Three datasets were obtained for each case: (1) conventional CECT scans 24 h before ablation, (2) intraprocedural CE-CBCT scans, and (3) CECT scans 24 h post-ablation. Using a five-point scale, two experienced radiologists qualitatively assessed registration quality, equivalence of CE-CBCT assessment of ablation outcome to 24 h post-ablation CECT, and perceived increase of confidence using the fusion method to CBCT alone. Additionally, residual post-ablation tumor volumes were measured at both CE-CBCT and 24 h CECT and compared to the pre-CECT.ResultsRegistration quality was high for both radiologists (R1: 4.3 ± 0.6, R2: 4.4 ± 0.5; p = 0.87). Comparisons between the registration of pre-ablation CECT with CE-CBCT versus post-ablation CECT regarding the position of the ablated area to the treated target (R1: 4.4 ± 0.6, R2: 4.6 ± 0.4) and treatment outcome (R1: 4.5 ± 0.5, R2: 4.6 ± 0.4) were equivalent (p > 0.35). Increased confidence was noted when using fusion (R1: 4.6 ± 0.4, R2: 4.6 ± 0.4; p = 0.84). Moreover, in 6 ablations (15.8%) the intraprocedural registered CBCT showed residual tumor precisely where identified on the 24 h post-ablation CECT.ConclusionsCombined CE-CBCT holds the potential to change the current workflow of mini-invasive cancer local treatments. Given earlier visual identification of residual tumor post-ablation, this includes potentially eliminating the need for some additional treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗