Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “YO”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

James Clerk Maxwell Telescope Spectral and Continuum Imaging of Hyperactive Comet 46P/Wirtanen

The Jupiter-family comet (JFC) 46P/Wirtanen passed the Earth at a distance of 0.077 au on 2018 December 16 UT, presenting a rare opportunity to study the chemical structure of its coma. With the James Clerk Maxwell Telescope we achieved a resolution of 800 km, which is smaller than the scale lengths of some distributed cometary molecules at the comet's heliocentric distance of 1 au. Spectroscopic observations of the J = 4 − 3 transition of HCN showed generally uniform levels of outgassing activity during the observing period, 2018 December 14–20. Gas expansion velocities were ~0.6 km s−1, and the derived average HCN production rate was 7.4 × 1024 mol s−1. HCN and CH3OH emissions were detected at least 30'' (1600 km) from the nucleus, and the abundances of these species were typical for a JFC. The radial distribution of CH3OH is consistent with an extended source of sublimation such as a population of icy grains—cometary halo ice primaries, or CHIPs—as has been invoked previously to explain hyperactivity in comets. The abundance of H2CO is normal if it is a daughter species. HNC and CO were not detected, but a sensitive nondetection of CS implies an unusually low CS:H2O ratio of <0.02%. The peak brightness of the 850 μm continuum emissions from icy coma dust particles of size ~1 mm fell from (52 ± 6) to (40 ± 3) mJy beam−1 through the week, while the size of the dust coma remained essentially constant, with dust extending to ~1000 km from the nucleus. The total mass of those particles was ~2 × 108 kg.

Ian M Coulson↗

Mitigation and Use of Biofilms in Space for the Benefit of Human Space Exploration

Biofilms are groups of cells of the same or different species living in communities. Such structures are usually attached to surfaces, and on Earth, they have been found in diverse and extreme environments. Such agglomerations have been described as recalcitrant or protective when facing adversity. In space systems, biofilms have been found on a multitude of hardware surfaces. Different studies have identified genetic changes that may impact human health. The insufficiency of consistent research may return inconclusive arguments as to what extent microgravity encourages virulence and how biofilms could exacerbate crewed spaceflight–especially ones to remote areas with a lack of resupply and service missions. However, biofilms are also beneficial to plant biology, and they may supply in metabolic pathways that produce useful organic and inorganic components to maintain life in other celestial bodies. There are expansive areas of research that look into biofilms in space and scientific recommendations that reflect on expanding the aerospace industry’s knowledge of biofilms, how to mitigate, or use them to the advantage of spaceflight.

Yo-ann Velez Justiniano↗

Microbial Food Safety in Space Production Systems

While traveling to deep space is difficult for many reasons, food is a crucial one. Round-trip Mars mission scenarios last 3 years, demanding food with a shelf-life of 5 years; this means that feeding human crew sustainably for long-duration missions beyond low Earth orbit (LEO) will ultimately lead to a paradigm shift away from the current Earth-based food production system, which depends upon storing and transporting prepackaged foods, and toward bio-regenerative production of food in space. Pharmaceuticals and nutritional supplements face similar challenges. Moreover, the methods we currently use to detect dangerous microbes in food require sample return to Earth, a situation not viable for deep-space missions. While the science behind generating foods and bioproducts is covered by other white papers, in this paper we discuss a crucial gap uniting all of them: how to ensure that such products are free of unwanted microbial contamination and safe for crew to consume. Because Earth-based food safety systems cannot be directly applied in space, safety assurance is currently a critical bottleneck in the space production of food and other bioproducts. Future sustainable deep-space missions will require NASA to devote more resources in the coming decade to understanding the biological and physical science principles underlying microbial food safety in space, and to developing efficient, reliable methods in this area.

microbiology↗

Nutrient Limitation Predisposes A Cultivate of Burkholderia Contaminans From the ISS Water Processor Assembly to Biofilm Formation Under Simulated Microgravity.

The International Space Station (ISS) Water Processor Assembly (WPA) experiences intermittent dormancy between water recycling events thus promoting biofilm formation within the system. In this work we aimed to gain a deeper understanding of the impact of nutrient limitation on bacterial growth and biofilm formation under microgravity in support of biofilm mitigation efforts in exploration water recovery systems. A representative species of bacteria that is commonly cultured from the ISS WPA was cultured in an WPA influent water ersatz formulation tailored for microbiology studies. Burkholderia contaminans was cultured under a simulated microgravity (SµG) treatment in a vertically rotating high-aspect rotating vessel (HARV), with a rotating control (R) in the horizontal plane at the determined optimal rpm of 15 along with a stationary (S) control. At different time points, the bacterial culture and ersatz were harvested for bacterial counts, transcriptomic and nutrient content analyses. Under the test conditions, the culture under SµG treatment consumed the essential nutrients faster than the R and S control cultures in the early stage of growth, thus approaching a nutrient limited growth condition earlier than the controls. The rapid uptake and subsequent depletion of essential nutrients was further illustrated in the transcriptomic response of the SµG culture when compared to the transcriptomic response of the R and S control conditions. The observed starvation response may serve as one element to explain a moderate enhancement of biofilm formation in the SµG treatment. One implication of this investigation is that biofilm mitigation in the ISS environment could be supported by ensuring a steady flow of water as a vehicle for essential nutrients within the WPA to avoid complete consumption which occurs in times of no flow lending to undesired biofilm formation.

Angie Diaz↗

CDC Bioreactor Configuration Method for Volume Level Control with Controlled Inlet and Outlet Flow

Environmental Control Life Support Systems and other microbiological biofilm studies often utilize small scale bioreactors. Among these options are the popular BioSurface CDC bioreactors, currently being utilized by Marshall Space Flight Center groups researching the impact of biofilms on life support systems. After a recent experimental regime, it was determined additional equipment could be added to augment the capabilities of the bioreactors. Previous research configurations such as ASTM E3161 – 18 relied on an outlet stream gravity draining from a side drain port located above sampling coupons. This limited applications to experimental conditions with a controlled inlet and uncontrolled outlet flow. With the introduction of a small single pole single throw (SPST) reed float switch, a peristaltic pump connected to the outlet drain and a chassis controller, the bioreactor is able to maintain a set level. The modification allows additional variables to be tested, including highly adjustable fill and flush cycles, bioreactor volume, draining and filling control. Once the configuration modifications were implemented through the installation of the new equipment, data was collected to ensure the stability of the level measurements. As the level control switch is a float switch, consideration was taken into account for effects of internal stirring speed, along with effects of inlet and outlet flow rate. Data presented in this study will illustrate the stability and effectiveness of the configuration changes in equipment made to the bioreactor. These configuration changes are proving an effective control method to conduct biofilm mitigation techniques for ECLSS hardware research. The controlled level capabilities allow for a constant drip feed flow rate into the bioreactors, a key aspect of the biofilm mitigation testing.

CDC Bioreactor↗

Analysis of CDC Bioreactor Internal Thermal Measurements and Sample Coupon Temperatures

The CDC Biofilm Reactor is an integral laboratory tool for the Environmental Control and Life Support Systems (ECLSS) biofilm formation and growth research program. Critical to this research is the need to adjust and maintain various surface temperatures of the coupons housed within the CDC Biofilm Reactor. The purpose of this study was to provide quantitative temperature gradient information when the CDC Biofilm Reactor was operating according to several process scenarios. Two primary process parameters were evaluated. For the first set of test parameters, the liquid level was maintained at 350 mL, with an inlet flowrate of 0.1 mL/min, 1 mL/min, 10 mL/min. The liquid was allowed to gravity drain out of the outlet spout. For the second set of test parameters, the liquid level within the reactor was maintained at 550 mL, with an inlet flow of 0.1 mL/min, 1 mL/min, 10 mL/min and draining intermittently controlled to 0.8 mL/min to maintain the 550 mL level. Due to the placement of the thermocouple in the reactor, a difference in temperature occurred between the coupon surfaces and target biofilm reactor temperature when operated according to the first set of test parameters. When the reactor was operated according to the second set of parameters, which resulted in the thermocouple being submerged, the temperature gradient was eliminated. The results demonstrated minimal temperature gradient between the top and bottom coupon surfaces for coupons placed in a single rod within the CDC Biofilm Reactor for both sets of test parameters evaluated. The collection of this information helped to explain previous ECLSS biofilm formation test runs, along with providing guidance on best operating practices for future ECLSS experiments. The placement of the thermocouple also helps to explain the challenge of achieving and maintaining bulk liquid temperatures when biofilm is grown according to the standardized test methods.

CDC Bioreactor↗

CDC Bioreactor Configuration Method for Volume Level Control with Controlled Inlet and Outlet Flow

Environmental Control Life Support Systems and other microbiological biofilm studies often utilize small scale bioreactors. Among these options are the popular BioSurface CDC bioreactors, currently being utilized by Marshall Space Flight Center groups researching the impact of biofilms on life support systems. After a recent experimental regime, it was determined additional equipment could be added to augment the capabilities of the bioreactors. Previous research configurations such as ASTM E3161-21 relied on an outlet stream gravity draining from a side drain port located above sampling coupons. This limited applications to experimental conditions with a controlled inlet and uncontrolled outlet flow. With the introduction of a small single pole single throw (SPST) reed float switch and a peristaltic pump connected to the outlet drain and a chassis controller, the bioreactor is able to maintain a set level. The modification allows additional variables to be tested, including highly adjustable fill and flush cycles, bioreactor volume, draining and filling control. Once the configuration modifications were implemented through the installation of the new equipment, data was collected to ensure the stability of the level measurements. As the level control switch is a float switch, consideration was taken into account for effects of internal stirring speed, along with effects of inlet and outlet flow rate. Data presented in this study will illustrate the stability and effectiveness of the configuration changes in equipment made to the bioreactor. These configuration changes have demonstrated control method to conduct biofilm mitigation techniques for ECLSS hardware research. The controlled level capabilities allow for a constant drip feed flow rate into the bioreactors, a key aspect of the biofilm mitigation testing.

CDC Bioreactor↗

Genome Sequences of Bacteria Isolated from the International Space Station Water Systems

We report draft genomes of five bacteria recovered from the United States and Russian water systems onboard the International Space Station: bacteria of the genera Ralstonia, Burkholderia, Cupriavidus, Methylobacterium, and Pseudomonas. These sequences will help further the understanding of water reclamation and environmental control and life support systems in space.

Christian L. Castro↗

Development and Testing of a New Partial Gravity Urine Processor Design and Urine Pretreatment

The Planetary Urine Processor (PUP) is a urine distillation system for lunar or planetary applications, taking advantage of local gravity for phase separation as well as the movement and storage of waste feeds and distillate. The PUP utilizes a stationary evaporator with an integrated disposable bag to process urine and capture remaining precipitates. This system aims to increase water reclamation percentage to greater than 96%, reduce resource requirements, and enhance reliability and maintainability due to lower system complexity over the existing water recovery system on the International Space Station (ISS). This paper focuses on the hardware development, testing efforts, and the associated urine pretreatment development work.

Water Recovery↗

Analysis of CDC Bioreactor Internal Thermal Measurements and Sample Coupon Temperatures

The Center for Disease Control and Prevention (CDC) bioreactor is an integral laboratory tool for the Environmental Control and Life Support Systems (ECLSS) biofilm formation and growth research program. Critical to this research is the need to adjust and maintain various surface temperatures of the coupons housed within the CDC Bioreactor. The purpose of this study was to provide quantitative temperature gradient information when the CDC Bioreactor was operating according to several process scenarios. Two primary process parameters were evaluated. For the first set of test parameters, the liquid level was maintained at 350 mL, with an inlet flowrate of 0.1 mL/min, 1 mL/min, 10 mL/min. The liquid was allowed to gravity drain out of the outlet spout. For the second set of test parameters, the liquid level within the reactor was maintained at 550 mL, with an inlet flow of 0.1 mL/min, 1 mL/min, 10 mL/min and draining intermittently controlled to 0.8 mL/min to maintain the 550 mL level. Due to the placement of the thermocouple in the reactor, a difference in temperature occurred between the coupon surfaces and target Bioreactor temperature when operated according to the first set of test parameters. When the reactor was operated according to the second set of parameters, which resulted in the thermocouple being submerged, the temperature gradient was eliminated. The results demonstrated minimal temperature gradient between the top and bottom coupon surfaces for coupons placed in a single rod within the CDC Bioreactor for both sets of test parameters evaluated. The collection of this information helped to explain previous ECLSS biofilm formation test runs, along with providing guidance on best operating practices for future ECLSS experiments. The placement of the thermocouple also helps to explain the challenge of achieving and maintaining bulk liquid temperatures when biofilm is grown according to the standardized test methods.

CDC Bioreactor↗

CDC Bioreactor Configuration Method for Volume Level Control with Controlled Inlet and Outlet Flow

Environmental Control Life Support Systems and other microbiological biofilm studies often utilize small scale bioreactors. Among these options are the popular BioSurface CDC bioreactors, currently being utilized by Marshall Space Flight Center groups researching the impact of biofilms on life support systems. After a recent experimental regime, it was determined additional equipment could be added to augment the capabilities of the bioreactors. Previous research configurations such as ASTM E3161-21 relied on an outlet stream gravity draining from a side drain port located above sampling coupons. This limited applications to experimental conditions with a controlled inlet and uncontrolled outlet flow. With the introduction of a small single pole single throw (SPST) reed float switch and a peristaltic pump connected to the outlet drain and a chassis controller, the bioreactor is able to maintain a set level. The modification allows additional variables to be tested, including highly adjustable fill and flush cycles, bioreactor volume, draining and filling control. Once the configuration modifications were implemented through the installation of the new equipment, data was collected to ensure the stability of the level measurements. As the level control switch is a float switch, consideration was taken into account for effects of internal stirring speed, along with effects of inlet and outlet flow rate. Data presented in this study will illustrate the stability and effectiveness of the configuration changes in equipment made to the bioreactor. These configuration changes have demonstrated control method to conduct biofilm mitigation techniques for ECLSS hardware research. The controlled level capabilities allow for a constant drip feed flow rate into the bioreactors, a key aspect of the biofilm mitigation testing.

CDC Bioreactor↗

CDC Bioreactor Configuration Method for Volume Level Control with Controlled Inlet and Outlet Flow

Environmental Control Life Support Systems and other microbiological biofilm studies often utilize small scale bioreactors. Among these options are the popular BioSurface CDC bioreactors, currently being utilized by Marshall Space Flight Center groups researching the impact of biofilms on life support systems. After a recent experimental regime, it was determined additional equipment could be added to augment the capabilities of the bioreactors. Previous research configurations such as ASTM E3161-21 relied on an outlet stream gravity draining from a side drain port located above sampling coupons. This limited applications to experimental conditions with a controlled inlet and uncontrolled outlet flow. With the introduction of a small single pole single throw (SPST) reed float switch and a peristaltic pump connected to the outlet drain and a chassis controller, the bioreactor is able to maintain a set level. The modification allows additional variables to be tested, including highly adjustable fill and flush cycles, bioreactor volume, draining and filling control. Once the configuration modifications were implemented through the installation of the new equipment, data was collected to ensure the stability of the level measurements. As the level control switch is a float switch, consideration was taken into account for effects of internal stirring speed, along with effects of inlet and outlet flow rate. Data presented in this study will illustrate the stability and effectiveness of the configuration changes in equipment made to the bioreactor. These configuration changes have demonstrated control method to conduct biofilm mitigation techniques for ECLSS hardware research. The controlled level capabilities allow for a constant drip feed flow rate into the bioreactors, a key aspect of the biofilm mitigation testing.

CDC Bioreactor↗

Potential Biofilm Control Strategies for Extended Spaceflight Missions

Biofilms, surface-adherent microbial communities, are associated with microbial fouling and corrosion in terrestrial water-distribution systems. Biofilms are also present in human spaceflight, particularly in the Water Recovery System (WRS) on the International Space Station (ISS). The WRS is comprised of the Urine Processor Assembly (UPA) and the Water Processor Assembly (WPA) which together recycles wastewater from human urine and recovered humidity from the ISS atmosphere. These wastewaters and various process streams are continually inoculated with microorganisms primarily arising from the space crew microbiome. Biofilm-related fouling has been encountered and addressed in spacecraft in low Earth orbit, including ISS and the Russian Mir Space Station. However, planned future missions beyond low Earth orbit to the Moon and Mars present additional challenges, as resupplying spare parts or support materials would be impractical and the mission timeline would be in the order of years in the case of a mission to Mars. In addition, future missions are expected to include a period of dormancy in which the WRS would be unused for an extended duration. The concepts developed in this review arose from a workshop including NASA personnel and representatives with biofilm expertise from a wide range of industrial and academic backgrounds. Here, we address current strategies that are employed on Earth for biofilm control, including antifouling coatings and biocides and mechanisms for mitigating biofilm growth and damage. These ideas are presented in the context of their applicability to spaceflight and identify proposed new topics of biofilm control that need to be addressed in order to facilitate future extended, crewed, spaceflight missions.

Luis Zea↗

Development and Testing of a New Partial Gravity Urine Processor Design and Urine Pretreatment

The Planetary Urine Processor (PUP) is a urine distillation system for lunar or planetary applications, taking advantage of local gravity for phase separation as well as the movement and storage of waste feeds and distillate. The PUP utilizes a stationary evaporator with an integrated disposable bag to process urine and capture remaining precipitates. This system aims to increase water reclamation percentage to greater than 96%, reduce resource requirements, and enhance reliability and maintainability due to lower system complexity over the existing water recovery system on the International Space Station (ISS). This paper focuses on the hardware development, testing efforts, and the associated urine pretreatment development work.

Water Recovery↗

Update to Developing a Multi-bioreactor Test Stand for the Evaluation of Biofilm Mitigation Technologies

Biofilm formation in spacecraft wastewater systems is a complex and impactful problem. Biomass flowing in these wastewater systems can cause clogging, higher differential pressures, and flow restrictions impacting equipment reliability and function. To explore this issue, the Marshall Space Flight Center’s biofilm test stand was created and has been utilized to examine multiple biofilm mitigation techniques over a long duration test time. This paper is an update to a previous paper, ICES-2021-122, and will serve to discuss the modifications and enhancements to the biofilm test stand. While the previous configuration tested heat treatments and coatings, this phase of testing will examine differing materials, competing bacteria provided by an external bioreactor, a prototype phytoremediation unit, and additional testing with a nutrient filter. Configuration changes include the addition of float switches, adjustment of the drain assembly architecture and additional support hardware for the competing bacteria bioreactor and phytoremediation units.

ECLSS↗

Biofilm Mitigation Testing Phase III

Biofilm is produced from bacterial or fungal organisms that can survive in extreme conditions. The microorganisms attach themselves to surfaces and produce an extracellular polymeric matrix that develops into a community structure and ecosystem. Biofilm has been known to cause blockage and clogging inside the Water Processor Assembly (WPA) and Water Recovery System (WRS) piping. The WPA and WRS on the International Space Station (ISS) is responsible for recycling humidity condensate and urine distillate to produce potable water for the astronauts to survive. The Environmental Control and Life Support System (ECLSS) department is developing a way to mitigate biofilm accumulation inside the wastewater tank.

Biofilm↗