Fully depleted CMOS pixel sensor development and potential applications

CMOS pixel sensors are often opposed to hybrid pixel sensors due to their very different sensitive layer. In standard CMOS imaging processes, a thin (about 20 μm) low resistivity epitaxial layer acts as the sensitive volume and charge collection is mostly driven by thermal agitation. In contrast, the so-called hybrid pixel technology exploits a thick (typically 300 μm) silicon sensor with high resistivity allowing for the depletion of this volume, hence charges drift toward collecting electrodes. But this difference is fading away with the recent availability of some CMOS imaging processes based on a relatively thick (about 50 μm) high resistivity epitaxial layer which allows for full depletion. This evolution extents the range of applications for CMOS pixel sensors where their known assets, high sensitivity and granularity combined with embedded signal treatment, could potentially foster breakthrough in detection performances for specific scientific instruments. One such domain is the Xray detection for soft energies, typically below 10 keV, where the thin sensitive layer was previously severely impeding CMOS sensor usage. Another application becoming realistic for CMOS sensors, is the detection in environment with a high fluence of non-ionizing radiation, such as hadron colliders. However, when considering highly demanding applications, it is still to be proven that micro-circuits required to uniformly deplete the sensor at the pixel level, do not mitigate the sensitivity and efficiency required. Prototype sensors in two different technologies with resistivity higher than 1 kΩ, sensitive layer between 40 and 50 μm and featuring pixel pitch in the range 25 to 50 μm, have been designed and fabricated. Various biasing architectures were adopted to reach full depletion with only a few volts. Laboratory investigations with three types of sources (X-rays, β-rays and infrared light) demonstrated the validity of the approach with respect to depletion, keeping a low noise figure. Especially, an energy resolution of about 400 eV for 5 keV X-rays was obtained for single pixels. The prototypes have then been exposed to gradually increased fluences of neutrons, from 10{sup 13} to 5x10{sup 14} neq/cm{sup 2}. Again laboratory tests allowed to evaluate the signal over noise persistence on the different pixels implemented. Currently our development mostly targets the detection of soft X-rays, with the ambition to develop a pixel sensor matching counting rates as affordable with hybrid pixel sensors, but with an extended sensitivity to low energy and finer pixel about 25 x 25 μm{sup 2}. The original readout architecture proposed relies on a two tiers chip. The first tier consists of a sensor with a modest dynamic in order to insure low noise performances required by sensitivity. The interconnected second tier chip enhances the read-out speed by introducing massive parallelization. Performances reachable with this strategy combining counting and integration will be detailed. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diffractive Imaging of Conical Intersections Amplified by Resonant Infrared Fields

The fate of virtually all photochemical reactions is determined by conical intersections. These are energetically degenerate regions of molecular potential energy surfaces that strongly couple electronic states, thereby enabling fast relaxation channels. Their direct spectroscopic detection relies on weak features that are often buried beneath stronger, less interesting contributions. For azobenzene photoisomerization, a textbook photochemical reaction, we demonstrate how a resonant infrared field can be employed during the conical intersection passage to significantly enhance its coherence signatures in time-resolved Xray diffraction while leaving the product yield intact. Furthermore, this transition-state amplification holds promise to bring signals of conical intersections above the detection threshold.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Wide Field-of-View Soft X-Ray Imaging for Solar Wind-Magnetosphere Interactions

Soft X-ray imagers can be used to study the mesoscale and macroscale density structures that occur whenever and wherever the solar wind encounters neutral atoms at comets, the Moon, and both magnetized and unmagnetized planets. Charge exchange between high charge state solar wind ions and exospheric neutrals results in the isotropic emission of soft X-ray photons with energies from 0.1 to 2.0 keV. At Earth, this process occurs primarily within the magnetosheath and cusps. Through providing a global view, wide field-of-view imaging can determine the significance of the various proposed solar wind-magnetosphere interaction mechanisms by evaluating their global extent and occurrence patterns. A summary of wide field-of-view (several to tens of degrees) soft X-ray imaging is provided including slumped micropore microchannel reflectors, simulated images, and recent flight results.

xray↗

Automated X-ray and Optical Analysis of the Virtual Observatory and Grid Computing

We are developing a system to combine the Web Enabled Source Identification with X-Matching (WESIX) web service, which emphasizes source detection on optical images,with the XAssist program that automates the analysis of X-ray data. XAssist is continuously processing archival X-ray data in several pipelines. We have established a workflow in which FITS images and/or (in the case of X ray data) an X-ray field can be input to WESIX. Intelligent services return available data (if requested fields have been processed) or submit job requests to a queue to be performed asynchronously. These services will be available via web services (for non-interactive use by Virtual Observatory portals and applications) and through web applications (written in the Django web application framework). We are adding web services for specific XAssist functionality such as determining .the exposure and limiting flux for a given position on the sky and extracting spectra and images for a given region. We are improving the queuing system in XAssist to allow for "watch lists" to be specified by users, and when X-ray fields in a user's watch list become publicly available they will be automatically added to the queue. XAssist is being expanded to be used as a survey planning 1001 when coupled with simulation software, including functionality for NuStar, eRosita, IXO, and the Wide Field Xray Telescope (WFXT), as part of an end to end simulation/analysis system. We are also investigating the possibility of a dedicated iPhone/iPad app for querying pipeline data, requesting processing, and administrative job control.

Ptak, A.↗

Automated X-Ray Diffraction of Irradiated Materials

Synchrotron-based X-ray diffraction (XRD) and small-angle Xray scattering (SAXS) characterization techniques used on unirradiated and irradiated reactor pressure vessel steels yield large amounts of data. Machine learning techniques, including PCA, offer a novel method of analyzing and visualizing these large data sets in order to determine the effects of chemistry and irradiation conditions on the formation of radiation induced precipitates. In order to run analysis on these data sets, preprocessing must be carried out to convert the data to a usable format and mask the 2-D detector images to account for experimental variations. Once the data has been preprocessed, it can be organized and visualized using principal component analysis (PCA), multi-dimensional scaling, and k-means clustering. In conclusion, from these techniques, it is shown that sample chemistry has a notable effect on the formation of the radiation induced precipitates in reactor pressure vessel steels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three Dimensional Mapping of Nicle Oxidation States Using Full Field Xray Absorption Near Edge Structure Nanotomography

The reduction-oxidation cycling of the nickel-based oxides in composite solid oxide fuel cells and battery electrodes is directly related to cell performance. A greater understanding of nickel redox mechanisms at the microstructural level can be achieved in part using transmission x-ray microscopy (TXM) to explore material oxidation states. X-ray nanotomography combined with x-ray absorption near edge structure (XANES) spectroscopy has been applied to study samples containing distinct regions of nickel and nickel oxide (NiO) compositions. Digitally processed images obtained using TXM demonstrate the three-dimensional chemical mapping and microstructural distribution capabilities of full-field XANES nanotomography.

30 DIRECT ENERGY CONVERSION↗

X-ray structure determination using low-resolution electron microscopy maps for molecular replacement

Structures of multi-subunit macromolecular machines are primarily determined by either electron microscopy (EM) or X-ray crystallography. In many cases, a structure for a complex can be obtained at low resolution (at a coarse level of detail) with EM and at higher resolution (with finer detail) by X-ray crystallography. The integration of these two structural techniques is becoming increasingly important for generating atomic models of macromolecular complexes. A low-resolution EM image can be a powerful tool for obtaining the "phase" information that is missing from an X-ray crystallography experiment, however integration of EM and X-ray diffraction data has been technically challenging. Here we show a step-by-step protocol that explains how low-resolution EM maps can be placed in the crystallographic unit cell by molecular replacement, and how initial phases computed from the placed EM density are extended to high resolution by averaging maps over non-crystallographic symmetry. As the resolution gap between EM and Xray crystallography continues to narrow, the use of EM maps to help with X-ray crystal structure determination, as described in this protocol, will become increasingly effective.

59 BASIC BIOLOGICAL SCIENCES↗

Evidence of Radiosensitizing Effects of GdPO{sub 4} Nanostructures

Developing new methods to improve the outcome of cancer treatment has been one of the main research areas in medicine. Many approaches that allow for tumor targeting and thus reduction of side effects are currently under investigation. Among those, the combination of radiation therapy with certain chemotherapeutic agents has shown significant advances in cancer treatment. Another option is the use of radiosensitizers along with radiation therapy. Radiosensitizers are materials intended to enhance the radiation dose received in the tumor while maintaining the damage to the normal tissue to a minimum. Hence, the development of radiosensitizers has been of interest in recent years in order to improve the survival rate and the quality of life of the patient while reducing the cost of treatment. In this area, nanoparticles (NPs) have been widely explored as radiosensitizers due to the fact that tumor targeting can be achieved and the concentration of NPs on tumor environments can be greatly enhanced through the modification of NPs' surface by addition of agents such as antibodies. More importantly, the chemical composition of the NPs can be adjusted based on the application of interest. In this context, NPs that contain heavy elements have great potential as radiosensitizers due to their mechanisms of interaction with X-rays. For instance, gold NPs have been recognized as radiosensitizers due to their large photoelectric absorption coefficient. Furthermore, lanthanide based NPs have also shown characteristics as radiosensitizers. Among the various lanthanide containing NPs, gadolinium-based nanomaterials (NMs) have shown great potential for multiple applications in medicine such as contrast agents for magnetic resonance imaging (MRI). Additionally, the combination of gadolinium-based NPs and irradiation has evidenced a significant dose enhancement in in-vivo testing. Moreover, gadolinium-based ultra-small rigid platforms (USRPs) have shown theranostic properties for multimodal detection of lung cancers and radiosensitization effects. Among the various Gd based NPs, GdPO{sub 4} NMs are of increasing interest due to the multiple functions and applications that they may have. To illustrate, GdPO{sub 4} NPs have evidenced relaxitivities that are comparable to the contrast agents commonly used in MRI. Moreover, these NPs can be doped with different lanthanides ions allowing for the implementation of MRI and cellular luminescence for diagnostic purposes. Furthermore, gold-coated gadolinium-lanthanum phosphate NPs have evidenced their ability to encapsulate alpha-emitting radioisotopes of radiotherapeutic interest. This allows for targeted internal radiotherapy by functionalizing the NPs with specific molecules Moreover, low toxicity has been observed on dextran coated GdPO{sub 4} NPs regardless of the potential toxicity of free Gd{sup 3+}. Despite the various applications of GdPO{sub 4}, its response and interaction with X-ray evaluating their potential as radiosensitizers has not been explored. In this work, the radiosensitization of GdPO{sub 4} NMs is evidenced through the decomposition of a dye, methylene blue (MB), after X-ray radiation in the presence of NMs. GdPO{sub 4} was synthesized at moderate temperature following a hydrothermal method based on the precipitation reaction of a salt precursor and a surfactant. The crystalline structure and morphology of these NMs were characterized using Xray diffraction (XRD) and transmission electron microscopy (TEM). Crystalline GdPO{sub 4} was obtained following the hydrothermal synthesis. Besides, it was observed that the addition of GdPO{sub 4} to the MB solution enhances the decomposition of this dye under X-ray radiation. Therefore, GdPO{sub 4} NMs prove to be promising as radiosensitizers in radiation therapy. Nevertheless, the effect of GdPO{sub 4} on MB decomposition under X-ray radiation requires further study to evaluate the effect of the morphology and concentration of GdPO{sub 4} and the dose effect. (authors)

36 MATERIALS SCIENCE↗

Report on High-Contrast Advanced Radiographic Capability Review

The Advanced Radiographic Capability (ARC) project at the National Ignition Facility (NIF) is designed to generate picosecond duration, kilo-Joule laser pulses to produce xrays for backlighting NIF experiments. The baseline concept (Figure 1), utilizing a single NIF beam quad, diverts the beamline(s) using insertable pick-off mirrors to a compressor chamber in the target bay and focuses it to target chamber center. When fully implemented, ARC will use a quad of NIF beamlines to deliver eight Petawatt-class, high-intensity pulses in a split aperture configuration (2 short pulse apertures per NIF beamline). These short pulses will be adjustable in energy (up to 13.2 kJ in full implementation), delays (0-80 ns) and pulse durations (1-50 ps) and can be individually pointed to targets. ARC will enable dynamic, multi-frame x-ray imaging (radiography) on NIF for applications in laser driven fusion and other high-energy density science missions. The near-term missions in support of the SSP program are described below.

42 ENGINEERING↗

Feasibility of Amorphous Selenium Based Photon Counting Detectors for Digital Breast Tomosynthesis

Amorphous selenium (a-Se) has been incorporated successfully in direct conversion flat panel x-ray detectors, and has demonstrated superior image quality in screening mammography and digital breast tomosynthesis (DBT) under energy integration mode. The present work explores the potential of a-Se for photon counting detectors in DBT. We investigated major factors contributing to the variation in the charge collected by a pixel upon absorption of each x-ray photon. These factors included x-ray photon interaction, detector geometry, charge transport, and the pulse shaping and noise properties of the photon counting readout circuit. Experimental measurements were performed on a linear array test structure constructed by evaporating an a-Se layer onto an array of 100 {mu}m pitch strip electrodes, which are connected to a 32 channel low noise photon counting integrated circuit. The measured pulse height spectrum (PHS) under polychromatic xray exposure was interpreted quantitatively using the factors identified. Based on the understanding of a-Se photon counting performance, design parameters were proposed for a 2D detector with high quantum efficiency and count rate that could meet the requirements of photon counting detector for DBT.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray cavities in a sample of 83 SPT-selected clusters of galaxies: Tracing the evolution of AGN feedback in clusters of galaxies out to z = 1.2

X-ray cavities are key tracers of mechanical (or radio mode) heating arising from the active galactic nuclei (AGNs) in brightest cluster galaxies (BCGs). We report on a survey for X-ray cavities in 83 massive, high-redshift (0.4 7 Gyr at z∼0.8). On average, the detected X-ray cavities have powers of (0.8−5)×10{sup 45} erg s{sup −1}, enthalpies of (3−6)×10{sup 59} erg, and radii of ∼17 kpc. Integrating over 7 Gyr, we find that the supermassive black holes in BCGs may have accreted 10{sup 8} to several 10{sup 9} M{sub ⊙} of material to power these outflows. This level of accretion indicates that significant supermassive black hole growth may occur not only at early times, in the quasar era, but at late times as well. We also find that X-ray cavities at high redshift may inject an excess heat of 0.1–1.0 keV per particle into the hot ICM above and beyond the energy needed to offset cooling. Although this result needs to be confirmed, we note that the magnitude of excess heating is similar to the energy needed to preheat clusters, break self-similarity, and explain the excess entropy in hot atmospheres.

79 ASTRONOMY AND ASTROPHYSICS↗

Final Report on Developing Microstructure-Property Correlation in Reactor Materials using in situ High-Energy X-rays

This report provides a summary of research activities on understanding microstructure – property correlation in reactor materials using in situ high-energy X-rays. The report is a Level 2 deliverable in FY16 (M2CA-13-IL-AN_-0403-0111), under the Work Package CA-13-IL-AN_- 0403-01, “Microstructure-Property Correlation in Reactor Materials using in situ High Energy Xrays”, as part of the DOE-NE NEET Program. The objective of this project is to demonstrate the application of in situ high energy X-ray measurements of nuclear reactor materials under thermal-mechanical loading, to understand their microstructure-property relationships. The gained knowledge is expected to enable accurate predictions of mechanical performance of these materials subjected to extreme environments, and to further facilitate development of advanced reactor materials. The report provides detailed description of the in situ X-ray Radiated Materials (iRadMat) apparatus designed to interface with a servo-hydraulic load frame at beamline 1-ID at the Advanced Photon Source. This new capability allows in situ studies of radioactive specimens subject to thermal-mechanical loading using a suite of high-energy X-ray scattering and imaging techniques. We conducted several case studies using the iRadMat to obtain a better understanding of deformation and fracture mechanisms of irradiated materials. In situ X-ray measurements on neutron-irradiated pure metal and model alloy and several representative reactor materials, e.g. pure Fe, Fe-9Cr model alloy, 316 SS, HT-UPS, and duplex cast austenitic stainless steels (CASS) CF-8 were performed under tensile loading at temperatures of 20-400°C in vacuum. A combination of wide-angle X-ray scattering (WAXS), small-angle X-ray scattering (SAXS), and imaging techniques were utilized to interrogate microstructure at different length scales in real time while the specimen was subject to thermal-mechanical loading. In addition, in situ X-ray studies were complemented and benchmarked by ex situ characterization using advanced electron microscopy, atom probe tomography (APT) and micro/nano-indentation. The report presented in situ tensile test results on neutron-irradiated pure Fe, Fe-9Cr model alloy, 316 SS and CASS CF-8. These in situ experiments demonstrate the broad applications of the new capability in understanding several outstanding issues related to irradiated materials.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Practical Application of Synchrotron Based Hard Xray Micorprobes in Soil Sciences

Many of the most pressing questions in soil sciences require characterization of elemental abundances and speciation in minute samples that are heterogeneous at the submicrometer scale. This science addresses a wide gamut of environmental and health issues of high societal impact. Synchrotron radiation sources are ideal for developing high-intensity, highly focused X-ray probes and those that have been developed to deliver high-energy photons, so-called hard X-ray microprobes (HXRM), have had a major impact in advancing our understanding of the speciation, transport, and reactions of chemical species in soils. X-ray microprobe techniques offer distinct advantages over other analytical techniques by allowing analyses to be done in situ, an important example being the ability to determine chemical speciation of a wide variety of toxic elements in moist soils and biological specimens with little or no chemical pretreatment and low detection limits. In particular, coupled microfocused X-ray fluorescence, spectroscopy, and diffraction analysis allows one to quantify the abundance and speciation of elements in these materials at trace element concentrations and evaluate the mineralogy to which they are adsorbed or bound. Increasingly, these analyses are being done as imaging experiments not only in two dimensions but three dimensionally (3D) using tomographic techniques as well. Such information is crucial in understanding the toxicity, mobility, and containment of contaminating metals in the environment, mechanisms of trace element partitioning, and paths of strategic metal enrichment in nature.

54 ENVIRONMENTAL SCIENCES↗

Large Area Airborne Contamination Monitoring

Current D&D operations at Hanford have demonstrated a flaw in the current state of the art capability of defining airborne contamination boundaries. Airborne particulate emissions of Pu-239 from CM2H operations on the Hanford Pu Finishing Plant were detected well beyond areas controlled for airborne plutonium, putting numerous workers at risk for radiological assimilations. Forty-two Hanford workers had positive bioassay results for plutonium uptake. Work areas determined to be free of airborne contamination as measured by state-of-the-art continuous alpha monitoring (CAM) systems were later discovered not to be. Airborne contamination was scattered to a such degree that CAM systems were surveying insufficient volumes of air to accurately predict where respiratory protection was required. A $\$ 19,000$ state of the art portable CAM system used at both Hanford and at SRS screens air for alpha activity at the rate of 1 CFM. This research project will explore the feasibility of using commercially available air purifying systems to screen significantly larger volumes of air for airborne actinide contamination. Commercial household HEPA based air purifying units screen large volumes of air, a simple $\$ 300$ unit being looked at for this study could screen a volume of air that would require over 300 of the $\$ 19,000$ CAMs. The goal of the project was to determine the feasibility of building a detection system capable of screening the air purifiers pre-filters and HEPA filters for any actinide bearing hot particles that have been captured. The simplest technologies available to Field-Radiological-Protection personnel are hand-held alpha field survey meters. With the size and the corrugated structure of these HEPA filters, hand screening is not practical. This project researched alternatives capable of automating this function. Two potential technologies were examined. One technology evaluated was the measurement of xray emissions from the actinides, taking advantage of the higher emission rates of the L x-rays compared to the gamma emissions of isotopes such as Pu-238 or Pu-239. High resolution to low resolution systems were evaluated. Branching ratio data on the actinides in the literature is incomplete, and a study was initiated to measure branching ratios of the various L emissions of a number of the plutonium isotopes. A Monte Carlo simulation was also run to calculate the effect the attenuating HEPA media would have on x-ray measurements on spectrometers centered in each quadrant above the surface of the HEPA. The second technology evaluated was measuring the light from a scintillating media applied to the surface of the HEPA filter using a ThorLabs Scientific-Grade Digital Camera Model 8051M. A light tight enclosure capable of holding the 2’x2’x1” HEPA filter was fabricated. Numerous scintillation media were evaluated for both the sensitivity and for resolution of measuring alpha activity. Figure 1 shows images of a 4”x4” section of HEPA filter with a 3 x 3 grid of Pu-238 contamination loaded inside the crevices of the HEPA.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The MOCHII ISS National Laboratory: The First Spacecraft Based Scanning Electron Microscope

Introduction: Scanning electron microscopy (SEM) in concert with element identification by energy dispersive Xray (EDX) spectroscopy has become an indispensable tool in the analyses of extraterrestrial materials. Nevertheless, to-date, SEM-EDX instrumentation has remained purely in the purview of terrestrial laboratories due to their size, complexity, and operational requirements. However, in January 2022 a miniaturized SEM-EDX called MOCHII became the first successful space-based instrument of its kind, following its deployment onboard the International Space Station (ISS). It represents the culmination of nearly 40 years of technological development. We have performed an on-orbit study with MOCHII with the goal of evaluating its potential as the progenitor of a new generation of spacecraftbased instruments for use in future manned and robotic planetary exploration missions. Out goal has been to validate the on-orbit investigation of samples relevant to astromaterials and astrobiology. We have performed in-situ analyses on standards and a freshly fractured fragment of the Martian meteorite Allan Hills 84001 which was first analyzed, prior to launch, using an engineering MOCHII ground unit located at Johnson Space Center in Houston. Results of both imaging and compositional analyses substantiates the utility of remote SEM-EDX analyses in low Earth orbit (LEO).

Miniature Scanning Electron Microscope↗

SU-E-CAMPUS-I-01: Nanometric Organic Photovoltaic Thin Film X-Ray Detectors for Clinical KVp Beams

Purpose: To fabricate and test nanometric organic photovoltaic (OPV) cells made of various active-layer/electrode thicknesses and sizes; to determine the optimal material combinations and geometries suitable for dose measurements in clinical kilovoltage x-ray beams. Methods: The OPV consisted of P3HT:PCBM photoactive materials sandwiched between aluminum and Indium Tin Oxide (ITO) electrodes. Direct conversion of xrays in the active layer composed of donor and acceptor semiconducting organic materials generated signal in photovoltaic mode (without external voltage bias). OPV cells were fabricated with different active layer thicknesses (150, 270, 370 nm) and electrode areas (0.4, 0.7, 0.9, 1.4, 2.6 cm{sup 2}). A series of experiments were preformed in the energy range of 60–150 kVp. The net current per unit area (nA/cm{sup 2}) was measured using 200 mAs time-integrated beam current. Results: The net OPV current as function of beam energy (kVp) was proportional to ∼E{sup 0,4} {sup 5} when adjusted for beam output. The best combination of parameters for these cells was 270 nm active layer thicknesses for 0.7 cm{sup 2} electrode area. The measured current ranged from 0.69 to 2.43 nA/cm{sup 2} as a function of x-ray energy between 60 and 150 kVp, corresponding to 0.09 – 0.06 nA/cm{sup 2}/mGy, respectively, when adjusted for the beam output. Conclusion: The experiments indicate that OPV detectors possessing 270 nm active layer and 0.7 cm{sup 2} Al electrode areas have sensitivity by a factor of 2.5 greater than commercial aSi thin film PV. Because OPV can be made flexible and they do not require highvoltage bias supply, they open the possibility for using as in-vivo detectors in radiation safety in x-ray imaging beams.

60 APPLIED LIFE SCIENCES↗

In situ characterization of foreign object damage (FOD) in environmental-barrier-coated silicon carbide (SiC) ceramic

Environmental barrier coatings (EBCs) protect advanced ceramics and ceramic matrix composites (CMCs) from oxidation and corrosion in gas turbine engine environments. Foreign object damage (FOD), where debris impact the protective coatings, is a critical hazard which limits the turbine durability. Despite previous efforts to understand FOD in EBCs, a detailed understanding of the fundamental transient damage mechanisms is still lacking. In the current work, the real-time FOD behavior of a Mullite / Silicon EBC was visualized via a dynamic synchrotron X-ray source in phase contrast imaging (PCI) configuration. Prior to the in situ FOD experiments, the microstructure and composition of the coating were respectively characterized using a scanning electron microscope (SEM) and X-ray diffraction (XRD). The variation in the properties of the debris was modeled by ~ 1.5 mm diameter Partially Stabilized Zirconia (PSZ) and Silicon Nitride (Si 3 N 4 ) spheres. A modified light-gas gun setup, synchronized with the X-ray beam, was used to propel the projectiles at velocities ranging between 300 and 355 m·s -1 . Coated samples were impacted under a fully backed support configuration and at normal incidence. Coating penetration and delamination, as well as projectile deformation at the bond coat resulted for FOD by PSZ spheres. Comparatively, projectile fracture, with subsequent rebound of fragments, as well as complete coating penetration and delamination at the substrate interface occurred for FOD by Si 3 N 4 spheres. It should be noted that only cone cracking was observed for FOD by PSZ spheres while back surface cracking was present for both projectile types. Qualitative understanding of the driving forces for the observed damage mechanisms were provided.

36 MATERIALS SCIENCE↗

SU-E-T-132: Dosimetric Impact of Positioning Errors in Hypo-Fractionated Cranial Radiation Therapy Using Frameless Stereotactic BrainLAB System

Purpose: To determine dosimetric impact of positioning errors in the stereotactic hypo-fractionated treatment of intracranial lesions using 3Dtransaltional and 3D-rotational corrections (6D) frameless BrainLAB ExacTrac X-Ray system. Methods: 20 cranial lesions, treated in 3 or 5 fractions, were selected. An infrared (IR) optical positioning system was employed for initial patient setup followed by stereoscopic kV X-ray radiographs for position verification. 6D-translational and rotational shifts were determined to correct patient position. If these shifts were above tolerance (0.7 mm translational and 1° rotational), corrections were applied and another set of X-rays was taken to verify patient position. Dosimetric impact (D95, Dmin, Dmax, and Dmean of planning target volume (PTV) compared to original plans) of positioning errors for initial IR setup (XC: Xray Correction) and post-correction (XV: X-ray Verification) was determined in a treatment planning system using a method proposed by Yue et al. (Med. Phys. 33, 21-31 (2006)) with 3D-translational errors only and 6D-translational and rotational errors. Results: Absolute mean translational errors (±standard deviation) for total 92 fractions (XC/XV) were 0.79±0.88/0.19±0.15 mm (lateral), 1.66±1.71/0.18 ±0.16 mm (longitudinal), 1.95±1.18/0.15±0.14 mm (vertical) and rotational errors were 0.61±0.47/0.17±0.15° (pitch), 0.55±0.49/0.16±0.24° (roll), and 0.68±0.73/0.16±0.15° (yaw). The average changes (loss of coverage) in D95, Dmin, Dmax, and Dmean were 4.5±7.3/0.1±0.2%, 17.8±22.5/1.1±2.5%, 0.4±1.4/0.1±0.3%, and 0.9±1.7/0.0±0.1% using 6Dshifts and 3.1±5.5/0.0±0.1%, 14.2±20.3/0.8±1.7%, 0.0±1.2/0.1±0.3%, and 0.7±1.4/0.0±0.1% using 3D-translational shifts only. The setup corrections (XC-XV) improved the PTV coverage by 4.4±7.3% (D95) and 16.7±23.5% (Dmin) using 6D adjustment. Strong correlations were observed between translation errors and deviations in dose coverage for XC. Conclusion: The initial BrainLAB IR system based on rigidity of the mask-frame setup is not sufficient for accurate stereotactic positioning; however, with X-ray imageguidance sub-millimeter accuracy is achieved with negligible deviations in dose coverage. The angular corrections (mean angle summation=1.84°) are important and cause considerable deviations in dose coverage.

60 APPLIED LIFE SCIENCES↗