Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “XFELs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

X-ray Parametric Down Conversion at an XFEL

Understanding and harnessing X-ray quantum effects could open new frontiers in imaging and quantum optics. In this study, we measured the process of X-ray Parametric Down Conversion, where a single high-energy X-ray photon splits into two lower-energy photons. Using the SACLA X-ray Free Electron Laser in Japan at 9.83 keV, we found clear evidence that pairs of photons were produced along the energy-angle relationship that conserved both energy and momentum, as predicted for down-conversion, and consistent with quantum entanglement of X-ray photons. By matching specific photon pairs for energy and momentum conservation, we observe a signal rate of 1,250 pairs per hour, confirming that correlated photon pairs can be generated and observed in the absence of explicit time correlations. Our results show that with further refinement, the number of entangled photons produced per laser pulse could increase by an order of magnitude. This paves the way for demonstrating quantum-enhanced X-ray imaging, and confirmation of X-ray photon entanglement.

47 OTHER INSTRUMENTATION↗

NNSA Light Source Enhancements: Coupling a High Energy Laser Driver to an XFEL

NNSA has an unmet capability gap to predict how changes in material microstructure, due to aging and new manufacturing practices, can affect performance at extremes. This capability gap is the basis for the Dynamic Mesoscale Material Science Capability (DMMSC) CD-0 that was signed in 2015 [1]. Because of the delay to the MaRIE facility approach, the Tri-Lab in March 2020 proposed separate complementary investments at the APS and LCLS to address portions of the DMMSC mission need [2].

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Air attenuation of high power XFEL beams

The Linac Coherent Light Source-II, a high-repetition-rate x-ray free electron laser, produces high average power as well as high peak power. Air is a key radiation safety element, helping to contain the FEL beams from reaching accessible areas. At high average power, air absorption can produce a high temperature and low-density channel along the x-ray beam path. In this case, the x-ray attenuation no longer follows the Beer-Lambert equation, e-μx . Air attenuation measurements were performed with x-rays focused into a gas cell at the LCLS Time-resolved AMO instrument. The air transmission was observed to significantly increase with x-ray power. Simulations were also performed, which include the thermal processes related to the high average power. In comparison to the measurements, the calculated air transmission is higher, confirming that the simulations are conservative and suitable for radiation safety analyses.

42 ENGINEERING↗

An ultra-compact x-ray free-electron laser

In the field of beam physics, two frontier topics have taken center stage due to their potential to enable new approaches to discovery in a wide swath of science. These areas are: advanced, high gradient acceleration techniques, and x-ray free electron lasers (XFELs). Further, there is intense interest in the marriage of these two fields, with the goal of producing a very compact XFEL. In this context, recent advances in high gradient radio-frequency cryogenic copper structure research have opened the door to the use of surface electric fields between 250 and 500 MV m -1 . Such an approach is foreseen to enable a new generation of photoinjectors with six-dimensional beam brightness beyond the current state-of-the-art by well over an order of magnitude. This advance is an essential ingredient enabling an ultra-compact XFEL (UC-XFEL). In addition, one may accelerate these bright beams to GeV scale in less than 10 m. Such an injector, when combined with inverse free electron laser-based bunching techniques can produce multi-kA beams with unprecedented beam quality, quantified by 50 nm-rad normalized emittances. The emittance, we note, is the effective area in transverse phase space (x, p x /m e c) or (y, p y /m e c) occupied by the beam distribution, and it is relevant to achievable beam sizes as well as setting a limit on FEL wavelength. These beams, when injected into innovative, short-period (1–10 mm) undulators uniquely enable UC-XFELs having footprints consistent with university-scale laboratories. We describe the architecture and predicted performance of this novel light source, which promises photon production per pulse of a few percent of existing XFEL sources. We review implementation issues including collective beam effects, compact x-ray optics systems, and other relevant technical challenges. To illustrate the potential of such a light source to fundamentally change the current paradigm of XFELs with their limited access, we examine possible applications in biology, chemistry, materials, atomic physics, industry, and medicine—including the imaging of virus particles—which may profit from this new model of performing XFEL science.

47 OTHER INSTRUMENTATION↗

Development of spinning-disk solid sample delivery system for high-repetition rate x-ray free electron laser experiments

X-ray free-electron lasers (XFELs) deliver intense x-ray pulses that destroy the sample in a single shot by a Coulomb explosion. Experiments using XFEL pulse trains or the new generation of high-repetition rate XFELs require rapid sample replacement beyond those provided by the systems now used at low repletion-rate XFELs. We describe the development and characterization of a system based on a spinning disk to continuously deliver a solid sample into an XFEL interaction point at very high speeds. We tested our system at the Linac Coherent Light Source and European XFEL hard x-ray nano-focus instruments, employing it to deliver a 25 μm copper foil sample, which can be used as a gain medium for stimulated x-ray emission for the proposed x-ray laser oscillator.

47 OTHER INSTRUMENTATION↗

Prediction on X-ray output of free electron laser based on artificial neural networks

Abstract Knowledge of x-ray free electron lasers’ (XFELs) pulse characteristics delivered to a sample is crucial for ensuring high-quality x-rays for scientific experiments. XFELs’ self-amplified spontaneous emission process causes spatial and spectral variations in x-ray pulses entering a sample, which leads to measurement uncertainties for experiments relying on multiple XFEL pulses. Accurate in-situ measurements of x-ray wavefront and energy spectrum incident upon a sample poses challenges. Here we address this by developing a virtual diagnostics framework using an artificial neural network (ANN) to predict x-ray photon beam properties from electron beam properties. We recorded XFEL electron parameters while adjusting the accelerator’s configurations and measured the resulting x-ray wavefront and energy spectrum shot-to-shot. Training the ANN with this data enables effective prediction of single-shot or average x-ray beam output based on XFEL undulator and electron parameters. This demonstrates the potential of utilizing ANNs for virtual diagnostics linking XFEL electron and photon beam properties.

47 OTHER INSTRUMENTATION↗

Theory and Simulation of Ultrafast Multidimensional Nonlinear X-ray Spectroscopy of Molecules (Final Report)

Emerging X-ray free electron laser (XFEL) beam sources offer new types of probes of matter with unprecedented spatial and temporal resolutions. These experimental advances must be met by robust theoretical and computational tools that provide predictive modeling capacity of the underlining electronic and structural dynamics. The latter will be essential for the design of sophisticated multi-pulse experiments and for their interpretation. The proposed research effort will focus on developing cutting- edge simulation tools for nonlinear multidimensional X-ray/optical spectroscopies and aims to address key questions in Priority Research Opportunities 1 (Probing and controlling electron motion within a molecule) and 3 (Capturing rare events and intermediate states in the transformation of matter) as mentioned in the BES Roundtable Report “Opportunities for Basic Research at the Frontiers of XFEL Ultrafast Science”. XFEL multidimensional nonlinear techniques, which combine sequences of X-ray and possibly optical pulses, provide a unique experimental toolbox for probing the dynamics of core and valence electronic excitations, as well as material structure. Predictive modeling of these dynamical processes requires the combination of analytical theory for nonlinear interactions of light and matter, robust quantum-chemical methodologies for the accurate description of electronic structure of various materials, and multiscale ab initio electron and nuclear dynamics techniques operating beyond Born-Oppenheimer approximation. These challenges will be addressed with three research thrusts (i) Develop and implement theoretical apparatus for modeling a broad range of multidimensional spectroscopic techniques enabled by present and upcoming XFEL facilities. This thrust also includes the incorporation of a computational module in the DOE supported open-source NWChem computational chemistry package as well as the development of other open-source codes ready for dissemination across a broad user base; (ii) Propose and design new multi-pulse experiments that make use of the capabilities of the incoming LCLS-II facility; (iii) Perform selected applications to specific molecular systems that can be carried out at LCLS-II and demonstrate how these X-ray sources may be used to study nonadiabatic dynamics through conical interactions, electronic correlations in multi-core excitons, and charge transfer/energy transfer processes. The proposed research will be carried out by a multi-disciplinary four-institution research team which combines academia and national laboratories and spans the broad and necessary expertise in theoretical spectroscopy, nonlinear optics, quantum chemistry, molecular non-adiabatic dynamics and code development. The work will be performed in a highly interactive team environment with junior researchers shared between institutions thus cementing cross- disciplinary interactions. The developed simulation tools will be immediately deployed for XFEL facility users, both experimentalists and theorists, via freely distributed codes and databases. Altogether, this project will facilitate establishing XFEL-based multidimensional spectroscopies as a novel diagnostic tool for monitoring electronic and structural dynamics in molecular materials.

74 ATOMIC AND MOLECULAR PHYSICS↗

Emergence of pseudoresonance in high-intensity resonant inelastic x-ray scattering

We report resonant inelastic x-ray scattering (RIXS) spectra of neon atoms interacting with intense x-ray pulses generated using an x-ray free-electron laser (XFEL). We find that an unexpected peak emerges near the 𝐾⁢𝛼 line of Ne, which does not coincide with any physical resonances of neon ions. We perform theoretical calculations based on a quantum-state-resolved rate-equation approach with x-ray-induced processes including possible resonant excitations. Our dynamics simulations demonstrate that a sequence of multiple resonant photoabsorption events are involved and the interplay of those multiple resonances in combination with the relatively large spectral bandwidth of XFEL radiation leads to the emergent resonance-like structure at a position where no resonances exist. Our finding offers critical guidance for future applications of high-intensity RIXS at XFEL facilities.

74 ATOMIC AND MOLECULAR PHYSICS↗

Using X-ray free-electron lasers for spectroscopy of molecular catalysts and metalloenzymes

The metal centers in metalloenzymes and molecular catalysts are responsible for the rearrangement of atoms and electrons during complex chemical reactions, and they enable selective pathways of charge and spin transfer, bond breaking/making and the formation of new molecules. Mapping the electronic structural changes at the metal sites during the reactions gives a unique mechanistic insight that has been difficult to obtain to date. The development of X-ray free-electron lasers (XFELs) enables powerful new probes of electronic structure dynamics to advance our understanding of metalloenzymes. The ultrashort, intense and tunable XFEL pulses enable X-ray spectroscopic studies of metalloenzymes, molecular catalysts and chemical reactions, under functional conditions and in real time. In this Technical Review, we describe the current state of the art of X-ray spectroscopy studies at XFELs and highlight some new techniques currently under development. With more XFEL facilities starting operation and more in the planning or construction phase, new capabilities are expected, including high repetition rate, better XFEL pulse control and advanced instrumentation. For the first time, it will be possible to make real-time molecular movies of metalloenzymes and catalysts in solution, while chemical reactions are taking place.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Resolving Nonequilibrium Shape Variations among Millions of Gold Nanoparticles

Nanoparticles, exhibiting functionally relevant structural heterogeneity, are at the forefront of cutting-edge research. Now, high-throughput single-particle imaging (SPI) with X-ray free-electron lasers (XFELs) creates opportunities for recovering the shape distributions of millions of particles that exhibit functionally relevant structural heterogeneity. To realize this potential, three challenges have to be overcome: (1) simultaneous parametrization of structural variability in real and reciprocal spaces; (2) efficiently inferring the latent parameters of each SPI measurement; (3) scaling up comparisons between 10 5 structural models and 10 6 XFEL-SPI measurements. Here, we describe how we overcame these three challenges to resolve the nonequilibrium shape distributions within millions of gold nanoparticles imaged at the European XFEL. These shape distributions allowed us to quantify the degree of asymmetry in these particles, discover a relatively stable “shape envelope” among nanoparticles, discern finite-size effects related to shape-controlling surfactants, and extrapolate nanoparticles’ shapes to their idealized thermodynamic limit. Ultimately, these demonstrations show that XFEL SPI can help transform nanoparticle shape characterization from anecdotally interesting to statistically meaningful.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The ePix10k 2-megapixel hard X-ray detector at LCLS

The ePix10ka2M (ePix10k) is a new large area detector specifically developed for X-ray free-electron laser (XFEL) applications. The hybrid pixel detector was developed at SLAC to provide a hard X-ray area detector with a high dynamic range, running at the 120 Hz repetition rate of the Linac Coherent Light Source (LCLS). The ePix10k consists of 16 modules, each with 352 × 384 pixels of 100 µm × 100 µm distributed on four ASICs, resulting in a 2.16 megapixel detector, with a 16.5 cm × 16.5 cm active area and ∼80% coverage. The high dynamic range is achieved with three distinct gain settings (low, medium, high) as well as two auto-ranging modes (high-to-low and medium-to-low). Here the three fixed gain modes are evaluated. The resulting dynamic range (from single photon counting to 10000 photons pixel −1 pulse −1 at 8 keV) makes it suitable for a large number of different XFEL experiments. The ePix10k replaces the large CSPAD in operation since 2011. The dimensions of the two detectors are similar, making the upgrade from CSPAD to ePix10k straightforward for most setups, with the ePix10k improving on experimental performance. The SLAC-developed ePix cameras all utilize a similar platform, are tailored to target different experimental conditions and are designed to provide an upgrade path for future high-repetition-rate XFELs. Here the first measurements on this new ePix10k detector are presented and the performance under typical XFEL conditions evaluated during an LCLS X-ray diffuse scattering experiment measuring the 9.5 keV X-ray photons scattered from a thin liquid jet.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Extensible High Energy Density Modeling Tool for Extreme Regimes

The overreaching goal of the project is to develop a simulation capability to model an entire High Energy Density (HED) target heated by an X-ray Free Electron Laser (XFEL) beam including the surrounding material with a focus on target material associated with subsequent shots. Our primary objective is to study target fratricide problems, where radiation/debris from the current shot degrade the target for subsequent shots. This work will have a large impact on research being conducted at HED facilities where the quality of data is directly related to the effective repetition rate of the driver, which is often limited by target fratricide problems. This project focuses on a stream of closely spaced droplet targets that are appropriate for new very high repetition rate sources such as the ~1 MHz LCLS-II upgraded XFEL. The capability of the PISALE (Pacific Island Structured-AMR with ALE) code is extended to model this class of problems. We summarize the capability and improvements made to the HED branch of the PISALE code. We discuss our simulations of target fratricide for small (5 micron) hydrogen droplets heated by an XFEL beam at SLAC. We also compare simulations of the initial dynamics of larger (50 micron) water droplets, heated by the same XFEL beam, with experimental data. We briefly discuss training, dissemination, and related activities associated with this project.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multi-Beam-Energy Control Unit Based on Triple-Bend Achromats

X-ray free electron lasers (XFELs) are the new generation of particle accelerator-based light sources, capable of producing tunable, high-power X-ray pulses that are increasingly vital across various scientific disciplines. Recently, continuous-wave (CW) XFELs driven by superconducting linear accelerators have garnered significant attention due to their ability to enhance availability by supporting multiple undulator lines simultaneously. In this paper, we introduce a novel delay system comprising four triple-bend achromats (TBAs). This delay system was combined with fast kickers and can be employed to generate electron beams on a bunch-to-bunch basis in a CW-XFEL facility. Based on the parameters of the Shanghai High-Repetition-Rate XFEL and Extreme Light Facility, start-to-end simulations demonstrate that the TBA-based delay system achieves excellent electron beam qualities while providing a wide beam-energy-tuning range from 1.39 to 8 GeV.

43 PARTICLE ACCELERATORS↗

Predicting the oxidation states of Mn ions in the oxygen-evolving complex of photosystem II using supervised and unsupervised machine learning

Abstract Serial Femtosecond Crystallography at the X-ray Free Electron Laser (XFEL) sources enabled the imaging of the catalytic intermediates of the oxygen evolution reaction of Photosystem II (PSII). However, due to the incoherent transition of the S-states, the resolved structures are a convolution from different catalytic states. Here, we train Decision Tree Classifier and K-means clustering models on Mn compounds obtained from the Cambridge Crystallographic Database to predict the S-state of the X-ray, XFEL, and CryoEM structures by predicting the Mn’s oxidation states in the oxygen-evolving complex. The model agrees mostly with the XFEL structures in the dark S 1 state. However, significant discrepancies are observed for the excited XFEL states (S 2 , S 3, and S 0 ) and the dark states of the X-ray and CryoEM structures. Furthermore, there is a mismatch between the predicted S-states within the two monomers of the same dimer, mainly in the excited states. We validated our model against other metalloenzymes, the valence bond model and the Mn spin densities calculated using density functional theory for two of the mismatched predictions of PSII. The model suggests designing a more optimized sample delivery and illumiation systems are crucial to precisely resolve the geometry of the advanced S-states to overcome the noncoherent S-state transition. In addition, significant radiation damage is observed in X-ray and CryoEM structures, particularly at the dangler Mn center (Mn4). Our model represents a valuable tool for investigating the electronic structure of the catalytic metal cluster of PSII to understand the water splitting mechanism.

Plant Sciences↗

Ka-band linearizer for the Ultra-Compact X-ray free-electron laser at UCLA

There is a strong demand for accelerating structures able to achieve higher gradients and more compact dimensions for the next generation of linear accelerators for research, industrial and medical applications. Notably innovative technologies will permit compact and affordable advanced accelerators as the linear collider and X-ray free-electron lasers (XFELs) with accelerating gradients over twice the value achieved with current technologies. In particular XFELs are able to produce coherent X-ray pulses with peak brightness 10 orders of magnitude greater than preceding approaches, which has revolutionized numerous research fields through imaging of the nanoscopic world at the time and length scale of atom-based systems, that is of femtosecond and Angstrom. There is a strong interest for combining these two fields, to form a proper tool with the goal of producing a very compact XFEL in order to investigate multi-disciplinary topics in chemistry, biology, materials science, medicine and physics. In the framework of the Ultra-Compact XFEL project under study at the University of California, Los Angeles, a high gradient radio-frequency accelerating structure for the longitudinal phase-space linearization with an integrated voltage of at least 15 MV working on 6th harmonic of the main Linac frequency is required. We here present the electromagnetic design of a cryogenic normal-conducting 8 cm long Ka-band standing-wave linearizer working on π mode with a target accelerating gradient beyond 100 MV/m. The studies have been performed analytically and numerically to investigate the beam dynamics and electromagnetic issues.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of X-ray free-electron laser-induced shockwaves on haemoglobin microcrystals delivered in a liquid jet

X-ray free-electron lasers (XFELs) enable obtaining novel insights in structural biology. The recently available MHz repetition rate XFELs allow full data sets to be collected in shorter time and can also decrease sample consumption. However, the microsecond spacing of MHz XFEL pulses raises new challenges, including possible sample damage induced by shock waves that are launched by preceding pulses in the sample-carrying jet. We explored this matter with an X-ray-pump/X-ray-probe experiment employing haemoglobin microcrystals transported via a liquid jet into the XFEL beam. Diffraction data were collected using a shock-wave-free single-pulse scheme as well as the dual-pulse pump-probe scheme. The latter, relative to the former, reveals significant degradation of crystal hit rate, diffraction resolution and data quality. Crystal structures extracted from the two data sets also differ. Since our pump-probe attributes were chosen to emulate EuXFEL operation at its 4.5 MHz maximum pulse rate, this prompts concern about such data collection.

59 BASIC BIOLOGICAL SCIENCES↗