Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “X-ray line profile analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

FE K EMISSION AND ABSORPTION FEATURES IN THE XMM-EPIC SPECTRUM OF THE SEYFERT GALAXY IC 4329A

We present a re-analysis of the XMM-Newton long-look of the X-ray bright Seyfert galaxy IC 4329a. The Fe K bandpass is dominated by two peaks, consistent with emission from neutral or near-neutral Fe Ka and KP. A relativistic diskline model whereby both peaks are the result of one doubly-peaked diskline profile is found to be a poor description of the data. Models using two relativistic disklines are found to describe the emission profile well. A low-inclination, moderately-relativistic dual-diskline model is possible if the contribution from narrow components, due to distant material, is small or absent. A high-inclination, moderately relativistic profile for each peak is possible if there are roughly equal contributions from both the broad and narrow components. Upper limits on Fe XXV and Fe XXVI emission and absorption at the systemic velocity of IC 4329a are obtained. We also present the results of RXTE monitoring of this source obtained so far; the combined XMM-Newton and RXTE data sets allow us to explore the time-resolved spectral behavior of this source on time scales ranging from hours to 2 years. We find no strong evidence for variability of the Fe Ka emission line on any time scale probed, likely due to the minimal level of continuum variability. We detect a narrow absorption line, at a energy of 7.68 keV in the rest frame of the source; its significance has been confirmed using Monte Carlo simulations. This feature is most likely due to absorption from Fe XXVI blueshifted to approximately 0.1c relative to the systemic velocity, making IC 4329a the lowest-redshift AGN known with a high-velocity, highly-ionized outflow component. As is often the case with similar outflows seen in high-luminosity quasars, the estimated mass outflow rate is larger than the inflow accretion rate, signaling that the outflow represents a substantial portion of the total energy budget of the AGN. The outflow could arise from a radiatively-driven disk wind, or it may be in the form of a discrete, transient blob of ejected material.

Markowitz, A.↗

XRISM Spectroscopy of the Fe Kα Emission Line in the Seyfert Active Galactic Nucleus NGC 4151 Reveals the Disk, Broad-line Region, and Torus

Abstract We present an analysis of the first two XRISM/Resolve spectra of the well-known Seyfert-1.5 active galactic nucleus (AGN) in NGC 4151, obtained in 2023 December. Our work focuses on the nature of the narrow Fe K α emission line at 6.4 keV, the strongest and most common X-ray line observed in AGN. The total line is found to consist of three components. Even the narrowest component of the line is resolved with evident Fe K α ,1 (6.404 keV) and K α ,2 (6.391 keV) contributions in a 2:1 flux ratio, fully consistent with neutral gas with negligible bulk velocity. Subject to the limitations of our models, the narrowest and intermediate-width components are consistent with emission from optically thin gas, suggesting that they arise in a disk atmosphere and/or wind. Modeling the three line components in terms of Keplerian broadening, they are readily associated with (1) the inner wall of the “torus,” (2) the innermost optical “broad-line region” (or “X-ray BLR”), and (3) a region with a radius of r ≃ 100 GM / c 2 that may signal a warp in the accretion disk. Viable alternative explanations of the broadest component include a fast-wind component and/or scattering; however, we find evidence of variability in the narrow Fe K α line complex on timescales consistent with small radii. The best-fit models are statistically superior to simple Voigt functions, but when fit with Voigt profiles the time-averaged lines are consistent with a projected velocity broadening of FWHM = 1600 − 200 + 400 km s − 1 . Overall, the resolution and sensitivity of XRISM show that the narrow Fe K line in AGN is an effective probe of all key parts of the accretion flow, as it is currently understood. We discuss the implications of these findings for our understanding of AGN accretion, future studies with XRISM, and X-ray-based black hole mass measurements.

Audard, Marc (ORCID:000000034721034X)↗

Coronal Dynamics and Complete Flare Energy Budget for the M Dwarf AD Leo

This grant supported the observing and data analysis for FUSE Cycle 3 project C114 to observe the flare star AD Leo for 50 ksec coordinated with HST (Hubble Space Telescope) STIS ultraviolet spectroscopy and Chandra X-ray spectroscopy. Unfortunately, it was impossible to obtain the planned FUSE observations because AD Leo is a low declination target (delta approximately 20 degrees) and was rendered unobservable by restrictions in the sky coverage for FUSE observations. In April 2002 another M dwarf star, EV Lac, which is at significantly higher declination, was substituted for this project. EV Lac was observed by FUSE for a cumulative exposure of 35 ksec on 2002 July 1. The observation used the large LWRS aperture and collected data in time-tagged mode. The LWRS aperture is large enough that the target should remain within the aperture despite the normal level of pointing jitter and target drift experienced during FUSE observing. Our examination of the stellar signal showed that the target was well within the aperture throughout the observation. The data were split into night-time and day-time data so that the effects of airglow emission were recognizable. No obvious flaring, the primary science objective, was detected during the observation. The only stellar lines detected are 0 VI 1031.9, 1037.6 Angstrom, and the C III 1175 Angstrom, UV multiplet and the 977 Angstrom, resonance line. A comparison of the day-time and night-time spectra show that the 0 VI lines and the C III intersystem multiplet are unaffected by airglow features. The day-time data 977 Angstrom profile shows the presence of significant scattered solar C III photons, which should not be present in the night time spectrum. Emission fluxes for these lines were measured by direct summation of the emission lines. No continuum signal was detected in the region of these lines. The cleanest emission line profiles are for the O VI lines and we performed Gaussian fitting for these profiles. Both lines are clearly skewed with the emission peak shifted shortward of the line centroid and with emission extending further in the longward wing than for the shortward wing. A single Gaussian fits the 1032 Angstrom line profile reasonably and gives a line flux similar to that from direct integration with a line width (FWHM) of 0.16 Angstrom, (46 kilometers per second).

Brown, Alexander↗

DEEPER: An Intergrated Platform for Deeper Roots

Crops with deeper roots would have multiple benefits, including better drought tolerance, reduced requirement for nitrogen fertilizer, and better sequestration of atmospheric CO 2 . DEEPER is an integrated platform of phenomic, genomic, and in silico technologies to generate maize lines with deeper roots. DEEPER is: LEADER (Leaf Elemental Accumulation from Deep Roots) is a breakthrough technology to nondestructively measure rooting depth by using the plant itself as a sensor. LEADER uses handheld X-ray Fluorescence spectrometry to quantify foliar accumulation of elements that are differentially distributed in the soil profile. LEADER is nondestructive and is orders of magnitude cheaper, faster, and more precise than any competing assay of rooting depth in the field. LEADER is able to distinguish deep-rooted from shallow-rooted maize lines in the field without the need for costly and noisy soil coring. RootRobot/DIRT3D, to automatically phenotype root architecture in any field, combining RootRobot, a mechatronics platform to excavate, clean, section, and image mature root crowns, with DIRT3D, software to quantify architectural traits in 3D. Anatomics, a high-throughput platform to phenotype root anatomy, combining LAT 2.0, a technology for 3D imaging of root anatomy and composition, with RootScan3D, software to automatically extract 3D anatomical and cell wall composition metrics from LAT 2.0 output. Using this platform we discovered two novel root traits, parenchyma cell wall thickness and multiseriate cortical sclerenchyma, that improve rooting depth and drought tolerance in maize and wheat. OpenSimRoot/Deep, software to simulate root interaction with hard subsoils. Using this platform we discovered novel concepts regarding how to increase crop rooting depth by modulating how individual root axes respond to hard soil. DeepGenes, a toolkit of genes, parent lines, and genomic selection strategies to enable breeding hybrids with deeper roots. We discovered 3 novel root genes that increase rooting depth in maize and wheat. DEEPER discovered novel root phenotypes for deeper rooting, and delivered validated ideotypes for deeper-rooted maize; novel technologies to rapidly assess root depth, root architecture and anatomy in field-grown plants; novel software tools for root modeling and 3D image analysis of root architecture and anatomy; and validated genes and genomic selection models to deploy traits for deeper rooting in maize breeding. Each DEEPER technology is transformative in its own right, and exceeds existing technologies. They are mutually synergistic, deployable for field-grown plants, and are ready for application. The phenotyping and modeling technologies are readily applicable to many crops, and genetic leads in maize may have utility in other grasses. Taken as a whole they represent a transformative platform to develop deeper-rooted crops, with greater drought tolerance, reduced fertilizer requirement, and greater carbon sequestration.

59 BASIC BIOLOGICAL SCIENCES↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Calibration and characterization of the line-VISAR diagnostic at the HED-HIBEF instrument at the European XFEL

In dynamic-compression experiments, the line-imaging Velocity Interferometer System for Any Reflector (VISAR) is a well-established diagnostic used to probe the velocity history, including wave profiles derived from dynamically compressed interfaces and wavefronts, depending on material optical properties. Knowledge of the velocity history allows for the determination of the pressure achieved during compression. Such a VISAR analysis is often based on Fourier transform techniques and assumes that the recorded interferograms are free from image distortions. In this paper, we describe the VISAR diagnostic installed at the HED-HIBEF instrument located at the European XFEL along with its calibration and characterization. It comprises a two-color (532, 1064 nm), three-arm (with three velocity sensitivities) line imaging system. We provide a procedure to correct VISAR images for geometric distortions and evaluate the performance of the system using Fourier analysis. We finally discuss the spatial and temporal calibrations of the diagnostic. As an example, we compare the pressure extracted from the VISAR analysis of shock-compressed polyimide and silicon.

47 OTHER INSTRUMENTATION↗

Decoding α-MoC 1− x Nanoparticle Formation in Continuous Flow via Machine Learning

Molybdenum carbide nanoparticles (α-MoC 1−x NPs) are promising catalysts that offer noble-metal-like performance at lower cost. We report a mild continuous-flow synthesis of α-MoC 1−x NPs from Mo(CO) 6 , coupled with in-line spectroscopic monitoring and machine learning (ML)-based analysis to quantify precursor conversion and product formation in real time. A multilayer perceptron ML model was found to accurately deconvolute complex, nonlinear spectral patterns, enabling identification of a two-step reaction pathway, involving precursor conversion to an amorphous intermediate followed by intraparticle crystallization to α-MoC 1−x NPs, with the first step being rate limiting. Ex situ small angle X-ray scattering (SAXS) and X-ray diffraction (XRD) validation confirm the predicted concentration profiles and crystallization behavior. This integrated approach showcases how ML can empower insights into NP nucleation and growth, paving the way for self-driving, flow-based platforms for NP synthesis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Phase stability and microstructure of neutron-irradiated substoichiometric yttrium dihydrides

The impact of the neutron-displacement damage on phase stability and microstructure of substoichiometric yttrium dihydrides (YH x , x <2) were investigated to assess their use as solid moderator in high-temperature nuclear reactors. YH x specimens were, thus, subjected to neutron irradiations in the range of 0.1–2 displacements per yttrium atom (dpa-Y) in the temperature range of 536–878°C at the Oak Ridge National Laboratory's (ORNL's) High Flux Isotope Reactor (HFIR). YH x specimens were initially prepared at stoichiometry (H/Y) ratios of 1.69 and 1.83. HFIR-irradiated specimens were characterized by variety of techniques to investigate H retention characteristics including dimensional analysis, optical microscopy, scanning electron microscopy electron back scatter diffraction (EBSD), transmission electron microscopy, thermal desorption spectroscopy (TDS), and high-energy x-ray diffraction (HE-XRD) characterizations. Overall, YH x exhibited notable structural and phase stability under short-term neutron-irradiation, except for the samples with significant silicon carbide (SiC) interaction at high doses and temperatures. Basic dimensional and mass measurements were misleading for accurate assessment of H retention, as confirmed by EBSD phase maps, XRD line profiles, and TDS signals. Thus, it was discussed that a robust H retention metric is needed to assess irradiated hydrides. Further, nanoscale cavities were observed as a result of the neutron irradiation in all samples. Although no clear impact of dose and irradiation temperature was determined, the initial H/Y ratio had an impact on the cavity number density where low H/Y specimens had high-resistance to cavity formation. The Y-vacancy cluster formation at the collision stage of the displacement cascade and their stabilization by H were considered to be the likely underlying mechanisms for the observed cavity microstructure.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Synthetic modeling of soft x-ray emissivity for magnetic island analysis in LTX-β

We present a synthetic soft x-ray (SXR) forward-modeling framework that characterizes the emissivity structure of rotating magnetic islands in the Lithium Tokamak eXperiment-β across space and time. Magnetic islands associated with tearing modes produce modulations in line-integrated SXR brightness. Traditional tomographic methods struggle to resolve these structures in devices with limited sightlines, resulting in an under-determined inversion problem, or otherwise necessitate equilibrium reconstruction data, preventing their use in active control. Our approach removes this challenge by combining a fully three-dimensional ray-tracing model with a time-dependent emissivity prescription of a $m/n$ = 2/1 magnetic island. The model is validated through helical island geometry, rotation measured by magnetic diagnostics, and equilibrium constraints from PSI-Tri reconstructions. Synthetic brightness signals are generated for each photodiode sightline from a modeled emissivity profile and directly compared with experimental data from a tangential midplane SXR array. By fitting the synthetic diagnostic output to the observed brightness across time, we simultaneously infer key geometric parameters-such as island radial location, island width, and rotation frequency-without requiring full tomographic reconstruction, all with an average absolute deviation of less than 3%. This work demonstrates that forward modeling with a single tangential array can extract key island parameters in a spherical tokamak, providing a computationally efficient alternative to conventional SXR tomography and providing a pathway toward real-time magnetic-island characterization in future devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multiple giant eruptions and X-ray emission in the recoiling AGN/LBV candidate SDSS1133

We present a comprehensive analysis of 20 yr worth of multicolour photometric light curves, multiepoch optical spectra, and X-ray data of an off-nuclear variable object SDSS1133 in Mrk 177 at z = 0.0079. The UV-optical light curves reveal that SDSS1133 experienced four outbursts in 2001, 2014, 2019, and 2021. The persistent UV-optical luminosity in the non-outbursting state is ~1041 erg s -1 with small-scale flux variations, and peak luminosities during the outbursts reach ~10 42 erg s -1 . The optical spectra exhibit enduring broad hydrogen Balmer P-Cygni profiles with the absorption minimum at ~-2000 km s -1 , indicating the presence of fast-moving ejecta. Chandra detected weak X-ray emission at a 0.3-10-keV luminosity of L X = 4 × 10 38 erg s -1 after the 2019 outburst. These lines of evidence suggests that SDSS1133 is an extreme luminous blue variable (LBV) star experiencing multiple giant eruptions with interactions of the ejected shell with different shells and/or circumstellar medium (CSM), and disfavours the recoiling active galactic nuclei scenario suggested in the literature. We suggest that pulsational pair-instability may provide a viable explanation for the multiple energetic eruptions in SDSS1133. If the current activity of SDSS1133 is a precursor of a supernova explosion, we may be able to observe a few additional giant eruptions and then the terminal supernova explosion or collapse to a massive black hole in future observations.

79 ASTRONOMY AND ASTROPHYSICS↗

The Pinhole/Occulter Facility

A large occulting system in space can be used for high resolution X-ray observations and for large aperture coronagraphic observations in visible and UV light. The X-ray observations can combine high angular resolution in hand (10 keV) X-radiation with the high sensitivity of a multiple pinhole camera, and can permit sensitive observations of bremsstrahlung from nonthermal particles in the corona. The large aperture coronagraphs have two major advantages: high angular resolution and good photon collection. This will permit observations of small scale structures in the corona for the first time and will give sufficient counting rates above the coronal background rates for sensitive diagnostic analysis of intensities and line profiles for coronal structures in the solar wind acceleration region. The technical basis for performing observations with a large occulting system in these three wavelength ranges is described as well as a pinhole/occulter facility presently being considered for Spacelab. Some indications about future developments are included.

Hudson, H. S.↗

High-precision source location of the 1978 November 19 gamma-ray burst

The celestial source location of the November 19, 1978, intense gamma ray burst has been determined from data obtained with the interplanetary gamma-ray sensor network by means of long-baseline wave front timing instruments. Each of the instruments was designed for studying events with observable spectra of approximately greater than 100 keV, and each provides accurate event profile timing in the several millisecond range. The data analysis includes the following: the triangulated region is centered at (gamma, delta) 1950 = (1h16m32s, -28 deg 53 arcmin), at -84 deg galactic latitude, where the star density is very low and the obscuration negligible. The gamma-ray burst source region, consistent with that of a highly polarized radio source described by Hjellming and Ewald (1981), may assist in the source modeling and may facilitate the understanding of the source process. A marginally identifiable X-ray source was also found by an Einstein Observatory investigation. It is concluded that the burst contains redshifted positron annihilation and nuclear first-excited iron lines, which is consistent with a neutron star origin.

Cline, T. L.↗

Explicit relations in Bowen fluorescence - Applications to nebulae, the sun, Scorpius X-1, and laboratory plasmas

A general analysis of the fluorescent process is described which emphasizes the differing roles of escape probabilities in one-component and two-component gases, and the existence of discrete fluorescent saturation regimes. Explicit formulas are obtained and discussed for astrophysical Bowen fluorescence, as a concrete example, with applications to planetary nebulae, the solar atmosphere and the X-ray binary Sco X-1. An expression is also provided and evaluated for the profile overlap integral involved in the pumping process. A preliminary conclusion is deduced that densities in the fluorescent line-emitting regions of nebular sources may be higher than those derived from forbidden line ratios. The analysis is extended to a proposed laboratory investigation which would exploit the possibility of controlling the determining factors in the fluorescent process, i.e., O III/He II abundance ratio, optical depth, and photoexciting radiation field.

Kastner, S. O.↗

Global X-ray Spectral Variation of Eta Carinae through the 2003 X-ray Minimum

We report on the results of the X-ray observing campaign of the massive, evolved star Eta Carinae in 2003 around its recent X-ray Minimum, mainly using data from the XMM-Newton observatory. These imaging observations show that the hard X-ray source associated with the Eta Carinae system does not completely disappear in any of the observations during the Minimum. The variation of the spectral shape revealed two emission components. One newly discovered component did not exhibit any variation on kilo-second to year-long timescales, in a combined analysis with earlier ASCA and ROSAT data, and might represent the collision of a high speed outflow from Eta Carinae with ambient gas clouds. The other emission component was strongly variable in flux but the temperature of the hottest plasma did not vary significantly at any orbital phase. Absorption to the hard emission, was about a factor of three larger than the absorption determined from the cutoff of the soft emission, and reached a maximum of approx.4 x 10(exp 23)/sq cm before the Minimum. The thermal Fe\rm XXV emission line showed significant excesses on both the red and blue sides of the line outside the Minimum and exhibited a large redward excess during the Minimum. This variation in the line profile probably requires an abrupt change in ionization balance in the shocked gas.

Hamaguchi, K.↗

RXTE Observations of the 1A 1118-61 in an Outburst, and the Discovery of a Cyclotron Line

We present the analysis of RXTE monitoring data obtained during the January 2009 outburst of the hard X-ray transient IA 1118-61. Using these observations the broadband (3.5-120 keV) spectrum of the source was measured for the first time ever. We have found that the broadband continuum spectrum of the source is similar to other accreting pulsars and is well described by several conventionally used phenomenological models. We have discovered that regardless of the applied continuum model, a prominent broad absorption feature at approx. 55 keV is observed. We interpret this feature as a Cyclotron Resonance Scattering Feature (CRSF). The observed CRSF energy is one of the highest known and corresponds to a magnetic field of B approx. 4.8 x 10(exp 12) G in the scattering region. Furthermore, our data suggests an iron emission line presence, which was not reported previously for lA 1118-61 as well. Timing properties of the source, including a strong spin-up, were found to be similar to those observed by CGRO/BATSE during the previous outburst, however the broadband capabilities of RXTE reveal a more complicated energy dependency of the pulse-profile.

Doroshenko, V.↗

X-Ray Reflected Spectra from Accretion Disk Models. II. Diagnostic Tools for X-Ray Observations

We present a comprehensive study of the emission spectra from accreting sources. We use our new reflection code to compute the reflected spectra from an accretion disk illuminated by X-rays. This set of models covers different values of ionization parameter, solar iron abundance and photon index for the illuminating spectrum. These models also include the most complete and recent atomic data for the inner-shell of the iron and oxygen isonuclear sequences. We concentrate our analysis to the 2 - 10 keV energy region, and in particular to the iron K-shell emission lines. We show the dependency of the equivalent width (EW) of the Fe Ka with the ionization parameter. The maximum value of the EW is approx. 800 eV for models with log Epsilon approx. 1.5, and decreases monotonically as Epsilon increases. For lower values of Epsilon the Fe K(alpha) EW decreases to a minimum near log Epsilon approx. 0.8. We produce simulated CCD observations based on our reflection models. For low ionized, reflection dominated cases, the 2 -10 keV energy region shows a very broad, curving continuum that cannot be represented by a simple power-law. We show that in addition to the Fe K-shell emission, there are other prominent features such as the Si and S L(alpha) lines, a blend of Ar VIII-XI lines, and the Ca x K(alpha) line. In some cases the S xv blends with the He-like Si RRC producing a broad feature that cannot be reproduced by a simple Gaussian profile. This could be used as a signature of reflection.

Garcia, J.↗

Possible Detection of an Emission Cyclotron Resonance Scattering Feature from the Accretion-Powered Pulsar 4U 1626-67

We present analysis of 4U 1626-67, a 7.7 s pulsar in a low-mass X-ray binary system, observed with the hard X-ray detector of the Japanese X-ray satellite Suzaku in 2006 March for a net exposure of ~88 ks. The source was detected at an average 10-60 keY flux of approx 4 x 10-10 erg / sq cm/ s. The phase-averaged spectrum is reproduced well by combining a negative and positive power-law times exponential cutoff (NPEX) model modified at approx 37 keY by a cyclotron resonance scattering feature (CRSF). The phase-resolved analysis shows that the spectra at the bright phases are well fit by the NPEX with CRSF model. On the other hand. the spectrum in the dim phase lacks the NPEX high-energy cutoff component, and the CRSF can be reproduced by either an emission or an absorption profile. When fitting the dim phase spectrum with the NPEX plus Gaussian model. we find that the feature is better described in terms of an emission rather than an absorption profile. The statistical significance of this result, evaluated by means of an F test, is between 2.91 x 10(exp -3) and 1.53 x 10(exp -5), taking into account the systematic errors in the background evaluation of HXD-PIN. We find that the emission profile is more feasible than the absorption one for comparing the physical parameters in other phases. Therefore, we have possibly detected an emission line at the cyclotron resonance energy in the dim phase.

Iwakiri, W. B.↗

Thermo-Poro-Mechanical Modeling of RTV Intumescence

Room temperature vulcanizing (RTV) silicone is a high-temperature adhesive used as a gap-filler between heatshield tiles in numerous entry missions. Its propensity to intumesce, or swell upon exposure to heat, is a well-known effect that needs to be carefully quantified during design. At tile interfaces of charring ablators, intumescence, combined with differential recession, could cause the gap filler to protrude past the ablator outer mold line, forming a “fence”. Fencing can in turn cause transition to turbulence of the flow wetting the heat shield, leading to augmented surface heating. Recent experiments conducted at the Plasmatron X facility, the high enthalpy wind tunnel of the Center for Hypersonics and Entry Systems Studies, have shown prominent fencing of RTV gap fillers in PICA, under both nitrogen and air plasmas. Similar observations are well known in the arcjet literature. Further experiments under controlled environment, performed using in situ X-ray micro-computed tomography (micro-CT) at the Advanced Light Source (ALS), have shown heating rate-dependent swelling and shrinkage of RTV during pyrolysis. To simulate RTV intumescence, a novel model was introduced in the Porous Materials Analysis Toolbox based on OpenFOAM, PATO, to account for pore-pressure buildup within both closed- and open-pores. The governing equation for the thermo-poro-mechanical response were developed, assuming linear elasticity for the charring silicone. A new multi-pyrolysis model that tracks non-monotonic advancement of material properties with pyrolysis was proposed. This model addresses the limitations of state-of-the-art ablator models to capture the different stages of thermal degradation and coupled thermomechanics. Swelling of RTV was simulated using the new thermo-poro-mechanical model and compared against in situ micro-CT data. Results showed good agreement in intumescence height and temperature profiles at all heating rates, indicating that the key factor contributing to RTV swelling is the internal pressure build-up within closed- and open-pores. As RTV is cured into a soft (rubbery) compound with low-porosity and permeability, initial temperature increase and pyrolysis gas production cause a significant increase of internal pressure, causing a pronounced volume growth. As thermal degradation progresses, rigidization of the silicone occurs due to char hardening which counteract volume shrinkage after gas pressure relief. Overall, our model shows that accounting for changes in properties such porosity, permeability and key thermomechanical coefficients is crucial for capturing the RTV volume change during ablation and enable a predictive capability for heatshield tile interface response. A plan for future calibration of thermomechanical properties evolution during degradation is discussed, as a key next step to close the new model.

RTV↗