Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Window”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

End-Use Savings Shapes Measure Documentation: Window Film

This documentation focuses on a single end-use savings shape measure - window film. The window film studied in this analysis, called solar control film, is a passive retrofit solution for windows that does not involve window replacement. This type of film is composed of transparent, tinted, or metalized laminated polyester layers and can be attached to an existing window surface (either on the exterior or interior side of the window). The properties of the window film are designed to shift the thermal and optical performances of the overall glazing system in order to serve various needs the customer would have (e.g., heat, glare). While the practical goal of purchasing and installing a window film varies widely in the real market, this study only focuses on the goal of energy savings, and highlighting the corresponding emissions. Other important aspects that customers typically consider include visual comfort, privacy, aesthetics, ultraviolet protection, etc. Thus, in practice, customers often choose a window film product not only to save energy (or cost) but also to mitigate issues around glare, excessive light, daytime privacy, or inconsistent appearance of the building. Window film products that were modeled in this analysis significantly reduced the solar heat gain coefficient of the overall glazing system, resulting in better energy savings for buildings in hot climate regions. However, significantly reducing the solar heat gain coefficient that can block unfavorable heat during the summer can actually harm blocking favorable heat during the winter. By applying window films on a stock of buildings covering various load and weather conditions, this analysis highlights when (e.g., time of day) and where (e.g., geospacial location) we can save energy with window films.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Window Attachments: The Next Big Energy-Savings Measure?

Windows in residential buildings are estimated to generate 29% of all HVAC heating and cooling load, approximately 2.67 quadrillion Btu (Apte and Arasteh 2006). Although more than a third of residential windows are single pane, very few utility programs offer incentives for installation of energy-efficient windows (Bickel et al. 2013). The reason is simple: unless someone is already planning to replace their windows, the payback can often take a decade, if not longer. Preliminary data indicates that some energy-efficient window attachments, such as low- emissivity (low-e) storm windows and interior panels, cellular shades, interior and exterior roller shades and shutters, window films, solar screens, window quilts, and awnings, can deliver cost-effective energy savings. Additionally, the means to reliably identify and compare energy-efficient window attachment products will soon be available through the Attachment Energy Rating Council (AERC), a public interest energy performance rating and certification organization co-funded by the U.S. Department of Energy (DOE) and the window attachment industry. This paper presents, for the first time, national and regional energy savings estimates for cellular shades and low-emissivity storm windows and panels using existing data on household energy savings potential. This paper is an early step in the process of determining the cost-effectiveness of window attachments for utility programs. The next step is for utilities to develop pilot programs to conduct field tests of these products, which will generate the energy savings data to determine if full-scale programs are cost-effective.

Bickel, Stephen↗

Double or Triple? Factors Influencing the Window Purchasing Decisions of High-Performance Home Builders

To better understand why triple-pane windows are so slow to catch on and to inform the development and adoption of a new approach to insulated windows, thin triple-pane windows (or thin triples), Pacific Northwest National Laboratory (PNNL) conducted a market assessment of the window purchasing practices of new home builders in 2018-19. While there are several players who can impact the adoption of new residential window technologies, this report focuses strictly on home builders and the key part they play in new window technology adoption. A better understanding of the motivations, experiences, and concerns expressed by new home builders regarding window purchases could inform efforts to develop and deliver thin triple-pane windows and lead to their widespread acceptance in the marketplace. For the past several years, the DOE has supported the development of a thin triple-pane window that uses a center pane of thin glass and krypton gas fill to produce an insulated glass unit (IGU) with nearly the same weight and the same thickness as a double-pane IGU but with the performance of the heavier, thicker, standard triple-pane windows available today. To conduct this study, PNNL interviewed 29 home builders who have participated in the DOE Zero Energy Ready Home (ZERH) program. These builders include many of the most active builders in the DOE ZERH program. Together, they have constructed 2,534 of the 3,417 homes certified through the DOE program as of April 1, 2019. In 2018, they constructed an estimated 1,040 homes and purchased an estimated 17,800 windows. This report summarizes the key findings from these interviews.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental and data-driven characterization of window-induced air leakage in residential buildings

Windows contributes up to 40% of envelope heat losses and around 9% of total building energy consumption due to air leakage. In the U.S., 48 million homes still use single-pane windows. Although the U.S. has an estimated 1.4 billion windows in its building stock and about 24 million windows are installed annually, only around 29 million individual window replacements (∼2%) occur each year. To address this gap, this study generates empirical evidence by (1) evaluating the contribution of windows to whole-building air leakage in 20 residential buildings using blower door tests before and after window replacement and (2) assessing whether building and window characteristics influence the measured change. Most simulation studies assume that replacing windows not only lowers the U-factor but also reduces air leakage by 10–20%. However, this assumption lacks empirical validation, highlighting the need for experimental analysis of air leakage specifically associated with windows. Using blower door tests in accordance with ASTM E779–19, the results indicated an average reduction in air infiltration of 6.1% within the range of 0.5–19.30% across all buildings and no significant correlations were found between air leakage improvements and any building/window characteristics. This research aims to help homeowners, and energy modelers to provide empirical data on importance of upgrading to more energy-efficient windows, supporting energy-efficient building standards.

Air leakage↗

Low RF loss DC conductive ceramic for RF windows

Charging of RF windows has historically been problematic, frequently resulting in damage to the window severe enough that the window needs to be replaced. Many attempts have been made to prevent charging and therefore improve window lifetime, the most successful and common of which is coating the window with titanium nitride (TiN). Surface coatings such as TiN rely on the secondary electron yield of the coating material being lower than that of the ceramic window material, reducing the number of electrons emitted from a variety of mechanisms. An alternative approach is to introduce a small amount of DC conductivity to the ceramic itself, turning the traditionally insulating window into a mildly conductive one. This allows any charge on the surface of the window to drain rather than build until a discharge happens. A magnesium titanate ceramic has been developed with a small DC conductivity and used to make RF windows. Several window assemblies have been produced and tested, including 1.3 GHz waveguide and 650 MHz coaxial designs. The results of the conductive ceramic window test program will be presented.

43 PARTICLE ACCELERATORS↗

Design and Analysis of a Double Wall, Water Cooled Window for Accelerator Based Mo-99 Production

The electron accelerator based Mo-99 production technique requires the use of Rhodotrons to generate 38 MeV, 6.32 mA pulsed electron beams. The introduction of the pulsed beam structure has introduced fatigue concerns in the vacuum-helium windows that did not exist previously for electron beam production via linear accelerators. Previous analysis has shown that temperature fluctuations of approximately 100°C above and below the steady state operating temperature of ~500°C will occur within the windows. A water cooled window will eliminate this concern by reducing the primary mechanical stress due to the 300-psig helium pressure load as well as the secondary thermally induced stress. Although a water cooled window was considered years ago, the complexities of adding an additional water line was unattractive until now. A double wall, water cooled window has been designed and analyzed for this reason. The water cooled window design is shown to decrease the helium-side window temperature to as low as 125°C, while the vacuum-side window is maintained at 161°C at a water flow rate of 3.2 GPM. These low steady state temperatures reduce the thermal stress of the helium-side window significantly. Also, the primary mechanical stress has been reduced by roughly 50% due to the reduced pressure gradient across the helium-side window (150-psig water and 300-psig helium). Considering a Mo-99 production loss of roughly 1%, the water cooled window is a drastic improvement over the previous helium cooled designs and should be greatly considered for future upgrades and redesign.

43 PARTICLE ACCELERATORS↗

Development of radiometer windows for atmospheric entry vehicles

A test program was established to determine the feasibility of developing a radiometer window for stagnation region shock layer atmospheric entry experiments from geosynchronous orbit and with measurements extending into the VUV region to about 170 nm. This test program examined both isolated (uncooled) and cooled window mounting options. Preliminary tests determined the gross suitability of sapphire and fused silica as window materials. Measurements show that the expected maximum temperature (1500 C) is itself not a problem, but that temperature gradients can easily break a window and that the transmission of sapphire and of fused silica at 174 nm drops dramatically at temperatures beyond 800 C and 500 C, respectively. A series of developmental tests showed that the surface of an uncooled fused silica window begins to melt at the entry conditions tested while an uncooled sapphire window generally does not, and that a cooled sapphire window design that keeps the window below 800 C appears possible. The final proof-of-design tests narrowed the selection of possible candidate window sizes and mounting configurations. These tests demonstrate that the best insulated and cooled window designs use small diameter sapphire windows and that thermal modeling codes can be used to assist the design process.

Terrazas-Salinas, Imelda↗

New Rating Opening Windows to a World of Comfort, Opportunity, and Cost-Effective Savings

Window attachments offer a huge, cost-effective energy-saving opportunity that remains largely untapped. The newly launched window attachment energy rating and certification program, through the Attachments Energy Rating Council (AERC), is altering the way people think about residential and commercial window attachments by providing reliable, easy-to-understand energy performance information to consumers. Window attachments, such as blinds, shades, shutters, awnings, and low-emissivity (low-e) storm windows, represent an enormous existing market. With 64% of U.S. homes having single- or double-pane clear (non-low-e) less-efficient windows, the savings opportunity is significant. Studies of model homes show energy savings of 10% or more after installing more efficient storm window and cellular shades technologies (AERC 2016).In a study conducted by Efficiency Vermont, 68% of respondents had concerns with their existing windows and could benefit from an upgrade (Efficiency Vermont 2016).Through AERC, window attachment products are rated based on their Energy Performance (EP). The EP metric is an easy-to-understand comparative metric created for consumers. This rating not only allows consumers to make more informed decisions when buying attachments products, but also creates a new energy savings measure for utilities and efficiency programs to incentivize energy efficient window attachment products. This paper will outline the savings potential of window attachments, introduce the AERC rating program, detail the methodology behind the Energy Performance ratings, and explain the AERCalc tool that generates the ratings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

New Rating Opening Windows to a World of Comfort, Opportunity, and Cost-Effective Savings

Window attachments offer a huge, cost-effective energy-saving opportunity that remains largely untapped. The newly launched window attachment energy rating and certification program, through the Attachments Energy Rating Council (AERC), is altering the way people think about residential and commercial window attachments by providing reliable, easy-to-understand energy performance information to consumers. Window attachments, such as blinds, shades, shutters, awnings, and low-emissivity (low-e) storm windows, represent an enormous existing market. With 64% of U.S. homes having single- or double-pane clear (non-low-e) less-efficient windows, the savings opportunity is significant. Studies of model homes show energy savings of 10% or more after installing more efficient storm window and cellular shades technologies (AERC 2016). In a study conducted by Efficiency Vermont, 68% of respondents had concerns with their existing windows and could benefit from an upgrade (Efficiency Vermont 2016). Through AERC, window attachment products are rated based on their Energy Performance (EP). The EP metric is an easy-to-understand comparative metric created for consumers. This rating not only allows consumers to make more informed decisions when buying attachments products, but also creates a new energy savings measure for utilities and efficiency programs to incentivize energy efficient window attachment products. Here, this paper will outline the savings potential of window attachments, introduce the AERC rating program, detail the methodology behind the Energy Performance ratings, and explain the AERCalc tool that generates the ratings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thin Triples Expand the Affordable High-Performance Window Options For Retrofit

Sales of high-performance triple-pane windows make up only a small fraction (~3%) of total window sales in the United States with relatively stagnant market growth over the past 20 years. High costs have been the most commonly cited barrier to adoption. The emergence of thin triples that can fit into the glazing pocket of existing double pane windows has the potential to revolutionize the high-performance window market in particular the retrofit market by enabling glass only upgrades for situations where the frames are still in good condition. The retrofit market has other unique challenges not found in new construction that can be solved or reduced by thin triple pane windows. Insert replacements are often pursued instead of full frame replacement, in retrofits, this method reduces the net free area of a window and can turn an egress window into one that no longer meets the net free area requirements for egress. Thin frames minimize such occurrences. However, these thin frames can often not accommodate the weight of a traditional triple pane, thin triples can bring high performance to this situation. Thicker frames can also increase retrofit labor costs because the interior drywall and/or trim molding needs to be cut back to accommodate a thicker frame while thin triples can fit into frames that match the thickness of the existing window. This paper presents information about field test experiences the highlight these retrofit advantages from experiencing the challenges associated with retrofitting a thick frame as well as the supply chain, purchasability, material and labor costs, and real-world energy and non-energy performance associated with the IGU only replacement method.

window retrofits, thin triple-pane windows, high p↗

High-Performance Windows -- More than just a Pretty Hole in the Wall

As more stringent building energy codes and better insulation products combine to yield better performing walls, window efficiency is coming into sharper focus. The U.S. Department of Energy has supported several projects through its national laboratories to improve the thermal performance of windows. At Pacific Northwest National Laboratory (PNNL) in Richland, Washington, the PNNL Lab Homes, two fully monitored identical side-by-side manufactured homes, have been used to test the performance of several window improvements including triple-pane windows, storm windows with low-emissivity (low-e) coatings, smart automated interior insulated shades, and exterior shading products. Findings will be presented on these studies, along with impacts. For example, PNNL’s Lab Home research on low-e storm windows has helped to support a new ENERGY STAR certification, industry standards, and utility incentives. Preliminary findings will also be presented on current Lab Homes experiments focusing on exterior shades. The session will also present findings from related field studies and a market assessment of emerging high-efficiency windows technologies and discuss some of PNNL’s planned field studies that will focus on validating the benefits and costs of the emerging thin triple-pane high-R window.

windows, high-r windows, insulating windows, windo↗

Design of the beryllium window for Brookhaven Linac Isotope Producer

In the Brookhaven Linac Isotope Producer (BLIP) beam line, there were two Beryllium (Be) windows with an air gap to separate the high vacuum upstream side from low vacuum downstream side. There had been frequent window failures in the past which affected the machine productivity and increased the radiation dose received by workers due to unplanned maintenance. To improve the window life, design of Be window is reexamined. Detailed structural and thermal simulations are carried out on Be window for different design parameters and loading conditions to come up with better design to improve the window life. The new design removed the air gap and connect the both beam lines with a Be window in-between. The new design has multiple advantages such as 1) reduces the beam energy loss (because of one window with no air gap), 2) reduces air activation due to nuclear radiation and 3) increased the machine reliability as there is no direct pressure load during operation. For quick replacement of this window, an aluminum bellow coupled with load binder was designed. There hasn’t been a single window failure since the new design was implemented in 2012.

43 PARTICLE ACCELERATORS↗

Mind the Gap: Summary of Window Residential Retrofit Solutions

Improving the insulation, solar heat gain, and infiltration characteristics of windows in a home has the potential to significantly improve the overall thermal performance by reducing heat transfer through the window and also by decreasing infiltration of outdoor air into the home. As approximately 43% of existing homes still have single-pane clear windows (~50 million houses) and millions of other homes have only double-pane clear windows (Cort 2013), improving window performance also presents a significant opportunity for energy savings in the residential sector. Today, various energy-saving window retrofit opportunities are available to homeowners, ranging from window coverings and storm panels to highly-insulating triple-pane R-5 window replacements. Many of these technologies have been evaluated in the field, in the “Lab Homes” at Pacific Northwest National Laboratory, and through modeling to prove their cost-effectiveness and performance in different climate regions. Recently, the Pacific Northwest’s Regional Technical Forum approved a utility measure for low- emissivity storm windows based on such data. This action represents a watershed moment for increasing the variety and prevalence of fenestration options in utility programs, especially for the low-income demographic. This paper will review various window retrofit options, the most recent field test and modeling data regarding their performance and cost-effectiveness, and discuss future rating efforts. This information is useful for utilities and energy-efficiency program managers to help effectively implement incentive measures for these technologies.

HVAC↗

Robust Large-Scale Dynamic Windows using Reversible Metal Electrodeposition

This project funded the study and development of dynamic windows based on reversible metal electrodeposition (RME). Dynamic windows allow user control over light and heat flow into and out of buildings, which offer both advantages in building aesthetics (with worker productivity improvement of 2%) and energy efficiency (up to 20% savings) compared to static controls such as low emissivity coatings and blinds/shades. Despite these advantages, dynamic windows, which traditionally rely on electrochromic metal oxides or conductive organic molecules for light modulation have failed to significantly impact the market due to issues related to cost, color, and optical dynamic range. Dynamic windows based on reversible metal electrodeposition (RME) are an exciting alternative approach and have the potential to overcome the issues associated with traditional technologies. A RME dynamic window is an electrochemical cell that modulates light using the reversible electrodeposition of metal on and off a transparent conducting oxide (TCO), which serves as the working electrode. The electrolyte has nearly colorless metal salts dissolved, and application of a cathodic potential on the TCO reduces the metal cations across the TCO surface to their metallic form, making a thin film that is efficient at blocking out light. A reverse in polarity oxidizes the metal, where it dissolves into solution, returning the window back to transparent. The counter electrode typically employed is a metal mesh, which is used to balance the electrochemical reactions happening on the TCO working electrode. These RME dynamic windows have the largest dynamic range (capable of reaching <<0.1% transmission) with color neutral tinting of any existing technology using solution processed techniques, which positions the technology as a promising candidate to penetrate the residential market. We have successfully scaled up the windows from 25 cm2 to 929 cm 2 , and we have demonstrated significant improvements to both the cycle life (10,000 cycles in a 3-electrode half-cell) and shelf life (>1 month) of our windows. We have published our work in high impact journals (6 published and 2 manuscripts in prep), filed 5 patents, and have incorporated TYNT Technologies to commercialize the technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dual-Zone Solar Control Indoor Shade: Demonstration at the Ronald V. Dellums Federal Building and U.S. Courthouse, 1301 Clay Street, Oakland, California and the Lawrence Berkeley National Laboratory Advanced Windows Testbed, Berkeley, California

Standard window shades are used to control sunlight, glare, window heat gains, and daylight. The challenge with conventional shades is that once the shades are lowered to reduce discomfort, daylight is reduced, which, in turn, increases the need for electric lighting. View is also obstructed, reducing the occupants’ connection to the outdoors. The strategy of subdividing the window wall and admitting daylight from above and controlling sunlight and view through the lower aperture can yield significant energy and peak demand savings over conventional shading systems, and improve the daylight quality of the indoor environment. This study evaluated a dual zone solar control (DZSC) shade with an upper, automated, horizontal, venetian blind with concave-up, matte white slats and a lower, manually operated, roller shade made of a transparent, reflective film. The automatic controls were designed to adjust the upper slat angle to maximize daylight to the room interior. The lower shade, when lowered, provided an unobstructed view to the outdoors. For the qualitative analysis, the DZSC shades were installed on windows in the southeast half of one floor in the Ronald V. Dellums Federal Building and U.S. Courthouse or hereafter referred to as the Oakland Federal Building (OFB) in Oakland, California. The position of the DZSC shades were observed and recorded periodically. Surveys were issued to occupants in the private offices and open plan workstations affected by the shades. For the quantitative analysis, the DZSC shades were installed in the south-facing windows of thermally isolated, fully instrumented, test chambers in the Advanced Windows Testbed at the Lawrence Berkeley National Laboratory (LBNL) in Berkeley, California. Measurements of window heat loads, daylight illuminance and environmental conditions related to visual and thermal comfort were collected over a six-month, solstice-to-solstice period. The performance of the DZSC shade was compared to fabric roller shades and venetian blinds since these are the two most common types of shades used in both commercial and Federal buildings. Several DZSC design permutations were evaluated: 1) manual or automated control of the upper louver system (“man” or “auto”) and 2) tinted or silvered reflective film for the lower shade (“Gray-Gray (GG)” or “Gray-Silver (GS)”1). The automated, reflective shade (auto-GS) reduced dimmable fluorescent lighting energy use by 51% and window cooling load by 13-15% compared to a conventional fabric roller shade with dual-pane, spectrally selective, low-e windows during the summer period (winter period was not measured). Qualitative analysis revealed that the auto-GS shade was preferred by 80% of the survey respondents compared to the existing vertical fabric blinds with single-pane, tinted windows in the occupied building. Survey results indicated that visual discomfort was reduced and thermal discomfort was also reduced during warm or hot weather. Occupants expressed greater satisfaction with the unobstructed view. Installation and commissioning of the DZSC shades was fairly straightforward with some minor problems due to inadequate installation instructions and improper wiring. A few occupants expressed dissatisfaction with the automatic controls for the upper louvers due to visual discomfort, erroneous control, and motor noise.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Interoperability through standardization: Electronic mail, and X Window systems

Since the introduction of computing machines, there has been continual advances in computer and communication technologies and approaching limits. The user interface has evolved from a row of switches, character based interface using teletype terminals and then video terminals, to present day graphical user interface. It is expected that next significant advances will come in the availability of services, such as electronic mail and directory services, as the standards for applications are developed and in the 'easy to use' interfaces, such as Graphical User Interface for example Window and X Window, which are being standardized. Various proprietary electronic mail (email) systems are in use within organizations at each center of NASA. Each system provides email services to users within an organization, however the support for email services across organizations and across centers exists at centers to a varying degree and is often easy to use. A recent NASA email initiative is intended 'to provide a simple way to send email across organizational boundaries without disruption of installed base.' The initiative calls for integration of existing organizational email systems through gateways connected by a message switch, supporting X.400 and SMTP protocols, to create a NASA wide email system and for implementation of NASA wide email directory services based on OSI standard X.500. A brief overview of MSFC efforts as a part of this initiative are described. Window based graphical user interfaces make computers easy to use. X window protocol has been developed at Massachusetts Institute of Technology in 1984/1985 to provide uniform window based interface in a distributed computing environment with heterogenous computers. It has since become a standard supported by a number of major manufacturers. Z Windows systems, terminals and workstations, and X Window applications are becoming available. However impact of its use in the Local Area Network environment on the network traffic are not well understood. It is expected that the use of X Windows systems will increase at MSFC especially for Unix based systems. An overview of X Window protocol is presented and its impact on the network traffic is examined. It is proposed that an analytical model of X Window systems in the network environment be developed and validated through the use of measurements to generate application and user profiles.

Amin, Ashok T.↗

An Investigation of Strategies for Sensing Window Attachment Position: Survey of Candidate Technologies, Evaluation, and Deployment Recommendations

While windows are desirable feature in buildings for views, daylighting, and aesthetics, it is important to recognize that windows are a major contributor to a building’s energy load. Interior window coverings, such as shades and blinds, can help improve the energy performance of windows without sacrificing the benefits; however, while appropriate use of window coverings provide the potential for energy savings, there is little consensus regarding how occupants typically use these window attachments, which sometimes puts into question how much energy they actually save in an occupied home. Automated shading control strategies can reduce the uncertainty of energy savings; however, users can overwrite pre-defined schedules or write their own shade control programs to reach their personal comfort and privacy goals. Because it is difficult to identify how occupants interact with window shades, it is difficult to identify the energy savings potential of blinds. To address this problem, this study was developed to identify a candidate sensor that can be deployed to sense blind position. The intended application for this sensor is deployment in energy efficiency field studies so that shade usage can be measured to better understand results and identify the energy impact of specific window attachment technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Parametric study of solid-solid translucent phase change materials in building windows

Thermal energy storage and solar radiation management are crucial to improve the sustainability and energy efficiency of buildings. Compared with the implementation of phase change materials (PCMs) in opaque components, the energy saving potential of incorporating PCMs in transparent glazing windows is much less studied and not well understood. Here we present a comprehensive parametric study of novel PCM windows for building energy saving with a focus on optimizing and quantitatively distinguishing the contributions from the optical and thermal properties of the PCM, which is particularly useful for the design of solid-solid PCM windows. We investigate a reference commercial office building using EnergyPlus by developing an equivalent model of our PCM window that is compatible with EnergyPlus's modeling capabilities. Compared with a clear-clear double-pane window, the integration of 3 mm solid-solid PCMs with optimal properties in warm, mixed, and cold climates can respectively save up to 17.2%, 14.0%, and 5.8% energy for the HVAC (heating, ventilation, and air conditioning) system, and 9.4%, 6.7%, and 3.2% energy for the whole building. We also demonstrate that these energy savings are most sensitive to the solar absorptance of PCMs for all three climates. The optimal transition temperature varies with climate and is related to the climate and solar radiation heat gain. Other issues are also briefly discussed, such as hysteresis, window orientations, and the effect of interior lighting. Finally, although the optimal PCM windows show energy saving performance comparable with low-emissivity windows, the PCM windows provide a unique advantage in terms of shifting HVAC loads which can provide benefits to the electrical grid.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗