Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “WOUNDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Structural Health Monitoring of Composite Wound Pressure Vessels

The increasing use of advanced composite materials in the wide range of applications including Space Structures is a great impetus to the development of smart materials. Incorporating these FBG sensors for monitoring the integrity of structures during their life cycle will provide valuable information about viability of the usage of such material. The use of these sensors by surface bonding or embedding in this composite will measure internal strain and temperature, and hence the integrity of the assembled engineering structures. This paper focuses on such a structure, called a composite wound pressure vessel. This vessel was fabricated from the composite material: TRH50 (a Mitsubishi carbon fiber with a 710-ksi tensile strength and a 37 Msi modulus) impregnated with an epoxy resin from NEWPORT composites (WDE-3D-1). This epoxy resin in water dispersed system without any solvents and it cures in the 240-310 degrees F range. This is a toughened resin system specifically designed for pressure applications. These materials are a natural fit for fiber sensors since the polyimide outer buffer coating of fiber can be integrated into the polymer matrix of the composite material with negligible residual stress. The tank was wound with two helical patterns and 4 hoop wraps. The order of winding is: two hoops, two helical and two hoops. The wall thickness of the composite should be about 80 mil or less. The tank should burst near 3,000 psi or less. We can measure the actual wall thickness by ultrasonic or we can burst the tank and measure the pieces. Figure 1 shows a cylinder fabricated out of carbon-epoxy composite material. The strain in different directions is measured with a surface bonded fiber Bragg gratings and with embedded fiber Bragg gratings as the cylinder is pressurized to burst pressures. Figure 2 shows the strain as a function of pressure of carbon-epoxy cylinder as it is pressurized with water. Strain is measured in different directions by multiple gratings oriented in both axial and hoops directions.

Joseph Grant↗

Time-Temperature Dependent Response of Filament Wound Composites for Flywheel Rotors

Flywheel energy storage offers an attractive alternative to battery systems used in space applications such as the International Space Station. Rotor designs capable of high specific energies benefit from the load carrying capacity of hoop wound carbon fibers but their long-term durability may be limited by time-temperature dependent radial deformations. This was investigated for the carbon/epoxy rotor material, IM7/8552. Coupon specimens were sectioned from filament wound panels. These were tested in compression and tension at room temperature (RT), 95 and 135 C for strain rates from 5x10(exp -6) per second to 5x10(exp -3) per second. Time, temperature and load sign dependent effects were significant transverse to the fiber. At -0.5 percent strain for 72 hr, compressive stresses relaxed 16.4 percent at 135 C and 13 percent at 95 C. Tensile stresses relaxed only 7 percent in 72 hr at 135 C for 0.5 percent strain. Using linear hereditary material response and Boltzmann s principle of superposition to describe this behavior is problematic if not intractable. Micromechanics analysis including the effects of processing residual stresses is needed to resolve the paradoxes. Uniaxial compressive stress relaxation data may be used to bound the loss of radial pre-load stresses in flywheel rotors.

Thesken, John C.↗

Somatic proembryo production from excised, wounded zygotic carrot embryos on hormone-free medium: evaluation of the effects of pH, ethylene and activated charcoal

Wounded zygotic embryos of cultivated carrot produce somatic proembryos on hormone-free nutrient medium containing 1 mM NH4+ as the sole nitrogen source. Continued maintenance of proembryos on this medium leads to a "pure" culture of preglobular stage proembryos (PGSPs). Ethylene had no effect on this process. Also, somatic embryo production was not affected by growing cultures on activated charcoal-impregnated filter papers. However, somatic proembyros initiated on activated charcoal papers were not maintainable as PGSPs and developed into later embryo stages. Normally, medium pH dropped from 5.7 to 4 during each subculture period, but when using activated charcoal papers the pH endpoint was around 6 - 7 due to a leachable substance(s) within the filter papers. When powdered, activated charcoal was used in the medium as an adsorbent of products potentially released after wounding, pH dropped at the normal rate and to the expected levels; proembryos did not mature into later embryo stages and were maintainable exclusively as PGSPs. Low pH (approximately 4) is detrimental to proembyro production, but is essential to maintaining PGSPs on hormone-free nutrient medium, whereas a sustained pH > or = 5.7 allows continued development of PGSPs into later embryo stages.

NASA Program Space Biology↗

Hybrid Wound Filaments for Greater Resistance to Impacts

A hybrid material containing wound filaments made of a hybrid of high-strength carbon fibers and poly(phenylene benzobisoxazole) [PBO] fibers is discussed. This hybrid material is chosen in an effort to increase the ability of the pressure vessel to resist damage by low-speed impacts (e.g., dropping of tools on the vessel or bumping of the vessel against hard objects during installation and use) without significantly increasing the weight of the vessel. While the basic concept of hybridizing fibers in filament-wound structures is not new, the use of hybridization to increase resistance to impacts is an innovation, and can be expected to be of interest in the composite-pressure-vessel industry. The precise types and the proportions of the high-strength carbon fibers and the PBO fibers in the hybrid are chosen, along with the filament-winding pattern, to maximize the advantageous effects and minimize the disadvantageous effects of each material. In particular, one seeks to (1) take advantage of the ability of the carbon fibers to resist stress rupture while minimizing their contribution to vulnerability of the vessel to impact damage and (2) take advantage of the toughness of the PBO fibers while minimizing their contribution to vulnerability of the vessel to stress rupture. Experiments on prototype vessels fabricated according to this concept have shown promising results. At the time of reporting the information for this article, research toward understanding and optimizing the performances of PBO fibers so as to minimize their contribution to vulnerability of the pressure vessel to stress rupture had yet to be performed.

DeLay, Thomas K.↗

Design and Metamodel-Based Optimization of a High Power Density Wound Field Traction Motor

Traction motors onboard electric vehicles (EVs) are faced with ever-increasing power density requirements and cost reduction challenges. Although permanent magnet (PM) traction motors have been favored for their potential of higher power densities, the price and supply volatilities of PM materials are the major drawbacks. Instead of a single load point, the performance of a traction motor needs to be optimized over various combinations of torque and speed to represent real-world vehicular driving scenarios, which tends to be a time-consuming task with direct optimizations. In this paper, as a PM-free solution, a wound field synchronous motor (WFSM) is designed and optimized using a metamodel-based approach to maximize its efficiency over a custom set of load points, while utilizing a fully per-unitized geometry template. The workflow has proven to be timesaving and the selected design is prototyped.

33 ADVANCED PROPULSION SYSTEMS↗

Implementation of a Metamodel-Based Optimization for the Design of a High Power Density Wound Field Traction Motor

Traction motors onboard electric vehicles (EVs) are faced with ever-increasing power density requirements and cost reduction challenges. Although permanent magnet (PM) traction motors have been favored for their potential of higher power densities, the price and supply volatility of PM materials are the major drawbacks. Instead of a single load point, the performance of a traction motor needs to be optimized over various combinations of torque and speed to represent real-world vehicular driving scenarios, which tends to be a time-consuming task with direct optimizations. In this study, as a PM-free solution, a wound field synchronous motor (WFSM) is designed and optimized using a metamodel-based approach to maximize its efficiency over a custom set of load points, while utilizing a fully per-unitized geometry template. The workflow has proven to be timesaving and the optimal design is prototyped and tested.

33 ADVANCED PROPULSION SYSTEMS↗

Modeling and simulation of gas separations with spiral–wound membranes

Models for gas separations with spiral–wound membranes are developed and found to exhibit good agreement with experiments performed on N 2 /O 2 mixtures. The two–dimensional (2D) model can be accurately approximated by a one–dimensional (1D) surrogate model when the spacer widths are chosen to make the channel pressure drops small. Subsequently, the separation of propane/propylene mixtures from the recycle purge stream of a polypropylene reactor is investigated. Assuming ideal gas is found to lead to significant overestimations in membrane stage cuts (sometimes more than 10%), an extent comparable to that associated with extrapolating constant olefin permeance from a low–pressure condition. While olefin permeance can change significantly with pressure, using a constant–permeance formulation can result in a small (< 2.5%) underprediction in stage cut if the value for the permeance is taken from the feed condition. Finally, membrane properties and costs necessary for a viable separation process are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Field Quality Modeling in Canted Cosine Theta Dipole Magnets Wound Using REBCO Cables

In accelerator magnets the magnetic field quality is an important parameter. Using REBCO tapes or cables in magnet windings affects the magnetic field quality because of a quite high magnetization generated by these conductors. In this paper we analyzed numerically (using FEM) an effect of various REBCO cables’ magnetization on the field quality of canted cosine theta (CCT) dipole magnets. The magnetic properties of the cables were taken from our measurements of their M (H) curves at 4.2 K and magnetic fields up to 12 T. Also, flux creep effects were measured and their effects on field quality analyzed. Here we present a modeling of a CCT magnet containing 1 dipole double layer wound using a CORC and STAR cable. To make the FEM modeling less computationally “expensive”, we modelled only a section of 10 turns of the magnet's central part and calculated b3 fields on a circle of 2/3 of the innermost layer center line. Special M (H) curves measured during various field cycles (the so called “pre-injection cycles”) are effective in decreasing b 3 fields of the magnets. Flux creep effects suppress the b 3 fields further. In conclusion, using these techniques b 3 fields less than 10 units can be achieved.

36 MATERIALS SCIENCE↗

Current and Future Work on Wound Contamination by Alpha Emitters at Los Alamos [Slides]

Our team calculated ‘clinical decision levels’ at which treatment may be warranted (i.e., bioassay and wound measurements which correspond to specific dose thresholds). The actual risk to the patient corresponding to this dose threshold is uncertain – the CED may not tell the whole story. We recently reviewed LANL medical records to characterize adverse events associated with treatment. Future work should include medical records from other institutions and a review and analysis of data to quantify benefit of treatment with a focus on the question, "What factors predict whether treatment will be beneficial?"

61 RADIATION PROTECTION AND DOSIMETRY↗

Wound-Field Synchronous Machine-System Integration toward 8X Power Density and Commercialization

In support of VTO's Electric Drive R&D activity, the Electric Drive Technologies (EDT) Consortium, a multi-disciplinary team of national labs and universities, coordinates and conducts a portfolio of research to advance the state-of-the-art in electric drive technologies. The Consortium established the following strategic goal listed below: (EDT Research Consortium Strategic Goal (compared to 2015 baseline)) A 125K electric traction drive system: (1) 8X power density improvement, or 1/10 the volume (33 kW/L), (2) 1/2 the cost ($\$$3.3/kW), (3) 2X useful life (300,000 miles), and (4) 100 kW/L inverter and a <20,000 rpm, 50kW/L electric motor The objective of this project is to design a Wound Field Synchronous Machine with 8X power density improvement and cost below $\$$3.3/kW.

42 ENGINEERING↗