Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Volumetric”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Increasing the volumetric efficiency of Diesel engines by intake pipes

Development of a method for calculating the volumetric efficiency of piston engines with intake pipes. Application of this method to the scavenging pumps of two-stroke-cycle engines with crankcase scavenging and to four-stroke-cycle engines. The utility of the method is demonstrated by volumetric-efficiency tests of the two-stroke-cycle engines with crankcase scavenging. Its practical application to the calculation of intake pipes is illustrated by example.

List, Hans↗

BOREAS HYD-1 Volumetric Soil Moisture Data

The Boreal Ecosystem-Atmosphere Study (BOREAS) Hydrology (HYD)-1 team made measurements of volumetric soil moisture at the Southern Study Area (SSA) and Northern Study Area (NSA) tower flux sites in 1994 and at selected tower flux sites in 1995-97. Different methods were used to collect these measurements, including neutron probe and manual and automated Time Domain Reflectometry (TDR). In 1994, the measurements were made every other day at the NSA-OJP (Old Jack Pine), NSA-YJP (Young Jack Pine), NSA-OBS (Old Black Spruce), NSA-Fen, SSA-OJP, SSA-YJP, SSA-Fen, SSA-YA (Young Aspen), and SSA-OBS sites. In 1995-97, when automated equipment was deployed at NSA-OJP, NSA-YJP, NSA-OBS, SSA-OBS, and SSA-OA (Old Aspen), the measurements were made as often as every hour. The data are stored in tabular ASCII files. The volumetric soil moisture data are available from the Earth Observing System Data and Information System (EOSDIS) Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC). The data files are available on a CD-ROM (see document number 20010000884).

Cuenca, Richard H.↗

On Utilization of NEXRAD Scan Strategy Information to Infer Discrepancies Associated With Radar and Rain Gauge Surface Volumetric Rainfall Accumulations

To evaluate the Tropical Rainfall Measuring Mission (TRMM) monthly Ground Validation (GV) rain map, 42 quality controlled tipping bucket rain gauge data (1 minute interpolated rain rates) were utilized. We have compared the gauge data to the surface volumetric rainfall accumulation of NEXRAD reflectivity field, (converting to rain rates using a 0.5 dB resolution smooth Z-R table). The comparison was carried out from data collected at Melbourne, Florida during the month of July 98. GV operational level 3 (L3 monthly) accumulation algorithm was used to obtain surface volumetric accumulations for the radar. The gauge records were accumulated using the 1 minute interpolated rain rates while the radar Volume Scan (VOS) intervals remain less than or equal to 75 minutes. The correlation coefficient for the radar and gauge totals for the monthly time-scale remain at 0.93, however, a large difference was noted between the gauge and radar derived rain accumulation when the radar data interval is either 9 minute, or 10 minute. This difference in radar and gauge accumulation is being explained in terms of the radar scan strategy information. The discrepancy in terms of the Volume Coverage Pattern (VCP) of the NEXRAD is being reported where VCP mode is ascertained using the radar tilt angle information. Hourly radar and gauge accumulations have been computed using the present operational L3 method supplemented with a threshold period of +/- 5 minutes (based on a sensitivity analysis). These radar and gauge accumulations are subsequently improved using a radar hourly scan weighting factor (taking ratio of the radar scan frequency within a time bin to the 7436 total radar scans for the month). This GV procedure is further being improved by introducing a spatial smoothing method to yield reasonable bulk radar to gauge ratio for the hourly and daily scales.

Roy, Biswadev↗

Investigation of Volumetric Sources in Airframe Noise Simulations

Hybrid methods for the prediction of airframe noise involve a simulation of the near field flow that is used as input to an acoustic propagation formula. The acoustic formulations discussed herein are those based on the Ffowcs Williams and Hawkings equation. Some questions have arisen in the published literature in regard to an apparently significant dependence of radiated noise predictions on the location of the integration surface used in the solution of the Ffowcs Williams and Hawkings equation. These differences in radiated noise levels are most pronounced between solid-body surface integrals and off-body, permeable surface integrals. Such differences suggest that either a non-negligible volumetric source is contributing to the total radiation or the input flow simulation is suspect. The focus of the current work is the issue of internal consistency of the flow calculations that are currently used as input to airframe noise predictions. The case study for this research is a computer simulation for a three-element, high-lift wing profile during landing conditions. The noise radiated from this flow is predicted by a two-dimensional, frequency-domain formulation of the Ffowcs Williams and Hawkings equation. Radiated sound from volumetric sources is assessed by comparison of a permeable surface integration with the sum of a solid-body surface integral and a volume integral. The separate noise predictions are found in good agreement.

Casper, Jay H.↗

Volumetric Acoustic Vector Intensity Probe

A new measurement tool capable of imaging the acoustic intensity vector throughout a large volume is discussed. This tool consists of an array of fifty microphones that form a spherical surface of radius 0.2m. A simultaneous measurement of the pressure field across all the microphones provides time-domain near-field holograms. Near-field acoustical holography is used to convert the measured pressure into a volumetric vector intensity field as a function of frequency on a grid of points ranging from the center of the spherical surface to a radius of 0.4m. The volumetric intensity is displayed on three-dimensional plots that are used to locate noise sources outside the volume. There is no restriction on the type of noise source that can be studied. The sphere is mobile and can be moved from location to location to hunt for unidentified noise sources. An experiment inside a Boeing 757 aircraft in flight successfully tested the ability of the array to locate low-noise-excited sources on the fuselage. Reference transducers located on suspected noise source locations can also be used to increase the ability of this device to separate and identify multiple noise sources at a given frequency by using the theory of partial field decomposition. The frequency range of operation is 0 to 1400Hz. This device is ideal for the study of noise sources in commercial and military transportation vehicles in air, on land and underwater.

Klos, Jacob↗

CO2 Capacity Sorbent Analysis Using Volumetric Measurement Approach

In support of air revitalization system sorbent selection for future space missions, Ames Research Center (ARC) has performed CO2 capacity tests on various solid sorbents to complement structural strength tests conducted at Marshall Space Flight Center (MSFC). The materials of interest are: Grace Davison Grade 544 13X, Honeywell UOP APG III, LiLSX VSA-10, BASF 13X, and Grace Davison Grade 522 5A. CO2 capacity was for all sorbent materials using a Micromeritics ASAP 2020 Physisorption Volumetric Analysis machine to produce 0 C, 10 C, 25 C, 50 C, and 75 C isotherms. These data are to be used for modeling data and to provide a basis for continued sorbent research. The volumetric analysis method proved to be effective in generating consistent and repeatable data for the 13X sorbents, but the method needs to be refined to tailor to different sorbents.

Huang, Roger↗

CO2 Capacity Sorbent Analysis Using Volumetric Measurement Approach

In support of air revitalization system sorbent selection for future space missions, Ames Research Center (ARC) has performed CO2 capacity tests on various solid sorbents to complement structural strength tests conducted at Marshall Space Flight Center (MSFC). The materials of interest are: Grace Davison Grade 544 13X, Honeywell UOP APG III, LiLSX VSA-10, BASF 13X, and Grace Davison Grade 522 5A. CO2 capacity was for all sorbent materials using a Micromeritics ASAP 2020 Physisorption Volumetric Analysis machine to produce 0C, 10C, 25C, 50C, and 75C isotherms. These data are to be used for modeling data and to provide a basis for continued sorbent research. The volumetric analysis method proved to be effective in generating consistent and repeatable data for the 13X sorbents, but the method needs to be refined to tailor to different sorbents.

Air Revitalization↗

Volumetric Assessment of UPRITE Exercises From Marker-Based Motion Capture

Lack of volumetric data on full-body movement exercises presents a challenge to ensuring the fit of crew members’ full range of motion on the International Space Station (ISS). The Upright Proprioception Retention via In-flight Training and Evaluation (UPRITE) is a sensorimotor countermeasure device designed for maintaining crew members’ proprioception in a microgravity environment (Figure 1). This work compares differences between data collection-based “high-fidelity” volumes and a “cone volume” with simplified assumptions (95th percentile in stature human standing on UPRITE while tilted and revolved around vertical axis). Objective: To provide the spatial parameters of exercises on the UPRITE such that it is placed on the ISS according to its volumetric demands or that usage is adjusted to fit the available space.

L D Quinto↗

System and method for in situ volumetric sensing of 3D cure state of resin being used in an additive manufacturing system

An in situ cure monitoring control system for use with a volumetric three dimensional (3D) printing system, wherein the volumetric 3D system includes a container defining a build volume, the container includes a photocurable resist used for making a 3D part, and the resist is responsive to an optical curing beam from a light source, which is controlled by a controller, and which is passed through the resist. The cure monitoring control system includes an optical signal source which generates optical signals having a wavelength selected in relation to a characteristic of the resist, and directed to pass through the build volume. A detector detects the optical signals and generates output signals in accordance therewith. Software monitors the output signals and uses the output signals to modify the curing beam to help optimize curing of the resist.

Panas, Robert Matthew↗

Virtual Volumetric Additive Manufacturing (VirtualVAM)

Abstract Tomographic volumetric additive manufacturing (VAM) produces arbitrary 3D geometries by exposure of a rotating volume of photopolymer resin to tomographically‐patterned illumination. This enables high speed, layer‐less printing of parts from a wide range of photopolymers not amenable to layer‐by‐layer processes. Since the entire geometry is produced at once over the course of a few seconds to minutes, molecular diffusion length scales become significant to the printing process. Understanding these molecular reaction and diffusion processes is imperative for advancing VAM to a usable technology. These processes are experimentally very difficult to monitor and measure. Herein, VirtualVAM ‐ a simulation framework for modeling the tomographic VAM process, is developed and experimentally validated. VirtualVAM simulates reaction, diffusion, and heat generation processes over the course of a print with single‐voxel resolution. From a few experimentally‐determined input parameters and a set of images for projection, VirtualVAM is able to generate a large spatio‐temporal data set for any given tomographic VAM print. Using VirtualVAM, a number of experimentally‐unattainable aspects of the VAM process are investigated such as single‐voxel conversion profiles, effect of molecular oxygen, and stopping time determination. VirtualVAM also enables the optimization of exposure patterns to further improve contrast between in‐part and out‐of‐part delivered dose.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Volumetric Additive Manufacturing of Dicyclopentadiene by Solid‐State Photopolymerization

Polymerization in the solid state is generally infeasible due to restrictions on mobility. However, in this work, the solid-state photopolymerization of crystalline dicyclopentadiene is demonstrated via photoinitiated ring-opening metathesis polymerization. The source of mobility in the solid state is attributed to the plastic crystal nature of dicyclopentadiene, which yields local short-range mobility due to orientational degrees of freedom. Polymerization in the solid state enables photopatterning, volumetric additive manufacturing of free-standing structures, and fabrication with embedded components. Solid-state photopolymerization of dicyclopentadiene offers a new paradigm for advanced and freeform fabrication of high-performance thermosets.

additive manufacturing↗

Volumetric Additive Manufacturing of Dormant Catalytic Chemistries to Generate Silicone Micro‐ and Millifluidic Devices and Instant Molds

Tomographic volumetric additive manufacturing (T‐VAM) rapidly prints solid objects within minutes, accessing photochemistries that are traditionally challenging for layer‐based additive manufacturing methods. This includes high‐viscosity materials, air‐free chemistries, and solid‐state systems. Catalytic chemistries are appealing as a pathway to engineering advanced materials, including tough thermosets, silicone elastomers, and complex block copolymers. However, photoactivated dormant catalytic chemistries, where the catalyst irreversibly activates upon exposure to light, are incompatible with typical tomographic VAM approaches. To address this limitation, a zero‐dose optimization strategy is devised to preserve dormant catalysts in desired regions by keeping them unexposed to light. VAM printed micro‐ and millifluidic devices and instant molds are successfully produced within minutes in silicones polymerized using photoactivated dormant platinum photohydrosilylation catalysts. The printed channels are programmed to be 500 and 2500 µm for the micro‐ and millifluidic devices, and print fidelity is assessed by X‐ray computed tomography. This work demonstrates the potential of zero‐dose optimization to expand the range of chemistries accessible for VAM, enabling the rapid fabrication of complex devices.

Additive Manufacturing↗

Phase field-volumetric lattice Boltzmann model of ion uptake in porous nuclear waste form materials under continuous flow

The flow field within the mesopores of sorbent particles plays a crucial role in radionuclide diffusion and ion uptake kinetics, thus, impacting the overall performance of porous nuclear waste form materials. To fundamentally understand the influence of microstructures and material properties on the radionuclide absorption and retention processes requires a coupled multi-physics model that considers the advection and diffusion within the flow field, the reaction at liquid-solid interfaces, and finally, the solid-state diffusion within a complex nanoporous medium. Here, this study employs the volumetric lattice Boltzmann method (VLBM) to accurately and efficiently calculate the steady state velocity field inside the mesopores of sorbent particles. The obtained velocity field is then utilized to calculate the advection of ions in the steady flow. A phase field (PF) model of ion uptake is used to describe the reaction occurring at the solid-liquid interface and diffusion inside the porous medium. The integrated PF-VLBM model is verified in terms of the mass conservation and numerical efficiency and validated qualitatively with experimental observation data. Then, it is applied to study the influence of thermodynamic and kinetic properties, as well as flow field conditions on the ion uptake kinetics. The numerical results demonstrate that the ion uptake kinetics in porous particles has three distinct stages, which is in agreement with the observations in continuous flow experiments. In the first stage, the kinetics is predominantly controlled by the flow field and ion diffusivity in the liquid phase. The kinetics in the second stage is primarily governed by ion diffusivity in the solid phase. In the third stage the system reaches a dynamic equilibrium with a net zero uptake flux at the interface. It is also found that porous structures significantly affect the efficiency and capacity of ion uptake. The simulation results can help to understand the physics behind the observed ion uptake kinetics in experiments and to facilitate the development of constitutive equations that can account for heterogeneous microstructures in engineering performance codes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Achieving high volumetric EDLC carbons via hydrothermal carbonization and cyclic activation

A novel activation method involving hydrothermal carbonization (HTC) and a pressure-induced low temperature oxidation has been demonstrated for cellulose derived HTC char by using hydrogen peroxide as an active di-oxygen source. The optimized porosity versus gravimetric capacitance results from cellulose derived HTC char synthesized at 220 °C. Almost homogeneous and small particle size micro-ellipse/sphere, relatively high surface area and narrow pore size distributions lead to a high bulk density, i.e. 0.73 g cm -3 , of coating type electrodes, which is much denser than those manufactured from steam activated carbons for supercapacitor industry, i.e., 0.52 g cm -3 . The resulting carbon prepared herein achieves a relatively high volumetric capacitance in an organic electrolyte-based supercapacitor reaching a competitive value of industrial system with the features of environment friendly, cost-effective as well as high yield, and less energy consumption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optical Imaging Methods for Volumetric Additive Manufacturing

Tomographic volumetric additive manufacturing (VAM) is a technique that enables light-induced curing of photoresins into complex 3D end use objects within a single step. This is made possible through projecting tomographically patterned light energy into a photo-curable resin volume within a rotating container. In order to monitor, quantify, and control curing during tomographic VAM, researchers need to visualize the curing parts in real-time. This may enable advancements toward dynamic, controlled and closedloop VAM methods in the future, as some researchers have shown. Herein we briefly review various optical imaging methods used to monitor printing in real-time, as well as provide some perspectives for future needs and considerations for imaging methods in VAM.

36 MATERIALS SCIENCE↗

Tomographic Volumetric Additive Manufacturing of Silica Glass with In Situ Error Calculation and Projection Tiling

The optical, thermal, and chemical properties of glass make it an ideal material for use in a wide range of applications, from optics and chemistry reactionware to consumer products. Tomographic volumetric additive manufacturing (tVAM) creates 3D objects by selectively gelling material within a rotating vial of photo-sensitive material by exposure to a series of tomographically-determined images. Here, in this study, tVAM is investigated for fabrication of complex, centimeter-scale, 3D silica glass parts. By optimizing the post-processing procedure, fully-dense glass parts with up to 2 cm 2 cross sectional area are achieved. The changes in optical properties during printing are leveraged for in situ metrology during printing, and the non-Newtonian nature of the glass-filled photoresin system to facilitate larger fabrication volumes via tiled projections. Printed structures are finally demonstrated for applications as MEMS components, optics, fluidics, and consumer products.

Materials science↗

Development of transparent, particle‐loaded photoresins for volumetric additive manufacturing of silica glass

Abstract Additive manufacturing of glass aims to change the paradigm of glass manufacturing by allowing for improved customization coupled with lower energy and post‐processing needs. Fabrication of glass via volumetric additive manufacturing (VAM) involves printing in a silica‐loaded photopolymer resin with subsequent thermal processing and adds additional advantages by allowing for rapid printing of parts with smooth surfaces and no supports. Previous work in glass VAM has demonstrated fabrication of optical quality microoptics with overall dimensions on the scale of tens of cubic millimeters. For applications requiring glass printed on the scale of cubic centimeters the rheology, scattering, and green part strength must be controlled via resin formulation. Here, we present insight into a novel glass photopolymer resin suitable for VAM and in the effect of tuning formulation on the ability to produce dense glass parts with volumes on the scale of cubic centimeters.

Myers, Luke A.↗

Beyond Taylor’s hypothesis: a novel volumetric reconstruction of velocity and density fields for variable‑density and shear flows

Abstract This work presents a novel numerical procedure for reconstructing volumetric density and velocity fields from planar laser-induced fluorescence (PLIF) and stereoscopic particle image velocimetry (SPIV) data. This new method is theoretically and practically demonstrated to provide more accurate 3D vortical structures and density fields in high shear flows than reconstruction methods based on the mean convective velocity. While Taylor’s hypothesis of frozen turbulence is commonly applied by using the local mean streamwise velocity, the proposed algorithm uses the measured local instantaneous velocity for data convection. It consists of a step-by-step reconstruction based on a mixed Lagrangian–Eulerian solver that includes the 3D interpolation of scattered flow data and that relaxes the Taylor’s hypothesis by iterative enforcement of the incompressibility constraint on the velocity field. This methodology provides 3D fields with temporal resolution, spatial resolution, and accuracy comparable to that of real 3D snapshots, thus providing a practical alternative to tomographic measurements. The procedure is validated using numerical data of the constant-density channel flow available on the Johns Hopkins University Turbulence Database (JHTDB), showing the accurate reconstruction of the 3D velocity field. The algorithm is applied to an experimental dataset of PLIF and SPIV measurements of a variable-density jet flow, demonstrating its capability to provide 3D velocity and density fields that are more consistent with the Navier–Stokes equations compared to the mean flow convective method. Graphic abstract

42 ENGINEERING↗