Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Vacuum chambers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Simulation and measurement of beam-induced heating of ceramic vacuum chambers

In this article, we summarize recent theoretical and experimental studies of the impedance and beam-induced heating of titanium-coated ceramic vacuum chambers used in the NSLS-II injection kickers. The impedance was calculated using the field matching theory assuming planar approximation and compared with the mpedanceake2 code. For the coating thickness of a few microns, we demonstrated that the beam-induced power is dissipated in the titanium coating and that the longitudinally averaged two-dimensional power density is approximated by an analytical expression, thus allowing the use of a simplified model of the power density as input for the code to simulate the temperature distribution with realistic nonuniform thickness of the Ti coating. For a few values of the NSLS-II beam current, we measured the beam-induced heating of two ceramic chambers using thermal sensors installed along the chamber and compared the measurement results with the simulations. Published by the American Physical Society 2024

36 MATERIALS SCIENCE↗

Cleaning of a thermal vacuum chamber with shrouds in place

In February, 1991, a failure of a rotary booster pump caused the diffusion pumps to backstream into a 10 ft x 15 ft thermal vacuum chamber. Concerns existed about the difficulty of removing and reinstalling the shrouds without causing leaks. The time required for the shroud removal was also of concern. These concerns prompted us to attempt to clean the chamber without removing the shrouds.

Bond, William R.↗

Thermal vacuum chamber shroud performance with gaseous nitrogen cooling

The results are presented for calculations of shroud surface temperature for various flow rates of gaseous nitrogen through the liquid nitrogen shrouds of a large thermal vacuum chamber. The conditions imposed provide conservative bounds for Mars surface simulation inside the chamber during thermal testing of an appropriate test object. It is shown that the shroud surfaces seen by the object can be held within an acceptable temperature range by providing a reasonable flow of gaseous nitrogen to the shrouds at a reasonable pressure, and that no change to the present shroud system need be made which would affect its suitability for liquid nitrogen cooling.

Farmer, R. A.↗

Preparation of a Frozen Regolith Simulant Bed for ISRU Component Testing in a Vacuum Chamber

In-Situ Resource Utilization (ISRU) systems and components have undergone extensive laboratory and field tests to expose hardware to relevant soil environments. The next step is to combine these soil environments with relevant pressure and temperature conditions. Previous testing has demonstrated how to incorporate large bins of unconsolidated lunar regolith into sufficiently sized vacuum chambers. In order to create appropriate depth dependent soil characteristics that are needed to test drilling operations for the lunar surface, the regolith simulant bed must by properly compacted and frozen. While small cryogenic simulant beds have been created for laboratory tests, this scale effort will allow testing of a full 1m drill which has been developed for a potential lunar prospector mission. Compacted bulk densities were measured at various moisture contents for GRC-3 and Chenobi regolith simulants. Vibrational compaction methods were compared with the previously used hammer compaction, or "Proctor", method. All testing was done per ASTM standard methods. A full 6.13 m3 simulant bed with 6 percent moisture by weight was prepared, compacted in layers, and frozen in a commercial freezer. Temperature and desiccation data was collected to determine logistics for preparation and transport of the simulant bed for thermal vacuum testing. Once in the vacuum facility, the simulant bed will be cryogenically frozen with liquid nitrogen. These cryogenic vacuum tests are underway, but results will not be included in this manuscript.

Klenhenz, Julie↗

Skipper CCD Long-Term Vacuum Chamber

The Skipper CCD is a high-sensitivity Charge Coupled Device (CCD) sensor designed at Fermilab that has extremely low readout noise. The Skipper can only be operated at pressures below 10-4Torr (about a millionth of an atmosphere). The purpose of this project was to investigate whether a long-term vacuum chamber could be used for the Skipper CCD, which would require only being re-pumped once a year. This would allow the Skipper to be fully integrated here at Fermilab and then be transported anywhere for immediate use.

Struven, Wolfgang↗

Thermal Vacuum Chamber Repressurization with Instrument Purging

At the conclusion of cryogenic vacuum testing of the James Webb Space Telescope Optical Telescope Element Integrated Science Instrument Module (JWST-OTIS) in NASA Johnson Space Center’s (JSCs) thermal vacuum (TV) Chamber A, contamination control (CC) engineers are postulating that chamber particulate material stirred up by the repressurization process may be kept from falling into the Integrated Science Instrument Module (ISIM) interior to some degree by activating instrument purge flows over some initial period before opening the chamber valves. This manuscript describes development of a series of models designed to describe this process. The models are strung together in tandem with a fictitious set of conditions to estimate overpressure evolution from which net outflow velocity behavior may be obtained. Creeping flow assumptions are then used to determine the maximum particle size that may be kept suspended above the ISIM aperture, keeping smaller particles from settling within the instrument module.

Repressurization↗

Static Testing of A Conductively-Cooled, High Temperature Superconducting Rotor for A 1.4 MW Electric Machine in a Thermal Vacuum Chamber

NASA’s high efficiency megawatt motor (HEMM) is a partially superconducting, 1.4 MW electric machine designed for electrified aircraft propulsion. HEMM’s high performance is enabled by a field winding composed of 2nd generation high temperature superconducting (HTS) coils that are designed to operate at temperatures below 62 K. The superconducting rotor is conductively cooled to cryogenic temperatures using a rotating cryocooler embedded inside the machine’s shaft. This paper presents a static test of the full-scale superconducting rotor in a thermal vacuum chamber. The experimental setup is described in detail. Thermal and electromagnetic 3D finite element analyses of the experimental setup are shown along with a comparison of the model results to model results for HEMM. The thermal response during cool down from room temperature is discussed. Electrical measurements are presented for operation at different dc current excitations up to the rated current of the rotor (57.2 A) and temperature limit of the HEMM design (62 K). The results suggest that minor damage to one superconducting coil occurred at 50 A and 61.2 K, causing increased resistance in the system, but that the system could still be stably operated at 57.2 A and 62 K when conductively cooled by a cryocooler.

electrified aircraft propulsion↗

Sunspot: A program to model the behavior of hypervelocity impact damaged multilayer insulation in the Sunspot thermal vacuum chamber of Marshall Space Flight Center

The development of a computer program to predict the degradation of the insulating capabilities of the multilayer insulation (MLI) blanket of Space Station Freedom due to a hypervelocity impact with a space debris particle is described. A finite difference scheme is used for the calculations. The computer program was written in Microsoft BASIC. Also described is a test program that was undertaken to validate the numerical model. Twelve MLI specimens were impacted at hypervelocities with simulated debris particles using a light gas gun at Marshall Space Flight Center. The impact-damaged MLI specimens were then tested for insulating capability in the space environment of the Sunspot thermal vacuum chamber at MSFC. Two undamaged MLI specimens were also tested for comparison with the test results of the damaged specimens. The numerical model was found to adequately predict behavior of the MLI specimens in the Sunspot chamber. A parameter, called diameter ratio, was developed to relate the nominal MLI impact damage to the apparent (for thermal analysis purposes) impact damage based on the hypervelocity impact conditions of a specimen.

Rule, W. K.↗

Thermal Vacuum Chamber Demonstration of a Cryocooled, HTS Rotor for a 1.4 MW Electric Machine for Electrified Aircraft Propulsion

Aircraft with electrified propulsion systems require electric machines that are very lightweight and highly efficient. Advancements to the state of the art are required to meet this demand. This is particularly true for large transport aircraft with more than about 150 passengers, which will require electric machines with power ratings in the 1 to 30+ MW range. At this scale of power, superconducting technology becomes attractive for electrified aircraft propulsion to increase efficiency and reduce mass [1]. A mass reduction relative to non-superconducting machines can result from an increase in the specific power of the machine and indirectly through a significant reduction in the amount of waste heat generated on the aircraft, which reduces the mass of the thermal management system [2]. NASA’s high efficiency megawatt motor (HEMM) is a 1.4 MW partially superconducting machine that is being developed to achieve an efficiency greater than 98% and electromagnetic specific power greater than 16 kW/kg. HEMM contains a copper stator operating at an average temperature around 423 K and a superconducting rotor composed of no-insulation 2nd generation high temperature superconducting (HTS) coils that operates around 60 K. The superconducting coils are conductively cooled by a pulse tube cryocooler embedded inside and rotating with the rotor shaft. This paper presents a full-scale demonstration of the rotor in a thermal vacuum chamber at the designed operating temperature. The test was designed to validate the design of HEMM’s rotor, namely the ability to operate the 2G HTS coils at their rated direct current in a relevant thermal environment while being conductively cooled.

high temperature superconductors↗

Development of a Thermal Vacuum Chamber for Lunar Surface Simulation

Simulating the lunar surface environment is a critical component in advancing the Technology Readiness Level (TRL) of newly developed lunar surface exploration systems and understanding regolith dynamics. Developing systems with the ability to simulate the lunar surface environment presents unique challenges associated with both the hardware requirements of the system and the uniqueness of the lunar environment. Additionally, many thermal vacuum testing systems are large and expensive to maintain and operate, increasing the cost for the end users. Many low TRL prototypes are small-scale and low-cost, making it unfeasible and unnecessary to utilize larger scale testing facilities. A small-scale, modular, and easily reconfigurable chamber with a quick testing turnaround time could allow rapid TRL advancement with minimal costs and time commitments relative to many of the current testing facilities. Here, we introduce a thermal vacuum chamber system that will support experimentation and rapid testing and maturation of small-scale hardware systems and subsystems for lunar surface exploration.

Thermal Vacuum Chamber↗

Automated Positioner For A Specimen In A Vacuum Chamber

Custom-build apparatus positions specimen in vacuum system in three translational and one rotational degree of freedom. Operates under manual control, local microprocessor control, or remote computer control via general-purpose interface bus (GPIB), specific control option being selectable by technician. Used to position and orient specimen for secondary-ion mass spectroscopy (SIMS). Apparatus made from relatively inexpensive parts.

Bailey, Sheila G.↗

Thermal Vacuum Chamber Repressurization with Instrument Purging

At the end of James Webb Space Telescope (JWST) OTIS (Optical Telescope Element-OTE-Integrated Science Instrument Module-ISIM) cryogenic vacuum testing in NASA Johnson Space Centers (JSCs) thermal vacuum (TV) Chamber A, contamination control (CC) engineers are mooting the idea that chamber particulate material stirred up by the repressurization process may be kept from falling into the ISIM interior to some degree by activating instrument purge flows over some initial period before opening the chamber valves. This memo describes development of a series of models designed to describe this process. These are strung together in tandem to estimate overpressure evolution from which net outflow velocity behavior may be obtained. Creeping flow assumptions are then used to determine the maximum particle size that may be kept suspended above the ISIM aperture, keeping smaller particles from settling within the instrument module.

Venting↗

Thermal Vacuum Chamber Repressurization with Instrument Purging

At the end of James Webb Space Telescope (JWST) OTIS (Optical Telescope Element-OTE-Integrated Science Instrument Module-ISIM) cryogenic vacuum testing in NASA Johnson Space Centers (JSCs) thermal vacuum (TV) Chamber A, contamination control (CC) engineers are mooting the idea that chamber particulate material stirred up by the repressurization process may be kept from falling into the ISIM interior to some degree by activating instrument purge flows over some initial period before opening the chamber valves. This memo describes development of a series of models designed to describe this process. These are strung together in tandem to estimate overpressure evolution from which net outflow velocity behavior may be obtained. Creeping flow assumptions are then used to determine the maximum particle size that may be kept suspended above the ISIM aperture, keeping smaller particles from settling within the instrument module.

Repressurization↗

Capabilities, Design, Construction and Commissioning of New Vibration, Acoustic, and Electromagnetic Capabilities Added to the World's Largest Thermal Vacuum Chamber at NASA's Space Power Facility

NASA s human space exploration plans developed under the Exploration System Architecture Studies in 2005 included a Crew Exploration Vehicle launched on an Ares I launch vehicle. The mass of the Crew Exploration Vehicle and trajectory of the Ares I coupled with the need to be able to abort across a large percentage of the trajectory generated unprecedented testing requirements. A future lunar lander added to projected test requirements. In 2006, the basic test plan for Orion was developed. It included several types of environment tests typical of spacecraft development programs. These included thermal-vacuum, electromagnetic interference, mechanical vibration, and acoustic tests. Because of the size of the vehicle and unprecedented acoustics, NASA conducted an extensive assessment of options for testing, and as result, chose to augment the Space Power Facility at NASA Plum Brook Station, of the John H. Glenn Research Center to provide the needed test capabilities. The augmentation included designing and building the World s highest mass capable vibration table, the highest power large acoustic chamber, and adaptation of the existing World s largest thermal vacuum chamber as a reverberant electromagnetic interference test chamber. These augmentations were accomplished from 2007 through early 2011. Acceptance testing began in Spring 2011 and will be completed in the Fall of 2011. This paper provides an overview of the capabilities, design, construction and acceptance of this extraordinary facility.

Motil, Susan M.↗

Low-Dead-Volume Inlet for Vacuum Chamber

Gas introduction from near-ambient pressures to high vacuum traditionally is accomplished either by multi-stage differential pumping that allows for very rapid response, or by a capillary method that allows for a simple, single-stage introduction, but which often has a delayed response. Another means to introduce the gas sample is to use the multi-stage design with only a single stage. This is accomplished by using a very small conductance limit. The problem with this method is that a small conductance limit will amplify issues associated with dead -volume. As a result, a high -vacuum gas inlet was developed with low dead -volume, allowing the use of a very low conductance limit interface. Gas flows through the ConFlat flange at a relatively high flow rate at orders of magnitude greater than through the conductance limit. The small flow goes through a conductance limit that is a double-sided ConFlat.

Naylor, Guy↗