Development of high temperature ceramic rectifiers, thyratrons, and voltage regulator tubes final report, jun. 26, 1963 - oct. 7, 1964
Ceramic voltage regulator tubes, gas diodes, and thyratrons
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Ceramic voltage regulator tubes, gas diodes, and thyratrons
The ever-growing higher penetration of distributed energy resources (DERs) in low-voltage (LV) distribution systems brings both opportunities and challenges to voltage support and regulation. This paper proposes a deep reinforcement learning (DRL)-based scheduling scheme of energy storage systems (ESSs) to mitigate system voltage deviations in unbalanced LV distribution networks. The ESS-based voltage regulation problem is formulated as a multi-stage quadratic stochastic program, with the objective of minimizing the expected total daily voltage regulation cost while satisfying operational constraints. While existing voltage regulation methods are mostly focused on onetime- step control, this paper explores a day-horizon systemwide voltage regulation problem. In other words, the size of action and state spaces are extremely high-dimensional and need to be delicately handled. Furthermore, in order to overcome the difficulty of modeling uncertainties and develop a realtime solution, a learn-to-schedule feedback control framework is proposed by adapting the problem to a model-free DRL setting. The proposed algorithm is tested on a customized 6-bus system and a modified IEEE 34-bus system. Simulation results validate the effectiveness and near-optimality of voltage regulation by ESS in comparison with a deterministic quadratic program solution.
This article proposes data-driven control via a nonlinear autoregressive model with exogenous inputs (NARX) for real-time voltage regulation of a modified feeder using reactive power sources. Traditional voltage control strategies rely on rule-based heuristics or optimization techniques, which often require detailed system models and extensive computational resources. The NARX-based controller learns system dynamics from historical data and predicts optimal reactive power dispatch in real-time for voltage correction. The proposed approach is evaluated on a power system feeder model under varying load and network conditions. Simulation results demonstrate that the NARX-based controller achieves improved voltage regulation, offering higher adaptability to system fluctuations. This study highlights the potential of data-driven control for enhancing the reliability of power distribution networks.
We propose a novel algorithm to solve optimal power flow (OPF) that aims at dispatching controllable distributed energy resources (DERs) for voltage regulation at minimum cost. The proposed algorithm features unprecedented scalability to large distribution networks by utilizing an information structure based on networked autonomous grids (AGs). Specifically, each AG is a subtree of a large distribution network that has a tree topology. The topology and line parameters of each AG are known only to a regional coordinator (RC) that is responsible for communicating with and dispatching the DERs within this AG. The reduced network, where each AG is treated as a node, is managed by a central coordinator (CC), which knows the topology and line parameters of the reduced network only and communicates with all the RCs. We jointly explore this information structure and the structure of the linearized distribution power flow (LinDistFlow) model to derive a hierarchical, distributed implementation of the primal-dual gradient algorithm that solves the OPF. The proposed implementation significantly reduces the computation burden compared to the centrally coordinated implementation of the primal-dual algorithm. Numerical results on a 4,521-node test feeder show that the proposed hierarchical distributed algorithm can achieve an improvement of more than tenfold in the speed of convergence compared to the centrally coordinated primal-dual algorithm.
Effects of neutron irradiation on silicon voltage regulator Zener diodes
We propose a novel algorithm to solve optimal power flow (OPF) that aims at dispatching controllable distributed energy resources (DERs) for voltage regulation at minimum cost. The proposed algorithm features unprecedented scalability to large distribution networks by utilizing an information structure based on networked autonomous grids (AGs). Specifically, each AG is a subtree of a large distribution network that has a tree topology. The topology and line parameters of each AG are known only to a regional coordinator (RC) that is responsible for communicating with and dispatching the DERs within this AG. The reduced network, where each AG is treated as a node, is managed by a central coordinator (CC), which knows the topology and line parameters of the reduced network only and communicates with all the RCs. We jointly explore this information structure and the structure of the linearized distribution power flow (LinDistFlow) model to derive a hierarchical, distributed implementation of the primal-dual gradient algorithm that solves OPF. The proposed implementation significantly reduces the computation burden compared to the centrally coordinated implementation of the primal-dual algorithm. Numerical results on a 4,521-node test feeder show that the proposed hierarchical distributed algorithm can achieve more than 10-fold improvement in the speed of convergence compared to the centrally coordinated primal-dual algorithm.
The growing integration of distributed solar photovoltaic (PV) in distribution systems could result in adverse effects during grid operation. This paper develops a soft actor critic-based deep reinforcement learning (SAC-DRL) solution to simultaneously control PV inverters and battery energy storage systems for voltage regulation and peak load demand shaving. The novel two-stage framework, featured with two different control agents, is applied for daytime and nighttime operation to enhance the control performance. Comparison results with other control methods on a real feeder in Western Colorado demonstrate that the proposed method can provide advanced voltage regulation with modest active power curtailment for peak demand reduction.
The growing integration of distributed solar photovoltaic (PV) in distribution systems could result in adverse effects during grid operation. This paper develops a two-agent soft actor critic-based deep reinforcement learning (SAC-DRL) solution to simultaneously control PV inverters and battery energy storage systems for voltage regulation and peak demand reduction. The novel two-stage framework, featured with two different control agents, is applied for daytime and nighttime operations to enhance control performance. Comparison results with other control methods on a real feeder in Western Colorado demonstrate that the proposed method can provide advanced voltage regulation with modest active power curtailment and reduce peak load demand from feeder's head.
Grid edge intelligence has been of interest in both industrial and academic research spaces as the penetration level of distributed energy resources increases. This paper discusses the application of a framework that can perform techno-economic analyses for integrating intelligent autonomous controls into the distribution grid. The framework has been used to provide cost-benefit studies for two smart voltage regulator control algorithms that come as black-box applications. These applications are evaluated within the framework using quasistatic time-series simulations. Results are presented in terms of performance metrics and costs incurred for these two smart voltage regulator control techniques.
Increasing solar energy penetrations may create challenges for distribution system operations because production variability can lead to large voltage deviations or protection system miscoordination. Instituting advanced management systems on distribution systems is one promising method for combating these challenges by intelligently controlling distribution assets to regulate voltage and ensure protection safety margins. While it is generally not the case today, greater deployment of power system sensors and interoperable distributed energy resources (DER)e.g., photovoltaic (PV) inverters, energy storage systems (ESS), electric vehicles (EVs)will enable situational awareness, control, and optimization of distribution systems. In this work, a control system was created which measures power system parameters to estimate the status of a feeder, forecasts the distribution state over a short-term horizon, and issues optimal set point commands to distribution-connected equipment to regulate voltage and protect the system. This two-year project integrated multiple research innovations into a management system designed to safely allow PV penetrations of 50% or greater. The integrated software was demonstrated through extensive real-time (RT) and power hardware-in-the-loop studies and a field demonstration on a live power system with a 684 kVA PV system.
Duke Energy, Alstom Grid, and the National Renewable Energy Laboratory teamed up to better understand the impacts of solar photovoltaics (PV) on distribution system operations. The core goal of the project is to compare the operational - specifically, voltage regulation - impacts of three classes of PV inverter operations: 1.) Active power only (Baseline); 2.) Local inverter control (e.g., PF...not equal...1, Q(V), etc.); and 3.) Integrated volt-VAR control (centralized through the distribution management system). These comparisons were made using multiple approaches, each of which represents an important research-and-development effort on its own: a) Quasi-steady-state time-series modeling for approximately 1 year of operations using the Alstom eTerra (DOTS) system as a simulation engine, augmented by Python scripting for scenario and time-series control and using external models for an advanced inverter; b) Power-hardware-in-the-loop (PHIL) testing of a 500-kVA-class advanced inverter and traditional voltage regulating equipment. This PHIL testing used cosimulation to link full-scale feeder simulation using DOTS in real time to hardware testing; c) Advanced visualization to provide improved insights into time-series results and other PV operational impacts; and d) Cost-benefit analysis to compare the financial and business-model impacts of each integration approach.
Embodiments of the disclosure provide for hierarchically distributed voltage regulation and power flow optimization in a power distribution network. According to one embodiment, a regional coordinator system may determine power flow for an autonomous grid (AG) representing a portion of the distribution network based on a set of voltage parameters from nodes in the AG. The set of voltage parameters my include a current voltage magnitude. The regional coordinator system may provide, to a central controller system of the distribution network, one or more power flow parameters based on the determined power flow for the AG.
The emerging of microgrids in distribution systems has significantly enhanced the resilience of power grids. However, the operators of a distribution system and microgrids therein can be different and have accessibility to different devices. To model the operation of such a grid, this work proposes a bilevel formulation and probes into the voltage regulation operation, considering the interaction between different systems. The proposed bilevel formulation considers the cooperation of active energy resources (AER), transformer tap-changers, and capacitor banks that are controlled by different operators. To facilitate the solution time of the target bilevel optimization, the lower-level problems with different objectives are modeled using deep neural networks (DNNs) which are then converted into a set of constraints. Hence, the bilevel problem can be reformed to a single-level problem. Lastly, the proposed solution procedures are validated using a customized joint system constructed by the IEEE 123-bus system and a real distribution system in Iowa. According to the numerical validation results, the solution time of the proposed nonlinear activation function based DNN model is 69 times faster than other methods in solving voltage regulation with a bilevel structure.
Dissipative voltage regulator system for minimizing heat dissipation
New voltage regulator isolates signals from power-switching converter without use of complex circuitry or optical couplers. Only addition is extra secondary winding on existing interstage transformer. Error signals shortcircuit new winding and inhibit converter action. Resistor in series with primary winding limits short-circuit current to prevent damage to circuit components. Extra transformer winding eliminates need for isolation components.
We introduce a new control paradigm termed Phasor-Based Control (PBC) to coordinate Distributed Energy Resources (DER) for improved voltage regulation and other objectives. PBC is a multi-layer control framework where the state of the distribution grid is represented by voltage phasors, and Phasor Measurement Units (PMUs) measure the state at critical points in the distribution grid. In the PBC paradigm, a supervisory controller (S-PBC) sets phasor targets which local controllers track. In this paper, we propose a Proportional Integral (PI) implementation for the local control layer (LPBC), to regulate real and reactive power output of distributed inverters to track a voltage phasor target computed by the supervisory layer. We tune the PI controller gains offline with a genetic algorithm that yields better performance than the Ziegler-Nichols method. We benchmark the proposed L-PBC controller against droop volt-var control (DVVC) and observe improved voltage regulation in simulation on the IEEE 13 node unbalanced test feeder (IEEE 13NF). Furthermore, by means of numerical simulation we observe the response of the L-PBC controllers to small and large grid disturbances. Simulations on larger feeders, IEEE 123-node and 647-node, demonstrate challenges with tuning controllers in setups with different amounts of power-voltage coupling.
Shunt voltage regulator circuit for nickel- cadmium cells with auxiliary electrodes
With the growing availability of Electric Vehicles, there is a significant opportunity to use battery 'smart-charging' for voltage regulation. This work designs and experimentally evaluates a system for price-incentivised electric vehicle charging. The system is designed to eliminate negative impacts to the user while minimising the cost of charging and achieving a more favourable voltage behaviour throughout the local grid over time. The practical issues associated with a real-life deployment are identified and resolved. The efficacy of the system is evaluated in the challenging scenario in which EVs are deployed in six closely distributed homes, serviced by the same low voltage residential distribution feeder.