Single-Crystal Linear Polymers Through Visible Light-Triggered Topochemical Quantitative Polymerization
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Not Available
This international conference will provide a technical forum on advances in the scientific understanding of the effects of aerosols on urban, regional, continental, and global-scale haze and the radiative balance. The conference will take a multipronged approach and address scientific topics (e.g., related to measurements, modeling, etc.) as well as regulatory and policy issues. There will be sessions on black and brown carbon, as recent research has shown the importance of these particles for radiative forcing. In addition, there will be sessions related to the synergistic and increasing concerns of the effects of atmospheric nitrogen and carbonaceous material on haze, climate change, and nitrogen deposition on ecosystems. Conference learning will be enhanced with a half day excursion and hikes in Grand Teton National Park and a Night Sky Program.
Degree of coherence of optical beam traversing atmospheric medium including simulated fog for design of optical heterodyne receiver
Purpose: In radiation therapy of pancreatic cancer, tumor alignment prior to each treatment fraction is improved when intratumoral gold fiducial markers (from here onwards: markers), which are visible on computed tomography (CT) and cone beam CT, are used. Visibility of these markers on magnetic resonance imaging (MRI) might improve image registration between CT and magnetic resonance (MR) images for tumor delineation purposes. However, concomitant image artifacts induced by markers are undesirable. The extent of visibility and artifact size depend on MRI-sequence parameters. The authors’ goal was to determine for various markers their potential to be visible and to generate artifacts, using measures that are independent of the MRI-sequence parameters. Methods: The authors selected ten different markers suitable for endoscopic placement in the pancreas and placed them into a phantom. The markers varied in diameter (0.28–0.6 mm), shape, and iron content (0%–0.5%). For each marker, the authors calculated T{sub 2}{sup ∗}-maps and ΔB{sub 0}-maps using MRI measurements. A decrease in relaxation time T{sub 2}{sup ∗} can cause signal voids, associated with visibility, while a change in the magnetic field B{sub 0} can cause signal shifts, which are associated with artifacts. These shifts inhibit accurate tumor delineation. As a measure for potential visibility, the authors used the volume of low T{sub 2}{sup ∗}, i.e., the volume for which T{sub 2}{sup ∗} differed from the background by >15 ms. As a measure for potential artifacts, the authors used the volume for which |ΔB{sub 0}| > 9.4 × 10{sup −8} T (4 Hz). To test whether there is a correlation between visibility and artifact size, the authors calculated the Spearman’s correlation coefficient (R{sub s}) between the volume of low T{sub 2}{sup ∗} and the volume of high |ΔB{sub 0}|. The authors compared the maps with images obtained using a clinical MR-sequence. Finally, for the best visible marker as well as the marker that showed the smallest artifact, the authors compared the phantom data with in vivo MR-images in four pancreatic cancer patients. Results: The authors found a strong correlation (R{sub s} = 1.00, p < 0.01) between the volume of low T{sub 2}{sup ∗} and the volume with high |ΔB{sub 0}|. Visibility in clinical MR-images increased with lower T{sub 2}{sup ∗}. Signal shift artifacts became worse for markers with high |ΔB{sub 0}|. The marker that was best visible in the phantom, a folded marker with 0.5% iron content, was also visible in vivo, but showed artifacts on diffusion weighted images. The marker with the smallest artifact in the phantom, a small, stretched, ironless marker, was indiscernible on in vivo MR-images. Conclusions: Changes in T{sub 2}{sup ∗} and ΔB{sub 0} are sequence-independent measures for potential visibility and artifact size, respectively. Improved visibility of markers correlates strongly to signal shift artifacts; therefore, marker choice will depend on the clinical purpose. When visibility of the markers is most important, markers that contain iron are optimal, preferably in a folded configuration. For artifact sensitive imaging, small ironless markers are best, preferably in a stretched configuration.
The development of a new increased range higher visibility was investigated. The visibility sensor that is currently is the Transmissometer. Current transmissometer technology provides only a factor of 10 dynamic range with a single base line. The FAA is preparing to install automated weather observing systems (AWOS) at many locations. These systems require visibilities up to approximately 5 miles. To use a transmissometer for this type of measurement, the base line must be about 1,000 feet; where alignment becomes very difficult to maintain. New technologies were developd for measuring visibility. Improved transmissometers, forward-scatter meters and back-scatter meters have become available. A current practical issue for visibility sensors is how to specify one that is good enough to meet the needs of aviation. The first question is what performance is required; how accurately must the sensor measure? Visibility sensors do not actually measure the visibility directly. The purpose of measuring the visibility is to predict what the pilot will see a considerable distance away from the sensor location. The atmosphere introduces considerable variation in the measurement and the basic sensor accuracy needed is difficult to define. The second question for high visibilities is what to use as the standard reference sensor. The third question pertains to the competitive procurement of visibility sensors, which is mandated at present. Two acceptance test procedures to be used to insure satisfactory sensor performance is examined.
Purpose: To measure and investigate the improvement of microcalcification (MC) visibility in cone beam breast CT with a high pitch (75 μm), thick (500 μm) scintillator CMOS/CsI flat panel detector (Dexela 2923, Perkin Elmer).Methods: Aluminum wires and calcium carbonate grains of various sizes were embedded in a paraffin cylinder to simulate imaging of calcifications in a breast. Phantoms were imaged with a benchtop experimental cone beam CT system at various exposure levels. In addition to the Dexela detector, a high pitch (50 μm), thin (150 μm) scintillator CMOS/CsI flat panel detector (C7921CA-09, Hamamatsu Corporation, Hamamatsu City, Japan) and a widely used low pitch (194 μm), thick (600 μm) scintillator aSi/CsI flat panel detector (PaxScan 4030CB, Varian Medical Systems) were also used in scanning for comparison. The images were independently reviewed by six readers (imaging physicists). The MC visibility was quantified as the fraction of visible MCs and measured as a function of the estimated mean glandular dose (MGD) level for various MC sizes and detectors. The modulation transfer functions (MTFs) and detective quantum efficiencies (DQEs) were also measured and compared for the three detectors used.Results: The authors have demonstrated that the use of a high pitch (75 μm) CMOS detector coupled with a thick (500 μm) CsI scintillator helped make the smaller 150–160, 160–180, and 180–200 μm MC groups more visible at MGDs up to 10.8, 9, and 10.8 mGy, respectively. It also made the larger 200–212 and 212–224 μm MC groups more visible at MGDs up to 7.2 mGy. No performance improvement was observed for 224–250 μm or larger size groups. With the higher spatial resolution of the Dexela detector based system, the apparent dimensions and shapes of MCs were more accurately rendered. The results show that with the aforementioned detector, a 73% visibility could be achieved in imaging 160–180 μm MCs as compared to 28% visibility achieved by the low pitch (194 μm) aSi/CsI flat panel detector. The measurements confirm that the Hamamatsu detector has the highest MTF, followed by the Dexel detector, and then the Varian detector. However, the Dexela detector, with its thick (500 μm) CsI scintillator and low noise level, has the highest DQE at all frequencies, followed by the Varian detector, and then the Hamamatsu detector. The findings on the MC visibility correlated well with the differences in MTFs, noise power spectra, and DQEs measured for these three detectors.Conclusions: The authors have demonstrated that the use of the CMOS type Dexela detector with its high pitch (75 μm) and thick (500 μm) CsI scintillator could help improve the MC visibility. However, the improvement depended on the exposure level and the MC size. For imaging larger MCs or scanning at high exposure levels, there was little advantage in using the Dexela detector as compared to the aSi type Varian detector. These findings correlate well with the higher measured DQEs of the Dexela detector, especially at higher frequencies.
Description of an in-flight visibility test conducted during the Apollo 14 mission for the purpose of validating and extending the mathematical visibility models used previously in the course of the Apollo program to examine the constraints on descent operations imposed by lunar visibility limitations. Following a background review of the effects on mission planning of the visibility limitations due to downsun lunar surface detail 'washout' and a discussion of the visibility prediction techniques previously used for studying lunar visibility problems, the visibility test rationale and procedures are defined and the test results presented. The results appear to confirm the validity of the visibility prediction techniques employed in lunar visibility problem studies. These results provide also a basis for improving the accuracy of the prediction techniques by appropriate modifications.
A dual-phase material (DP-160) comprising hydrated titanate (H{sub 2}Ti{sub 3}O{sub 7}{center_dot}xH{sub 2}O) and anatase (TiO{sub 2}) was synthesized in a low-temperature one-pot process in the presence of triethylamine (TEA) as the N-source. The unique structure exhibits strong visible light absorption. The chromophore is linked to Ti-N bonds derived from both surface sensitization and sub-surface (bulk) doping. From transmission electron microscope (TEM) and textural studies by N{sub 2} physisorption, the composite exists as mesoporous particles with a grain size of {approx}20 nm and mean pore diameter of 3.5 nm, responsible for the high surface area ({approx}180 m{sup 2}/g). DP-160 demonstrated photocatalytic activity in the degradation of phenol under visible light ({lambda}>420 nm). The activity of the composite was further enhanced by a small addition (0.001 M) of H{sub 2}O{sub 2}, which also gave rise to some visible light activity in the control samples. This effect is believed to be associated with the surface peroxo-titanate complex. GC-MS analyses showed that the intermediate products of phenol degradation induced by visible light irradiation of DP-160 did not differ from those obtained by UV (band-gap) irradiation of TiO{sub 2}. The overall performance of the composite is attributed to efficient excitation via inter-band states (due to N-doping), surface sensitization, improved adsorptive properties of aromatic compounds due to the N-carbonaceous overlayer, and the presence of heterojunctions that are known to promote directional charge transfer in other mixed-phase titanias like Degussa P25. - graphical abstract: Nitrogen-sensitized dual phase titanate/titania photocatalyst showing extended visible light absorption and efficient photocatalytic degradation of phenol. Highlights: Black-Right-Pointing-Pointer Low temperature one-pot synthesis of visible light active dual phase photocatalyst. Black-Right-Pointing-Pointer The dual phase consists of nanoscale titanate and anatase titania phases. Black-Right-Pointing-Pointer The photocatalyst displays high activity in degrading phenol under visible light. Black-Right-Pointing-Pointer Mechanisms for the sensitization to visible light are considered.
The deterioration of visibility due to air pollutants and relative humidity has been a serious environmental problem in eastern Asia. In most previous studies, chemical compositions of atmospheric particles were provided using filter-based offline analyses, which were unable to provide long-term and in-situ measurements that resolve sufficient temporal variations of air pollution and meteorology, hindering the resolution of the relationship between air quality and visibility. Here, we present a year-long continuously measured data from a comprehensive suite of online instruments to investigate diurnal and seasonal impacts of the aerosol chemical compositions in PM2.5 on visibility seasonally and diurnally. The measured dry aerosol extinction at λ = 550 nm reached a closure with that predicted by aerosol compositions within 12%. However, the hygroscopic growth of particles under ambient RH could enhance the aerosol extinction by a factor of 2 – 6, matching the perceptive visibility of the public. Particulate ammonium nitrate was most sensitive to reducing visibility, while ammonium sulfate contributed the most to the light extinction. In spring and winter, the monsoon and stagnant air masses reduced the visibility and increased PM2.5 (> 35 μg m-3).The moisture was found to substantially enhance the light extinction under RH = 60 – 90%,reducing visibility by approximately 15 km, largely attributed to hygroscopic inorganic salts.This study serves as a metric to highlight the need to consider the influence of RH, and aqueous reactions in producing secondary inorganic aerosols on atmospheric visibility, underpinning the more accurate mitigation strategies of air pollution.
Graphical abstract: High-performance and recyclable visible-light driven g-C{sub 3}N{sub 4}/NaTaO{sub 3} hybrid nanocomposite photocatalysts have been prepared by a facile ultrasonic dispersion method. The hybrid nanocomposite photocatalyst can be promising photocatalytic material for practical application in water splitting and environmental remediation. - Highlights: • Novel g-C{sub 3}N{sub 4}/NaTaO{sub 3} nanocomposites as a high performance and recyclable photocatalysts. • These catalysts exhibited significantly enhanced photocatalytic activity under UV–visible light irradiation. • More attractively, dramatic activity is generated under visible light irradiation due to the g-C{sub 3}N{sub 4} loaded. • Interestingly, the as-prepared hybrid nanocomposites possess high reusability. - Abstract: Novel g-C{sub 3}N{sub 4}/NaTaO{sub 3} hybrid nanocomposites have been prepared by a facile ultrasonic dispersion method. Our results clearly show the formation of interface between NaTaO{sub 3} and g-C{sub 3}N{sub 4} and further loading of g-C{sub 3}N{sub 4} did not affect the crystal structure and morphology of NaTaO{sub 3}. The g-C{sub 3}N{sub 4}/NaTaO{sub 3} nanocomposites exhibited enhanced photocatalytic performance for the degradation of Rhodamine B under UV–visible and visible light irradiation compared to pure NaTaO{sub 3} and Degussa P25. Interestingly, the visible light photocatalytic activity is generated due to the loading of g-C{sub 3}N{sub 4}. A mechanism is proposed to discuss the enhanced photocatalytic activity based on trapping experiments of photoinduced radicals and holes. Under visible light irradiation, electron excited from the valance band (VB) to conduction band (CB) of g-C{sub 3}N{sub 4} could directly inject into the CB of NaTaO{sub 3}, making g-C{sub 3}N{sub 4}/NaTaO{sub 3} visible light driven photocatalyst. Since the as-prepared hybrid nanocomposites possess high reusability therefore it can be promising photocatalyst for environmental applications.
Highlights: • W, N, S codoped TiO{sub 2} nanoparticles were synthesized by precipitation-impregnation method. • New linkages N–Ti–O, Ti–O–S and Ti–O–W were formed. • The activity of 0.011W, 0.030(N,S)-TiO{sub 2} is 10 times higher than that of TiO{sub 2}. • The doping enhanced visible light absorbance and accelerated the charge carrier separation. - Abstract: In this work, the preparation and physiochemical characterization of tungsten, nitrogen and sulfur codoping TiO{sub 2} photocatalysts (W, N, S-TiO{sub 2}) was undertaken. W, N, S-TiO{sub 2} nanoparticles were synthesized via the precipitation-impregnation method. To investigate the structural, optical, and electronic properties, the as-prepared W, N, S-TiO{sub 2} photocatalysts were characterized by X-ray diffraction (XRD), high-resolution transmission electron microscopy (HR-TEM), X-ray photoelectron spectroscopy (XPS), and ultraviolet-visible diffuse reflection spectrum (DRS). W, N, S-TiO{sub 2} samples showed photo-absorption in the visible light region and higher visible light photocatalytic activity than TiO{sub 2}. 0.011W, 0.030(N, S)-TiO{sub 2} exhibited the highest visible light photocatalytic activity, and the photocatalyic degradation activity of 0.011W,0.030(N,S)-TiO{sub 2} is nearly 10 times higher than that of TiO{sub 2}. Compared with the undoped TiO{sub 2}, the improved photocatalytic activity of W, N, S-TiO{sub 2} samples under visible light irradiation is attributed to the increase of the visible light absorption and the reduction in photogenerated electron-hole recombination.
Highlights: • An efficient visible-light photocatalyst was prepared by modifying AgBr particles. • A small amount of activated carbon was used to modify AgBr particles. • The modified AgBr exhibited improved visible-light photocatalytic performances. - Abstract: An efficient visible-light photocatalyst was successfully prepared by modifying AgBr particles with a small amount of activated carbon (AC) via a simple chemical precipitation approach. The AC/AgBr composite was characterized by X-ray diffraction, X-ray photoelectron spectroscopy, scanning electron microscopy, UV–vis diffuse reflection spectroscopy, photoluminescence spectroscopy, electrochemical impedance spectroscopy. The photocatalytic performances of the AC/AgBr composite were investigated by evaluating photodegradation of methyl orange (MO) and phenol under visible light irradiation, and the effects of the AC content in the composite, concentrations of AC/AgBr composite and MO, carrier scavengers on MO photodegradation rate were systematically investigated. The results indicated that the modification of AC can hardly change the crystalline and crystal size of AgBr particles, while significantly improve their specific surface areas, visible-light absorption and separation efficiency of photogenerated electron–hole pairs. Compared with pure AgBr, the AC/AgBr composite exhibited drastically enhanced visible-light photocatalytic activity and stability. The photogenerated electrons and holes, hydroxyl radicals are responsible to the photodegradation of organic pollutants, and the photogenerated holes are the main active species. On the basis of the results and the properties of AC and AgBr, the visible-light photocatalytic mechanism of the AC/AgBr composite was discussed.
Purpose: Intrafractional lung tumor motion during radiotherapy can be compensated for by tracking the tumor position using x-ray imaging and adapting the treatment in real-time. However, locating the tumor with an automated template-matching algorithm is often challenging if the tumor is obscured by ribs. This study investigates the feasibility of creating dual-energy (DE) images of the chest with increased tumor visibility on an Elekta XVI system. Methods: An anthropomorphic chest phantom was imaged at two different energies. Low-energy images were obtained at 80 kVp (0.8 mAs); high-energy images at 129 kVp (0.6 mAs, additional 1.26 mm tin filter). A Geant4 Monte-Carlo framework was developed allowing simulation of the x-ray tube, flat-panel detector and phantom in order to optimize the beam energies, filtration and the weighting factor used to subtract the individual images into a synthetic DE image. The weighting factor was selected to minimize the visibility of bones while maintaining a sufficient tumor visibility. We scored the bone visibility as the contrast of tumor (with bone) to tumor (without bone), and similarly of lung tissue (with bone) to lung tissue (without bone). Tumor visibility was quantified as the contrast between tumor and lung tissue (both without bone). Results: In the experimentally obtained DE image the bone visibility was reduced by 79.2% in tumor and by 96.8% in lung tissue while the overall tumor visibility only decreased by 69.5%. The Monte-Carlo simulation yielded similar results reducing the scores by 90.0%, 85.3% and only 71.9%, respectively. Conclusion: This work demonstrates the feasibility of DE imaging to enhance lung tumor detectability. In the future, we hope to further refine the Monte-Carlo simulation to more accurately predict the weighting factors which would aid real-time implementation. Furthermore, we plan to use the Monte-Carlo framework to simulate DE images of actual lung tumors. The authors would like to thank Paul-Scherrer-Institut and Centre Suisse d'Electronique et Microtechnique for lending us the anthropomorphic phantom. We acknowledge support from Elekta AB under a research agreement. Research at The Institute of Cancer Research is also supported by Cancer Research UK under Programme C46/A10588.
Atomic, molecular and optical (AMO) visible light systems are the heart of precision applications including quantum, atomic clocks and precision metrology. As these systems scale in terms of number of lasers, wavelengths, and optical components, their reliability, space occupied, and power consumption will push the limits of using traditional laboratory-scale lasers and optics. Visible light photonic integration is critical to advancing AMO based sciences and applications, yet key performance aspects remain to be addressed, most notably waveguide losses and laser phase noise and stability. Additionally, a visible light integrated solution needs to be wafer-scale CMOS compatible and capable of supporting a wide array of photonic components. While the regime of ultra-low loss has been achieved at telecommunication wavelengths, progress at visible wavelengths has been limited. Here, we report the lowest waveguide losses and highest resonator Qs to date in the visible range, to the best of our knowledge. We report waveguide losses at wavelengths associated with strontium transitions in the 461 nm to 802 nm wavelength range, of 0.01 dB/cm to 0.09 dB/cm and associated intrinsic resonator Q of 60 Million to 9.5 Million, a decrease in loss by factors of 6x to 2x and increase in Q by factors of 10x to 1.5x over this visible wavelength range. Additionally, we measure an absorption limited loss and Q of 0.17 dB/m and 340 million at 674 nm. This level of performance is achieved in a wafer-scale foundry compatible Si 3 N 4 platform with a 20 nm thick core and TEOS-PECVD deposited upper cladding oxide, and enables waveguides for different wavelengths to be fabricated on the same wafer with mask-only changes per wavelength. These results represent a significant step forward in waveguide platforms that operate in the visible, opening up a wide range of integrated applications that utilize atoms, ions and molecules including sensing, navigation, metrology and clocks.
Abstract Using spectroscopic observations from the Sloan Digital Sky Survey Mapping Nearby Galaxies at Apache Point Observatory Data Release 15, we study the relationships between the ratio of total to visible mass and various parameters characterizing the evolution and environment of the galaxies in this survey. Measuring the rotation curve with the relative velocities of the H α emission line across a galaxy’s surface, we estimate each galaxy’s total mass. We develop a statistical model to describe the observed distribution in the ratio of total to visible mass, from which we extract the most probable value of this mass ratio for a given sample of galaxies. We present the relationships between the ratio of total to visible mass and several characteristics describing galactic evolution, such as luminosity, gas-phase metallicity, distance to the nearest neighbor, and position on the color–magnitude diagram. We find that faint galaxies with low metallicities, typically in the blue cloud, have the highest ratios of total to visible mass. This mass ratio is significantly reduced when we include the H i mass in the total visible mass, implying that feedback mechanisms are not as strong in low-mass galaxies as previously thought. Those galaxies that exhibit the second-highest ratios of total to visible mass are the brightest with high metallicities, typically members of the red sequence or green valley. Active galactic nucleus activity is likely both the quenching mechanism and the feedback that drives the mass ratio higher in these massive galaxies. Finally, we introduce a parameterization that predicts a galaxy’s ratio of total to visible mass based only on its photometry and luminosity.
The lidar process was shown to have the necessary potential to fulfill the need for a remote measurement of visibility. Visibility can be inferred from a lidar return optical extinction. The wavelength 1.54 micron was chosen, being near the visible wavelength region and having a high eye safety threshol, 200,000 times higher than 1.06 micron; 1.54 is the erbium laser wavelength. This research utilized 105 measured height profiles of natural droplet size distributions data, taken in clouds, fog, and haze. These profiles were examined to determine the completeness of the droplet counting data. It was found that the particle spectrometer data were incomplete in the very light ford and haze so this portion of the data was eliminated. Utilizing the Mie theory, these droplet size distribution profiles were converted to backscatter at 1.54 micron and extinction in the visible region, 0.55 micron. Using Koschmeider's relationship, the extinction profiles were converted to visibility. The visibility and backscatter profiles were compared to develop a relationship between visibility and backscatter at 1.54 micron.