Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VIDICON”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Vidicon spectral imaging - Color enhancement and digital maps

A silicon imaging photometer system (SIPS) was used to obtain visible and near-infrared spectral imaging data in four narrow bandpasses (0.38, 0.56, 0.85, and 1.05 microns) for a 400-by-400-km lunar region which includes the Serenitatis-Tranquillitatis border. Three ratio frames were used to make color composites of radio images, and spectral maps based on interactive 'cluster' analysis were produced from four video channels. A low albedo titanium-poor unit occurs near the southern edge of the Serenitatis and south of the basin; this unit appears to postdate the high-titanium dark Tranquillitatis and 'blue-ring' material and may be associated with an Al/Si anomaly noticed in Apollo orbital X-ray data.

Johnson, T. V.↗

LANDSAT 3 return beam vidicon response artifacts: A report on RBV photographic product characteristics and quality coding system

Analysis of large volumes of LANDSAT 3 RBV digital data that were converted to photographic form led to the firm identification of several visible artifacts (objects or structures not normally present, but producted by an external agency or action) in the imagery. These artifacts were identified, categorized, and traced directly to specific sensor response characteristics. None of these artifacts is easily removed and all cases remain under active study of possible future enhancement. The seven generic categories of sensor response artifacts identified to date include: (1) shading and stairsteps; (2) corners out of focus; (3) missing reseaus; (4) reseau distortion and data distortion; (5) black vertical line; (6) grain effect; and (7) faceplate contamination. An additional category under study, but not yet determined to be caused by sensor response, is a geometric anomaly. Examples of affected imagery are presented to assist in distinguishing between image content and innate defects caused by the sensor system.

Clark, B. P.↗

Neutron radiographic viewing system

The design, development and application of a neutron radiographic viewing system for use in nondestructive testing applications is considered. The system consists of a SEC vidicon camera, neutron image intensifier system, disc recorder, and TV readout. Neutron bombardment of the subject is recorded by an image converter and passed through an optical system into the SEC vidicon. The vidicon output may be stored, or processed for visual readout.

Source record↗

Outer planets mission television subsystem optics study

An optics study was performed to establish a candidate optical system design for the proposed NASA Mariner Jupiter/Saturn 77 mission. The study was performed over the 6-month period from January through June 1972. The candidate optical system contains both a wide angle (A) and a narrow angle (B) lens. An additional feature is a transfer mirror mechanism that allows image transfer from the B lens to the vidicon initially used for the A lens. This feature adds an operational redundancy to the optical system in allowing for narrow angle viewing if the narrow angle vidicon were to fail. In this failure mode, photography in the wide angle mode would be discontinued. The structure of the candidate system consists mainly of aluminum with substructures of Invar for athermalization. The total optical system weighs (excluding vidicons) approximately 30 pounds and has overall dimensions of 26.6 by 19.5 by 12.3 inches.

Source record↗

Development and evaluation of infrared sensitive image sensors for space astronomy

The experimental development and evaluation of infrared vidicons for use in solving high precision high flux broadband astronomical problems are discussed. Data cover the EOS, silicon, and doped germanium vidicons. Results are graphed and problems encountered using the vidicons in electrical cameras are reported.

Morton, D. C.↗

Voyager spacecraft images of Jupiter and Saturn

The Voyager imaging system is described, noting that it is made up of a narrow-angle and a wide-angle TV camera, each in turn consisting of optics, a filter wheel and shutter assembly, a vidicon tube, and an electronics subsystem. The narrow-angle camera has a focal length of 1500 mm; its field of view is 0.42 deg and its focal ratio is f/8.5. For the wide-angle camera, the focal length is 200 mm, the field of view 3.2 deg, and the focal ratio of f/3.5. Images are exposed by each camera through one of eight filters in the filter wheel on the photoconductive surface of a magnetically focused and deflected vidicon having a diameter of 25 mm. The vidicon storage surface (target) is a selenium-sulfur film having an active area of 11.14 x 11.14 mm; it holds a frame consisting of 800 lines with 800 picture elements per line. Pictures of Jupiter, Saturn, and their moons are presented, with short descriptions given of the area being viewed.

Birnbaum, M. M.↗

Quantitative measurements of Jupiter, Saturn, their rings and satellites made from Voyager imaging data

The Voyager spacecraft cameras use selenium-sulfur slow scan vidicons to convert focused optical images into sensible electrical signals. The vidicon-generated data thus obtained are the basis of measurements of much greater precision than was previously possible, in virtue of their superior linearity, geometric fidelity, and the use of in-flight calibration. Attention is given to positional, radiometric, and dynamical measurements conducted on the basis of vidicon data for the Saturn rings, the Saturn satellites, and the Jupiter atmosphere.

Collins, S. A.↗

Replacing a technology - The Large Space Telescope and CCDs

The technological improvements, design choices and mission goals which led to the inclusion of CCD detectors in the wide field camera of the Large Space Telescope (LST) to be launched by the STS are recounted. Consideration of CCD detectors began before CCDs had seen wide astronomical applications. During planning for the ST, in the 1960s, photographic methods and a vidicon were considered, and seemed feasible provided that periodic manual maintenance could be performed. The invention of CCDs was first reported in 1970 and by 1973 the CCDs were receiving significant attention as potential detectors instead of a vidicon, which retained its own technological challenges. The CCD format gained new emphasis when success was achieved in developments for planetary-imaging spacecraft. The rapidity of progress in CCD capabilities, coupled with the continued shortcomings of the vidicon, resulted in a finalized choice for a CCD device by 1977. The decision was also prompted by continuing commercial and military interest in CCDs, which was spurring the development of the technology and improving the sensitivities and reliability while lowering the costs.

Smith, R. W.↗

Digital cartography of Io

A high resolution controlled mosaic of the hemisphere of Io centered on longitude 310 degrees is produced. Digital cartographic techniques were employed. Approximately 80 Voyager 1 clear and blue filter frames were utilized. This mosaic was merged with low-resolution color images. This dataset is compared to the geologic map of this region. Passage of the Voyager spacecraft through the Io plasma torus during acquisition of the highest resolution images exposed the vidicon detectors to ionized radiation, resulting in dark-current buildup on the vidicon. Because the vidicon is scanned from top to bottom, more charge accumulated toward the bottom of the frames, and the additive error increases from top to bottom as a ramp function. This ramp function was removed by using a model. Photometric normalizations were applied using the Minnaert function. An attempt to use Hapke's photometric function revealed that this function does not adequately describe Io's limb darkening at emission angles greater than 80 degrees. In contrast, the Minnaert function accurately describes the limb darkening up to emission angles of about 89 degrees. The improved set of discrete camera angles derived from this effort will be used in conjunction with the space telemetry pointing history file (the IPPS file), corrected on 4 or 12 second intervals to derive a revised time history for the pointing of the Infrared Interferometric Spectrometer (IRIS). For IRIS observations acquired between camera shutterings, the IPPS file can be corrected by linear interpolation, provided that the spacecraft motions were continuous. Image areas corresponding to the fields of view of IRIS spectra acquired between camera shutterings will be extracted from the mosaic to place the IRIS observations and hotspot models into geologic context.

Mcewen, Alfred S.↗

Imaging experiment - The Viking Mars Orbiter.

The general objectives of the imaging experiment on the Viking Orbiter are to aid the selection of Viking Lander sites, to map and monitor the chosen sites during lander operations, to aid in the selection of future landing sites, and to extend our knowledge of the planet. The imaging system consists of two identical vidicon cameras each attached to a 1026-mm T/8 telescope giving approximately 1-deg square field of view. From an altitude of 1500 km, the picture elements will be approximately 24 m apart. The vidicon is coupled with an image intensifier which provides increased sensitivity and permits electronic shuttering and image motion compensation. The camera differs from those previously flown to Mars by providing contiguous coverage at high resolution on a single orbital pass, by having sufficient sensitivity to use narrow band color filters at maximum resolution, and by having response in the ultraviolet.

Carr, M. H.↗

Experimental masking of RBV images to reduce stationary residual inaccuracies in radiometric correction

Return beam vidicon tube calibration data are used to correct spatially non-uniform radiance response in individual vidicons, during post-acquisition signal processing. However, examination of different ERTS-1 RBV-1, -2, and -3 image scenes showed stationary, repetitive residual inaccuracies in shading correction, large enough to affect qualitative and quantitative image analyses. Photographic masks designed to reduce residual shading were prepared from RBV-1, -2, and -3 images of a relatively cloud-free ocean scene of uniform reflectance. When applied to other RBV scenes, the masks enabled more closely corrected RBV images to be printed. Illustrations are given of RBV-1 image before and after correction, compared with an equivalent MSS spectral image of the same scene.

Ross, D. S.↗

Data storage, image tube type

Method and apparatus for the storage of digital or analog electrical signals are provided by a memory storage system employing a conventional vidicon tube. At the beginning of an operating cycle, the vidicon is conditioned to accept electrical data input by exposing its photosensitive target to a short, high intensity light flash. A first electron beam scan of the photosensitive surface then sets up a charge pattern on the photosensitive target. A second electron beam scan of the photosensitive surface by an unmodulated electron beam then develops an output signal across an output resistor by using capacitive currents. The conditioning and scanning steps are operated repetitively at high speed using conventional television camera scan, sync, and power supply circuitry to provide a low cost data storage system.

Lipoma, P. C.↗

Television photometry - The Mariner 9 experience

Television photometry is compared to conventional techniques. Reduced data from Mariner 9 cameras should, under optimum conditions, have been accurate to a few percent. However, a combination of unstable camera properties and various unfortunate circumstances produced serious nonlinearities and other systematic errors. The means of estimating these errors are described in detail; they lean heavily on the fortuitous presence of a few specks of dust on the faceplate of one vidicon. Crude corrections will probably improve the photometric quality for the two most-used filter positions of the A camera. It would be very difficult to improve the photometry further. In view of their low photometric accuracy and detective quantum efficiency vidicons do not seem likely to replace conventional photography, except for special applications.

Young, A. T.↗

Ultraviolet corona detection sensor study

The feasibility of detecting electrical corona discharge phenomena in a space simulation chamber via emission of ultraviolet light was evaluated. A corona simulator, with a hemispherically capped point to plane electrode geometry, was used to generate corona glows over a wide range of pressure, voltage, current, electrode gap length and electrode point radius. Several ultraviolet detectors, including a copper cathode gas discharge tube and a UV enhanced silicon photodiode detector, were evaluated in the course of the spectral intensity measurements. The performance of both silicon target vidicons and silicon intensified target vidicons was evaluated analytically using the data generated by the spectroradiometer scans and the performance data supplied by the manufacturers.

Schmitt, R. J.↗

A computer-aided telescope pointing system utilizing a video star tracker

The Video Inertial Pointing (VIP) System is being developed to satisfy the acquisition and pointing requirements of astronomical telescopes. VIP employs a single video sensor to generate three-axis pointing error signals and to provide inputs for a cathode ray tube (CRT) display of the star field. The pointing error signals update the telescope's gyro stabilization system. The CRT display facilitates target acquisition and positioning of the telescope by a remote operator. The present paper describes the analysis, simulation, and hardware development of a prototype, advanced VIP system. An early model of the system utilizing a silicon-intensified target vidicon camera has flown on a balloon-borne telescope and is briefly described. The advanced system, which can employ either a vidicon camera or a charge-coupled device video sensor, has been tested using an analog/digital hybrid simulation. The advanced VIP hardware is described, and the simulation results presented.

Lorell, K. R.↗

Photometric imaging of Mars during the 1973 opposition

The paper discusses imaging of Mars at 20 wavelengths in the spectral region from 0.35 to 1.10 microns performed during the 1973 opposition with a photometric imaging system that uses a silicon vidicon tube as the detector. The imaging system and data-reduction procedures are described in detail, and relative reflectance spectra for several small areas in the images are presented along with vidicon images obtained during early phases in the development of the 1973 dust storms. Several anomalous blue brightenings are examined and attributed to ground fog and H2O frost. It is suggested that anomalously large amounts of H2O were pulsed into the atmosphere from the regolith by the storm system. An apparent fading and recession of the north polar hood is noted, surface units revealed in contrast-enhanced ratio images are identified, and the need for higher-spatial-resolution orbital spectroscopy of dark areas is emphasized.

Mccord, T. B.↗