Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VENTILATION SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

The impact of simplified window and exhaust fan assumptions on indoor air quality in multifamily buildings

In residential buildings, the indoor air quality can be significantly affected by ventilation measures initiated by occupants, including the operation of windows and in-unit exhaust fans in kitchens and bathrooms. Many simulations simplify these factors by disregarding window opening behaviors and using fixed schedules for exhaust fan operation across all residential units. To estimate the impact of these simplifications in the U.S. context, this study used coupled CONTAM and EnergyPlus models to simulate airflow and contaminant transport in multifamily buildings. The coupled models parametrically varied climate zone, building airtightness, and mechanical ventilation system types. The study conducted a sensitivity analysis on two key occupant behaviors: (1) operating kitchen and bathroom exhausts on different schedules in individual dwelling units, and (2) scheduling open windows on ground and top floors. The simplified assumptions (i.e. uniform in-unit exhaust fan operation and window operation) had a minimal impact on inter-unit air flow and contaminant transport simulations across a broad range of building air leakage and mechanical ventilation system types. These findings suggest that for buildings with tight construction it is reasonable for most modelling and simulation efforts to ignore the effects of non-uniform exhaust fan operation and window opening.

Occupant behavior↗

Crew Survivability After a Rapid Cabin Depressurization Event

Anecdotal evidence acquired through historic failure investigations involving rapid cabin decompression (e.g. Challenger, Columbia and Soyuz 11) show that full evacuation of the cabin atmosphere may occur within seconds. During such an event, the delta-pressure between the sealed suit ventilation system and the cabin will rise at the rate of the cabin depressurization; potentially at a rate exceeding the capability of the suit relief valve. It is possible that permanent damage to the suit pressure enclosure and ventilation loop components may occur as the integrated system may be subjected to delta pressures in excess of the design to pressures. Additionally, as the total pressure of the suit ventilation system decreases, so does the oxygen available to the crew. The crew may be subjected to a temporary incapacitating, but non-lethal, hypoxic environment. It is expected that the suit will maintain a survivable atmosphere on the crew until the vehicle pressure control system recovers or the cabin has otherwise attained a habitable environment. A common finding from the aforementioned reports indicates that the crew would have had a better chance at surviving the event had they been in a protective configuration, that is, in a survival suit. Making use of these lessons learned, the Constellation Program implemented a suit loop in the spacecraft design and required that the crew be in a protective configuration, that is suited with gloves on and visors down, during dynamic phases of flight that pose the greatest risk for a rapid and uncontrolled cabin depressurization event: ascent, entry, and docking. This paper details the evaluation performed to derive suit pressure garment and ventilation system performance parameters that would lead to the highest probability of crew survivability after an uncontrolled crew cabin depressurization event while remaining in the realm of practicality for suit design. This evaluation involved: (1) assessment of stakeholder expectations to validate the functionality being imposed; (2) review/refinement of concept of operations to establish the potential triggers for such an event and define the response of the spacecraft and suit ventilation loop pressure control systems; and (3) assessment of system capabilities with respect to structural capability and pressure control. 1 Crew and Thermal Systems Division, NASA Johnson Space Center, Mail Code: AES29, 2101 NASA Parkway, Houston,

Sargusingh, Miriam J.↗

Crew Survivability After a Rapid Cabin Depressurization Event

Anecdotal evidence acquired through historic failure investigations involving rapid cabin decompression (e.g. Challenger, Columbia and Soyuz 11) show that full evacuation of the cabin atmosphere may occur within seconds. During such an event, the delta-pressure between the sealed suit ventilation system and the cabin will rise at the rate of the cabin depressurization; potentially at a rate exceeding the capability of the suit relief valve. It is possible that permanent damage to the suit pressure enclosure and ventilation loop components may occur as the integrated system may be subjected to delta pressures in excess of the design-to pressures. Additionally, as the total pressure of the suit ventilation system decreases, so does the oxygen available to the crew. The crew may be subjected to a temporarily incapacitating, but non-lethal, hypoxic environment. It is expected that the suit will maintain a survivable atmosphere on the crew until the vehicle pressure control system recovers or the cabin has otherwise attained a habitable environment. A common finding from the aforementioned reports indicates that the crew would have had a better chance at surviving the event had they been in a protective configuration, that is, in a survival suit. Making use of these lessons learned, the Constellation Program implemented a suit loop in the spacecraft design and required that the crew be in a protective configuration, that is suited with gloves on and visors down, during dynamic phases of flight that pose the greatest risk for a rapid and uncontrolled cabin depressurization event: ascent, entry, and docking. This paper details the evaluation performed to derive suit pressure garment and ventilation system performance parameters that would lead to the highest probability of crew survivability after an uncontrolled crew cabin depressurization event while remaining in the realm of practicality for suit design. This evaluation involved: (1) assessment of stakeholder expectations to validate the functionality being imposed; (2) review/refinement of concept of operations to establish the potential triggers for such an event and define the response of the spacecraft and suit ventilation loop pressure control systems; and (3) assessment of system capabilities with respect to structural capability and pressure control.

Sargusingh, Miriam J.↗

Spacecraft Cabin Air Quality Control and Its Application to Tight Buildings

Air quality is an important consideration not only for the external environment, but also for the indoor environment. Most people spend a majority of their lives indoors and the air that they breathe is important to their physical and emotional well being. Since most modern building designs have focused on energy efficiency, less fresh air is brought from the outside. As a result, pollutants from building materials, furniture, cleaning, and cooking have no place to go. To make matters worse, most ventilation systems do not include any means for removing pollutants from the recycled air. Unfortunately, pollution at even a small level can result in eye, throat, and lung irritation in addition to chronic headaches, nausea, and fatigue. A spacecraft cabin, which represents the worst case in tight building design, requires special consideration of air quality since any effects pollutants may have on a crewmember can potentially place a mission or other crewmembers at risk. A detailed approach has been developed by the National Aeronautics and Space Administration (NASA) to minimize cabin atmosphere pollution and provide the crew with an environment which is as free of pollutants as possible. This approach is a combination of passive and active contamination control concepts involving the evaluation and selection of materials to be used onboard the spacecraft, the establishment of air quality standards to ensure crew health, and the use of active control means onboard the spacecraft to further ensure an acceptable atmosphere. This approach has allowed NASA to prevent illness by providing crewmembers with a cabin atmosphere which contains pollutant concentrations up to 100 times lower than those specified for terrestrial indoor environments. Standard building construction, however, does not take into account the potentially harmful effects of materials used in the construction process on the health of future occupants and relies primarily on remedial rather than preventive techniques when addressing contamination. This approach results in a building that theoretically has low operating costs, but may actually have high costs associated with lost work days, increased medical claims, decreased productivity, and problem remediation. A similar approach to NASA's may be adopted by the building construction community which can tap the extensive database of material offgassing properties that has been collected to support the space program. Many materials used by NASA are commercially available and are frequently used in building construction. In addition, computer models which have been developed for assessing various methods of active contamination control can be applied to building ventilation system design and the analysis of their economics. Through using NASA' s experience, the expense associated with the current remedial approach can be avoided.

Perry, J. L.↗

Winnett Public School District Energy Improvements

The Winnett Public School District Energy Improvement Project was funded through the U.S. Department of Energy's Renew America's Schools Program, which supports rural and underserved school districts in upgrading aging facilities and improving energy performance. The completed improvements directly advance the program's objectives by replacing the District's outdated coal-fired heating system with a modern, high-efficiency propane boiler system, while also enhancing ventilation systems and building envelope performance throughout the school. These upgrades provide a more reliable heating system and improved indoor air quality, creating a healthier and more comfortable environment for students and staff. In addition, replacing the aging boiler system has reduced long-term maintenance demands for one of Montana's most rural school districts, allowing the District to redirect limited financial resources toward other critical needs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental system for the control of surgically induced infections

The experimental system is described, and the procedures for surgery usage and maintenance are outlined. Basically the system consists of the following: (1) a portable clean room comprised of a horizontal laminar flow filter system and a transparent walled enclosure, (2) a helmet-shoulder pad assembly, (3) a communications system, (4) a helmet ventilation system, and (5) surgical gowns.

Source record↗

Investigation of ventilation-coupled high energy density sensible thermal energy storage

Low-cost energy storage will play an important role in supporting the decarbonization of the energy sector. Here, a novel approach to thermal energy storage for buildings is proposed, in which a tank of antifreeze liquid can be used to heat outdoor air in mechanical ventilation systems. If heated to a high enough temperature, the fluid can potentially undergo temperature swings of nearly 100°C during discharge in cold climates. Because the energy density of sensible storage systems scales proportionally to the system temperature change, this concept has the potential to offer higher energy densities than other liquid-based sensible storage devices used in building applications. A one-dimensional numerical model of the storage system was developed and experimentally validated using 30 wt% (wt%) potassium acetate as an aqueous antifreeze solution. Using a commercial hot water tank, energy densities of 47.0 kW-hour per cubic meter (kWh/m 3 ) were demonstrated in a laboratory setting. Material energy densities of approximately 74.7 (kWh/m 3 ) were measured. Design improvements may boost this energy storage density even further. Because of the system's relative simplicity, ventilation-coupled sensible storage has the potential to be an easily deployable, low-cost energy storage solution for building systems.

25 ENERGY STORAGE↗

Update on ASME AG-1 and Revision of the DOE Nuclear Air Cleaning Handbook - 20536

The American Society of Mechanical Engineers AG-1 Code on Nuclear Air and Gas Treatment is updated every two years. This paper provides an overview of issues being discussed within AG-1 committee meetings and revisions that will be included in the next version of the code. Additional information is provided on issues being discussed ranging from media velocity limits, control of airflow using actual versus and standard cubic feet per minute. Navigation and identification of applicable high-efficiency particulate air (HEPA) filter code sections can be confusing for those unfamiliar with AG-1. A general reorganization of filtration code sections clarifies geometry, flow, and performance envelopes for nuclear grade HEPA filters. The initial step consists of establishment of Section FN covering qualification of conventional, ceramic, metal, and high strength fibrous glass media. Future filter sections are currently expected to be characterized by geometry and flow direction (axial vs. radial). The Department of Energy's (DOE) Nuclear Air Cleaning Handbook (NACH) is also undergoing revision. An update on the status of that effort, along with issues and changes being considered. The original charter of the AG-1 Code was specific to commercial nuclear power plants, and to safety-related air cleaning systems. This has evolved over the years to include normal non-safety ventilation systems and process gas systems. Corollary guidance for DOE facilities has been available in several editions of the Nuclear Air Cleaning Handbook, starting with ORNL-NSIC 65. The latest edition of the Handbook, 2003, is undergoing revision and modifications. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TCCR Operational Summary and Optimization for Tank 9 Processing - 20314

Savannah River Remediation (SRR) manages and operates the liquid waste facilities at Savannah River Site (SRS) for the Department of Energy (DOE). Stored liquid waste is a complex mixture of insoluble solids (sludge) and soluble salts in an alkaline solution. SRR has deployed the Tank Closure Cesium Removal (TCCR) system, a tank-side ion exchange process, to remove radioactive cesium from salt waste and enable onsite disposal of the resulting decontaminated salt solution as low-level waste at the Saltstone facilities. The TCCR system consists of two prefilters, four ion exchange (IX) columns, one resin trap, and a ventilation system. The IX process uses a form of inorganic crystalline silicotitanate (CST), which has a high affinity for cesium and other alkali metals, strontium, and actinides. This process is currently deployed utilizing salt feed from Tank 10, with future plans to dissolve solid salt in Tank 9 and transfer the salt solution to Tank 10 for processing through TCCR. The feed for TCCR must be created from salt-cake in Tank 10 through a dissolution process. Once enough salt has been dissolved, a qualification process is entered. This process characterizes the feed and ensures the cesium loading on the columns will not cause boiling of waste within the columns during or after processing. Once the batch has been qualified, salt waste is fed to the TCCR system through a transfer pump in the center of the tank. The waste is filtered through a set of two shielded, dead-end prefilters that prevent solids buildup in the columns. The filtered salt solution then travels to the shielded IX columns, which can be operated individually or in series, where the cesium is sorbed on the CST media. The decontaminated salt solution (DSS) then travels through a resin trap and out of the module to Tank 11. TCCR has successfully processed approximately 795,000 L of Tank 10H radioactive salt waste over two batches to date. There has not yet been a system induced shutdown. The prefilters performed as expected with only minor degradation in recovery of differential pressure after a backflush sequence. The time between backflushes decreased as each batch reached the end of processing. The hydraulics in the IXCs mostly performed as expected at all flow rates, except for one IXC that will be further investigated during Batch 3 processing. The TCCR system has shown some opportunities for more efficient processing during the length of the demonstration so far. For future processing of material from Tank 9H through Tank 10H and the TCCR unit, TCCR 1A will implement changes to the prefilters and the IXCs. The prefilters will have an increased surface area and a new filter media in an effort to increase time between filter swaps and improve backwashing cleaning capability. The IXCs will have a reduced diameter to allow for increased heat transfer out of the column and increased loading of Cs-137. Additionally, a new form of CST with an increased kinetic performance is being investigated for use during TCCR 1A operation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Review of Lunar Dust Computational Fluid Dynamic Model Development, Applications, and Validation for Habitable Volumes

As humans look to return to the lunar surface, Environmental Control and Life Support Systems (ECLSS) must be able to control lunar dust concentrations to minimize impacts to crew health and equipment within the cabin environment. Lunar dust is abrasive and can deteriorate the performance of spacesuits and equipment inside of habitable volumes. Development and validation of computational fluid dynamic (CFD) models assist in understanding the behavior of lunar dust and aids in design of ECLS systems. Previous analysis efforts include modeling the effect of lunar dust on the crew's health, devices to filter out lunar dust from ventilation systems, and module ventilation to predict where lunar dust would settle in modules. This paper is a literature review of the modeling and testing techniques currently used in industry to analyze how lunar dust will affect ECLSS functionality. Details about lunar dust material properties and knowledge gaps are also examined.

Monica Mah↗

Apparatus for Sizing and Rewinding Graphite Fibers

Equipment ideally suited for research and development of new sizing solutions. Designed expecially for applying thermoplastic sizing solutions to graphite tow consisting of 3,000 to 12,000 filaments per tow, but accommodates other solutions, filament counts, and materials other than graphite. Closed system containing highly volatile methylene chloride vapors. Also ventilation system directly over resin reservoir. Concept used to apply sizing compounds on fiber tows or yarn-type reinforcement materials used in composite technology. Sizing solutions consist of compounds compatible with thermosets as well as thermoplastics.

Wilson, M. L.↗

Cooling system for removing metabolic heat from an hermetically sealed spacesuit

An improved cooling and ventilating system is described for removing metabolic heat, waste gases and water vapor generated by a wearer of an hermetically sealed spacesuit. The cooling system was characterized by a body suit, having a first circuit for simultaneously establishing a cooling flow of water through the thorax and head sections of the body suit. Circulation patches were included mounted in the thorax section and head section of the body suit. A second circuit for discharing a flow of gas throughout the spacesuit and a disconnect unit for coupling the circuits with a life support system externally related to the spacesuit were provided.

Webbon, B. W.↗

Portable Airflow Meter

Compact hand-held instrument measures airflow. Consists of hot-wire anemometer probe in flow-straightening tube that reduces swirling. Configuration developed empirically to reduce length of instrument to practical dimension for use and storage in confined space. Two versions of new straightener only 17 and 18 in. long. Weighs less than 8 lb. and readily stored on Space Shuttle, developed to measure airflow in waster-collection system during flight. Used on Earth to measure airflow in ventilation systems, vacuum cleaners, and the like.

Burgett, Frank A.↗

Dynamics of airborne fungal populations in a large office building

The increasing concern with bioaerosols in large office buildings prompted this prospective study of airborne fungal concentrations in a newly constructed building on the Gulf coast. We collected volumetric culture plate air samples on 14 occasions over the 18-month period immediately following building occupancy. On each sampling occasion, we collected duplicate samples from three sites on three floors of this six-story building, and an outdoor sample. Fungal concentrations indoors were consistently below those outdoors, and no sample clearly indicated fungal contamination in the building, although visible growth appeared in the ventilation system during the course of the study. We conclude that modern mechanically ventilated buildings prevent the intrusion of most of the outdoor fungal aerosol, and that even relatively extensive air sampling protocols may not sufficiently document the microbial status of buildings.

NASA Program Biomedical Research and Countermeasur↗

Indoor air quality in California homes with code-required mechanical ventilation

Data were collected in 70 detached houses built in 2011-2017 in compliance with the mechanical ventilation requirements of California's building energy efficiency standards. Each home was monitored for a 1-week period with windows closed and the central mechanical ventilation system operating. Pollutant measurements included time-resolved fine particulate matter (PM 2.5 ) indoors and outdoors and formaldehyde and carbon dioxide (CO 2 ) indoors. Time-integrated measurements were made for formaldehyde, NO 2 , and nitrogen oxides (NO X ) indoors and outdoors. Operation of the cooktop, range hood, and other exhaust fans was continuously recorded during the monitoring period. Onetime diagnostic measurements included mechanical airflows and envelope and duct system air leakage. All homes met or were very close to meeting the ventilation requirements. On average, the dwelling unit ventilation fan moved 50% more airflow than the minimum requirement. Pollutant concentrations were similar to or lower than those reported in a 2006-2007 study of California new homes built in 2002-2005. Mean and median indoor concentrations were lower by 44% and 38% for formaldehyde and 44% and 54% for PM 2.5 . Ventilation fans were operating in only 26% of homes when first visited, and the control switches in many homes did not have informative labels as required by building standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Integrated energy balance analysis for Space Station Freedom

An integrated simulation model is described which characterizes the dynamic interaction of the energy transport subsystems of Space Station Freedom for given orbital conditions and for a given set of power and thermal loads. Subsystems included in the model are the Electric Power System (EPS), the Internal Thermal Control System (ITCS), the External Thermal Control System (ETCS), and the cabin Temperature and Humidity Control System (THC) (which includes the avionics air cooling, cabin air cooling, and intermodule ventilation systems). Models of the subsystems were developed in a number of system-specific modeling tools and validated. The subsystem models are then combined into integrated models to address a number of integrated performance issues involving the ability of the integrated energy transport system of Space Station Freedom to provide power, controlled cabin temperature and humidity, and equipment thermal control to support operations.

Tandler, John↗

Colonization by Cladosporium spp. of painted metal surfaces associated with heating and air conditioning systems

Cladosporium cladosporioides and C. hebarum colonized painted metal surfaces of covering panels and register vents of heating, air conditioning and ventilation systems. Hyphae penetrated the paint film and developed characteristic conidiophores and conidia. The colonies were tightly appressed to the metal surface and conidia were not readily detectable via standard air sampling procedures.

NASA Program Environmental Health↗

Smart Ventilation Controls for Occupancy and Auxiliary Fan Use Across U.S. Climates

Smart Ventilation has been developed as a way to reduce the energy associated with ventilation by changing when ventilation happens and how much ventilation occurs at any given time. In high performance buildings with low envelope and appliance related loads, ventilation is becoming a bigger part of the total building energy use and needs to be addressed if performance targets are to be met. This work explores the development and performance of smart ventilation controls based on occupancy and auxiliary fan operation that provide annual dwelling unit ventilation equivalence to ASHRAE Standard 62.2-2016. A prototype high performance home compliant with U.S. DOE Building America Zero Energy Ready program requirements was simulated using the REGCAP tool with and without smart controls across 15 U.S. DOE climate zones. Balanced and unbalanced IAQ fans were independently simulated, and all smart controlled fans had airflows double the reference 62.2-2016 airflow. Three idealized occupancy patterns were examined: 1st shift (a typical daily work/school absence), an extended 1st shift with more time spent out of the home evenings and weekends and 3rd shift (night work). The Occupancy controller turns the IAQ fan off during unoccupied periods, and it resumes ventilation upon their return. While unoccupied, contaminants are allowed to accumulate in the space, because occupants are not exposed to these contaminants. When occupants return home, they are exposed to these higher contaminant concentrations, and the controller increases the ventilation rate sufficiently to ensure equivalence with a continuous IAQ fan. Accounting for pollutant emissions that occur during unoccupied periods (as required by ASHRAE 62.2-2016), sharply distinguishes our occupancy controls from past Demand Controlled Ventilation systems. This new accounting method results in equivalent contaminant exposure, as well as lower reductions in average ventilation rates and lower energy savings. Smart controls were demonstrated that saved HVAC energy (i.e., avoided heating/cooling load, as well as fan energy)—averaging between 6 and 46% of ventilation-related energy use depending on the control strategy and occupancy pattern assumptions. The greatest savings were in the combined Auxiliary Fan + Occupancy control. Energy savings increased with climate heating demand and longer unoccupied time periods. The 3rd shift occupancy pattern had better performance, due to the thermal benefit of reducing the ventilation rate during the cold nighttime hours. This same effect provided a cooling energy benefit in hotter locations for the 1st shift. Overall, savings from occupancy-based smart controls were low, because of the recovery period required after occupants return home, during which the airflow is double the 62.2 reference. This recovery is required to maintain equivalence with the ASHRAE standard. Occupancy-based control performance was improved when combined with sensing auxiliary fans and when providing a pre-occupancy flush out of one- or two-hours. Performance was similarly improved if the ASHRAE Standard were to recognize that pollutant emissions are lower during unoccupied periods, iii allowing a lower target ventilation rate during unoccupied periods (not currently in the standard) (see Full vs. Half AEQ in this report). Finally, over-sized unbalanced fans that are cycled on-and-off by a smart controller (or timer) were found to substantially increase annual average air exchange and energy use relative to a continuous unbalanced fan due to the effects of superposition with natural infiltration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗