Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ultrasound”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Using AI Segmentation Models to Improve Foreign Body Detection and Triage from Ultrasound Images

Medical imaging can be a critical tool for triaging casualties in trauma situations. In remote or military medicine scenarios, triage is essential for identifying how to use limited resources or prioritize evacuation for the most serious cases. Ultrasound imaging, while portable and often available near the point of injury, can only be used for triage if images are properly acquired, interpreted, and objectively triage scored. Here, we detail how AI segmentation models can be used for improving image interpretation and objective triage evaluation for a medical application focused on foreign bodies embedded in tissues at variable distances from critical neurovascular features. Ultrasound images previously collected in a tissue phantom with or without neurovascular features were labeled with ground truth masks. These image sets were used to train two different segmentation AI frameworks: YOLOv7 and U-Net segmentation models. Overall, both approaches were successful in identifying shrapnel in the image set, with U-Net outperforming YOLOv7 for single-class segmentation. Both segmentation models were also evaluated with a more complex image set containing shrapnel, artery, vein, and nerve features. YOLOv7 obtained higher precision scores across multiple classes whereas U-Net achieved higher recall scores. Using each AI model, a triage distance metric was adapted to measure the proximity of shrapnel to the nearest neurovascular feature, with U-Net more closely mirroring the triage distances measured from ground truth labels. Overall, the segmentation AI models were successful in detecting shrapnel in ultrasound images and could allow for improved injury triage in emergency medicine scenarios.

47 OTHER INSTRUMENTATION↗

Evaluation of Deep Learning Model Architectures for Point-of-Care Ultrasound Diagnostics

Point-of-care ultrasound imaging is a critical tool for patient triage during trauma for diagnosing injuries and prioritizing limited medical evacuation resources. Specifically, an eFAST exam evaluates if there are free fluids in the chest or abdomen but this is only possible if ultrasound scans can be accurately interpreted, a challenge in the pre-hospital setting. In this effort, we evaluated the use of artificial intelligent eFAST image interpretation models. Widely used deep learning model architectures were evaluated as well as Bayesian models optimized for six different diagnostic models: pneumothorax (i) B- or (ii) M-mode, hemothorax (iii) B- or (iv) M-mode, (v) pelvic or bladder abdominal hemorrhage and (vi) right upper quadrant abdominal hemorrhage. Models were trained using images captured in 27 swine. Using a leave-one-subject-out training approach, the MobileNetV2 and DarkNet53 models surpassed 85% accuracy for each M-mode scan site. The different B-mode models performed worse with accuracies between 68% and 74% except for the pelvic hemorrhage model, which only reached 62% accuracy for all model architectures. These results highlight which eFAST scan sites can be easily automated with image interpretation models, while other scan sites, such as the bladder hemorrhage model, will require more robust model development or data augmentation to improve performance. With these additional improvements, the skill threshold for ultrasound-based triage can be reduced, thus expanding its utility in the pre-hospital setting.

47 OTHER INSTRUMENTATION↗

Noninvasive Detection, Tracking, and Characterization of Aerogel Implants Using Diagnostic Ultrasound

Medical implants are routinely tracked and monitored using different techniques, such as MRI, X-ray, and ultrasound. Due to the need for ionizing radiation, the two former methods pose a significant risk to tissue. Ultrasound imaging, however, is non-invasive and presents no known risk to human tissue. Aerogels are an emerging material with great potential in biomedical implants. While qualitative observation of ultrasound images by experts can already provide a lot of information about the implants and the surrounding structures, this paper describes the development and study of two simple B-Mode image analysis techniques based on attenuation measurements and echogenicity comparisons, which can further enhance the study of the biological tissues and implants, especially of different types of biocompatible aerogels.

36 MATERIALS SCIENCE↗

Laser Based Ultrasound for Verification of Circuit Card Assemblies

This IR is a follow-up conference Paper to the IR approved abstract; PNNL-SA-194096. --- Verification that equipment is authentic and not changed; even at the circuit card assembly (CCA) level will likely be an important component of future arms control treaties. This effort was an initial evaluation of the potential for laser-based ultrasound (LBU) as an inspection tool for Unique Identification (UID) of Circuit Card Assembly (CCA) boards and CCA components. The LBU system used a laser pulse for ultrasound generation and an Optical Microphone for ultrasound detection to image subsurface structures without physical contact and in a dry state. This paper described the selected CCA surrogate, CCA components that were examined, the LBU system, LBU images of the CCA components, and the initial development of UID algorithms. Receiver operating characteristics (ROC) curves indicated good performance for two algorithms as a potential means for UID of CCA boards and CCA components.

Laser Ultrasound, Equipment Verification, Arms Con↗

Improving the bioaccessibility of lipophilic ingredient in its oral intestinal delivery by ultrasound and biological cross‐linker

Abstract BACKGROUND Great efforts have been made to improve the oral bioaccessibility of lipophilic ingredients with multi‐functionalities. Achieving intestinal delivery of lipophilic ingredients and their encapsulation in micelles composed of bile salts and lipid hydrolysates (i.e. fatty acids) is critical for improving oral bioaccessibility. Therefore, oil‐core microcapsules are considered ideal carriers of lipophilic ingredients. Previous studies have reported oil‐core/zein‐shell microcapsules constructed by a one‐step anti‐solvent process. Still, its efficacy as an intestinal delivery system was limited because if the porous shell structure. RESULTS Zein solution was pretreated with ultrasound and tannic acid (TA) cross‐linking. Composite oil‐core microcapsule (COM) with a compact shell structure was successfully prepared by using modified zein solution in the anti‐solvent process. Fourier‐transform infrared spectroscopy and circular dichroism analyses indicated that ultrasound and TA synergistically promote the conformational transition of zein from α‐helix to β‐sheet and enhance the hydrophobic interactions among protein chains. The above changes contribute to the strengthen of shell zein network. Correspondingly, COM presents superior encapsulation efficiency and environmental stability over the simple oil‐core microcapsule (SOM) prepared without the use of ultrasound and TA. Furthermore, antioxidant activity of β‐carotene was well retained during the encapsulation process. In vitro studies indicated that COM was more resistant to digestibility and acid‐induced swelling. More than 87% of β‐carotene could be released in the intestine in a sustainable way. The controllable release behavior thus promoted a significant increase in bioaccessibility of β‐carotene encapsulated in COM compared to SOM (85.9% versus 48.5%). CONCLUSION The COM generated here shows potential for bioaccessibility improvement of lipophilic ingredients. © 2022 Society of Chemical Industry.

Wei, Yun‐Shan↗

Ultrasound and X-ray Cross-Characterization of a Graded Impedance Impactor used for Shock-Ramp Compression Experiments

Abstract In this work we perform ultrasound measurements on an impedance graded impactor made by tape casting magnesium, copper, and tungsten. We also destructively extract small representative samples from the part for complementary characterization with x-ray computed tomography. Combining the two data sets enables direct assignment of some of the measured ultrasound features to specific material characteristics identified by x-ray tomography. Our results demonstrate how ultrasound inspection, informed by x-ray computed tomography, can be used to identify sub-millimeter material amalgamations and spatial heterogeneities in this graded material.

36 MATERIALS SCIENCE↗

Ringing Artifact Reduction Method for Ultrasound Reconstruction Using Multi-Agent Consensus Equilibrium

Non-destructive characterization of multi-layered structures that can be accessed from only a single side is important for applications such as well-bore integrity inspection. Existing methods related to Synthetic Aperture Focusing Technique (SAFT) rapidly produce acceptable results but with significant artifacts. Recently, ultrasound model-based iterative reconstruction (UMBIR) approaches have shown significant improvements over SAFT. However, even these methods produce ringing artifacts due to the high fractional-bandwidth of the excitation signal.In this paper, we propose a ringing artifact reduction method for ultrasound image reconstruction that uses a multi-agent consensus equilibrium (RARE-MACE) framework. Our approach integrates a physics-based forward model that accounts for the propagation of a collimated ultrasonic beam in multi-layered media, a spatially varying image prior, and a denoiser designed to suppress the ringing artifacts that are characteristic of reconstructions from high-fractional bandwidth ultrasound sensor data. We test our method on simulated and experimental measurements and show substantial improvements in image quality compared to SAFT and UMBIR.

Alanazi, Abdulrahman M↗

Training Ultrasound Image Classification Deep-Learning Algorithms for Pneumothorax Detection Using a Synthetic Tissue Phantom Apparatus

Ultrasound (US) imaging is a critical tool in emergency and military medicine because of its portability and immediate nature. However, proper image interpretation requires skill, limiting its utility in remote applications for conditions such as pneumothorax (PTX) which requires rapid intervention. Artificial intelligence has the potential to automate ultrasound image analysis for various pathophysiological conditions. Training models require large data sets and a means of troubleshooting in real-time for ultrasound integration deployment, and they also require large animal models or clinical testing. Here, we detail the development of a dynamic synthetic tissue phantom model for PTX and its use in training image classification algorithms. The model comprises a synthetic gelatin phantom cast in a custom 3D-printed rib mold and a lung mimicking phantom. When compared to PTX images acquired in swine, images from the phantom were similar in both PTX negative and positive mimicking scenarios. We then used a deep learning image classification algorithm, which we previously developed for shrapnel detection, to accurately predict the presence of PTX in swine images by only training on phantom image sets, highlighting the utility for a tissue phantom for AI applications.

Boice, Emily N. (ORCID:0000000171802842)↗

Applications of Doppler ultrasound in clinical vascular disease

Doppler ultrasound has become the most useful and versatile noninvasive technique for objective evaluation of clinical vascular disease. Commercially available continuous-wave instruments provide qualitative and quantitative assessment of venous and arterial disease. Pulsed Doppler ultrasound was developed to provide longitudinal and transverse cross-sectional images of the arterial lumen with a resolution approaching that of conventional X-ray techniques. Application of Doppler ultrasound in venous, peripheral arterial, and cerebrovascular diseases is reviewed.

Barnes, R. W.↗

Laser Sources for Generation of Ultrasound

Two laser systems have been built and used to demonstrate enhancements beyond current technology used for laser-based generation and detection of ultrasound. The first system consisted of ten Nd:YAG laser cavities coupled electronically and optically to permit sequential bursts of up to ten laser pulses directed either at a single point or configured into a phased array of sources. Significant enhancements in overall signal-to-noise ratio for laser ultrasound incorporating this new source system was demonstrated, using it first as a source of narrowband ultrasound and secondly as a phased array source producing large enhanced signal displacements. A second laser system was implemented using ultra fast optical pulses from a Ti:Sapphire laser to study a new method for making laser generated ultrasonic measurements of thin films with thicknesses on the order of hundreds of angstroms. Work by prior investigators showed that such measurements could be made based upon fluctuations in the reflectivity of thin films when they are stressed by an arriving elastic pulse. Research performed using equipment purchased under this program showed that a pulsed interferometric system could be used as well as a piezoreflective detection system to measure pulse arrivals even in thin films with very low piezoreflective coefficients.

Wagner, James W.↗

Ultrasound Techniques for Space Applications

Ultrasound has proven to be a safe non-invasive technique for imaging organs and measuring cardiovascular function. It has unique advantages for application to problems with man in space including evaluation of cardiovascular function both in serial studies and during critical operations. In addition, specialized instrumentation may be capable of detecting the onset of decompression sickness during EVA activities. A spatial location and three-dimensional reconstruction system is being developed to improve the accuracy and reproducibility for serial comparative ultrasound studies of cardiovascular function. The three-dimensional method permits the acquisition of ultrasonic images from many views that can be recombined into a single reconstruction of the heart or vasculature. In addition to conventional imaging and monitoring systems, it is sometimes necessary or desirable to develop instrumentation for special purposes. One example of this type of development is the design of a pulsed-Doppler system to monitor cerebral blood flow during critical operations such as re-entry. A second example is the design of a swept-frequency ultrasound system for the detection of bubbles in the circulatory system and/or soft tissues as an early indication of the onset of decompression sickness during EVA activities. This system exploits the resonant properties of bubbles and can detect both fundamental and second harmonic emissions from the insonified region.

Rooney, James A.↗

Measurement of Transcranial Distance During Head-Down Tilt Using Ultrasound

Exposure to microgravity probably elevates blood pressure and flow in the head which may increase intracranial volume (ICV) and pressure (ICP). Due to the slightly compliant nature of the cranium, any increase of ICP will increase ICV and transcranial distance. We used a noninvasive ultrasound technique to measure transcranial distance (frontal to occipital) during head-down tilt. Seven subjects (ages 26-53) underwent the following tilt angles: 90 deg. upright, 30 deg., 0 deg., -6 deg., -10 deg., -6 deg., 0 deg., 30 deg., and 90 deg. Each angle was maintained for 1 min. Ultrasound wave frequency was collected continuously and transcranial distance was calculated (Delta(x) = x(Delta)f/f, where x is path length and f is frequency of the wave) for each tilt angle. Frequency decreased from 503.687 kHz (90 deg. upright) to 502.619 kHz (-10 deg.). These frequencies translated to an increased transcranial distance of 0.403 mm. Although our data suggest a significant increase in transcranial distance during head-down tilt, this apparent increase may result, in part, from head-down tilt-induced subcutaneous edema or cutaneous blood volume elevation. In three subjects, when the above protocol was repeated with an ace bandage wrapped around the head to minimize such edema, the increased transcranial distance from 90 deg. to -10 deg. was reduced by 0.174 mm. Further development of the technique to quantify bone-to-bone expansion unconfounded by cutaneous fluid is necessary. Therefore, this ultrasound technique may provide measurements of changes in cranial dimensions during microgravity.

Torikoshi, Shigeyo↗

Non-Invasive Measurement of Intracranial Pressure Pulsation using Ultrasound

Exposure to microgravity causes a cephalad fluid shift which may elevate intracranial pressure (ICP). Elevation in ICP may affect cerebral hemodynamics in astronauts during space flight. ICP is, however, a difficult parameter to measure due to the invasiveness of currently available techniques. We already reported our development of a non-invasive ultrasound device for measurement of ICP. We recently modified the device so that we might reproducibly estimate ICP changes in association with cardiac cycles. In the first experiment, we measured changes in cranial distance with the ultrasound device in cadavera while changing ICP by infusing saline into the lateral ventricle. In the second experiment, we measured changes in cranial distance in five healthy volunteers while placing them in 60 deg, 30 deg head-up tilt, supine, and 10 deg head-down tilt position. In the cadaver study, fast Fourier transformation revealed that cranial pulsation is clearly associated with ICP pulsation. The ratio of cranial distance and ICP pulsation is 1.3microns/mmHg. In the tilting study, the magnitudes of cranial pulsation are linearly correlated to tilt angles (r=0.87). The ultrasound device has sufficient sensitivity to detect cranial pulsation in association with cardiac cycles. By analyzing the magnitude of cranial pulsation, estimates of ICP during space flight are possible.

Ueno, Toshiaki↗

Thermal Imaging of Convecting Opaque Fluids using Ultrasound

An ultrasound technique has been developed to non-intrusively image temperature fields in small-scale systems of opaque fluids undergoing convection. Fluids such as molten metals, semiconductors, and polymers are central to many industrial processes, and are often found in situations where natural convection occurs, or where thermal gradients are otherwise important. However, typical thermal and velocimetric diagnostic techniques rely upon transparency of the fluid and container, or require the addition of seed particles, or require mounting probes inside the fluid, all of which either fail altogether in opaque fluids, or necessitate significant invasion of the flow and/or modification of the walls of the container to allow access to the fluid. The idea behind our work is to use the temperature dependence of sound velocity, and the ease of propagation of ultrasound through fluids and solids, to probe the thermal fields of convecting opaque fluids non-intrusively and without the use of seed particles. The technique involves the timing of the return echoes from ultrasound pulses, a variation on an approach used previously in large-scale systems.

Xu, Hongzhou↗

Ultrasound in space

Physiology of the human body in space has been a major concern for space-faring nations since the beginning of the space era. Ultrasound (US) is one of the most cost effective and versatile forms of medical imaging. As such, its use in characterizing microgravity-induced changes in physiology is being realized. In addition to the use of US in related ground-based studies, equipment has also been modified to fly in space. This involves alteration to handle the stresses of launch and different power and cooling requirements. Study protocols also have been altered to accommodate the microgravity environment. Ultrasound studies to date have shown a pattern of adaptation to microgravity that includes changes in cardiac chamber sizes and vertebral spacing. Ultrasound has been and will continue to be an important component in the investigation of physiological and, possibly, pathologic changes occurring in space or as a result of spaceflight.

Review, Tutorial↗

Validation of On-Orbit Methodology for the Assessment of Cardiac Function and Changes in the Circulating Volume Using Ultrasound and Braslet-M Occlusion Cuffs

The objective of this joint U.S. - Russian project was the development and validation of an in-flight methodology to assess a number of cardiac and vascular parameters associated with circulating volume and its manipulation in long-duration space flight. Responses to modified Valsalva and Mueller maneuvers were measured by cardiac and vascular ultrasound (US) before, during, and after temporary volume reduction by means of Braslet-M thigh occlusion cuffs (Russia). Materials and Methods: The study protocol was conducted in 14 sessions on 9 ISS crewmembers, with an average exposure to microgravity of 122 days. Baseline cardiovascular measurements were taken by echocardiography in multiple modes (including tissue Doppler of both ventricles) and femoral and jugular vein imaging on the International Space Station (ISS). The Braslet devices were then applied and measurements were repeated after >10 minutes. The cuffs were then released and the hemodynamic recovery process was monitored. Modified Valsalva and Mueller maneuvers were used throughout the protocol. All US data were acquired by the HDI-5000 ultrasound system aboard the ISS (ATL/Philips, USA) during remotely guided sessions. The study protocol, including the use of Braslet-M for this purpose, was approved by the ISS Human Research Multilateral Review Board (HRMRB). Results: The effects of fluid sequestration on a number of echocardiographic and vascular parameters were readily detectable by in-flight US, as were responses to respiratory maneuvers. The overall volume status assessment methodology appears to be valid and practical, with a decrease in left heart lateral E (tissue Doppler) as one of the most reliable measures. Increase in the femoral vein cross-sectional areas was consistently observed with Braslet application. Other significant differences and trends within the extensive cardiovascular data were also observed. (Decreased - RV and LV preload indices, Cardiac Output, LV E all maneuvers, LV Stroke Volume). Conclusions: This Study: 1) Addressed specific aspects of operational space medicine and space physiology, including assessment of circulating volume disturbances 2) Expanded the applications of diagnostic ultrasound imaging and Doppler techniques in microgravity. 3) Used respiratory maneuvers against the background of acute circulating volume manipulations which appear to enhance our ability to noninvasively detect volume-dependency in a number of cardiac and vascular parameters. 4) Determined that Tei index is not clinically changed therefore contractility not altered in the face of reduced preload. 5) Determined that increased Femoral Vein Area indicating blood being sequestered in lower extremities correlates with reduced preload and cardiac output. 6) That Braslet may be the only feasible means of acutely treating high pressure pulmonary edema in reduced gravity environments.

Hamilton, Douglas↗

Balanced Expertise Distribution in Remote Ultrasound Imaging Aboard The International Space Station (ISS)

Astronaut training for ISS operations usually ensures independent performance. With small crew size same crews also conduct all science work onboard. With diverse backgrounds, a good "match" between the existing and required skills can only be anecdotal. Furthermore, full proficiency in most of the complex tasks can be attained only through long training and practice, which may not be justified and may be impossible given the scarcity of training time. To enable a number of operational and science advancements, authors have developed a new approach to expertise distribution in time and among the space and ground personnel. Methods: As part of NASA Operational Ultrasound Project (1998-2003) and the NASA-solicited experiment "Advanced Diagnostic Ultrasound in Microgravity-ADUM" (P.I. -S.D., ongoing), the authors have created a "Balanced Expertise Distribution" approach to perform complex ultrasound imaging tasks on ISS for both operational and science use. The four components of expertise are a) any pre-existing pertinent expertise; b) limited preflight training c) adaptive onboard proficiency enhancement tools; d) real-time ' guidance from the ground. Throughout the pre-flight training and flight time preceding the experiments, the four components are shaped in a dynamic fashion to meet in an optimum combination during the experiment sessions. Results: Procedure validation sessions and feasibility studies have given encouraging results. While several successful real-time remote guidance sessions have been conducted on ISS, Expedition 8 is the first to use an "on-orbit proficiency enhancement" tool. Conclusions: In spite of severely limited training time, daring peer-reviewed research and operational enhancements are feasible through a balanced distribution of expertise in time, as well as among the crewmembers and ground personnel. This approach shows great promise for biomedical research, but may be applicable for other areas of micro gravity-based science

Sargsyan, Ashot↗

Exploratory Analysis of Carbon Dioxide Levels and Ultrasound Measures of the Eye During ISS Missions

Carbon dioxide (CO2) levels on ISS have typically averaged 2.3 to 5.3mm Hg, with large fluctuations occurring over periods of hours and days. CO2 has effects on cerebral vascular tone, resulting in vasodilation and alteration of cerebral blood flow(CBF). Increased CBF leads to elevated intracranial pressure(ICP), which is a factor leading to visual disturbance, headaches, and other central nervous system symptoms. Ultrasound of the optic nerve provides a surrogate measurement of ICP. Inflight ultrasounds were implemented as an enhanced screening tool for the Visual Impairment/Intracranial Pressure (VIIP) Syndrome. This analysis examines the relationships between ambient CO2 levels on ISS and ultrasound measures of the eye in an effort to understand how CO2 may be associated with VIIP and to inform future analysis of inflight VIIP data. Results as shown in Figure2, there was a large timeframe where CO2 readings were removed due to sensor fault errors(see Limitations), from June 2011 to January 2012. After extensive cleaning of the CO2 data, metrics for all of the data were calculated (Table2). Preliminary analyses showed possible associations between variability measures of CO2 and AP diameter (Figure3),and average CO2 exposure and ONSD(Figure4). Adjustments for multiple comparisons were not made due to the exploratory nature of the analysis.

Schaefer, C.↗