Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ultrasonic Mixing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Transesterification of waste vegetable oil under pulse sonication using ethanol, methanol and ethanol–methanol mixtures

Highlights: • Pulse sonication effect on transesterification of waste vegetable oil was studied. • Effects of ethanol, methanol, and alcohol mixtures on FAMEs yield were evaluated. • Effect of ultrasonic intensity, power density, and its output rates were evaluated. • Alcohol mixtures resulted in higher biodiesel yields due to better solubility. - Abstract: This study reports on the effects of direct pulse sonication and the type of alcohol (methanol and ethanol) on the transesterification reaction of waste vegetable oil without any external heating or mechanical mixing. Biodiesel yields and optimum process conditions for the transesterification reaction involving ethanol, methanol, and ethanol–methanol mixtures were evaluated. The effects of ultrasonic power densities (by varying sample volumes), power output rates (in W), and ultrasonic intensities (by varying the reactor size) were studied for transesterification reaction with ethanol, methanol and ethanol–methanol (50%-50%) mixtures. The optimum process conditions for ethanol or methanol based transesterification reaction of waste vegetable oil were determined as: 9:1 alcohol to oil ratio, 1% wt. catalyst amount, 1–2 min reaction time at a power output rate between 75 and 150 W. It was shown that the transesterification reactions using ethanol–methanol mixtures resulted in biodiesel yields as high as >99% at lower power density and ultrasound intensity when compared to ethanol or methanol based transesterification reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nonlinear ultrasonic scanning to detect material defects

A method and system are provided to detect defects in a material. Waves of known frequency(ies) are mixed at an interaction zone in the material. As a result, at least one of a difference wave and a sum wave are generated in the interaction zone. The difference wave occurs at a difference frequency and the sum wave occurs at a sum frequency. The amplitude of at least one nonlinear signal based on the sum and/or difference waves is then measured. The nonlinear signal is defined as the amplitude of one of the difference wave and sum wave relative to the product of the amplitude of the surface waves. The amplitude of the nonlinear signal is an indication of defects (e.g., dislocation dipole density) in the interaction zone.

Yost, William T.↗

Processing and structural properties of random oriented lead lanthanum zirconate titanate thin films

Highlights: • Pyrochlore phase crystallizes near the bottom film-electrode interface. • PLZT films show a non-uniform microstrain and crystallite size in depth profile. • Complex grainy structure leads to different elastic modulus at the nanoscale. - Abstract: Polycrystalline lead lanthanum zirconate titanate (PLZT) thin films have been prepared by a polymeric chemical route to understand the mechanisms of phase transformations and map the microstructure and elastic properties at the nanoscale in these films. X-ray diffraction, atomic force microscopy (AFM) and ultrasonic force microscopy (UFM) have been used as investigative tools. On one side, PLZT films with mixed-phase show that the pyrochlore phase crystallizes predominantly in the bottom film-electrode interface while a pure perovskite phase crystallizes in top film surface. On the contrary, pyrochlore-free PLZT films show a non-uniform microstrain and crystallite size along the film thickness with a heterogeneous complex grainy structure leading to different elastic properties at nanoscale.

36 MATERIALS SCIENCE↗

Basic and Applied Materials Science Research Efforts at MSFC Germane to NASA Goals

Presently, a number of investigations are ongoing that blend basic research with engineering applications in support of NASA goals. These include (1) "Pore Formation and Mobility (PFMI) " An ISS Glovebox Investigation" NASA Selected Project - 400-34-3D; (2) "Interactions Between Rotating Bodies" Center Director's Discretionary Fund (CDDF) Project - 279-62-00-16; (3) "Molybdenum - Rhenium (Mo-Re) Alloys for Nuclear Fuel Containment" TD Collaboration - 800-11-02; (4) "Fabrication of Alumina - Metal Composites for Propulsion Components" ED Collaboration - 090-50-10; (5) "Radiation Shielding for Deep-Space Missions" SD Effort; (6) "Other Research". In brief, "Pore Formation and Mobility" is an experiment to be conducted in the ISS Microgravity Science Glovebox that will systematically investigate the development, movement, and interactions of bubbles (porosity) during the controlled directional solidification of a transparent material. In addition to promoting our general knowledge of porosity physics, this work will serve as a guide to future ISS experiments utilizing metal alloys. "Interactions Between Rotating Bodies" is a CDDF sponsored project that is critically examining, through theory and experiment, claims of "new" physics relating to gravity modification and electric field effects. "Molybdenum - Rhenium Alloys for Nuclear Fuel Containment" is a TD collaboration in support of nuclear propulsion. Mo-Re alloys are being evaluated and developed for nuclear fuel containment. "Fabrication of Alumina - Metal Composites for Propulsion Components" is an ED collaboration with the intent of increasing strength and decreasing weight of metal engine components through the incorporation of nanometer-sized alumina fibers. "Radiation Shielding for Deep-Space Missions" is an SD effort aimed at minimizing the health risk from radiation to human space voyagers; work to date has been primarily programmatic but experiments to develop hydrogen-rich materials for shielding are planned. "Other Research" includes: BUNDLE (Bridgman Unidirectional Dendrite in a Liquid Experiment) activities (primarily crucible development), vibrational float-zone processing (with Vanderbilt University), use of ultrasonics in materials processing (with UAH), rotational effects on microstructural development, and application of magnetic fields for mixing.

Source record↗

Experimental and CFD Studies of Coolant Flow Mixing within Scaled Models of the Upper and Lower Plenums of NGNP Gas-Cooled Reactors

A 1/16th scaled VHTR experimental model was constructed and the preliminary test was performed in this study. To produce benchmark data for CFD validation in the future, the facility was first run at partial operation with five pipes being heated. PIV was performed to extract the vector velocity field for three adjacent naturally convective jets at statistically steady state. A small recirculation zone was found between the pipes, and the jets entered the merging zone at 3 cm from the pipe outlet but diverged as the flow approached the top of the test geometry. Turbulence analysis shows the turbulence intensity peaked at 41-45% as the jets mixed. A sensitivity analysis confirmed that 1000 frames were sufficient to measure statistically steady state. The results were then validated by extracting the flow rate from the PIV jet velocity profile, and comparing it with an analytic flow rate and ultrasonic flowmeter; all flow rates lie within the uncertainty of the other two methods for Tests 1 and 2. This test facility can be used for further analysis of naturally convective mixing, and eventually produce benchmark data for CFD validation for the VHTR during a PCC or DCC accident scenario. Next, a PTV study of 3000 images (1500 image pairs) were used to quantify the velocity field in the upper plenum. A sensitivity analysis confirmed that 1500 frames were sufficient to precisely estimate the flow. Subsequently, three (3, 9, and 15 cm) Y-lines from the pipe output were extracted to consider the output differences between 50 to 1500 frames. The average velocity field and standard deviation error that accrued in the three different tests were calculated to assess repeatability. The error was varied, from 1 to 14%, depending on Y-elevation. The error decreased as the flow moved farther from the output pipe. In addition, turbulent intensity was calculated and found to be high near the output. Reynolds stresses and turbulent intensity were used to validate the data by comparing it with benchmark data. The experimental data gave the same pattern as the benchmark data. A turbulent single buoyant jet study was performed for the case of LOFC in the upper plenum of scaled VHTR. Time-averaged profiles show that 3,000 frames of images were sufficient for the study up to second-order statistics. Self-similarity is an important feature of jets since the behavior of jets is independent of Reynolds number and a sole function of geometry. Self-similarity profiles were well observed in the axial velocity and velocity magnitude profile regardless of z/D where the radial velocity did not show any similarity pattern. The normal components of Reynolds stresses have self-similarity within the expected range. The study shows that large vortices were observed close to the dome wall, indicating that the geometry of the VHTR has a significant impact on its safety and performance. Near the dome surface, large vortices were shown to inhibit the flows, resulting in reduced axial jet velocity. The vortices that develop subsequently reduce the Reynolds stresses that develop and the impact on the integrity of the VHTR upper plenum surface. Multiple jets study, including two, three and five jets, were investigated.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Energy efficiency in industrial drying: A hybrid ultrasonic system with a novel dynamic optimization framework

Drying processes are among the most energy-consuming operations in industrial and manufacturing settings, demanding strategic selection, design, and control for enhanced efficiency. Advancing drying technologies is critical for improving sustainability, lowering energy use, reducing carbon emissions, and minimizing waste. This study explores two innovative strategies aimed at transforming drying processes into sustainable, low-carbon systems by reducing energy consumption, minimizing waste, and maintaining a strong emphasis on preserving product quality. The first strategy showcases a sub-pilot scale hybrid ultrasonic-convective dryer for agrifood products. This technology, powered by electricity (process electrification), integrates non-thermal ultrasonic dehydration with convective heating and is presented as a sustainable and energy-efficient solution that enhances eco-friendly practices. The second strategy involves introducing and implementing a novel, multiobjective, mixed integer dynamic optimization technique to determine the optimal time-dependent process parameter values for the drying operation. This optimization technique yields operating conditions that are piecewise constant in time aiming to maximize the energy efficiency of the hybrid ultrasonic-convective dryer while ensuring strict adherence to product quality constraints. By adopting the hybrid ultrasonic-convective dryer, a notable 35% improvement in energy efficiency was achieved compared to conventional hot-air drying systems for drying apple slices. The proposed optimization framework further enhanced energy efficiency by nearly 14% over the most efficient process on the identical testbed, under static operating conditions. The reported enhancements have been experimentally validated. Regarding drying time (thereby improving production yield), the developed hybrid ultrasonic-convective dryer demonstrates as much as a 41% reduction in total processing time, which is further optimized by an additional 10% using our proposed optimization framework. The research outcomes have profound implications for the design and operation of drying systems, encompassing crucial aspects such as process electrification, cost-effectiveness, energy savings, time efficiency, product yield, product quality, and process automation.

Dynamic optimization↗

Dielectric Properties of PVDF/PZT

Poly(vinylidene fluoride)/ lead zirconate titanate nanocomposite (PVDF/PZT-NPs) were successfully prepared by mixing fine Pb(Zr{sub 0.52}, Ti{sub 0.48})O{sub 3} nanoparticles (PZT-NPs) into a PVDF solution under ultrasonication. The mixture was spin coated onto glass substrate and then annealed at 80 deg. C. X-ray diffraction (XRD), transmission electron microscopy (TEM), and scanning electron microscopy (SEM) were used to characterize the structure and properties of the obtained thin-film nanocomposites. The nanocomposites exhibited good dielectric stability over a wide frequency range.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

An effective-medium model for P-wave velocities of saturated, unconsolidated saline permafrost

To better understand the relationship between P-wave velocities and ice content in saturated, unconsolidated saline permafrost, we constructed an effective-medium model based upon ultrasonic P-wave data that were obtained from earlier laboratory studies. The model uses a two-end-member mixing approach in which an ice-filled, fully frozen end member and a water-filled, fully unfrozen end member are mixed together to form the effective medium of partially frozen sediments. This mixing approach has two key advantages: (1) It does not require parameter tuning of the mixing ratios, and (2) it inherently assumes mixed pore-scale distributions of ice that consist of frame-strengthening (i.e., cementing and/or loadbearing) ice and pore-filling ice. The model-predicted P-wave velocities agree well with our laboratory data, demonstrating the effectiveness of the model for quantitatively inferring ice content from P-wave velocities. The modeling workflow is simple and is largely free of calibration parameters -attributes that ease its application in interpreting field data sets.

54 ENVIRONMENTAL SCIENCES↗

Synthesis of strontium substituted barium titanate nanoparticles by mechanical alloying and high power ultrasonication destruction

This paper reports the particle and crystallite size characterizations of mechanically alloyed Ba{sub (1-x)}Sr{sub x}TiO{sub 3} (BST) with x = 0.3 and 0.7 prepared with the assistance of a high-power sonicator. Analytical grade BaCO{sub 3}, TiO{sub 2} and SrCO{sub 3} precursors with a purity of greater than 99 wt.% were mixed and milled using a planetary ball mill to a powder weight ratio of 10:1. Powders obtained after 20 hours of milling time were then sintered at 1200°C for 4 hours to form crystalline powders.These powders were further treated ultrasonically under a fixed 6.7 gr/l particle concentration in demineralized water for 1, 3, 5, 7 hours and a fixed ultrasonic irradiation time of 1 hour to the dispersion of 6.7; 20; 33.3 gr/l concentrations. As to the results of crystallite size characterization, it is demonstrated that the mean crystallite size of BST with x = 0.3 and 0.7 undergo a slight change after the first 1 hour irradiation time and then remain almost unchanged. This was in contrary to the particle size in which the mean particle size of BST with x = 0.3 increased from 765 nm to 1405 nm after 7 hours irradiation time, while that of x = 0.7 increased from 505 nm to 1298 nm after 3 hours and then reduced back to the initial size after 7 hours ultra sonication time. The increase in particle size was due to large of cohesive forces among fine particles. It is also demonstrated that the concentration of particles in a dispersion with anionic surfactant do not effective to reduce the particle sizes ultrasonically. Nanoparticles with the mean size respectively 40 and 10 times larger than their respective crystallite size were successfully obtained respectively in x = 0.3 and x = 0.7.

36 MATERIALS SCIENCE↗

Investigating Using Oscillating Jets for Fluid Mixing

Scaled mixing experiments were conducted to evaluate maintaining mobilized particles in a uniform suspension (the condition of concentration uniformity) using jet pumps to mix the suspension. The study experimentally evaluated uniformity in a 1/12-scale experiment varying the Reynolds number, Froude number, and gravitational settling parameter space. The initial matrix specified only tests at 100% U0D0 and 25% U0D0. After initial tests were conducted with small diameter, low viscosity simulant this matrix was revised to allow evaluation of a broader range of U0D0. The revised matrix included a full factorial test between 100% and 50% U0D0 and two half-factorial tests at 75% and 25% U0D0. Adding points at 75% U0D0 and 50% U0D0 allowed evaluation of curvature. Eliminating points at 25% U0D0 decreased the testing time by several weeks. Test conditions were achieved by varying the simulant viscosity, the mean particle size (dp), and the jet nozzle exit velocity (U0). Concentration measurements at sampling locations throughout the tank were used to assess the degree of uniformity achieved during each test. Concentration data was obtained using a real time ultrasonic attenuation probe and discrete batch samples. The undissolved solids concentration at these locations was analyzed to determine whether the tank contents were uniform (< ±10% variation about mean) or nonuniform (> ±10% variation about mean) in concentration. Concentration inhomogeneity was modeled as a function of dimensionless groups.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Flocculation and Sedimentation in Suspensions Using Ultrasonic Wave Reflection

This work was undertaken to help understand and interpret the ultrasonic wave reflection (UWR) response of portland cement paste as it transforms from a fluid-like suspension to a solid in the first hours after mixing. A high impact polystyrene buffer (delay line) was used to measure small changes in the P-wave and S-wave reflection coefficients. Two materials were studied: a non-hydrating colloidal alumina suspension whose microstructure was manipulated between dispersed and flocculated states by adjusting the pH, and a coarse silica suspension that readily sedimented. The S-wave reflection coefficient clearly distinguished between dispersed and flocculated states. Sedimentation of particles in dispersed suspensions was distinguished using the P-wave reflection coefficient. Based on these findings, the observed P- and S-wave responses from hydrating portland cement paste are interpreted in terms of flocculation and sedimentation processes.

36 MATERIALS SCIENCE↗

SCM Paste Samples Exposed To Aggressive Solutions. Cementitious Barriers Partnership

This report summarizes experimental work performed by SIMCO Technologies Inc. (SIMCO) as part of the Cementitious Barriers Partnership (CBP) project. The test series followed an experimental program dedicated to the study of ordinary Portland cement (OPC) hydrated cement pastes exposed to aggressive solutions. In the present study, the scope is extended to hydrated cement pastes incorporating supplementary cementitious materials (SCM) such as fly ash and ground granulated blast furnace slag (GGBFS). Also, the range of aggressive contact solutions was expanded. The experimental program aimed at testing aggressive contact solutions that more closely mimic the chemical composition of saltstone pore solution. Five different solutions, some of which incorporated high levels of carbonate and nitrate, were placed in contact with four different hydrated cement paste mixes. In all solutions, 150 mmol/L of SO 4 2– (14 400 ppm) were present. The solutions included different pH conditions and different sodium content. Two paste mixes were equivalent to Vault 1/4 and Vault 2 concrete mixes used at SRS in storage structures. Two additional paste mixes, cast at the same water-to-cement ratio and using the same cements but without SCMs, were also tested. The damage evolution in samples was monitored using ultrasonic pulse velocity (UPV) and mass measurements. After three and twelve months of exposure conditions, samples were taken out of solution containers and analyzed to perform migration tests and porosity measurements. Globally, results were in line with the previous study and confirmed that high pH may limit the formation of some deleterious phases like gypsum. In this case, ettringite may form but is not necessarily associated with damage. However, the high concentration of sodium may be associated with the formation of an AFm-like mineral called U-phase. The most significant evidences of damage were all associated with the Vault 2 paste analog. This material proved very sensitive to high pH. All measurement techniques used to monitor and evaluate damage to samples indicated significant alterations to this mix when immersed in contact solutions containing sodium hydroxide. It was hypothesized that the low cement content, combined with high silica content coming from silica fume, fly ash and GGBFS led to the presence unreacted silica. It is possible that the pozzolanic reaction of these SCMs could not be activated due to the low alkali content, a direct consequence of low cement content. In this scenario, the material end up having a lot of silica available to react upon contact with sodium hydroxide, possibly forming a gel that may be similar to the gel formed in alkali-silica reactions. This scenario needs further experimental confirmation, but it may well explain the poor behavior of mix PV2 in presence of NaOH.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Ultrasonic Leak Detection System

A system for detecting ultrasonic vibrations. such as those generated by a small leak in a pressurized container. vessel. pipe. or the like. comprises an ultrasonic transducer assembly and a processing circuit for converting transducer signals into an audio frequency range signal. The audio frequency range signal can be used to drive a pair of headphones worn by an operator. A diode rectifier based mixing circuit provides a simple, inexpensive way to mix the transducer signal with a square wave signal generated by an oscillator, and thereby generate the audio frequency signal. The sensitivity of the system is greatly increased through proper selection and matching of the system components. and the use of noise rejection filters and elements. In addition, a parabolic collecting horn is preferably employed which is mounted on the transducer assembly housing. The collecting horn increases sensitivity of the system by amplifying the received signals. and provides directionality which facilitates easier location of an ultrasonic vibration source.

Youngquist, Robert C.↗

Physical Characterization of Solid-Liquid Slurries at High Weight Fractions Using Optical and Ultrasonic Methods, Final Report

Remediation of highly radioactive waste is a major technical and programmatic challenge for the DOE. Rapid, on-line physical characterization of highly concentrated slurries is required for the safe and efficient remediation of 90 million gallons of high level radioactive waste (HLW), sodium bearing waste, and mixed waste. The research presented here, describes a collaborative effort between Pacific Northwest National Laboratory (PNNL) and the University of Washington to directly address the need for rapid on-line characterization of the physical properties of HLW slurries during all phases of the remediation process, from in-tank characterization of sediments to monitoring of the concentration, particle size, and degree of agglomeration and gelation of slurries during transport. Near-surface characterization of the slurry flow in the particle size range from nanometer to micrometer is examined using optical low coherence reflectometry. Volumetric characterization at depths in the slurry flow, up to several centimeters in the particle size range from the micrometer to millimeter, is realized by utilizing ultrasonic backscatter and diffuses fields. One of the strengths, the teaming up of significant talents in both experimental and theoretical optics (University of Washington) and in ultrasonics [Pacific Northwest National Laboratory (PNNL)] provides a synergistic approach to integrate these complimentary techniques. One of the benefits of this combined approach is the physical characterization of HLW over a concentration and particle size range that is broader than can be achieved with today’s technology. This will avoid a costly increase in waste stream volume due to excess dilution, and will lessen chance of plugging pipes that could shut down expensive processing lines.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental and Numerical Investigation of PZT Response in Composite Structures with Variable Degradation Levels

Commercial aerospace vehicles have been increasingly demanding to withstand harsh conditions with low-weight material, i.e., composites. Unfortunately, low-velocity impacts strongly affect their performance. Structural health monitoring with permanently attached sensors allows achieving cost-effective maintenance and tearing down knockdown factors. However, the degradation of transducers adopted for online detection of damage negatively affects the diagnosis. That deterioration is addressed in this work with the electromechanical impedance approach employed at relatively low ultrasonic frequencies. Several degradation conditions are investigated with experimental and numerical simulations. The results demonstrate how the self-diagnosis approach detects pure sensor failures without any structural dependence. However, self-detection of the mixed mode of failures is challenging due to the opposite effect that different types of failure return. Numerical simulations provide a spectral response in compliance with measurements. On top of that, numerical results demonstrate that the combination of different types of damage may induce missed detection. That is where a multi-parameter self-diagnosis approach may further improve the overall monitoring system.

36 MATERIALS SCIENCE↗

A Comparison of Modeling Strategies for Additively Manufactured HFIR Control Elements

The High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory is a flux-trap type research reactor that is used for a range of research applications, including neutron scattering experiments, materials irradiation tests, and isotope production. The HFIR core comprises several concentric cylindrical regions; starting from the core centerline and moving radially outwards, these are the flux trap target (FTT) region, the inner and outer fuel elements (IFE and OFE), the inner and outer control elements (ICE and OCE), and the reflector region. The control elements (CEs) are axially zoned into regions of differing absorption strength: the white regions contain only structural aluminum and do not significantly contribute to reactivity control; the gray regions contain tantalum as the primary absorber with a concentration of 38% by volume, and the black regions contain europia (Eu{sub 2}O{sub 3}) as the primary absorber with a concentration of 31% by volume. During operation, the CEs are withdrawn symmetrically in opposite directions from the core to remove the neutron absorbers from the core and maintain criticality. The current approach to fabrication of the HFIR CEs is tedious, outdated, and expensive. In an effort to improve the operational economics of HFIR and to demonstrate the feasibility of advanced manufacturing techniques for production of nuclear reactor components, novel methods for production of neutron-poison bearing aluminum structures have been initiated at ORNL. For this application, the ultrasonic additive manufacturing (UAM) process involves the use of 3D printing technology to construct small cylindrical compacts (0.559 cm in diameter and 0.171 cm in height) of aluminum mixed with neutron-absorbing material. The compacts contain 60% poison (Ta or Eu{sub 2}O{sub 3}) by volume. These compacts are then embedded into an aluminum matrix before formation into the cylindrical shape appropriate for use in HFIR. The CEs produced in this process therefore contain discrete regions of absorbing material, in contrast to the traditional design with homogeneously distributed absorbers. It is therefore of interest to investigate how the HFIR core behavior with discrete CEs differs from the case with homogeneous CEs with respect to some key reactor physics parameters. The primary objective of this study is to compare modeling strategies for the discrete CE design and examine differences in the core physics between the discrete and homogeneous CE designs as predicted by each model. Lessons learned from this investigation may then be used to inform the design process in future endeavors. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Quantitative Ultrasound Characterization of Cancer Radiotherapy Effects In Vitro

Purpose: Currently, no routinely used imaging modality is available to assess tumor responses to cancer treatment within hours to days after radiotherapy. In this study, we demonstrate the preclinical application of quantitative ultrasound methods to characterize the cellular responses to cancer radiotherapy in vitro. Methods and Materials: Three different cell lines were exposed to radiation doses of 2-8 Gy. Data were collected with an ultrasound scanner using frequencies of 10-30 MHz. As indicators of response, ultrasound integrated backscatter and spectral slope were determined from the cell samples. These parameters were corrected for ultrasonic attenuation by measuring the attenuation coefficient. Results: A significant increase in the ultrasound integrated backscatter of 4-7 dB (p < 0.001) was found for radiation-treated cells compared with viable cells at all radiation doses. The spectral slopes decreased in the cell samples that predominantly underwent mitotic arrest/catastrophe after radiotherapy, consistent with an increase in cell size. In contrast, the spectral slopes did not change significantly in the cell samples that underwent a mix of cell death (apoptosis and mitotic arrest), with no significant change in average cell size. Conclusion: The changes in ultrasound integrated backscatter and spectral slope were direct consequences of cell and nuclear morphologic changes associated with cell death. The results indicate that this combination of quantitative ultrasonic parameters has the potential to assess the cell responses to radiation, differentiate between different types of cell death, and provide a preclinical framework to monitor tumor responses in vivo.

62 RADIOLOGY AND NUCLEAR MEDICINE↗