Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “UPS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Investigating Cu-Site Doped Cu–Sb–S Nanoparticles Using Photoelectron and Electron Paramagnetic Resonance Spectroscopy

Tetrahedrite (Cu 12 Sb 4 S 13 ) and famatinite (Cu 3 SbS 4 ) are good candidates for green energy applications because they possess promising thermoelectric and photovoltaic properties as well as contain earth-abundant and nontoxic constituents. Herein, X-ray photoelectron spectroscopy (XPS), ultraviolet photoelectron spectroscopy (UPS), and electron paramagnetic resonance spectroscopy (EPR) methods examined inherent electronic properties and interatomic magnetic interactions of Cu-site doped tetrahedrite and famatinite nanomaterials. An energy-efficient modified polyol method was utilized for the synthesis of tetrahedrite and famatinite nanoparticles doped on the Cu-site with Zn, Fe, Ni, Mn, and Co. This is the first parallel study of tetrahedrite and famatinite nanomaterials with XPS, UPS, and EPR methods alongside a systematic analysis of dopant-dependent effects on the electronic structure and magnetic interactions for each material. XPS showed that the Cu and Sb species in tetrahedrite and famatinite possess different oxidation states, while UPS characterization reveals larger dopant-dependent shifts in the work function for tetrahedrite nanoparticles (4.21 to 4.79 eV) than for famatinite nanoparticles (4.57 to 4.77 eV). Finally, all famatinite nanoparticles display an EPR signal, indicating trace amounts of paramagnetic Cu(II) present below the detection limit of XPS. For tetrahedrite, EPR signatures were observed only for the Zn-doped and Mn-doped nanoparticles, suggesting signal broadening from Cu–Cu spin exchange or spin–lattice relaxation. This study demonstrates the complementary nature of XPS and EPR techniques for studying the oxidation states of metals in solid-state nanomaterials. Comparing the electronic and magnetic properties of tetrahedrite and famatinite while studying the impact of dopant incorporation will guide future endeavors in designing sustainable, high-performance materials for renewable energy applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An IRE1-proteasome system signalling cohort controls cell fate determination in unresolved proteotoxic stress of the plant endoplasmic reticulum

Excessive accumulation of misfolded proteins in the endoplasmic reticulum (ER) causes ER stress, which is an underlying cause of major crop losses and devastating human conditions. Here, ER proteostasis surveillance is mediated by the conserved master regulator of the unfolded protein response (UPR), Inositol Requiring Enzyme 1 (IRE1), which determines cell fate by controlling pro-life and pro-death outcomes through as yet largely unknown mechanisms. Here we report that Arabidopsis IRE1 determines cell fate in ER stress by balancing the ubiquitin–proteasome system (UPS) and UPR through the plant-unique E3 ligase, PHOSPHATASE TYPE 2CA (PP2CA)-INTERACTING RING FINGER PROTEIN 1 (PIR1). Indeed, PIR1 loss leads to suppression of pro-death UPS and the lethal phenotype of an IRE1 loss-of-function mutant in unresolved ER stress in addition to activating pro-survival UPR. Specifically, in ER stress, PIR1 loss stabilizes ABI5, a basic leucine zipper (bZIP) transcription factor, that directly activates expression of the critical UPR regulator gene, bZIP60, triggering transcriptional cascades enhancing pro-survival UPR. Collectively, our results identify new cell fate effectors in plant ER stress by showing that IRE1’s coordination of cell death and survival hinges on PIR1, a key pro-death component of the UPS, which controls ABI5, a pro-survival transcriptional activator of bZIP60.

59 BASIC BIOLOGICAL SCIENCES↗

Harnessing Virtual Power Plants Reliably: Enabling tools for increased observability, controllability, operation, and aggregation of distributed energy resources

Harnessing virtual power plants enhances the integration of distributed energy resources into utility grids for a sustainable energy future. Virtual power plants (VPPs) aggregate DERs to enhance resource adequacy and reduce emissions. U.S. utilities are exploring various technologies to manage DERs effectively. FERC Order 2222 allows DERs to participate in both wholesale and retail markets. Enhancing observability and controllability of behind-the-meter (BTM) DERs is essential for reliable grid operations. A hierarchical control architecture can improve coordination among residential energy resources. Field tests showed nearly 20% energy savings and 30% peak power reduction during grid events. Effective management of DERs requires enhanced situational awareness to prevent grid congestion. Integrating DER management systems (DERMS) with existing planning tools can improve operational security. Near-real-time grid models can validate optimal resource set points against resource uncertainty. Traditional uninterruptible power supplies (UPS) can be upgraded to support grid services and become part of VPPs. Upgrading UPS systems can reduce costs by 75% and unlock significant battery capacity. New battery management systems and grid-aware controllers are essential for optimizing UPS performance. Continued research and development are necessary to address challenges in integrating DERs into utility grids. Encouraging customer participation in pilot programs is vital for the evolution of VPPs. Here, the shift towards price-responsive DERs and VPPs is expected to enhance energy distribution efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Uninterruptible Power Supply Systems, UTrain Course 58423 [Slides]

Identify the principles of operation of uninterruptible power supply (UPS) systems, focusing on double conversion and offline/standby/backup types. The traditional UPS is now referred to as a “double conversion” UPS. The AC input power is rectified into DC. The DC feeds an inverter which provides the AC output. The DC bus is also connected to batteries. It is called double conversion because the first conversion is from AC to DC and the second conversion is from DC to AC. The inverter creates the output waveform to match the bypass input. Because of this, the static bypass switch may be switched between inverter and bypass seamlessly.

42 ENGINEERING↗

Analysis of 26S Proteasome Activity across Arabidopsis Tissues

Plants utilize the ubiquitin proteasome system (UPS) to orchestrate numerous essential cellular processes, including the rapid responses required to cope with abiotic and biotic stresses. The 26S proteasome serves as the central catalytic component of the UPS that allows for the proteolytic degradation of ubiquitin-conjugated proteins in a highly specific manner. Despite the increasing number of studies employing cell-free degradation assays to dissect the pathways and target substrates of the UPS, the precise extraction methods of highly potent tissues remain unexplored. Here, we utilize a fluorogenic reporting assay using two extraction methods to survey proteasomal activity in different Arabidopsis thaliana tissues. This study provides new insights into the enrichment of activity and varied presence of proteasomes in specific plant tissues.

26S proteasome↗

The 1979 Southeastern Virginia Urban Plume Study. Volume 1: Description of experiments and selected aircraft data

The Southeastern Virginia Urban Plume Study (SEV-UPS) utilizes remote sensors and satellite platforms to monitor the Earth's environment and resources. SEV-UPS focuses on the application of specific remote sensors to the monitoring and study of specific air quality problems. The 1979 SEV-UPS field program was conducted with specific objectives: (1) to provide correlative data to evaluate the Laser Absorption spectrometer ozone remote sensors; (2) to demonstrate the utility of the sensor for the study of urban ozone problems; (3) to provide additional insights into air quality phenomena occuring in Southeastern Virginia; and (4) to compare measurement results of various in situ measurement platforms. The field program included monitoring from 12 surface stations, 4 aircraft, 2 tethered balloons, 2 radiosonde release sites, and numerous surface meteorological observation sites. The aircraft monitored 03, NO, NOX, Bscat, temperature, and dewpoint temperature.

Gregory, G. L.↗

Aeroelastic airfoil smart spar

Aircraft wings and rotor-blades are subject to undesirable bending and twisting excursions that arise from unsteady aerodynamic forces during high speed flight, abrupt maneuvers, or hard landings. These bending excursions can range in amplitude from wing-tip flutter to failure. A continuous-filament construction 'smart' laminated composite box-beam spar is described which corrects itself when subject to undesirable bending excursions or flutter. The load-bearing spar is constructed so that any tendency for the wing or rotor-blade to bend from its normal position is met by opposite twisting of the spar to restore the wing to its normal position. Experimental and theoretical characterization of these spars was made to evaluate the torsion-flexure coupling associated with symmetric lay-ups. The materials used were uniweave AS-4 graphite and a matrix comprised of Shell 8132 resin and U-40 hardener. Experimental tests were conducted on five spars to determine spar twist and bend as a function of load for 0, 17, 30, 45 and 60 deg fiber angle lay-ups. Symmetric fiber lay-ups do exhibit torsion-flexure couplings. Predictions of the twist and bend versus load were made for different fiber orientations in laminated spars using a spline function structural analysis. The analytical results were compared with experimental results for validation. Excellent correlation between experimental and analytical values was found.

Greenhalgh, Skott↗

Acoustic Performance of an Advanced Model Turbofan in Three Aeroacoustic Test Facilities

A model advanced turbofan was acoustically tested in the NASA Glenn 9- by 15-Foot-Low-Speed Wind Tunnel (LSWT), and in two other aeroacoustic facilities. The Universal Propulsion Simulator (UPS) fan was designed and manufactured by the General Electric Aircraft Engines (GEAE) Company, and featured active core, as well as bypass, flow paths. The reference test configurations were with the metal, M4, rotor with hardwall and treated bypass flow ducts. The UPS fan was tested within an airflow at a Mach number of 0.20 (limited flow data were also acquired at a Mach number of 0.25) which is representative of aircraft takeoff and approach conditions. Comparisons were made between data acquired within the airflow (9x15 LSWT and German-Dutch Wind Tunnel (DNW)) and outside of a free jet (Boeing Low Speed Aero acoustic Facility (LSAF) and DNW). Sideline data were acquired on an 89-in. (nominal 4 fan diameters) sideline using the same microphone assembly and holder in the 9x15 LSWT and DNW facilities. These data showed good agreement for similar UPS operating conditions and configurations. Distortion of fan spectra tonal content through a free jet shear layer was documented, suggesting that in-flow acoustic measurements are required for comprehensive fan noise diagnostics. However, there was good agreement for overall sound power level (PWL) fan noise measurements made both within and outside of the test facility airflow.

Woodward, Richard P.↗

Exciton Binding Energy in Organic Polymers: Experimental Considerations and Tuning Prospects

Discrepancies in reported values of exciton binding energy (E b ) for organic semiconductors (OSs) necessitate a comprehensive study. Traditionally, E b is defined as the difference between the transport gap (E t ) and the optical gap (E opt ). Here, the E b values of PBnDT‐TAZ polymer variants are determined using two commonly employed methods: a combination of ultraviolet photoemission spectroscopy and low‐energy inverse photoemission spectroscopy (UPS‐LEIPS) and solid‐state cyclic voltammetry (CV). E b values obtained by UPS‐LEIPS show low dispersion and no clear correlation with the polymer structure and thedielectric properties. In contrast, CV reveals a larger dispersion (200 meV‐1 eV) and an apparent qualitative E b ‐molecular structure correlation, as the lowest E b values are observed for oligo‐ethylene glycol side chains. This discrepancy is discussed by examining the implications of the traditional definition of E b . Additionally, the impact of both intrinsic and extrinsic factors contributing to the derived experimental values of E t is discussed. The differences in intrinsic and extrinsic factors highlight the context‐dependent nature of measurement when drawing global conclusions. Notably, the observed E b trend derived from CV is not intrinsic to the pure materials but likely linked to electrolyte swelling and associated changes in dielectric environment, suggesting that high‐efficiency single‐material organic photovoltaics with low E b may be possible via high dielectric materials.

36 MATERIALS SCIENCE↗

Modelling and computational improvements to the simulation of single vector-boson plus jet processes for the ATLAS experiment

This paper presents updated Monte Carlo configurations used to model the production of single electroweak vector bosons (W, Z/γ$^{∗}$) in association with jets in proton-proton collisions for the ATLAS experiment at the Large Hadron Collider. Improvements pertaining to the electroweak input scheme, parton-shower splitting kernels and scale-setting scheme are shown for multi-jet merged configurations accurate to next-to-leading order in the strong and electroweak couplings. The computational resources required for these set-ups are assessed, and approximations are introduced resulting in a factor three reduction of the per-event CPU time without affecting the physics modelling performance. Continuous statistical enhancement techniques are introduced by ATLAS in order to populate low cross-section regions of phase space and are shown to match or exceed the generated effective luminosity. This, together with the lower per-event CPU time, results in a 50% reduction in the required computing resources compared to a legacy set-up previously used by the ATLAS collaboration. The set-ups described in this paper will be used for future ATLAS analyses and lay the foundation for the next generation of Monte Carlo predictions for single vector-boson plus jets production.[graphic not available: see fulltext]

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multiscale simulation of integrated energy system and electricity market interactions

Accelerating the deep decarbonization of the world's electric grids requires the coordination of complex energy systems and infrastructures across timescales from seconds to decades. Here, we present a new multiscale simulation framework that integrates process- and grid-centric modeling paradigms to better design, operate, and control integrated energy systems (IESs), which combine multiple technologies, in wholesale energy markets. Traditionally, IESs are analyzed with a process-centric paradigm such as levelized cost of electricity (LCOE) or annualized net revenue, ignoring important interactions with electricity markets. This framework explicitly models the complex interactions between an IES's bidding, scheduling, and control decisions and the energy market's clearing and settlement processes, while incorporating operational uncertainties. Through two case studies, we show the importance of understanding and quantifying complex resource-grid interactions. In case study 1, we demonstrate that optimized bidding from one resource shifts the profit distribution for all energy systems in the market. This result suggests new and more flexible IES technologies can disrupt the economics of all market participants, possibly leading to accelerated retirements of less flexible resources. Interestingly, the optimized bidding has little impact on grid-level aggregate statistics, such as total generation costs and renewable penetration rate. While aggregate modeling strategies may remain valid under some IES adoption scenarios for analysis focused on regional outcomes, direct comparisons of IES technologies at specific locations without considering these interactions may lead to misleading or incorrect conclusions. In case study 2, we consider the design and flexible operation of IESs that hybridize conventional generators with energy storage. Through a sensitivity analysis, we find that as the size of the storage system increases, the total number of start-ups for coal- and natural gas-based IESs reduced by 25% and 33.6%, and the total thermal generator ramping (i.e., mileage) reduced by 86.5% and 62.5%, respectively. This shows the primary benefit of storage may not be reduced operational costs (which do not change significantly) but fewer start-ups and less ramping, which may greatly simplify the design, operation, and control of carbon capture systems. The new modeling and optimization capabilities from this work enable the coupling of rigorous, dynamic process models with grid-level production cost models to quantitatively identify the nuanced interdependencies across these vast timescales that must be addressed to realize clean, safe, and secure energy production. Moreover, the proposed general multiscale simulation framework is applicable to all IES technologies and can be easily extended to consider other energy carriers (e.g., hydrogen, ammonia) and energy infrastructures (e.g., natural gas pipelines).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Work function measurements of clean and modified carbon nanospikes

Carbon surfaces incorporating densely packed spikes with nanometer sharpness have shown exceptional electrocatalytic properties attributed to the enhanced electric field from the topography of the spikes. In this article, the composition of nanospike surfaces is identified by x-ray photoelectron spectroscopy (XPS) and their absolute work function determined using ultraviolet photoemission spectroscopy (UPS). Low temperature annealing of as-grown samples above 275 °C is required to produce a clean surface which has a 4.13 eV work function, a half volt lower than that of flat graphite. Treatments that contaminate the spiked surface, including exposure to air, oxidation at elevated temperature, or immersion in water or hydrocarbons, all increase the work function. Processing that blunts the spikes, including exposure to an oxygen plasma, argon sputtering, or high temperature annealing (800 °C) result in a work function close to that of flat graphite. An unusual double onset in the UPS secondary electron intensity is observed on as-grown nanospike samples and is reproduced by absorbing hydrocarbons on the surface. In conclusion, this double onset appears to be unique to carbon substrates and may originate in inelastic scattering of photoelectrons.

36 MATERIALS SCIENCE↗

Spectral Signatures of a Negative Polaron in a Doped Polymer Semiconductor: Energy Levels and Hubbard U Interactions

The modern picture of negative charge carriers on conjugated polymers invokes the formation of a singly occupied (spin-up/spin-down) level within the polymer gap and a corresponding unoccupied level above the polymer conduction band edge. The energy splitting between these sublevels is related to on-site Coulomb interactions between electrons, commonly termed Hubbard U. However, spectral evidence for both sublevels and experimental access to the U value is still missing. Here, in this work, we provide evidence by n-doping the polymer P(NDI 2 OD-T 2 ) with [RhCp*Cp] 2 , [N-DMBI] 2 , and cesium. Changes in the electronic structure after doping are studied with ultraviolet photoelectron and low-energy inverse photoemission spectroscopies (UPS, LEIPES). UPS data show an additional density of states (DOS) in the former empty polymer gap while LEIPES data show an additional DOS above the conduction band edge. These DOS are assigned to the singly occupied and unoccupied sublevels, allowing determination of a U value of ~1 eV.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Unveiling the Role of In Situ Al 2 O 3 Passivation in Molecular-Ink-Processed CuIn(S,Se) 2 Photovoltaics

Here, we report on the optimization of in situ passivation of ink-based CuIn(S,Se) 2 thin-film solar cells via controlled incorporation of Al 2 O 3 in CuIn(S,Se) 2 films by the addition of Al(NO 3 ) 3 to the molecular ink precursor. For this purpose, the Al/(Al + In) (AAI) metal ratio was varied from 0.05 to 0.30. We observe that the efficiency of the cells made of Al 2 O 3 -incorporated CuIn(S,Se) 2 is consistently higher than those without Al 2 O 3 , especially due to an improvement in open-circuit voltage (V OC ) and fill factor (FF), for all tested AAI ratios. With an AAI of 0.05, a maximum efficiency of 11.2% and an average efficiency of 8.5% (measured across 18 cells) was achieved, compared to 8.5% maximum efficiency and 6.5% average efficiency for Al-free CuIn(S,Se) 2 . Furthermore, we find that cells made of Al 2 O 3 -incorporated CuIn(S,Se) 2 with an AAI of 0.2 show a narrow distribution in the photovoltaic performance, indicating higher reproducibility and higher FF. Energy-dispersive X-ray spectroscopy shows that, at AAI = 0.2, Al 2 O 3 is distributed more homogeneously at the surface of the Al 2 O 3 -incorporated CISSe. Capacitance-voltage measurements reveal a reduced defect density by incorporation of Al 2 O 3 , which could be partly responsible for the higher V OC . Furthermore, using detailed surface analysis with various X-ray and electron spectroscopy methods, we derive chemical and electronic structure information from the surface. With ultraviolet photoelectron (UPS) and inverse photoemission spectroscopies (IPES), the electronic band gap of the CuIn(S,Se) 2 thin-film surface is found to increase from 1.22 to 1.88 eV (+-0.12 eV) with Al 2 O 3 incorporation. This is accompanied by a clear reduction of the conduction band spike at the CdS/CISSe interface due to Al 2 O 3 addition, as derived by both UPS and IPES as well as temperature-dependent V OC measurements.

14 SOLAR ENERGY↗

Direct evidence of low work function on SrVO 3 cathode using thermionic electron emission microscopy and high-field ultraviolet photoemission spectroscopy

Perovskite SrVO 3 has recently been proposed as a novel electron emission cathode material. Density functional theory (DFT) calculations suggest multiple low work function surfaces, and recent experimental efforts have consistently demonstrated effective work functions of ~2.7 eV for polycrystalline samples, both results suggesting, but not directly confirming, that some fraction of even lower work function surface is present. In this work, thermionic electron emission microscopy (ThEEM) and high-field ultraviolet photoemission spectroscopy (UPS) are used to study the local work function distribution and measure the work function of a partially oriented- (110)-SrVO 3 perovskite oxide cathode surface. Our results show direct evidence of low work function patches of about 2.0 eV on the cathode surface, with a corresponding onset of observable thermionic emission at 750 °C. We hypothesize that, in our ThEEM and UPS experiments, the high applied electric field suppresses the patch field effect, enabling the direct measurement of local work functions. This measured work function of 2.0 eV is comparable to the previous DFT-calculated work function values of the SrVO-terminated (110) SrVO 3 surface (2.3 eV) and SrO-terminated (100) surface (1.9 eV). The measured 2.0 eV value is also much lower than the work function for the (001) LaB 6 single crystal cathode (~2.7 eV) and comparable to the effective work function of B-type dispenser cathodes (~2.1 eV). If SrVO 3 thermionic emitters can be engineered to access domains of this low 2.0 eV work function, they have the potential to significantly improve thermionic emitter-based technologies.

36 MATERIALS SCIENCE↗

Impact of Detailed Parameter Modeling of Open-Cycle Gas Turbines on Production Cost Simulation: Preprint

Flexible resources are increasingly important as variable renewable energy deployment in the power system increases. Although many systems are transitioning away from fossil fuels, open-cycle gas turbines are likely to play an important balancing role for some time, thus requiring accurate modeling of their operational parameters. This paper explores the impact of detailed representation of three operational parameters - start- up costs, run-up rates, and forced outage rates - in the production cost model of a system as it adopts higher levels of wind and solar. Using PLEXOS simulations of the NREL-118 bus test system, the study examines how more detailed parameter modeling affects outcomes such as the number of start-ups and shutdowns, ramping and total generation costs for open-cycle gas turbines, as renewable energy levels increase. The results suggest the value of detailed parameter modeling and continued research on combustion turbines' ability to provide flexibility.

economic dispatch↗

Operation of Dual-T-Type Modular Multilevel Converter for Uninterrupted Power Supply Under Bridge Failures

Dual-T-type modular multilevel converter (DTMMC) is an alternative to the existing uninterrupted power supply (UPS) due to its advantage in flexible leg reusing, multiple power ports, and high operating efficiency. Here, in this article, a DTMMC-UPS, which has series configurations on both input/output ac sides, obtains high-voltage grid/load accessing interfaces is presented. In the described system, the fact that copies of T-type legs are employed makes semiconductor failure common to happen. Moreover, both the coupling between rectifier and inverter conversions and the confliction between intercell and inner-cell voltage balancing make fault-tolerant control a tough issue. In this article, the switch fault types are first clarified and diagnosed by the different impacts on normal operation. An improved voltage vector modulation is then deduced to facilitate the planning of proper primary switching patterns, to achieve rectifier side normal operation. The secondary alternated level-shifted pulsed-width modulation (LS-PWM) is also modified to achieve inverter side normal operation. The experiment results are supplied to verify the validity of the modulation-coordinated fault toleration strategy.

42 ENGINEERING↗