Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Triage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Deep learning models for interpretation of point of care ultrasound in military working dogs

Introduction: Military working dogs (MWDs) are essential for military operations in a wide range of missions. With this pivotal role, MWDs can become casualties requiring specialized veterinary care that may not always be available far forward on the battlefield. Some injuries such as pneumothorax, hemothorax, or abdominal hemorrhage can be diagnosed using point of care ultrasound (POCUS) such as the Global FAST® exam. This presents a unique opportunity for artificial intelligence (AI) to aid in the interpretation of ultrasound images. In this article, deep learning classification neural networks were developed for POCUS assessment in MWDs. Methods: Images were collected in five MWDs under general anesthesia or deep sedation for all scan points in the Global FAST® exam. For representative injuries, a cadaver model was used from which positive and negative injury images were captured. A total of 327 ultrasound clips were captured and split across scan points for training three different AI network architectures: MobileNetV2, DarkNet-19, and ShrapML. Gradient class activation mapping (GradCAM) overlays were generated for representative images to better explain AI predictions. Results: Performance of AI models reached over 82% accuracy for all scan points. The model with the highest performance was trained with the MobileNetV2 network for the cystocolic scan point achieving 99.8% accuracy. Across all trained networks the diaphragmatic hepatorenal scan point had the best overall performance. However, GradCAM overlays showed that the models with highest accuracy, like MobileNetV2, were not always identifying relevant features. Conversely, the GradCAM heatmaps for ShrapML show general agreement with regions most indicative of fluid accumulation. Discussion: Overall, the AI models developed can automate POCUS predictions in MWDs. Preliminarily, ShrapML had the strongest performance and prediction rate paired with accurately tracking fluid accumulation sites, making it the most suitable option for eventual real-time deployment with ultrasound systems. Further integration of this technology with imaging technologies will expand use of POCUS-based triage of MWDs.

59 BASIC BIOLOGICAL SCIENCES↗

Optical Spectroscopy and Multivariate Analysis for Biodosimetry and Monitoring of Radiation Injury to the Skin

In the event of an intentional or accidental release of ionizing radiation in a densely populated area, timely assessment and triage of the general population for the radiation exposure is critical. In particular, a significant number of the victims may sustain cutaneous radiation injury, which increases the mortality and worsens the overall prognosis of the victims suffered from combined thermal/mechanical and radiation trauma. Diagnosis of the cutaneous radiation injury is challenging, and established methods largely rely on visual manifestations, presence of the skin contamination, and a high degree of recall by the victim. Availability of a high throughput non-invasive in vivo biodosimetry tool for assessment of the radiation exposure of the skin is of particular importance for the timely diagnosis of the cutaneous injury. In the reported investigation, we have tested the potential of an optical reflectance spectroscopy for the evaluation of the radiation injury to the skin. This is technically attractive because optical spectroscopy relies on well-established and routinely used for various applications instrumentation, one example being pulse oximetry which uses selected wavelengths for the quantification of the blood oxygenation. Our method relies on a broad spectral region ranging from the locally absorbed, shallow-penetrating ultraviolet and visible (250 to 800 nm) to more deeply penetrating near-Infrared (800 – 1600 nm) light for the monitoring of multiple physiological changes in the skin upon irradiation. Chemometrics is a multivariate methodology that allows the information from entire spectral region to be used to generate predictive regression models. In this report we demonstrate that simple spectroscopic method, such as the optical reflectance spectroscopy, in combination with multivariate data analysis, offers the promise of rapid and non-invasive in vivo diagnosis and monitoring of the cutaneous radiation exposure, and is able accurately predict the dose and time of exposure in the rodent model.

Levitskaia, Tatiana G↗

Extension of lymphocyte viability for radiation biodosimetry: Potential implications for radiological/nuclear mass casualty incidents

Abstract Dicentric chromosome assay (DCA) is routinely used for estimating the absorbed radiation dose in exposed humans. Optimal lymphocyte viability is crucial for reliable dose estimation and most cytogenetic laboratories prefer the receipt of blood samples within 24 to 36 hours after collection. Delays in the shipment/receipt of samples can occur sometimes under certain unforeseen circumstances: (1) Adverse weather conditions, (2) distant location of blood collection sites, and (3) shipping and handling of a large number of samples after radiological/nuclear mass casualty incident(s). To circumvent some of these limitations, we evaluated the suitability of ex vivo irradiated blood samples stored in the presence of phytohemagglutinin (PHA) for 7 days at ambient temperature (22‐24°C) for radiation biodosimetry. Blood samples stored in the presence of PHA for up to 7 days showed a higher mitotic index than blood samples stored without PHA. To verify the use of stored blood samples for DCA, frequencies of X‐rays induced dicentric chromosomes were analyzed in the blood samples that were cultured either 24 hours after exposure or 7 days later after storage. Our results indicate that storage of ex vivo irradiated blood samples in the presence of PHA at ambient temperature was found optimal for DCA and that the radiation doses estimated by dicentric chromosome frequencies were grossly similar between the fresh and stored blood samples. Our study suggests that reliable and accurate biodosimetry results can be obtained for triage using blood samples stored for up to a week at ambient temperature in the presence of PHA.

Smith, Tammy↗

Single institutional experience with initial ultrasound followed by computed tomography or magnetic resonance imaging for acute appendicitis in adults

Purpose: The objectives of this study was to assess the performance of ultrasound (US) for suspected appendicitis in adult patients and to evaluated the additive value of short-interval (within 1 week) computed tomography (CT) or Magnetic Resonance Imaging (MRI) after performing an initial US. Methods: In this IRB-approved, HIPAA-compliant, retrospective study, electronic medical records (EMRs) were queried for “US appendicitis” performed over a 2-year interval. EMR was reviewed for CT or MRI performed within 1 week of this exam, and if any new or additional information was available at subsequent exam. White count, patient disposition, and pathology, if surgery was performed, were also recorded. Results: 682 patients underwent US for appendicitis over a 2-year duration, age range from 18 to 92 years (average: 30.1 years, M:F = 141:541). Findings showed 126/682 patients with normal appendix, 75/682 uncomplicated appendicitis, and 4/682 with complicated appendicitis. When performed, no additional findings were seen in these groups on short-interval CT or MRI. 2/682 patients had equivocal findings on US but eventually had normal appendix identified on CT. Four hundred and seventy-three patients had non-visualized appendix, of which only 14/473 (3.1%) eventually had appendicitis. Conclusions: Ultrasound is an effective initial modality for evaluating appendicitis even in adult patients. Once a normal appendix, uncomplicated or complicated appendicitis is identified on US, no further imaging is necessary. Very few patients with non-visualization of the appendix eventually have appendicitis. Hence, these patients can be managed with active clinical follow-up rather than immediate CT or MRI. Symptoms and clinical scoring systems can be used for triage of these patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Acute non-traumatic abdominal pain by quadrant: relative yield of CT and clinical evaluation for diagnosis in 1000 patients

Objective: To determine the relative diagnostic yield of contrast-enhanced CT in adults presenting with symptoms referable to a specific abdominal quadrant. Methods: Electronic health records review systematically identified patients meeting the following inclusion criteria: adults (≥ 18 years) undergoing IV contrast-enhanced abdominopelvic CT for acute non-traumatic symptoms referable to a specific abdominal quadrant (RLQ/LLQ/LUQ/RUQ). The CT-based diagnosis and any clinical diagnosis in the absence of CT diagnosis were recorded. The final cohort of 1000 subjects (mean age, 48.1 years; 647F/353M) consisted of consecutive sub-cohorts of 250 patients for each abdominal quadrant. Positive oral contrast was utilized in 91.6% (916/1000) of cases. Results: A positive CT diagnosis was provided in 47.3% (473/1000) of all patients, and was highest for LLQ (58.8%) and RLQ (58.0%) symptoms, including diverticulitis and appendicitis in 23.6% and 24.8% cases, respectively. CT positivity was lower for the LUQ (34.4%) and RUQ (38.0%) (p < 0.0001), with no single diagnosis representing > 5% of cases. However, all quadrants provided valuable triage of 218 hospital admissions (21.8%), 83.0% were CT positive, whereas 62.7% of 782 discharged patients were CT negative. Only 7.0% of CT-negative patients were admitted. A clinical-only diagnosis was provided in 9.3% of the total cohort (93/1000), representing 17.6% of the CT-negative cohort (93/527). Conclusion: The rate of positive CT diagnosis is considerably higher for the lower abdominal quadrants, predominately due to appendicitis and diverticulitis. However, CT results (positive vs. negative) for all four quadrants strongly correlated with hospital admission versus discharge. Clinical-only diagnosis represented < 10% of all cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Utilization of stress testing for low-risk patients with chest discomfort in the emergency department

Background: The management of patients presenting to an emergency department with chest discomfort at low-risk for acute coronary syndrome represents a common clinical challenge. Such patients are often triaged to chest pain units for monitoring and cardiac stress testing for further risk stratification. Methods: We conducted a retrospective study of 292 low-risk patients who presented to an emergency department with chest discomfort. We performed physician-adjudicated chart reviews of all patients with positive stress tests to assess downstream testing, subsequent coronary revascularization, and outcomes. Results: Of the 292 patients, 33 (11.3%) had stress tests positive for ischemia, and 12 (4.1%) underwent diagnostic cardiac catheterization. Of the 292 patients, 4 (1.4%) underwent coronary revascularization that may have resulted in a mortality benefit. Conclusion: These data suggest a very low yield of detecting clinically significant coronary disease with stress testing low-risk patients with chest discomfort in emergency department chest pain units.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Emergency department overcrowding and its associated factors at HARME medical emergency center in Eastern Ethiopia

Introduction: Emergency department (ED) overcrowding has become a significant concern as it can lead to compromised patient care in emergency settings. Various tools have been used to evaluate overcrowding in ED. However, there is a lack of data regarding this issue in resource-limited countries, including Ethiopia. This study aimed to validate NEDOCS, assess level of ED overcrowding and identify associated factors at HARME Medical Emergency Center, located in Hiwot Fana Comprehensive Specialized Hospital, Harar, Ethiopia. Methods: A cross-sectional study was conducted at the HARME Medical Emergency Center, Hiwot Fana Comprehensive Specialized Hospital, involving a total of 899 patients during 120 sampling intervals. The area under the receiver operating characteristic curves (AUC) was calculated to evaluate the agreement between objective and subjective assessments of ED overcrowding. A multivariable logistic regression analysis was employed to identify factors associated with ED overcrowding and statistically significant association was declared using 95% confidence level and a p-value < 0.05. Results: The interrater agreement showed a strong correlation with a Cohen's kappa (κ) of 0.80. The National Emergency Department Overcrowding Study Score demonstrated a strong association with subjective assessments from residents and case team nurses, with an AUC of 0.81 and 0.79, respectively. According to residents' perceptions, ED were considered overcrowded 65.8% of the time. Factors significantly associated with ED overcrowding included waiting time for triage (AOR: 2.24; 95% CI: 1.54–3.27), working time (AOR: 2.23; 95% CI: 1.52–3.26), length of stay (AOR: 2.40; 95% CI: 1.27–4.54), saturation level (AOR: 2.35; 95% CI: 1.31–4.20), chronic illness (AOR: 2.19; 95% CI: 1.37–3.53), and abnormal pulse rate (AOR: 1.52; 95% CI: 1.06–2.16). Conclusion: The study revealed that ED were overcrowded approximately two-thirds of the time.

60 APPLIED LIFE SCIENCES↗

Lethality is Local, but Survival is Systemic: Temporal and Multi-Organ Responses to Chlorine Gas Exposure in a Murine Model

Chlorine gas (Cl2) is a highly toxic chemical associated with both localized lung injury and systemic health effects. While pulmonary damage has been well characterized, the systemic inflammatory and metabolic responses remain poorly understood. We aimed to define the temporal and multi-organ responses to Cl2 exposure in a murine model, with a focus on identifying spatiotemporal inflammation and its impact on survival and lethality. SKH1 mice were exposed for 10 min to varying concentrations of Cl2 (94.4–810 ppm, representative of non-lethal, LD10, and LD50 doses) and monitored for respiratory function, perfusion, and acidosis using organ-specific imaging. At multiple time points (40 min, 6 h, 24 h, and 7 d), we measured phosphoproteins, cytokines, chemokines, growth factors, and metabolic hormones in the lungs, heart, cortex, and plasma. Statistical modeling and logistic regression were used to identify biomarkers associated with lethality and survival. We found that lung injury was the primary cause of potential lethality, particularly via early phosphoprotein signaling disruptions. However, survival correlated with early systemic coordination of inflammatory and metabolic signals across organs. Perfusion and acidosis imaging were strongly associated with chemokine and hormone responses. Key survival-associated plasma biomarkers included decreased insulin, increased ghrelin, and decreased eotaxin. While potential lethality from Cl2 exposure is locally driven by pulmonary injury, survival depends on systemic, multi-organ responses that occur rapidly post-exposure. Within this model, our findings identify a potential therapeutic window to enhance survival and suggest candidate biomarkers that may be explored translationally for both triage and treatment of chlorine-related incidents.

chlorine gas↗

Identifying Urinary and Serum Exosome Biomarkers for Radiation Exposure Using a Data Dependent Acquisition and SWATH-MS Combined Workflow

Purpose: Early and accurate assessment of radiation injury by radiation-responsive biomarkers is critical for triage and early intervention. Biofluids such as urine and serum are convenient for such analysis. Recent research has also suggested that exosomes are a reliable source of biomarkers in disease progression. In the present study, we analyzed total urine proteome and exosomes isolated from urine or serum for potential biomarkers of acute and persistent radiation injury in mice exposed to lethal whole body irradiation (WBI). Methods and Materials: For feasibility studies, the mice were irradiated at 10.4 Gy WBI, and urine and serum samples were collected 24 and 72 hours after irradiation. Exosomes were isolated and analyzed using liquid chromatography mass spectrometry/mass spectrometry-based workflow for radiation exposure signatures. A data dependent acquisition and SWATH-MS combined workflow approach was used to identify significantly exosome biomarkers indicative of acute or persistent radiation-induced responses. For the validation studies, mice were exposed to 3, 6, 8, or 10 Gy WBI, and samples were analyzed for comparison. Results: A comparison between total urine proteomics and urine exosome proteomics demonstrated that exosome proteomic analysis was superior in identifying radiation signatures. Feasibility studies identified 23 biomarkers from urine and 24 biomarkers from serum exosomes after WBI. Urinary exosome signatures identified different physiological parameters than the ones obtained in serum exosomes. Exosome signatures from urine indicated injury to the liver, gastrointestinal, and genitourinary tracts. In contrast, serum showed vascular injuries and acute inflammation in response to radiation. Selected urinary exosomal biomarkers also showed changes at lower radiation doses in validation studies. Conclusions: Exosome proteomics revealed radiation- and time-dependent protein signatures after WBI. A total of 47 differentially secreted proteins were identified in urinary and serum exosomes. Together, these data showed the feasibility of defining biomarkers that could elucidate tissue-associated and systemic response caused by high-dose ionizing radiation. This is the first report using an exosome proteomics approach to identify radiation signatures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose conversion factors for absorbed dose in a mobile phone to absorbed dose in critical organs in an anthropomorphic phantom for emergency dosimetry applications: OSL and TL experimental results, and Monte Carlo simulations

Here, an anthropomorphic phantom was equipped with three smartphones and irradiated in five separate exposure geometries in air using a 137 Cs source. The phantom was fitted internally with thermoluminescence dosimeters (TLD-700 chips) to measure the absorbed dose to the individual organs, while the absorbed doses in the phones were evaluated using optically stimulated luminescence (OSL) from the phones’ surface mount resistors (SMRs), along with reference dosimeters, namely Luxel OSL films and TLD-700 chips. The results indicate a strong dependence on the phone location with respect to the source due to shielding and scattering from the body. Dose conversion factors were calculated for several plausible exposure scenarios in order to correlate the absorbed doses measured in the phones to the average body dose received by the phantom. The measured conversion factors were compared with calculated factors using MCNP6.2 Monte Carlo simulations and an ADAM voxel phantom. Experiments were conducted to assess how the phone orientation and angle impacts the dose received by the phone components. The overall results indicate that the doses measured can vary significantly depending upon exposure geometry (including phone position and angle). However, in rotational irradiation symmetry, the phone doses lead to an over-estimate of the average whole-body dose by an average of ~10%, independent of the phone locations tested in this study. This result, if confirmed in future studies, may be acceptable for triage.

61 RADIATION PROTECTION AND DOSIMETRY↗

A review of criticality dosimetry at the Y-12 National Security Complex and practical importance of dose accuracy in emergency response

A nuclear criticality results in the emission of both neutron and gamma radiation and can produce doses to personnel near the event that exceed 0.1 Gy (10 rad). The primary purpose of nuclear accident dosimetry is to rapidly identify affected personnel in need of prompt medical treatment and to reassure personnel who have been only minimally exposed. While accurate dosimetry is desired, it must be recognized that dose determinations made from whole-body dosimeters or simple triage methods are very rough estimates and contain significant uncertainties. Even when accounting for factors like varying neutron energy spectra, mean photon energies, body orientation within the radiation field, and transient effects on dosimeter response, etc., the end value is a dosimetric quantity defined for very specific radiological conditions and determined within a simple phantom usually at a single depth. Of more importance is the biological response to the radiation, which will vary by person and can be affected by the individual’s radiation sensitivity, age, gender, mass, and underlying health conditions. The overall biological, person-specific response to a given dose cannot be precisely determined except by patient symptom observation and individual biological dosimetry (e.g. chromosome analysis, lymphocyte ratios, etc.). This work describes and discusses the criticality accident dosimetry program at the Y-12 National Security Complex, a United States Department of Energy National Nuclear Security Administration facility. In conclusion, the primary goals of the Y-12 accident dosimetry program are, among others, the rapid identification of significantly exposed persons, prompt routing of exposed workers for medical evaluation and treatment, and the ultimate processing of dosimeters to assign doses to personnel.

61 RADIATION PROTECTION AND DOSIMETRY↗

Nanosensor dosimetry of mouse blood proteins after exposure to ionizing radiation

Giant magnetoresistive (GMR) nanosensors provide a novel approach for measuring protein concentrations in blood for medical diagnosis. Using an in vivo mouse radiation model, we developed protocols for measuring Flt3 ligand (Flt3lg) and serum amyloid A1 (Saa1) in small amounts of blood collected during the first week after X-ray exposures of sham, 0.1, 1, 2, 3, or 6 Gy. Flt3lg concentrations showed excellent dose discrimination at $ 1 Gy in the time window of 1 to 7 days after exposure except 1 Gy at day 7. Saa1 dose response was limited to the first two days after exposure. A multiplex assay with both proteins showed improved dose classification accuracy. Our magneto-nanosensor assay demonstrates the dose and time responses, low-dose sensitivity, small volume requirements, and rapid speed that have important advantages in radiation triage biodosimetry.

BIONANOELECTRONICS↗

Prototyping and validating requirements of radiation and nuclear emergency plan simulator

Organizational incapability in developing unrealistic, impractical, inadequate and ambiguous mechanisms of radiological and nuclear emergency preparedness and response plan (EPR) causing emergency plan disorder and severe disasters. These situations resulting from 65.6% of poor definition and unidentified roles and duties of the disaster coordinator. Those unexpected conditions brought huge aftermath to the first responders, operators, workers, patients and community at large. Hence, in this report, we discuss prototyping and validating of Malaysia radiation and nuclear emergency preparedness and response plan simulation model (EPRM). A prototyping technique was required to formalize the simulation model requirements. Prototyping as systems requirements validation was carried on to endorse the correctness of the model itself against the stakeholder’s intensions in resolving those organizational incapability. We have made assumptions for the proposed emergency preparedness and response model (EPRM) through the simulation software. Those assumptions provided a twofold of expected mechanisms, planning and handling of the respective emergency plan as well as in bringing off the hazard involved. This model called RANEPF (Radiation and Nuclear Emergency Planning Framework) simulator demonstrated the training emergency response perquisites rather than the intervention principles alone. The demonstrations involved the determination of the casualties’ absorbed dose range screening and the coordination of the capacity planning of the expected trauma triage. Through user-centred design and sociotechnical approach, RANEPF simulator was strategized and simplified, though certainly it is equally complex.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

TranSyT , an innovative framework for identifying transport systems

The importance and rate of development of genome-scale metabolic models have been growing for the last few years, increasing the demand for software solutions that automate several steps of this process. However, since TRIAGE’s release, software development for the automatic integration of transport reactions into models has stalled. Here, in this paper, we present the Transport Systems Tracker (TranSyT). Unlike other transport systems annotation software, TranSyT does not rely on manual curation to expand its internal database, which is derived from highly curated records retrieved from the Transporters Classification Database and complemented with information from other data sources. TranSyT compiles information regarding transporter families and proteins, and derives reactions into its internal database, making it available for rapid annotation of complete genomes. All transport reactions have GPR associations and can be exported with identifiers from four different metabolite databases. TranSyT is currently available as a plugin for merlin v4.0 and an app for KBase.

59 BASIC BIOLOGICAL SCIENCES↗

Cervical Precancers and Cancers Attributed to HPV Types by Race and Ethnicity: Implications for Vaccination, Screening, and Management

Abstract Background Racial and ethnic variations in attribution of cervical precancer and cancer to human papillomavirus (HPV) types may result in different HPV vaccine protection, screening test coverage, and clinical management. Methods Pooling data from 7 US studies, we calculated the proportional attribution of precancers and cancers to HPV types using HPV DNA typing from diagnosis. All statistical tests were 2-sided. Results For all racial and ethnic groups, most cases of cervical intraepithelial neoplasia grade 3 (CIN3) (84.2%-90.8% of 5526) and squamous cell carcinoma (SCC) (90.4%-93.8% of 1138) were attributed to types targeted by the 9-valent vaccine. A higher proportion of CIN3s were attributed to nonvaccine HPV types among non-Hispanic Black women (15.8%) compared with non-Hispanic Asian or Pacific Islander (9.7%; P = .002), non-Hispanic White (9.2%; P < .001), and Hispanic (11.3%; P = .004) women. The proportion of SCCs attributed to 9-valent types was similar by race and ethnicity (P = .80). A higher proportion of CIN3s were attributed to nonvaccine HPV35 among non-Hispanic Black (9.0%) compared with non-Hispanic Asian or Pacific Islander (2.2%), non-Hispanic White (2.5%), and Hispanic (3.0%; all P < .001) women. Compared with CIN3, the proportion of SCCs attributed to HPV35 among non-Hispanic Black women (3.2%) was lower and closer to other groups (0.3%-2.1%; P = .70). Conclusion The 9-valent HPV vaccine will prevent nearly all cervical precancers and invasive cancers among major racial and ethnic groups in the United States. Adding HPV35 to vaccines could prevent a small percentage of CIN3s and SCCs, with greater potential impact for CIN3s among Black women. HPV screening tests target high-risk HPV types, including HPV35. Future genotyping triage strategies could consider the importance of HPV35- and other HPV16-related types.

Mix, Jacqueline (ORCID:0000000164187706)↗

Comparative Performance of Three Eye-Tracking Devices in Detection of Mild Traumatic Brain Injury in Acute Versus Chronic Subject Populations

ABSTRACT Introduction Presently, traumatic brain injury (TBI) triage in field settings relies on symptom-based screening tools such as the updated Military Acute Concussion Evaluation. Objective eye-tracking may provide an alternative means of neurotrauma screening due to sensitivity to neurotrauma brain-health changes. Previously, the US Army Medical Research and Development Command Non-Invasive NeuroAssessment Devices (NINAD) Integrated Product Team identified 3 commercially available eye-tracking devices (SyncThink EYE-SYNC, Oculogica EyeBOX, NeuroKinetics IPAS) as meeting criteria toward being operationally effective in the detection of TBI in service members. We compared these devices to assess their relative performance in the classification of mild traumatic brain injury (mTBI) subjects versus normal healthy controls. Materials and Methods Participants 18 to 45 years of age were assigned to Acute mTBI, Chronic mTBI, or Control group per study criteria. Each completed a TBI assessment protocol with all 3 devices counterbalanced across participants. Acute mTBI participants were tested within 72 hours following injury whereas time since last injury for the Chronic mTBI group ranged from months to years. Discriminant analysis was undertaken to determine device classification performance in separating TBI subjects from controls. Area Under the Curves (AUCs) were calculated and used to compare the accuracy of device performance. Device-related factors including data quality, the need to repeat tests, and technical issues experienced were aggregated for reporting. Results A total of 63 participants were recruited as Acute mTBI subjects, 34 as Chronic mTBI subjects, and 119 participants without history of TBI as controls. To maximize outcomes, poorer quality data were excluded from analysis using specific criteria where possible. Final analysis utilized 49 (43 male/6 female, mean [x̅] age = 24.3 years, SD [s] = 5.1) Acute mTBI subjects, and 34 (33 male/1 female, x̅ age = 38.8 years, s = 3.9) Chronic mTBI subjects were age- and gender-matched as closely as possible with Control subjects. AUCs obtained with 80% of total dataset ranged from 0.690 to 0.950 for the Acute Group and from 0.753 to 0.811 for the Chronic mTBI group. Validation with the remaining 20% of dataset produced AUCs ranging from 0.600 to 0.750 for Acute mTBI group and 0.490 to 0.571 for the Chronic mTBI group. Conclusions Potential eye-tracking detection of mTBI, per training model outcomes, ranged from acceptable to excellent for the Acute mTBI group; however, it was less consistent for the Chronic mTBI group. The self-imposed targeted performance (AUC of 0.850) appears achievable, but further device improvements and research are necessary. Discriminant analysis models differed for the Acute versus Chronic mTBI groups, suggesting performance differences in eye-tracking. Although eye-tracking demonstrated sensitivity in the Chronic group, a more rigorous and/or longitudinal study design is required to evaluate this observation. mTBI injuries were not controlled for this study, potentially reducing eye-tracking assessment sensitivity. Overall, these findings indicate that while eye-tracking remains a viable means of mTBI screening, device-specific variability in data quality, length of testing, and ease of use must be addressed to achieve NINAD objectives and DoD implementation.

General & Internal Medicine↗

Measurable radiation levels around individuals externally contaminated by nuclear fallout

During the early response to large-scale radioactive contamination events, people who are potentially affected need to be screened for radioactive contamination and public health staff need to triage individuals who may need immediate decontamination. This is typically done by screening individuals for external contamination using ionising radiation detection equipment. In this study, spatially and temporally dependent isotopic compositions from a simulated nuclear detonation and Monte Carlo methods were used to relate contamination activity levels to the measurable radiation levels at select distances away from an individual with whole-body contamination. Radionuclide-specific air kerma rate coefficients and Geiger–Mueller instrument response coefficients at five select distances from contaminated individuals are presented for 662 radionuclides. Temporally and spatially dependent incident-specific coefficients are presented for a hypothetical surface detonation of a 235 U-fueled device.

61 RADIATION PROTECTION AND DOSIMETRY↗

Microbial inoculants for soil restoration: A Risk-Proportional Stewardship Framework Integrating Strain-Resolved Genomics and Adaptive Governance

Global soil degradation and increasing reliance on chemical inputs threaten agricultural sustainability, driving interest in microbial inoculants as tools for soil restoration. These biological products have the potential to enhance nutrient cycling, improve soil structure, and support plant resilience, but their environmental release raises important safety and stewardship considerations. Here, we propose a risk-proportional framework for the responsible deployment of microbial inoculants grounded in release-based stewardship. The framework integrates genome-resolved strain identification, exclusionary hazard screening, bioassay-based risk triage, ecological testing under realistic conditions, and monitored field deployment. Drawing on evidence from microbial ecology and invasion biology, we highlight how inoculants can alter resident microbial communities, influence ecosystem function, and, in some cases, facilitate gene flow, underscoring the need for risk assessment. We further outline a federated, genome-informed data infrastructure to support traceability, cross-jurisdiction learning, and adaptive management. Together, this approach provides a scalable and scientifically grounded pathway to balance innovation and safety, enabling microbial technologies to contribute to soil restoration and climate-resilient agriculture.

Edlund, Anna [OATH Inc]↗