Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Transfer Function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Atmospheric turbulence affects wind turbine nacelle transfer functions

Despite their potential as a valuable source of individual turbine power performance and turbine array energy production optimization information, nacelle-mounted anemometers have often been neglected because complex flows around the blades and nacelle interfere with their measurements. This work quantitatively explores the accuracy of and potential corrections to nacelle anemometer measurements to determine the degree to which they may be useful when corrected for these complex flows, particularly for calculating annual energy production (AEP) in the absence of other meteorological data. Using upwind meteorological tower measurements along with nacelle-based measurements from a General Electric (GE) 1.5sle model, we calculate empirical nacelle transfer functions (NTFs) and explore how they are impacted by different atmospheric and turbulence parameters. This work provides guidelines for the use of NTFs for deriving useful wind measurements from nacelle-mounted anemometers. Corrections to the nacelle anemometer wind speed measurements can be made with NTFs and used to calculate an AEP that comes within 1% of an AEP calculated with upwind measurements. We also calculate unique NTFs for different atmospheric conditions defined by temperature stratification as well as turbulence intensity, turbulence kinetic energy, and wind shear. During periods of low stability as defined by the Bulk Richardson number ( R B ), the nacelle-mounted anemometer underestimates the upwind wind speed more than during periods of high stability at some wind speed bins below rated speed, leading to a steeper NTF during periods of low stability. Similarly, during periods of high turbulence, the nacelle-mounted anemometer underestimates the upwind wind speed more than during periods of low turbulence at most wind bins between cut-in and rated wind speed. Based on these results, we suggest different NTFs be calculated for different regimes of atmospheric stability and turbulence for power performance validation purposes.

17 WIND ENERGY↗

Assessing the validity of modulation transfer function evaluation techniques with application to small area and scanned digital detectors

A novel prototype step and shoot x-ray system, the intelligent imaging system (I-Imas), has been developed in the UCL Radiation Physics laboratories. The system uses collimators to split the beam into two: the first, 'scout' beam, strongly attenuated, identifies regions of interest in the image. This information is then fed back to the system so that the intensity of the second beam is modulated to optimize the dose distribution--i.e., ''interesting'' regions of the sample receive a higher dose, whereas other regions receive a lower one. Such systems may be capable of improved diagnostic capability at the same overall patient dose levels as typical when using large area digital plates. This acquisition mode means that large overall images are obtained by aligning many smaller images. This paper investigates the effects that this acquisition modality has on the overall spatial resolution of the system. We review different modulation transfer function (MTF) evaluation techniques and those shown to be optimal are used in the investigation of two considerations key to such a system: (i) whether there is a minimum size sensor whose MTF can accurately be determined using these techniques and (ii) whether the MTF of the large overall image differs significantly from those of the many constituent images. As the use of step and shoot systems is becoming more and more widespread, both are important considerations. We found that, for a fixed pixel pitch, the MTF is determined marginally less accurately the smaller the sensor area, with the perceived resolution varying by up to 0.1 lp/mm. It was also found that use of such a step and shoot technique does cause a very small overall degradation in resolution. The resolution of overall images was calculated to be 0.1 lp/mm lower than that of the individual images acquired.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Visualizing the bidirectional optical transfer function for near-field enhancement in waveguide coupled plasmonic transducers

Here, we report visualizations of the bidirectional near-field optical transfer function for a waveguide-coupled plasmonic transducer as a metrology technique essential for successful development for mass-fabricated near-field devices. Plasmonic devices have revolutionized the observation of nanoscale phenomena, enabling optical excitation and readout from nanoscale regions of fabricated devices instead of as limited by optical diffraction. Visualizations of the plasmonic transducer modes were acquired both by local near-field excitation of the antenna on the front facet of a waveguide using the focused electron beam of a scanning electron microscope as a probe of the near-field cathodoluminescence during far-field collection from the back facet of the waveguide, and by local mapping of the optical near-field for the same antenna design using scattering scanning near-field optical microscopy as a probe of the near-field optical mode density for far-field light focused into the back facet of the waveguide. Strong agreement between both measurement types and numerical modeling was observed, indicating that the method enables crucial metrological comparisons of as fabricated device performance to as-modeled device expectations for heat-assisted magnetic recording heads, which can be extended to successful development of future near-field-on-chip devices such as optical processor interconnects.

42 ENGINEERING↗

DIRECT MEASUREMENT OF THE X-RAY TIME-DELAY TRANSFER FUNCTION IN ACTIVE GALACTIC NUCLEI

The origin of the observed time lags, in nearby active galactic nuclei (AGNs), between hard and soft X-ray photons is investigated using new XMM-Newton data for the narrow-line Seyfert I galaxy Ark 564 and existing data for 1H 0707-495 and NGC 4051. These AGNs have highly variable X-ray light curves that contain frequent, high peaks of emission. The averaged light curve of the peaks is directly measured from the time series, and it is shown that (1) peaks occur at the same time, within the measurement uncertainties, at all X-ray energies, and (2) there exists a substantial tail of excess emission at hard X-ray energies, which is delayed with respect to the time of the main peak, and is particularly prominent in Ark 564. Observation (1) rules out that the observed lags are caused by Comptonization time delays and disfavors a simple model of propagating fluctuations on the accretion disk. Observation (2) is consistent with time lags caused by Compton-scattering reverberation from material a few thousand light-seconds from the primary X-ray source. The power spectral density and the frequency-dependent phase lags of the peak light curves are consistent with those of the full time series. There is evidence for non-stationarity in the Ark 564 time series in both the Fourier and peaks analyses. A sharp 'negative' lag (variations at hard photon energies lead soft photon energies) observed in Ark 564 appears to be generated by the shape of the hard-band transfer function and does not arise from soft-band reflection of X-rays. These results reinforce the evidence for the existence of X-ray reverberation in type I AGN, which requires that these AGNs are significantly affected by scattering from circumnuclear material a few tens or hundreds of gravitational radii in extent.

79 ASTRONOMY AND ASTROPHYSICS↗

The Sensitivity of Chemical Kinetic Models on Flame Transfer Functions in High Frequency Acoustic Fluctuation Environments

This paper investigates how different chemical kinetics models are able to capture the dynamics of laminar premixed methane/air flames. In particular, this paper computes flame transfer functions and compares the performance of different global kinetic models as well as detailed kinetic models. This is accomplished using a sequence of one-dimensional incompressible simulations implemented in OpenFOAM. The detailed GRI Mech 3.0 is used as a baseline for comparison. Detailed kinetic analysis will be conducted to understand the underlying kinetics-dynamics coupling.

Girdhar, Anant↗

Half-harmonic Kelvin probe force microscopy with transfer function correction

An approach for surface potential imaging based on half-harmonic band excitation (BE) in Kelvin probe force microscopy is demonstrated. Using linear and half-harmonic BE enables quantitative correction of the cantilever transfer function. Half-harmonic band excitation Kelvin probe force microscopy (HBE KPFM) thus allows quantitative separation of surface potential and topographic contributions to the signal, obviating the primary sources of topographic cross-talk. HBE KPFM imaging and voltage spectroscopy methods are illustrated for several model systems.

Guo, Senli↗

Modeling the Transfer Function for the Dark Energy Survey

We present a forward-modeling simulation framework designed to model the data products from the Dark Energy Survey (DES). This forward-model process can be thought of as a transfer function—a mapping from cosmological/astronomical signals to the final data products used by the scientists. Using output from the cosmological simulations (the Blind Cosmology Challenge), we generate simulated images (the Ultra Fast Image Simulator) and catalogs representative of the DES data. In this work we demonstrate the framework by simulating the 244 deg 2 coadd images and catalogs in five bands for the DES Science Verification data. The simulation output is compared with the corresponding data to show that major characteristics of the images and catalogs can be captured. We also point out several directions of future improvements. Two practical examples—star-galaxy classification and proximity effects on object detection—are then used to illustrate how one can use the simulations to address systematics issues in data analysis. With clear understanding of the simplifications in our model, we show that one can use the simulations side-by-side with data products to interpret the measurements. This forward modeling approach is generally applicable for other upcoming and future surveys. It provides a powerful tool for systematics studies that is sufficiently realistic and highly controllable.

79 ASTRONOMY AND ASTROPHYSICS↗

Cross-functional transferability in foundation machine learning interatomic potentials

The rapid development of foundation potentials (FPs) in machine learning interatomic potentials demonstrates the possibility for generalizable learning of the universal potential energy surface. The accuracy of FPs can be further improved by bridging the model from lower-fidelity datasets to high-fidelity ones. In this work, we analyze the challenge of this transfer learning (TL) problem within the CHGNet framework. We show that significant energy scale shifts and poor correlations between GGA and r 2 SCAN hinder cross-functional transferability. By benchmarking different TL approaches on the MP-r 2 SCAN dataset, we demonstrate the importance of elemental energy referencing in the TL of FPs. By comparing the scaling law with and without the pre-training on a low-fidelity dataset, we show that significant data efficiency can still be achieved through TL, even with a target dataset of sub-million structures. We highlight the importance of proper TL and multi-fidelity learning in creating next-generation FPs on high-fidelity data.

Huang, Xu [University of California, Berkeley, CA ↗

Security camera resolution measurements: Horizontal TV lines versus modulation transfer function measurements.

The horizontal television lines (HTVL) metric has been the primary quantity used by division 6000 related to camera resolution for high consequence security systems. This document shows HTVL measurements are fundamen- tally insufficient as a metric to determine camera resolution, and propose a quantitative, standards based methodology by measuring the camera system modulation transfer function (MTF), the most common and accepted metric of res- olution in the optical science community. Because HTVL calculations are easily misinterpreted or poorly defined, we present several scenarios in which HTVL is frequently reported, and discuss their problems. The MTF metric is discussed, and scenarios are presented with calculations showing the application of such a metric.

47 OTHER INSTRUMENTATION↗

Calibration, modeling, parameterization, and verification of the instrument transfer function of an interferometric microscope

Interferometric microscopes are used to measure surface roughness, from which the computed power spectral density function can be used to extract bandwidth-limited values of the various surface properties, such as root-mean-square (rms) height and slope errors. Measurements with a microscope equipped with different objectives that have an overlapping spatial frequency range usually give different rms results over the common frequency bandwidth. This is a result of different instrument transfer functions (ITFs) that attenuate spatial frequencies by different amounts over the overlapping range. We report on the use of binary pseudo-random array (BPRA) standards to characterize the ITF of an interferometric microscope with the various objectives. We use a simple model of a 1D binary Results show that the spectrum for an undersampled array is a cosine function, rather than a straight line, constant white noise spectrum. We have an analytical model of the ITF that includes the effects of an obscured aperture and defocus, in addition to the usual parameters of numerical aperture, wavelength, and sampling period. In addition, the model includes the effect of aliasing of spatial frequency components beyond the Nyquist back into the sub-Nyquist region. We compare the model PSD predictions to the measurements performed with different objectives. Departures of the measured PSDs from the model predictions indicate that there are higher-order ITF corrections yet to be identified and included in the model.

Takacs, PZ↗

Perfect function transfer and interference effects in interacting boson lattices

We show how to perfectly transfer, without state initialization and remote collaboration, arbitrary functions in interacting boson lattices. We describe a possible implementation of state transfer through bosonic atoms trapped in optical lattices or polaritons in on-chip coupled cavities. Significantly, a family of Hamiltonians, both linear and nonlinear, is found which are related to the Bose-Hubbard model and that enable the perfect transfer of arbitrary functions. It is shown that the state transfer between two sites in two-dimensional lattices can result in quantum interference due to the different numbers of intermediate sites in different paths. The signature factor in nuclear physics can be useful to characterize this quantum interference.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Perfect function transfer in two and three dimensions without initialization

We find analytic models that can perfectly transfer, without state initialization or remote collaboration, arbitrary functions in two- and three-dimensional interacting bosonic and fermionic networks. This provides for the possible experimental implementation of state transfer through bosonic or fermionic atoms trapped in optical lattices. A significant finding is that the state of a spin qubit can be perfectly transferred through a fermionic system. Families of Hamiltonians are described that are related to the linear models and that enable the perfect transfer of arbitrary functions. Furthermore, we propose methods for eliminating certain types of errors.

36 MATERIALS SCIENCE↗

Calculation of Transfer Functions of Multilayer Biotissues in the Problems of Correction of Their Fluorescence Spectra

A method for rapid calculation of a flux of stimulated fluorescence of a multilayer optically dense medium with inhomogeneous distribution of the fluorophore has been developed. The light field in the medium at the excitation wavelength of fluorescence is represented by a superposition of incident collimated, incident diffuse, and reflected diffuse fluxes. A two-stream approximation is used to describe the light field in the medium at the wavelength of emission of the fluorescence. Fluxes in adjacent elementary layers of the medium and on its surface are connected by simple matrix operators that are obtained using a combination of engineering approaches of radiation-transfer theory and single-scattering approximation. The calculations of fluorescence fluxes of a four-layer biotissue that are excited and recorded at 400–800 nm are compared with their Monte Carlo simulation with a discrepancy of 1%. The effect of the propagation medium on the fluorescence spectra of 5-ALA-induced protoporphyrin IX that are recorded from human skin was studied, and a technique for their correction that is based on measurements and quantitative analysis of the diffuse reflectance spectrum of skin was proposed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Utah FORGE Telluric Monitoring Experiment Transfer Functions

The Utah Frontier Observatory for Research in Geothermal Energy (FORGE) attempted a stimulation at well 16A(78)-32 during April and May 2022. We recorded telluric and magnetotelluric (MT) data before, during, and after the well stimulation experiment using the FORGE Telluric Monitoring (FTM) array to constrain transients in the Earth's electrical structure caused by the stimulation.

15 GEOTHERMAL ENERGY↗

Temperature compensated transfer function for probability of detection (POD) in high temperature ultrasonic NDE using low temperature signals - 249

Ultrasonic piezoelectric based transducers offer the potential for in-coolant NDT measurements and imaging required at high temperature for the safe operation of advanced small modular reactors (SMRs). Current work estimates a significant 97% reduction in the probability of detection (POD) for an artificial flaw size of 2{lambda} due to degradation of the transducer performance at elevated temperature. The source of variability for POD in the current work is the temperature dependence of material matrix of piezoelectric material PZT-5A used in the sensor. The physics based model developed using finite element method quantifies reduction in the scattering amplitude for the side drilled hole (SDH) from 15 C to 195 C. Using model assisted probability of detection (MAPOD) approach, sensor temperature effect on the POD is demonstrated for SDHs in the low carbon steel specimen. Scattering amplitudes for the room temperature simulated data is validated with the experimental data. A temperature correction factor and transfer factors are reported to transform the simulated temperature effect from physics based model to the experimental data for estimation of high temperature POD using low temperature ultrasonic measurements. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High Precision Tune and Coupling Feedback and Beam Transfer Function Measurements in RHIC

Precision measurement and control of the betatron tunes and betatron coupling in the Relativistic Heavy Ion Collider (RHIC) are required for establishing and maintaining both good operating conditions and, particularly during the ramp to high beam energies, high proton beam polarization. While the proof-of-principle for simultaneous tune and coupling feedback was successfully demonstrated earlier, routine application of these systems has only become possible recently. Following numerous modifications for improved measurement resolution and feedback control, the time required to establish full-energy beams with the betatron tunes and coupling regulated by feedback was reduced from several weeks to a few hours. A summary of these improvements, select measurements benefitting from the improved resolution and a review of system performance are the subject of this report.

43 PARTICLE ACCELERATORS↗