Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Transducers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Evaluation of several ultrasonic flowmeter transducers in cryogenic environment

Eighteen piezoelectric ultrasonic flowmeter transducers were laboratory tested to determine their suitability and long range reliability for use by the National Transonic Facility (NTF) to measure the flow rate of 450 Kg/sec of liquid nitrogen (LN2). Tests included thermally cycling each transducer 50 to 150 times over a temperature range of 295 K (ambient) to 77 K (LN2). The transducers were submerged in liquid nitrogen for 1 to 4 hours and the signal strength and quality noted. Results disclose that the current state-of-the-art ultrasonic flow transducers are very reliable and will meet the stringent requirements of the NTF.

Moughon, W. C.↗

Portable dynamic pressure generator for static and dynamic calibration of in situ pressure transducers

A portable dynamic pressure generator was developed to meet the requirements of determining the dynamic sensitivities of in situ pressure transducers at low frequencies. The device is designed to operate in a frequency range of 0 to 100 Hz, although it was only tested up to 30 Hz, and to generate dynamic pressures up to 13.8 kPa (2 psi). A description of the operating characteristics and instrumentation used for pressure, frequency, and displacement measurements is given. The pressure generator was used to statically and dynamically calibrate transducers. Test results demonstrated that a difference an exist between the static and dynamic sensitivity of a transducer, confirming the need for dynamic calibrations of in situ pressure transducers.

Bolt, P. A.↗

Calibration of high-temperature, fiber-optic, microbend, pressure transducers

The microbend pressure transducer was evaluated on the basis of a series of specified tests to determine the pressure, temperature, overpressure, and vibration response. The response was found to be approximately linear with a pressure in the range of -690 to + 690 kPa. The transducer exhibited high sensitivity to diaphragm deflection and rapid response to pressure changes and was insensitive to vibration for frequencies of 50 to 2500 Hz. The microbend transducer test data showed acceptable sensitivity and stability as a function of temperature and pressure to be used as the basis for a compensatable transducer.

Berthold, J. W.↗

Transducer-Mounting Fixture

Transducer-mounting fixture holds transducer securely against stud. Projects only slightly beyond stud after installation. Flanged transducer fits into fixture when hinged halves open. When halves reclosed, fixture tightened onto threaded stud until stud makes contact with transducer. Knurled area on fixture aids in tightening fixture on stud.

Spiegel, Kirk W.↗

Development of a tethered satellite force transducer

The SEDS (Small Expendable Deployer System)/Delta II is a demonstration flight of a tethered satellite deployer system. The satellite or end mass payload, which is deployed and tethered to the Delta II rocket, is instrumented to determine its dynamics during deployment. A three-component force transducer or strain-gage balance was developed to measure tether tension on the end-mass side of the tether. The transducer was designed to measure tensions up to 20N in each direction and resolve tensions as low as 0.002N. In addition, the transducer was required to withstand the shock, vibration, and temperature excursions of the mission. The development of the transducer from design to testing and integration is discussed.

Rhew, Ray D.↗

Pressure Transducer Remote Calibration/Health Check

This presentation reports on efforts to develop an in-situ pressure transducer calibration system for extension of calibration lifecycle and transducer health determination. This system aims to: (1) provide a long term solution to determining the calibration of pressure transducers for gas applications, (2) provide a method of isolating problems in remote measurements, and (3) reduce costs and resources by extending the length of time a transducer may be left in a system without a repeat laboratory calibration. Topic covers include: design requirements, design assumptions and design approach.

Deyoe, Richard↗

Statistical Characterization of Environmental Error Sources Affecting Electronically Scanned Pressure Transducers

Minimization of uncertainty is essential to extend the usable range of the 15-psid Electronically Scanned Pressure (ESP) transducer measurements to the low free-stream static pressures found in hypersonic wind tunnels. Statistical characterization of environmental error sources inducing much of this uncertainty requires a well defined and controlled calibration method. Employing such a controlled calibration system, several studies were conducted that provide quantitative information detailing the required controls needed to minimize environmental and human induced error sources. Results of temperature, environmental pressure, over-pressurization, and set point randomization studies for the 15-psid transducers are presented along with a comparison of two regression methods using data acquired with both 0.36-psid and 15-psid transducers. Together these results provide insight into procedural and environmental controls required for long term high-accuracy pressure measurements near 0.01 psia in the hypersonic testing environment using 15-psid ESP transducers.

Green, Del L.↗

Statistical Characterization of Environmental Error Sources Affecting Electronically Scanned Pressure Transducers

Minimization of uncertainty is essential to extend the usable range of the 15-psid Electronically Scanned Pressure [ESP) transducer measurements to the low free-stream static pressures found in hypersonic wind tunnels. Statistical characterization of environmental error sources inducing much of this uncertainty requires a well defined and controlled calibration method. Employing such a controlled calibration system, several studies were conducted that provide quantitative information detailing the required controls needed to minimize environmental and human induced error sources. Results of temperature, environmental pressure, over-pressurization, and set point randomization studies for the 15-psid transducers are presented along with a comparison of two regression methods using data acquired with both 0.36-psid and 15-psid transducers. Together these results provide insight into procedural and environmental controls required for long term high-accuracy pressure measurements near 0.01 psia in the hypersonic testing environment using 15-psid ESP transducers.

Green, Del L.↗

Micromachined Tunneling Displacement Transducers for Physical Sensors

We have designed and constructed a series of tunneling sensors which take advantage of the extreme position sensitivity of electron tunneling. In these sensors, a tunneling displacement transducer, based on scanning tunneling microscopy principles, is used to detect the signal-induced motion of a sensor element. Through the use of high-resonant frequency mechanical elements for the transducer, sensors may be constructed which offer wide bandwidth, and are robust and easily operated. Silicon micromachining may be used to fabricate the transducer elements, allowing integration of sensor and control electronics. Examples of tunneling accelerometers and infrared detectors will be discussed. In each case, the use of the tunneling transducer allows miniaturization of the sensor as well as enhancement of the sensor performance.

Kenny, T. W.↗

Oscillation pressure device for dynamic calibration of pressure transducers

Method and apparatus for obtaining dynamic calibrations of pressure transducers. A calibration head (15), a flexible tubing (23) and a bellows (20) enclose a volume of air at atmospheric pressure with a transducer (11) to be calibrated subject to the pressure inside the volume. All of the other apparatus in the drawing apply oscillations to bellows (20) causing the volume to change thereby applying oscillating pressures to transducer (11) whereby transducer (11) can be calibrated.

Hess, Robert W.↗

Performance Evaluation of Pressure Transducers for Water Impacts

The Orion Multi-Purpose Crew Vehicle is being designed for water landings. In order to benchmark the ability of engineering tools to predict water landing loads, test programs are underway for scale model and full-scale water impacts. These test programs are predicated on the reliable measurement of impact pressure histories. Tests have been performed with a variety of pressure transducers from various manufacturers. Both piezoelectric and piezoresistive devices have been tested. Effects such as thermal shock, pinching of the transducer head, and flushness of the transducer mounting have been studied. Data acquisition issues such as sampling rate and anti-aliasing filtering also have been studied. The response of pressure transducers have been compared side-by-side on an impulse test rig and on a 20-inch diameter hemisphere dropped into a pool of water. The results have identified a range of viable configurations for pressure measurement dependent on the objectives of the test program.

Vassilakos, Gregory J.↗

Design Process of a Pressure Transducer Vibration Fixture

This paper details the iterative design cycle of a fixture used to mount two types of pressure transducers for vibration testing which allows for functional testing without the removal of the transducers. The objective of the fixture is to prove that the pressure transducers can survive vibrations induced during launch. This would increase the Technology Readiness Level of the pressure transducers which is a requirement for the Lunar Advanced Volatile Analysis subsystem preliminary design review. During the design process, additive manufacturing is considered as a manufacturing method of the fixture as a way to investigate the use of additive manufacturing for the final flight version of the Fluid Sub System manifold. It is ultimately shown that the added ability to perform functional testing and optimization for additive manufacturing made the fixture less than ideal for vibration testing. It is determined that the best option is to design and manufacture a traditional vibration fixture without the ability to perform functional testing of components while attached and a separate part to investigate the application of additive manufacturing to the Fluid Subsystem manifold.

Gilstrap, Andrew↗

Characterization of Transducers and Resonators under High Drive Levels

In many applications, piezoelectric transducers are driven at AC voltage levels well beyond the level for which the material was nominally characterized. In this paper we describe an experimental setup that allows for the determination of the main transducer or resonator properties under large AC drive. A sinusoidal voltage from a waveform generator is amplified and applied across the transducer/resonator in series with a known high power resistor. The amplitude of applied voltage and the amplitude and the relative phase of the current through the resistor are monitored on a digital scope. The frequency of the applied signal is swept through resonance and the voltage/current signals are recorded. After corrections for the series resistance and parasitic elements the technique allows for the determination of the complex impedance spectra of the sample as a function of frequency. In addition, access to the current signal allows for the direct investigation of non-linear effects through the application of Fourier transform techniques on the current signal. Our results indicate that care is required when interpreting impedance data at high drive level due to the frequency dependence of the dissipated power. Although the transducer/resonator at a single frequency and after many cycles may reach thermal equilibrium, the spectra as a whole cannot be considered an isothermal measurement due to the temperature change with frequency. Methods to correct for this effect will be discussed. Results determined from resonators of both soft and hard PZT and a ultrasonic horn transducer are presented.

transducers↗

Cryogenic pressure transducer

Cryogenic pressure transducer utilizes a diaphragm which is electron beam welded to a fitting. This assembly is then heliarc welded to the main body of the transducer. The transducer requires no damping oil and thus is capable of operating at both cryogenic and high temperatures.

Hendrix, J. M.↗

Transducer applications, a compilation

The characteristics and applications of transducers are discussed. Subjects presented are: (1) thermal measurements, (2) liquid level and fluid flow measurements, (3) pressure transducers, (4) stress-strain measurements, (5) acceleration and velocity measurements, (6) displacement and angular rotation, and (7) transducer test and calibration methods.

Source record↗

Development of piezoelectric skin friction force vector transducer for a hypersonic wind tunnel

A surface shear force transducer for use in impulse type hypersonic tunnels is described. Sensors are constructed of lead zirconate titanate composition piezoelectric ceramic materials. The diameter of the sensing diaphragm is 0.75 inches and overall transducer dimensions are 1.0 inch diameter and 0.625 inch height. Analysis of the tranducer is made to help design criteria and fabrication techniques. Discussions on design and fabrication techniques are presented as well as performance of transducers delivered.

Kahng, S. K.↗

A proposed magnetic digital temperature transducer, volume 1

A study has been made of the feasibility of using the discontinuous permeability versus temperature characteristics of some magnetic materials for a digital temperature transducer and a thermally controlled ON-OFF switch. Simple logic converts the number of output pulse to a digital word recognizable by the system. Efforts have been concentrated on materials with Curie temperatures between 0 and 100 C. One compound has the composition Mn(5-x)Fe(x)Ge3 where the amount of iron determines the transition temperature. The other compound is Ni-Zn ferrite and has the compositon Ni(1-x)Zn(x)Fe(1.95)O4 where the nickel: zinc ratio determines the transition temperature. A detailed report of materials prepared is presented. Toroidal inductors of the material have been constructed and the change in inductance with temperature measured. In view of these initial measurements, it is felt that a transducer utilizing the permeability versus temperature characteristics of these materials has promise as a reliable and sensitive solid state digital temperature transducer.

Collier, T. E.↗

Acoustical transducer calibrating system and apparatus

An acoustical transducer calibrating system includes a differential pressure actuating device having an inner chamber for applying differential pressures to the transducer, and an outer chamber for vacuum sealing. Mounted within the inner chamber is an electrostatic actuator for exciting the transducer at selected frequencies so that its sensitivity can be determined for different operating ambient pressures.

Lewis, T. L.↗