Local probing of relaxation time distributions in ferroelectric polymer nanomesas: Time-resolved piezoresponse force spectroscopy and spectroscopic imaging

Time-resolved piezoresponse force spectroscopy (TR-PFS) and spectroscopic imaging are developed to probe the spatial variability of relaxation behavior in nanoscale ferroelectric materials and structures. TR-PFS was applied to study polarization dynamics in polyvinylidine fluoride and trifluoroethylene nanomesas. We demonstrate that polarization relaxation in ferroelectric polymers is slow even on the 10 nm length scale of piezoresponse force microscopy (PFM) signal generation. Furthermore, the relaxation times are found to be nonuniform within the nanomesa, indicative of a complex internal structure. The applicability of TR-PFM for studies of polarization dynamics in ferroelectric polymers and relaxors is discussed.

Rodriguez, Brian↗

Time-resolved Chemical Imaging of Molecules by High-order Harmonics and Ultrashort Rescattering Electrons

Directly monitoring atomic motion during a molecular transformation with atomic-scale spatio-temporal resolution is a frontier of ultrafast optical science and physical chemistry. Here we provide the foundation for a new imaging method, fixed-angle broadband laser-induced electron scattering, based on structural retrieval by direct one-dimensional Fourier transform of a photoelectron energy distribution observed along the polarization direction of an intense ultrafast light pulse. The approach exploits the scattering of a broadband wave packet created by strong-field tunnel ionization to self-interrogate the molecular structure with picometre spatial resolution and bond specificity. With its inherent femtosecond resolution, combining our technique with molecular alignment can, in principle, provide the basis for time-resolved tomography for multi-dimensional transient structural determination.

74 ATOMIC AND MOLECULAR PHYSICS↗

A 25 micron-thin microscope for imaging upconverting nanoparticles with NIR-I and NIR-II illumination

Rationale: Intraoperative visualization in small surgical cavities and hard-to-access areas are essential requirements for modern, minimally invasive surgeries and demand significant miniaturization. However, current optical imagers require multiple hard-to-miniaturize components including lenses, filters and optical fibers. These components restrict both the form-factor and maneuverability of these imagers, and imagers largely remain stand-alone devices with centimeter-scale dimensions. Methods: We have engineered INSITE (Immunotargeted Nanoparticle Single-Chip Imaging Technology), which integrates the unique optical properties of lanthanide-based alloyed upconverting nanoparticles (aUCNPs) with the time-resolved imaging of a 25-micron thin CMOS-based (complementary metal oxide semiconductor) imager. We have synthesized core/shell aUCNPs of different compositions and imaged their visible emission with INSITE under either NIR-I and NIR-II photoexcitation. We characterized aUCNP imaging with INSITE across both varying aUCNP composition and 980 nm and 1550 nm excitation wavelengths. To demonstrate clinical experimental validity, we also conducted an intratumoral injection into LNCaP prostate tumors in a male nude mouse that was subsequently excised and imaged with INSITE. Results: Under the low illumination fluences compatible with live animal imaging, we measure aUCNP radiative lifetimes of 600 μs - 1.3 ms, which provides strong signal for time-resolved INSITE imaging. Core/shell NaEr 0.6 Yb 0.4 F 4 aUCNPs show the highest INSITE signal when illuminated at either 980 nm or 1550 nm, with signal from NIR-I excitation about an order of magnitude brighter than from NIR-II excitation. The 55 μm spatial resolution achievable with this approach is demonstrated through imaging of aUCNPs in PDMS (polydimethylsiloxane) micro-wells, showing resolution of micrometer-scale targets with single-pixel precision. INSITE imaging of intratumoral NaEr 0.8 Yb 0.2 F 4 aUCNPs shows a signal-to-background ratio of 9, limited only by photodiode dark current and electronic noise. Conclusion: This work demonstrates INSITE imaging of aUCNPs in tumors, achieving an imaging platform that is thinned to just a 25 μm-thin, planar form-factor, with both NIR-I and NIR-II excitation. Based on a highly paralleled array structure INSITE is scalable, enabling direct coupling with a wide array of surgical and robotic tools for seamless integration with tissue actuation, resection or ablation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On the plume splitting of pulsed laser ablated Fe and Al plasmas

A time resolved imaging study of pulsed laser ablated Fe and Al plasma plumes with specific interest in the splitting of plumes into the slow and fast moving components as they expand through the background argon gas at different pressures is reported. The material ablation was achieved using a Q-switched Nd:YAG (yttrium aluminum garnet) laser operating at 532 nm with a pulse duration of {approx}8 ns full width at half maximum and a fluence of 30 Jcm{sup -2} at the target surface. Typical time resolved images with low magnification show that the splitting occurs at moderate background gas pressures (0.5 and 1.0 mbar for Fe, and 0.2 mbar for Al plasma plumes). The plume splitting did not occur for higher background gas pressures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Kinetics and Mechanisms of ZnO to ZIF-8 Transformations in Supercritical CO2 Revealed by in situ X-ray Diffraction

ZIF-8 was synthesized in supercritical carbon dioxide (scCO2). In situ powder X-ray diffraction, ex situ microscopy and simulations, provides a encompassing view of the formation of ZIF-8 and intermediary ZnO@ZIF-8 composites in this nontraditional solvent. Time-resolved imaging exposed divergent physicochemical reaction pathways from previous studies of the growth of anisotropic ZIF-8 core@shell structures in traditional solvents. Synthetically relevant physio-chemical properties of scCO2 were integrated into classical nucleation theory, relating interfacial forces with 3D nu-cleation outcomes. The kinetics of crystallization were examined and displayed a characteristic signature of time- and temperature-dependent mechanisms over the extent of the reaction. Lastly, we show that subtle factors, such as the extent of reaction and the size/shape of sacrificial templates can tailor ZIF-8 composition and size, eliciting control over hierarchical porosity in a nonconventional green solvent.

Sinnwell, Michael A.↗

Time-resolved ion imaging at free-electron lasers using TimepixCam

In this paper, the application of a novel fast optical-imaging camera, TimepixCam, to molecular photoionization experiments using the velocity-map imaging technique at a free-electron laser is described. TimepixCam is a 256 × 256 pixel CMOS camera that is able to detect and time-stamp ion hits with 20 ns timing resolution, thus making it possible to record ion momentum images for all fragment ions simultaneously and avoiding the need to gate the detector on a single fragment. This allows the recording of significantly more data within a given amount of beam time and is particularly useful for pump–probe experiments, where drifts, for example, in the timing and pulse energy of the free-electron laser, severely limit the comparability of pump–probe scans for different fragments taken consecutively. Finally, in principle, this also allows ion–ion covariance or coincidence techniques to be applied to determine angular correlations between fragments.

47 OTHER INSTRUMENTATION↗

Time-Resolved Neutron Imaging for Hydrogen Uptake in Subsurface Lithologies

Geologic hydrogen production and underground storage are increasingly important for meeting rising energy demands while providing clean-combustion advantages. However, hydrogen’s high diffusivity and propensity for leakage through porous media necessitate direct evaluation of its transport behavior in subsurface materials. Whereas X-ray microcomputed tomography (μCT) studies often employ contrast agents or surrogate gases, this study leverages neutron transmission radiography/CT to observe hydrogen migration in situ. This work represents the first demonstration of real-time neutron radiography of hydrogen migration in reservoir and caprock lithologies. Cylindrical cores of Indiana limestone, Amherst Gray sandstone, and Tumey shale were subjected to constant-pressure hydrogen charging and scanned in real time using high-resolution neutron radiography. Results indicate immediate hydrogen infiltration in sandstone and limestone, with homogeneous distribution detected throughout their pore structure. In contrast, hydrogen remained largely absent from fine-grained shale under the same pressure, except in an apparently localized fracture zone, where neutron signatures confirmed the presence of hydrogen. Subsequent neutron CT of the sandstone sample, using image subtraction against an uncharged reference, corroborated hydrogen distribution patterns. Even under lowpressure, single-phase conditions, distinct neutron imaging signatures of hydrogen were achieved. These preliminary findings underscore the potential of neutron imaging for advancing subsurface hydrogen migration research.

08 HYDROGEN↗

Time-resolved chemical imaging based on stimulated TERS (Final Scientific-Technical Report-Phase-II-DE-SC0013172)

This is the Final Scientific/Technical Report for the DOE FastTrack SBIR Grant from Fiscal Year 2015. The report details the work pursued to scientifically demonstrate ultrahigh spatial resolution in ultrafast spectroscopy and commercially develop a product offering that provides the similar capability to other researchers. Chemical and electronic information associated with molecular-scale processes can be interrogated via optical spectroscopy. By utilizing two ultrafast lasers, one to “pump” and the other to “probe” with time delay between them, researchers are able to study various molecular and electronic dynamics with time resolution in femtosecond range. Due to the diffraction limit associated with these optical techniques, these techniques measure average behavior of ensemble of molecules since individual molecules are typically much smaller than the wavelengths of the lasers being utilized. This report presents the successful demonstration of ultrafast spectroscopy (temporal resolution of 150 femtosecond limited by the laser pulse width) of electronic recovery in carbon nanotubes, revealing different recovery dynamics for individual carbon nanotubes with spatial resolution of ~ 10 nm, more than 50X smaller than the wavelengths used to study them. The report also details the required instrumentation for such measurements and how it plans to offer a turnkey solution to the research community to provide such capability in a user-friendly and low maintenance package.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time Resolved Particle Image Velocimetry in Nozzle Flow

Temporally resolved particle image velocimetry (TR-PIV) is the newest and most exciting tool recently developed to support our continuing efforts to characterize and improve our understanding of the decay of turbulence in jet flows—a critical element for understanding the acoustic properties of the flow. A new TR-PIV system has been developed at the NASA Glenn Research Center which is capable of acquiring planar PIV image frame pairs at up to 25 kHz. The data reported here were collected at Mach numbers of 0.5 and 0.9 and at temperature ratios of 0.89 and 1.76. The field of view of the TR-PIV system covered six nozzle diameters along the lip line of the 50.8 mm diameter jet. The cold flow data at Mach 0.5 were compared with hotwire anemometry measurements in order to validate the new TR-PIV technique. The axial turbulence profiles measured across the shear layer using TR-PIV were thinner than those measured using hotwire anemometry and remained centred along the nozzle lip line. The collected TR-PIV data illustrate the differences in the single point statistical flow properties of cold and hot jet flows. The planar, time-resolved velocity records were then used to compute two-point space–time correlations of the flow at the Mach 0.9 flow condition. The TR-PIV results show that there are differences in the convective velocity and growth rate of the turbulent structures between cold and hot flows at the same Mach number.

Temporally Resolved Particle Image Velocimetry↗

Time-resolved particle image velocimetry measurements of the turbulent Richtmyer–Meshkov instability

Experiments are presented on the Richtmyer–Meshkov instability (RMI) with a three-dimensional, multi-mode initial perturbation. The experiments use a vertical shock tube, where a stably stratified interface is formed between air and sulphur hexafluoride (SF 6 ) via counterflow. A perturbation is imposed at the interface by vertical oscillation of the gas column, forming Faraday waves. The interface is accelerated by a Mach 1.17 (in air) shock wave, and the development of the mixing region between the gases is investigated using particle image velocimetry. Following shock acceleration, a reflected shock wave from the bottom of the shock tube interacts with the mixing layer a second time (reshock). The experiment is initialized with both high and low amplitude perturbations to examine the effect of the perturbation amplitude on measured quantities. The instability growth exponent (θ) is determined from the kinetic energy field using the width of the mixing layer and the decay of kinetic energy, which are found to be in agreement when the flow is most strongly excited. A growth exponent of θ ≈ 0.5 is found for all cases except the high-amplitude reshocked regime (where θ ≈ 0.33). High-amplitude experiments exhibit the transitional outer Reynolds number (Re ≡ hh˙/ν >10 4 ) required for mixing transition following the incident shock, and both experiments are elevated well above this threshold following reshock. However, neither set of experiments meet the more stringent requirements proposed by Zhou et al. (Phys. Rev.E, vol. 67, issue 5, 2003) which include the time dependent aspect of the RMI, an observation which is also made when examining the spectra.

42 ENGINEERING↗

Two-dimensional burn velocity and analysis of burn products of nitromethane at high pressure

We have studied the laser-initiated deflagration of nitromethane (CH 3 NO 2 ) under high static pressure in the diamond anvil cell. Time-resolved images of the deflagrations have been obtained using intensified CCDs (ICCD). In contrast with previous work, we rely on spontaneous emission from the reaction, rather than changes in the speckle pattern produced by artificial illumination of the sample. Furthermore, as opposed to the 1D records obtained previously with streak cameras, ICCDs permit imaging of the burn in two dimensions providing the ability to directly observe anisotropic deflagration behavior. Here, we report several examples of this behavior and discuss its possible origins. We have also investigated the products of the reaction using Raman spectroscopy. At pressures below 25 GPa, the burn product is observed to be opaque and has a Raman spectrum consistent with a carbonaceous soot. At pressures above 25 GPa, the burn product is observed to be transparent (consistent with earlier reports) and its Raman spectrum reveals the presence of molecular N 2 and a nitrogen-carbonate species. The latter species can be recovered to ambient pressure and has a Raman spectrum consistent with ammonium carbonate or ammonium bicarbonate. To aid interpretation of the Raman spectra, measurements have also been made on the isotopologues CH 3 15 NO 2 and 13 CH 3 NO 2 . This work establishes the importance of advanced time-resolved imaging to reveal the details of deflagration under high pressure and further advances our understanding of the corresponding chemistry.

Deflagration↗

Efficient laser-induced 6-8 keV x-ray production from iron oxide aerogel and foil-lined cavity targets

The performance of new iron-based laser-driven x-ray sources has been tested at the OMEGA laser facility for production of x rays in the 6.5-8.5 keV range. Two types of targets were experimentally investigated: low-density iron oxide aerogels (density 6-16 mg/cm{sup 3}) and stainless steel foil-lined cavity targets (steel thickness 1-5 {mu}m). The targets were irradiated by 40 beams of the OMEGA laser (500 J/beam, 1 ns pulse, wavelength 351 nm). All targets showed good coupling with the laser, with <5% of the incident laser light backscattered by the resulting plasma in all cases (typically <2.5%). The aerogel targets produced T{sub e}=2 to 3 keV, n{sub e}=0.12-0.2 critical density plasmas yielding a 40%-60% laser-to-x-ray total conversion efficiency (CE) (1.2%-3% in the Fe K-shell range). The foil cavity targets produced T{sub e}{approx} 2 keV, n{sub e}{approx} 0.15 critical density plasmas yielding a 60%-75% conversion efficiency (1.6%-2.2% in the Fe K-shell range). Time-resolved images illustrate that the volumetric heating of low-density aerogels allow them to emit a higher K-shell x-ray yield even though they contain fewer Fe atoms. However, their challenging fabrication process leads to a larger shot-to-shot variation than cavity targets.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Kinetics of liquid-mediated crystallization of amorphous Ge from multi-frame dynamic transmission electron microscopy

The kinetics of laser-induced, liquid-mediated crystallization of amorphous Ge thin films were studied using multi-frame dynamic transmission electron microscopy (DTEM), a nanosecond-scale photo-emission transmission electron microscopy technique. In these experiments, high temperature gradients are established in thin amorphous Ge films with a 12-ns laser pulse with a Gaussian spatial profile. The hottest region at the center of the laser spot crystallizes in ~100 ns and becomes nano-crystalline. Over the next several hundred nanoseconds crystallization continues radially outward from the nano-crystalline region forming elongated grains, some many microns long. The growth rate during the formation of these radial grains is measured with time-resolved imaging experiments. Crystal growth rates exceed 10 m/s, which are consistent with crystallization mediated by a very thin, undercooled transient liquid layer, rather than a purely solid-state transformation mechanism. The kinetics of this growth mode have been studied in detail under steady-state conditions, but here we provide a detailed study of liquid-mediated growth in high temperature gradients. Unexpectedly, the propagation rate of the crystallization front was observed to remain constant during this growth mode even when passing through large local temperature gradients, in stark contrast to other similar studies that suggested the growth rate changed dramatically. As a result, the high throughput of multi-frame DTEM provides gives a more complete picture of the role of temperature and temperature gradient on laser crystallization than previous DTEM experiments.

36 MATERIALS SCIENCE↗

Ultra-Fast Electron Microscopic Imaging of Single Molecules With a Direct Electron Detection Camera and Noise Reduction

Time-resolved imaging of molecules and materials made of light elements is an emerging field of transmission electron microscopy (TEM), and the recent development of direct electron detection cameras, capable of taking as many as 1,600 fps, has potentially broadened the scope of the time-resolved TEM imaging in chemistry and nanotechnology. However, such a high frame rate reduces electron dose per frame, lowers the signal-to-noise ratio (SNR), and renders the molecular images practically invisible. Here, we examined image noise reduction to take the best advantage of fast cameras and concluded that the Chambolle total variation denoising algorithm is the method of choice, as illustrated for imaging of a molecule in the 1D hollow space of a carbon nanotube with ~1 ms time resolution. Through the systematic comparison of the performance of multiple denoising algorithms, we found that the Chambolle algorithm improves the SNR by more than an order of magnitude when applied to TEM images taken at a low electron dose as required for imaging at around 1,000 fps. Open-source code and a standalone application to apply Chambolle denoising to TEM images and video frames are available for download.

47 OTHER INSTRUMENTATION↗