Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Time Service”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Clock Synchronization in High-end Computing Environments: A Strategy for Minimizing Clock Variance at Runtime

We present a new software-based clock synchronization scheme that provides high precision time agreement among distributed memory nodes. The technique is designed to minimize variance from a reference chimer during runtime and with minimal time-request latency. Our scheme permits initial unbounded variations in time and corrects both slow and fast chimers (clock skew). An implementation developed within the context of the MPI message passing interface is described, and time coordination measurements are presented. Among our results, the mean time variance for a set of nodes improved from 20.0 milliseconds under standard Network Time Protocol (NTP) down to 2.29 secs under our scheme.

clock synchronization↗

An evaluation of the state of time synchronization on leadership class supercomputers

We present a detailed examination of time agreement characteristics for nodes within extreme-scale parallel computers. Using a software tool we introduce in this paper, we quantify attributes of clock skew among nodes in three representative high-performance computers sited at three national laboratories. Our measurements detail the statistical properties of time agreement among nodes and how time agreement drifts over typical application execution durations. We discuss the implications of our measurements, why the current state of the field is inadequate, and propose strategies to address observed shortcomings.

97 MATHEMATICS AND COMPUTING↗

Life cycle assessment of railway ties fabricated with ductile cementitious composites and carbonation curing

This paper evaluates the lifecycle economic and environmental benefits of implementing CO 2 utilization and storage within advanced engineered cementitious composite (ECC) railway ties. Using CO 2 -treated ECC ties can yield lifecycle benefits primarily due to enhanced material properties – increased lifespan in this case – instead of due to the stored CO 2 that would otherwise enter the atmosphere. Sequestration-based policies such as 45Q in the United States would therefore not incentivize deployment of ECC railway ties, despite their considerable CO 2 avoidance opportunities. To reach these conclusions, cradle-to-grave lifecycle models were developed for ECC ties and conventional concrete ties and evaluated under 1000 possible use-phase scenarios. The models incorporated premature tie failures – consistent with real-world observations – that were used to study a wide range of non-linear impacts arising from the random nature of tie failures and replacements. The results show that past studies that neglected premature failure of ties may have underestimated lifecycle greenhouse gas (GHG) emissions of concrete rail ties by nearly three times. Overall, servicing a track with ECC ties instead of concrete ties can reduce the lifecycle costs and GHG emissions by 12% and 21% respectively, based on median values of 1000 model run results. The expected benefits would be larger for entities like Amtrak that plan to expand concrete tie infrastructure despite significant challenges with premature concrete tie failures. Furthermore, the results of this study suggest that the lifespan of ECC ties needs to be at least 25% longer than concrete ties to achieve net lifecycle benefits. The possibility of this should be tested and confirmed under real-world conditions.

42 ENGINEERING↗

Hydropower operation in future power grid with various renewable power integration

Hydropower generation may play an increasingly important role in the power grid under increasing contribution of variable renewable sources such as wind and solar. An improved understanding of the changes to hydropower dispatch under future higher VRE grid conditions reveals research gap that should be informed power grid planning and reservoir water releases policies considering multiple other water uses and varying hydrologic condition. Here this study aims to understand the role of hydropower in a changing power grid by employing a production cost model, PLEXOS, across future power system scenarios, planning horizons, and regions. We explore optimized hydropower dispatch to understand its potential role in minimizing the system cost and renewable curtailment. We also examine the sensitivity of hydropower revenue under various grid scenarios of the Eastern U.S. and hydrology conditions. Results indicate hydropower generation follows net load and compensates for the variability of solar and wind generation. Although energy prices are lower during some periods in the future grid scenarios, there is a potential for higher revenue for hydropower by providing both energy and ancillary services during times of stress. Additionally, hydropower revenue is sensitive to hydrology in the SERC region, which we considered as an example. The feasibility of hydropower dispatching with higher ramps between low and high hourly-capacity factors, as indicated in the optimization model, requires further study to consider other water use and ecology constraints.

13 HYDRO ENERGY↗

Resilient Information Architecture Platform for the Smart Grid (RIAPS): A Novel Open-Source Platform for Microgrid Control

Microgrids are seen as an effective way to achieve reliable, resilient, and efficient operation of the power distribution system. Core functions of the microgrid control system are defined by the IEEE standard 2030.7; however, the algorithms that realize these functions are not standardized, and are a topic of research. Furthermore, the corresponding controller hardware, operating system, and communication system to implement these functions vary significantly from one implementation to the next. In this paper, we introduce an open-source platform, Resilient Information Architecture Platform for the Smart Grid (RIAPS), ideally suited for implementing and deploying distributed microgrid control algorithms. RIAPS provides a design-time tool suite for development and deployment of distributed microgrid control algorithms. With support from a number of run-time platform services, developed algorithms can be easily implemented and deployed into real microgrids. To demonstrate the unique features of RIAPS, we propose and implement a distributed microgrid secondary control algorithm capable of synchronized and proportional compensation of voltage unbalance using distributed generators. In conclusion, test results show the effectiveness of the proposed control and the salient features of the RIAPS platform.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Clock Agreement Among Parallel Supercomputer Nodes

This dataset presents measurements that quantify the clock synchronization time-agreement characteristics among several high performance computers including the current world's most powerful machine for open science, the U.S. Department of Energy's Titan machine sited at Oak Ridge National Laboratory. These ultra-fast machines derive much of their computational capability from extreme node counts (over 18000 nodes in the case of the Titan machine). Time-agreement is commonly utilized by parallel programming applications and tools, distributed programming application and tools, and system software. Our time-agreement measurements detail the degree of time variance between nodes and how that variance changes over time. The dataset includes empirical measurements and the accompanying spreadsheets.

97 MATHEMATICS AND COMPUTING↗

Marine Corps Base Camp Lejeune - Forest Burn Data

Critical military training and testing on lands along the nation’s coastal and estuarine shorelines are increasingly placed at risk because of encroachment pressures in surrounding areas, impairments due to other anthropogenic disturbances, and changes in climate and sea level. The U.S. Department of Defense (DoD) intends to enhance and sustain its training and testing assets and also optimize its stewardship of natural resources through the development and application of an ecosystem-based management approach on DoD installations. To accomplish this goal, particularly for installations in estuarine/coastal environments, the Strategic Environmental Research and Development Program (SERDP) launched the Defense Coastal/Estuarine Research Program (DCERP) as a 10-year effort at Marine Corps Base Camp Lejeune (MCBCL) in North Carolina. The results of the second 5 years of the program (DCERP2) are presented in the DCERP2 Final Report.There were four overarching objectives of DCERP2. The first objective was to understand the effects of climate change impacts, including warming temperatures, variability in the hydrological cycle, storm events, and sea level rise on the coastal ecosystems at MCBCL from observations and measurements made over the 10-year program. The second objective was to understand the carbon cycle of the coastal and terrestrial ecosystems at MCBCL through a highly integrated sampling program. The third objective was to develop models, tools, and indicators to evaluate current and projected future ecosystem state changes and translate scientific findings into actionable information for installation managers. The last objective was to recommend adaptive management strategies to sustain ecosystem natural resources within the context of an active military installation.This data package contains burn and wildfire history and time enabled service data.

54 ENVIRONMENTAL SCIENCES↗

Flow Battery System Design for Manufacturability.

Flow battery energy storage systems can support renewable energy generation and increase energy efficiency. But, presently, the costs of flow battery energy storage systems can be a significant barrier for large-scale market penetration. For cost- effective systems to be produced, it is critical to optimize the selection of materials and components simultaneously with the adherence to requirements and manufacturing processes to allow these batteries and their manufacturers to succeed in the market by reducing costs to consumers. This report analyzes performance, safety, and testing requirements derived from applicable regulations as well as commercial and military standards that would apply to a flow battery energy storage system. System components of a zinc-bromine flow battery energy storage system, including the batteries, inverters, and control and monitoring system, are discussed relative to manufacturing. The issues addressed include costs and component availability and lead times. A service and support model including setup, maintenance and transportation is outlined, along with a description of the safety-related features of the example flow battery energy storage system to promote regulatory and environmental, safety, and health compliance in anticipation of scale manufacturing.

Montoya, Tracy Louise↗

Light Water Reactor Sustainability Program: Evaluation of Localized Cable Test Methods for Nuclear Power Plant Cable Aging Management Programs

This Pacific Northwest National Laboratory (PNNL) milestone report describes progress to date on the investigation of nondestructive test (NDE) methods focusing particularly on local measurements that provide key indicators of cable aging and damage. The work includes a review of relevant literature as well as hands-on experimental verification of inspection capabilities. As NPPs consider applying for second, or subsequent, license renewal (SLR) to extend their operating period from 60 years to 80 years, it important to understand how the materials installed in plant systems and components will age during that time and develop aging management programs (AMPs) to assure continued safe operation under normal and design basis events (DBE). Normal component and system tests typically confirm the cables can perform their normal operational function. The focus of the cable test program is directed toward the more demanding challenge of assuring the cable function under accident or DBE. Most utilities already have a program associated with their first life extension from 40 to 60 years. Regrettably, there is neither a clear guideline nor a single NDE that can assure cable function and integrity for all cables. Thankfully, however, practical implementation of a broad range of tests allows utilities to develop a practical program that assures cable function to a high degree. The industry has adopted 50% elongation at break (EAB) relative to the un-aged cable condition as the acceptability standard. All tests are benchmarked against the cable EAB test. EAB is a destructive test so the test programs must apply an array of other NDE tests to assure or infer the overall set of cable’s system integrity. These cable NDE programs vary in rigor and methodology. As the industry gains experience with the efficacy of these programs, it is expected that implementation practice will converge to a more common approach. This report addresses the range of local NDE cable tests that are or could be practically implemented in a field test situation. These tests include: visual, infrared thermography, interdigital capacitance, indenter, relaxation time indenter, dynamic mechanical analyzer, infrared/near-infrared spectrometry, ultrasound, and distributed fiber optic temperature measurement.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Modeling Air Pollutant Emissions in the Provincial Level Road Transportation Sector in Korea: A Case Study of the Zero-Emission Vehicle Subsidy

South Korea has been suffering from high PM2.5 pollution. Previous studies have contributed to establishing PM2.5 mitigation policies but have not considered provincial features and sector-interactions. In that sense, the integrated assessment model (IAM) could complement the shortcomings of previous studies. IAM, capable of analyzing PM2.5 pollution levels at the provincial level in Korea, however, has not been developed yet. Hence, this study (i) expands on IAM which can represent provincial-level spatial resolution in Korea (GCAM-Korea) with air pollutant emissions modeling which focuses on the road transportation sector and (ii) examines the zero-emission vehicles (ZEVs) subsidy policy’s effects on PM2.5 mitigation using the expanded GCAM-Korea. Simulation results show that PM2.5 emissions decrease by 0.6–4.1% compared to the baseline, and the Seoul metropolitan area contributes 38–44% to the overall PM2.5 emission reductions. As the ZEVs subsidy is weighted towards the light-duty vehicle 4-wheels (LDV4W) sector, various spillover effects are found: ZEVs’ share rises intensively in the LDV4W sector leading to an increase in its service costs, and at the same time, driving bus service costs to become relatively cheaper. This, in turn, drives an increase in bus service demand and emissions discharge. Furthermore, this type of impact of the ZEVs subsidy policy does not reduce internal combustion engine vehicles (ICEVs) in freight trucks, although diesel freight trucks are a major contributor to PM2.5 emissions and also to NOx.

Roh, Minyoung↗

Role of Standard Demand Response Signals for Advanced Automated Aggregation

Emerging standards such as OpenADR enable Demand Response (DR) Resources to interact directly with Utilities and Independent System Operators to allow their facility automation equipment to respond to a variety of DR signals ranging from day ahead to real time ancillary services. In addition, there are Aggregators in today’s markets who are capable of bringing together collections of aggregated DR assets and selling them to the grid as a single resource. However, in most cases these aggregated resources are not automated and when they are, they typically use proprietary technologies. There is a need for a framework for dealing with aggregated resources that supports the following requirements: • Allows demand-side resources to participate in multiple DR markets ranging from wholesale ancillary services to retail tariffs without being completely committed to a single entity like an Aggregator; • Allow aggregated groups of demand-side resources to be formed in an ad hoc fashion to address specific grid-side issues and support the optimization of the collective response of an aggregated group along a number of different dimensions. This is important in order to taylor the aggregated performance envelope to the needs to of the grid; • Allow aggregated groups to be formed in a hierarchical fashion so that each group can participate in variety of markets from wholesale ancillary services to distribution level retail tariffs. This paper explores the issues of aggregated groups of DR resources as described above especially within the context of emerging smart grid standards and the role they will play in both the management and interaction of various grid-side entities with those resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Implementation Scenarios for Electric Vehicle Roadway Wireless Power Transfer; NREL (National Renewable Energy Laboratory)

Analysis has been performed on the Transportation Secure Data Center (TSDC) warehouse of collected GPS second-by-second driving profile data of vehicles in the Atlanta, Chicago, Fresno, Kansas City, Los Angeles, Sacramento, and San Francisco Consolidated Statistical Areas (CSAs) to understand in-motion wireless power transfer introduction scenarios. In this work it has been shown that electrification of 1% of road miles could reduce fuel use by 25% for Hybrid Electric Vehicles (HEVs) in these CSAs. This analysis of strategically located infrastructure offers a promising approach to reduced fuel consumption; however, even the most promising 1% of road miles determined by these seven analysis scenarios still represent an impressive 2,700 miles of roadway to electrify. Therefore to mitigate the infrastructure capital costs, integration of the grid-tied power electronics in the Wireless Power Transfer (WPT) system at the DC-link to photovoltaic and/or battery storage is suggested. The integration of these resources would allow for the hardware to provide additional revenue through grid services at times of low traffic volumes and conversely at time of high traffic volumes these resources could reduce the peak demand that the WPT system would otherwise add to the grid.

33 ADVANCED PROPULSION SYSTEMS↗

Cyber-Physical Events Emulation Based Transmission and Distribution Co-Simulation for Situation Awareness and Grid Anomaly (SAGA) Detection: Preprint

Energy management of transmission and distribution networks is becoming more challenged with the accelerated increasing of distributed energy resources (DERs) such as distributed photovoltaic (PV) generation and distributed energy storage. To better analyze the impacts of DERs on both transmission and distribution systems, a comprehensive transmission and distribution co-simulation platform should be developed. Furthermore, with DERs more actively participated in system operation such as providing real time grid services, their cyber vulnerability should be better understood to maintain system reliability. This paper discussed a cyber-physical events emulation based transmission & distribution co-simulation platform to perform different cyber events emulation and analyze the impacts of cyber physical events happened in distribution system on the T&D system operation. The case studies with both a transmission network and a synthetic distribution network data validate that the proposed T&D co-simulation platform can perform comprehensive cyber physical events emulation. Therefore, with extensive simulation using the proposed model, the system operator can accumulate adequate training data for the system situation awareness and grid anomaly detection purpose.

31 CESER - Office of Cybersecurity, Energy Securit↗

Software defined networking moving target defense honeypot

Disclosed herein are systems, methods, and storage media for thwarting cyber-attacks and data theft. A computing system receives packets and compares with a configuration resource. The computing system determines that the packet does not match the configuration resource and transmits a packet to a decoy environment via an SDN switch. The decoy environment is configured to generate time-out, service unavailable, or restricted access messages. In some embodiments, the computing system determines the packet does match the configuration and transmits the packet to a production network via an SDN switch. The SDN switch is communicatively connected to the decoy environment through a first channel and communicatively connected to a production environment through a separate second channel. The computing system is further configured to create and transmit to the SDN switch, rules to manage transmitting the packet to either the decoy environment or the production environment.

Lyle, Joshua A.↗

Regional Real-Time PV Spinning Reserve Estimator

Curtailed photovoltaic (PV) generation is a zero-marginal-cost spinning reserve that can be used for a number of active power control services. Unlike traditional spinning reserve providers, however, i.e., fossil-fueled generators, which have well-defined operating characteristics, e.g., available headroom or potential high limit (PHL), PV plants have by nature variable and uncertain operating characteristics. To ensure the effective coordination between PV plants and the system operator during an active power control event, accurate knowledge of the PV PHL is essential. It ensures that enough headroom is reserved by the PV plants to deliver the award services in real time and informs feasible dispatch decisions made by the market operator. To tackle this challenge, a novel reference-control grouping-based PV plant reserve estimation method has been proposed by the National Renewable Energy Laboratory under past projects funded by the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Solar Energy Technologies Office. The estimation method separates inverters within a plant into two groups: a control group and a reference group. While the reference group is reserved to operate at its PHL, the control group can be curtailed to provide the grid services. Real-time outputs from the reference inverters are used to estimate the PHL for the whole plant based on the ratio between capacities of the reference group and of the plant. This work further enhances the methodology by (1) improving the model accuracy through machine learning; (2) automating the reference inverter selection through correlation analysis; (3) considering estimation look-ahead windows; and (4) applying to regional spinning reserve estimation. Significant performance improvement has been observed based on real-world data collected by CAISO, Southern Company, and Terabase Energy. Compared with the original scaling method, the newly proposed machine learning-based approach reduces the estimation errors by 30% and 13% at the plant level and region level, respectively. Results obtained from this project are intended to be used by grid operators, market operators, balancing authorities, and PV plant owners and operators to facilitate PV participation in ancillary service markets. Regulators, policymakers, and system planners can also consider the results of this work in their decision-making processes. In addition to the performance improvement on the existing reference-control based grouping method, we also investigated how the variability of PV generation from a single PV inverter can be used to represent the variability of PV generation at the plant level.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quantitative Evaluation of MD/HD Vehicle Electrification using Statistical Data

This paper presents a wide-ranging analysis of Class 3-8 commercial vehicle electrification by means of developing a framework tool which uses a quantitative method of estimating electric vehicle energy consumption and appropriate charging considerations. The Fleet DNA composite statistics on real-world driving behavior is used to evaluate feasible or market-ready battery electric vehicle (BEV) technologies in medium- and heavy-duty (MD/HD) applications. In the paper, ten representative Class 3-8 commercial vehicle electrifications have been evaluated as a function of various service coverages, including applications in port drayage tractors, refuse trucks, delivery trucks, buses, and bucket trucks. The results indicate significant energy savings and fuel cost savings across all MD/HD vehicle electrifications. The majority of MD BEVs, with the exception of Class 3 bucket trucks, achieve better than a 5-year payback with 50–75% service coverage. For HD BEVs, with the exception of the Class 8 port drayage tractors, the 90% service coverage results in a 10-year or longer payback time, while the 50% service coverage yields a 7–8 year payback. Class 8 port drayage tractors should achieve payback in no more than a 3.5 years with 50–75% service coverage. Thus, the analysis indicates a highly feasible potential for Class 3-6 MD vehicles to be electrified, and feasible opportunities for electrification in Class 7-8 HD short-distance applications.

33 ADVANCED PROPULSION SYSTEMS↗

Resist! : Sustaining forest carbon sequestration and wood production after insect disturbance

Disturbances from insect pests threaten ecologically and economically important goods and services supplied by forests, including wood production and carbon sequestration. We highlight the factors that influence these services’ resistance, a term quantifying the initial response to disturbance. Insects inflict damage through a range of mechanisms, prompting distinct plant physiological responses that scale to influence ecosystem processes and, with time, goods and services. The degree and timing of tree mortality and defoliation affect the amount of residual vegetation available to support compensatory wood production and influence carbon sequestration by changing rates of detritus-fueled decomposition. Compounding, or sequential, insect attacks may prime a forest for additional disturbance, further eroding wood production and carbon sequestration. Forest management practices that promote biological and structural diversity, and augment or retain limiting biological and nutrient resources, may buffer against the effects of insect pests on wood production and carbon sequestration.

Gough, Christopher M. [Virginia Commonwealth Univ.↗

Flexible Nuclear Energy for Clean Energy Systems

As part of the Nuclear Innovation: Clean Energy Future initiative, this report describes flexibility in nuclear systems, the value it can bring, and international experiences surrounding flexible nuclear energy. Flexible nuclear energy for this report is defined as “The ability of nuclear energy generation to economically provide energy services at the time and location they are needed by end-users. These energy services can include both electric and non-electric applications utilizing both traditional nuclear power plants and advanced integrated systems.” Flexibility in nuclear systems is enabled by three main mechanisms: core ramping, integrated energy systems with multiple byproducts, and thermal storage. The value of this flexibility on a $\$$/MW and a $\$$/MWh basis can be estimated through a combination of physics and economics modeling. International agencies describe their experiences in operating flexible nuclear systems and describe their plans for increasing nuclear flexibility in a clean energy system, likely with a high penetration of variable renewable energy.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗