Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thomson”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Calibration of a Thomson parabola ion spectrometer and Fujifilm imaging plate detectors for protons, deuterons, and alpha particles

A Thomson parabola ion spectrometer has been designed for use at the Multiterawatt (MTW) laser facility at the Laboratory for Laser Energetics (LLE) at University of Rochester. This device uses parallel electric and magnetic fields to deflect particles of a given mass-to-charge ratio onto parabolic curves on the detector plane. Once calibrated, the position of the ions on the detector plane can be used to determine the particle energy. The position dispersion of both the electric and magnetic fields of the Thomson parabola was measured using monoenergetic proton and alpha particle beams from the SUNY Geneseo 1.7 MV tandem Pelletron accelerator. The sensitivity of Fujifilm BAS-TR imaging plates, used as a detector in the Thomson parabola, was also measured as a function of the incident particle energy over the range from 0.6 MeV to 3.4 MeV for protons and deuterons and from 0.9 MeV to 5.4 MeV for alpha particles. The device was used to measure the energy spectrum of laser-produced protons at MTW.

43 PARTICLE ACCELERATORS↗

Conceptual design of new polychromator on Thomson scattering system to measure Z{sub eff}

To measure the Z{sub eff} with electron temperature (T{sub e}) and electron density (n{sub e}) profiles at the same time and the same position in the KSTAR tokamak, we design a new polychromator for Thomson scattering system that has additional function. The additional function is measuring bremsstrahlung intensity to calculate Z{sub eff} independent of Thomson signals. For this new polychromator, we design and fabricate a collimation lens set, and interference filter that has center wavelength of 523 nm and 2 nm FWHM. Finally, we change the lenses, detector diodes, and add the bremsstrahlung filter on the KSTAR edge Thomson scattering polychromator. Then this new polychromator was tested by Tungsten light and monochromator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prospects for the Thomson scattering system on NSTX-Upgrade

The paper discusses the projected configuration of the Thomson system on the National Spherical Torus Experiment (NSTX-U). In this paper, we discuss the projected configuration of the Thomson system on NSTX-U. More specifically, we determine, through both optical modeling of the collection optics and in-vessel measurements, that the collecting fibers are to be displaced by at most 1 cm toward the imaging plane along the optical axis. Finally, we estimate the performance of the Thomson system in measuring the electron temperature for NSTX-U discharges.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The circuit of polychromator for Experimental Advanced Superconducting Tokamak edge Thomson scattering diagnostic

The detector circuit is the core component of filter polychromator which is used for scattering light analysis in Thomson scattering diagnostic, and is responsible for the precision and stability of a system. High signal-to-noise and stability are primary requirements for the diagnostic. Recently, an upgraded detector circuit for weak light detecting in Experimental Advanced Superconducting Tokamak (EAST) edge Thomson scattering system has been designed, which can be used for the measurement of large electron temperature (T{sub e}) gradient and low electron density (n{sub e}). In this new circuit, a thermoelectric-cooled avalanche photodiode with the aid circuit is involved for increasing stability and enhancing signal-to-noise ratio (SNR), especially the circuit will never be influenced by ambient temperature. These features are expected to improve the accuracy of EAST Thomson diagnostic dramatically. Related mechanical construction of the circuit is redesigned as well for heat-sinking and installation. All parameters are optimized, and SNR is dramatically improved. The number of minimum detectable photons is only 10.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of maximum likelihood methods to laser Thomson scattering measurements of low density plasmas

Laser Thomson scattering (LTS) is an established plasma diagnostic technique that has seen recent application to low density plasmas. It is difficult to perform LTS measurements when the scattered signal is weak as a result of low electron number density, poor optical access to the plasma, or both. Photon counting methods are often implemented in order to perform measurements in these low signal conditions. However, photon counting measurements performed with photo-multiplier tubes are time consuming and multi-photon arrivals are incorrectly recorded. In order to overcome these shortcomings a new data analysis method based on maximum likelihood estimation was developed. The key feature of this new data processing method is the inclusion of non-arrival events in determining the scattered Thomson signal. Maximum likelihood estimation and its application to Thomson scattering at low signal levels is presented and application of the new processing method to LTS measurements performed in the plume of a 2-kW Hall-effect thruster is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electron kinetic effects on interferometry, polarimetry and Thomson scattering measurements in burning plasmas (invited)

At anticipated high electron temperatures in ITER, the effects of electron thermal motion on Thomson scattering (TS), toroidal interferometer/polarimeter (TIP), and poloidal polarimeter (PoPola) diagnostics will be significant and must be accurately treated. The precision of the previous lowest order linear in τ = T{sub e}/m{sub e}c{sup 2} model may be insufficient; we present a more precise model with τ{sup 2}-order corrections to satisfy the high accuracy required for ITER TIP and PoPola diagnostics. The linear model is extended from Maxwellian to a more general class of anisotropic electron distributions that allows us to take into account distortions caused by equilibrium current, ECRH, and RF current drive effects. The classical problem of the degree of polarization of incoherent Thomson scattered radiation is solved analytically exactly without any approximations for the full range of incident polarizations, scattering angles, and electron thermal motion from non-relativistic to ultra-relativistic. The results are discussed in the context of the possible use of the polarization properties of Thomson scattered light as a method of T{sub e} measurement relevant to ITER operational scenarios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Signal evaluations using singular value decomposition for Thomson scattering diagnostics

This paper provides a novel method for evaluating signal intensities in incoherent Thomson scattering diagnostics. A double-pass Thomson scattering system, where a laser passes through the plasma twice, generates two scattering pulses from the plasma. Evaluations of the signal intensities in the spectrometer are sometimes difficult due to noise and stray light. We apply the singular value decomposition method to Thomson scattering data with strong noise components. Results show that the average accuracy of the measured electron temperature (T{sub e}) is superior to that of temperature obtained using a low-pass filter (<20 MHz) or without any filters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The upgrade of the Thomson scattering system for measurement on the C-2/C-2U devices

The C-2/C-2U Thomson scattering system has been substantially upgraded during the latter phase of C-2/C-2U program. A Rayleigh channel has been added to each of the three polychromators of the C-2/C-2U Thomson scattering system. Onsite spectral calibration has been applied to avoid the issue of different channel responses at different spots on the photomultiplier tube surface. With the added Rayleigh channel, the absolute intensity response of the system is calibrated with Rayleigh scattering in argon gas from 0.1 to 4 Torr, where the Rayleigh scattering signal is comparable to the Thomson scattering signal at electron densities from 1 × 10{sup 13} to 4 × 10{sup 14} cm{sup −3}. A new signal processing algorithm, using a maximum likelihood method and including detailed analysis of different noise contributions within the system, has been developed to obtain electron temperature and density profiles. The system setup, spectral and intensity calibration procedure and its outcome, data analysis, and the results of electron temperature/density profile measurements will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Statistical analysis of non-Maxwellian electron distribution functions measured with angularly resolved Thomson scattering

Angularly resolved Thomson scattering is a novel extension of Thomson scattering, enabling the measurement of the electron velocity distribution function over many orders of magnitude. Here, details of the theoretical basis of the technique and the instrument designed for this measurement are described. Angularly resolved Thomson-scattering data from several experiments are shown with descriptions of the corresponding distribution functions. A reduced model describing the distribution function is given and used to perform a Monte Carlo analysis of the uncertainty in the measurements. The electron density and temperature were determined to a precision of 12% and 21%, respectively, on average, while all other parameters defining the distribution function were generally determined to better than 20%. It was found that these uncertainties were primarily due to limited signal to noise and instrumental effects. Furthermore, measurements with this level of precision were sufficient to distinguish between Maxwellian and non-Maxwellian distribution functions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Free space Thomson scattering to study high energy density shocks

A free space collective Thomson scattering system has been developed to study pulsed power produced plasmas. While most Thomson scattering diagnostics on pulsed power machines use a bundle of fibers to couple scattered light from the plasma to the spectrometer, this system used free space coupling of the light, which enabled a spatially continuous image of the plasma. Initial experiments with this diagnostic were performed on an inverse wire array generated by a 200 kA, 1100 ns rise time pulse power generator. The capabilities of this diagnostic were demonstrated by using the low frequency ion acoustic wave feature of the Thomson scattering spectra to measure the plasma flow velocity. The diagnostic was demonstrated to measure velocities between 20 and 40 km/s with an error of 4.7 km/s when fitting with a 600 μm spatial resolution or 8.9 km/s when fitting with a 150 μm spatial resolution. In some experiments, the diagnostic observed a bow shock in the plasma flow as the scattering intensity increased and flow velocity decreased.

47 OTHER INSTRUMENTATION↗

Probing local electron temperature and density inside a sheared flow stabilized Z-pinch using portable optical Thomson scattering

We report the first optical Thomson scattering measurements inside a high electron temperature (≳1 keV) and moderate electron density (mid 10 16 cm –3 ) plasma. This diagnostic has been built to provide critical plasma parameters, such as electron temperature and density, for Advanced Research Projects Agency-Energy-supported fusion-energy concepts. It uses an 8 J laser at 532 nm in 1.5 ns to measure the high frequency feature of the Thomson scattering profile at 17 locations along the probe axis. It is able to measure electron density from 5 × 10 17 cm –3 to several 10 19 cm –3 and electron temperatures from tens of eV to several keV. Here, in this paper, we describe the design, deployment, and analysis on the sheared flow stabilized Z-pinch machine at Zap Energy named FuZE. The probe beam is aimed at an axial distance of 20 cm from the central electrode and is timed within the temporal envelope of neutron emission. The high temperature and moderate density plasmas generated on FuZE lie in an unconventional regime for Thomson scattering as they are between tokamaks and laser-produced plasmas. We described the analysis considerations in this regime, show that the electron density was below 5 × 10 16 cm –3 at all times during these measurements, and present a sample shot where the inferred electron temperature varied from 167 ± 16 eV to 700 ± 85 eV over 1.6 cm.

47 OTHER INSTRUMENTATION↗

THE THOMSON SURFACE. II. POLARIZATION

The solar corona and heliosphere are visible via sunlight that is Thomson-scattered off free electrons, yielding a radiance against the celestial sphere. In this second part of a three-article series, we discuss linear polarization of this scattered light parallel and perpendicular to the plane of scatter in the context of heliospheric imaging far from the Sun. The difference between these two radiances (pB) varies quite differently with scattering angle, compared to the sum that would be detected in unpolarized light (B). The difference between these two quantities has long been used in a coronagraphic context for background subtraction and to extract some three-dimensional information about the corona; we explore how these effects differ in the wider-field heliospheric imaging case where small-angle approximations do not apply. We develop an appropriately simplified theory of polarized Thomson scattering in the heliosphere, discuss signal-to-noise considerations, invert the scattering equations analytically to solve the three-dimensional object location problem for small objects, discuss exploiting polarization for background subtraction, and generate simple forward models of several classes of heliospheric feature. We conclude that pB measurements of heliospheric material are much more localized to the Thomson surface than are B measurements, that the ratio pB/B can be used to track solar wind features in three dimensions for scientific and space weather applications better in the heliosphere than corona, and that,as an independent measurement of background signal, pB measurements may be used to reduce the effect of background radiances including the stably polarized zodiacal light.

79 ASTRONOMY AND ASTROPHYSICS↗

THE THOMSON SURFACE. III. TRACKING FEATURES IN 3D

In this, the final installment in a three-part series on the Thomson surface, we present simulated observations of coronal mass ejections (CMEs) observed by a hypothetical polarizing white light heliospheric imager. Thomson scattering yields a polarization signal that can be exploited to locate observed features in three dimensions relative to the Thomson surface. We consider how the appearance of the CME changes with the direction of trajectory, using simulations of a simple geometrical shape and also of a more realistic CME generated using the ENLIL model. We compare the appearance in both unpolarized B and polarized pB light, and show that there is a quantifiable difference in the measured brightness of a CME between unpolarized and polarized observations. We demonstrate a technique for using this difference to extract the three-dimensional (3D) trajectory of large objects such as CMEs. We conclude with a discussion on how a polarizing heliospheric imager could be used to extract 3D trajectory information about CMEs or other observed features.

79 ASTRONOMY AND ASTROPHYSICS↗

Influence of local-field corrections on Thomson scattering in collision-dominated two-component plasmas

The dynamic structure factor, which determines the Thomson scattering spectrum, is calculated via an extended Mermin approach. It incorporates the dynamical collision frequency as well as the local-field correction factor. This allows to study systematically the impact of electron-ion collisions as well as electron-electron correlations due to degeneracy and short-range interaction on the characteristics of the Thomson scattering signal. As such, the plasmon dispersion and damping width is calculated for a two-component plasma, where the electron subsystem is completely degenerate. Strong deviations of the plasmon resonance position due to the electron-electron correlations are observed at increasing Brueckner parameters r{sub s}. These results are of paramount importance for the interpretation of collective Thomson scattering spectra, as the determination of the free electron density from the plasmon resonance position requires a precise theory of the plasmon dispersion. Implications due to different approximations for the electron-electron correlation, i.e., different forms of the one-component local-field correction, are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Observation of Relativistic Effects in Collective Thomson Scattering

We observe relativistic modifications to the Thomson scattering spectrum in a traditionally classical regime: v{sub osc}/c=eE{sub 0}/cm{omega}{sub 0}<<1 and T{sub e}<1 keV. The modifications result from scattering off electron-plasma fluctuations with relativistic phase velocities. Normalized phase velocities v/c between 0.03 and 0.12 have been achieved in a N{sub 2} gas-jet plasma by varying the plasma density from 3x10{sup 18} cm{sup -3} to 7x10{sup 19} cm{sup -3} and electron temperature between 85 and 700 eV. For these conditions, the complete temporally resolved Thomson scattering spectrum including the electron and ion features has been measured. A relativistic treatment of the Thomson scattering form factor shows excellent agreement with the experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using collective x-ray Thomson scattering to measure temperature and density of warm dense matter

Collective x-ray Thomson scattering allows measuring plasmons, i.e electron plasma oscillations (Langmuir waves). This is manifest in the appearance of spectrally up- and down-shifted spectral features in addition to the Rayleigh signal. The ratio of the up- and down-shifted signals is directly related to detailed balance, allowing to determine the plasma temperature from first principles. The spectral shift of the plasmon signals is sensitive to temperature and electron density. We discuss the experimental considerations that have to be fulfilled to observe plasmon signals with x-ray Thomson scattering. As an example, we describe an experiment that used the Cl Ly-{alpha} x-ray line at 2.96 keV to measure collective Thomson scattering from solid beryllium, isochorically heated to 18 eV. Since temperature measurement based on detailed balance is based on first principles, this method is important to validate models that, for example, calculate the static ion-ion structure factor S{sub ii}(k).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Soft X-Ray Thomson Scattering in Warm Dense Hydrogen at FLASH

We present collective Thomson scattering with soft x-ray free electron laser radiation as a method to track the evolution of warm dense matter plasmas with {approx}200 fs time resolution. In a pump-probe scheme an 800 nm laser heats a 20 {micro}m hydrogen droplet to the plasma state. After a variable time delay in the order of ps the plasma is probed by an x-ray ultra violet (XUV) pulse which scatters from the target and is recorded spectrally. Alternatively, in a self-Thomson scattering experiment, a single XUV pulse heats the target while a portion of its photons are being scattered probing the target. From such inelastic x-ray scattering spectra free electron temperature and density can be inferred giving insight on relaxation time scales in plasmas as well as the equation of state. We prove the feasibility of this method in the XUV range utilizing the free electron laser facility in Hamburg, FLASH. We recorded Thomson scattering spectra for hydrogen plasma, both in the self-scattering and in the pump-probe mode using optical laser heating.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Joule-Thomson Cryogenic Nitrogen Orifice Flows

The Joule-Thomson Effect involves the expansion of a fluid through a throttling device, often a simple orifice, resulting in a change in the fluid's temperature. It has been leveraged in the design and analysis of Thermodynamic Vent Systems and integrated into injector designs for cryogenic no-vent fill tank-to-tank transfer testing. There is a scarcity of comprehensive data available to model the phenomenon effectively using tools such as GFSSP for cryogenic nitrogen flows. This experiment aims to model the Joule-Thomson effect of liquid nitrogen through seven traditionally manufactured, sharp-edged orifices manufactured by O’Keefe and three additively manufactured (AM) orifices manufactured by Cumberland Additive. The traditional orifice sizes were 0.016, 0.02, 0.024, 0.032, 0.037, and 0.04 inch in diameter. The three additive orifices had diameters with target/nominal sizes equal to the 0.016, 0.024, and 0.04 inch O’Keefe orifices. However, the actual diameters of the AM orifices were found to be 0.014, 0.024, and 0.035 inches due to additive manufacturing restrictions. Water was flowed through the orifices to verify that their flow coefficients matched published values and to establish flow coefficients for the AM orifices. Liquid nitrogen was flowed through the orifices in a separate test apparatus. The liquid nitrogen started as a subcooled liquid upstream of the orifice and transitioned into a two-phase gas-liquid mixture after passing through each orifice. The upstream pressure was set to 29 psia, 34 psia, 39 psia, and/or 42 psia or 44 psia. The pressure, temperature, and flow rate were measured upstream and downstream of the orifice for three trials at each set point. The average volumetric flow rate and Joule-Thomson Coefficients were calculated from this data. The AM orifices and traditionally manufactured orifices displayed similar results. This data will refine the dataset GFSSP uses to model the J-T Effect more accurately.

Joule-Thomson↗