Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Test methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

An improved three-point bending test method for the investigation of nanosecond laser dicing of ultrathin Si dies with Cu stabilization layer

Highlights: • A selective chemical etching method has been developed for removal of metallization layers on ultrathin Si dies for three-point bending test. • The complex elastoplastic stress distribution in the die is simplified to an elastic stress distribution. • The die sidewall fracture strength can be determined using the standard three-point bending tensile stress equation. • The characteristic fracture strengths of ultrathin Si dies were correlated to the laser-induced microstructures of the die sidewall. - Abstract: The sidewall fracture strength of ultrathin Si dies with frontside and backside metallization layers cannot be determined directly from three-point bending (3PB) test. The complex 3PB elastoplastic stress distribution makes it difficult to determine the die sidewall fracture strength by analytical method or finite element analysis due to various theoretical and practical constraints. In this work, a selective chemical etching method has been developed for complete removal of the frontside and backside metallization layers on the ultrathin die without affecting the critical microstructure and strength of the die sidewall induced by laser dicing. By removing all the metallization layers on the die, the complex 3PB elastoplastic stress distribution is simplified to an elastic stress distribution. This enables a straightforward calculation of the die sidewall fracture strength using the standard 3PB tensile stress equation for a homogeneous linear elastic material with a rectangular cross section. Two chemical etchants were evaluated and found to be suitable but FeCl{sub 3} is preferred because of the much faster etching time. With this improved 3PB test method, the effect of nanosecond laser dicing on ultrathin Si dies with backside Cu layer was investigated. The die frontside and backside characteristic fracture strengths of ultrathin Si dies with varying backside Cu thickness were determined and correlated to TEM analyses of the compositions and microstructures at the fracture origins.

36 MATERIALS SCIENCE↗

A New Test Method for Determining the Strength and Fracture Toughness of Cement Mortar and Concrete

The Spiral Notch Torsion Fracture Toughness Test (SNTT) was developed recently to determine the intrinsic fracture toughness (KIC) of structural materials. The SNTT system operates by applying pure torsion to uniform cylindrical specimens with a notch line that spirals around the specimen at a 45 a pitch. KIC values are obtained with the aid of a three-dimensional finite-element computer code, TOR3D-KIC. The SNTT method is uniquely suitable for testing a wide variety of materials used extensively in pressure vessel and piping structural components and weldments. Application of the method to metallic, ceramic, and graphite materials has been demonstrated. One important characteristic of SNTT is that neither a fatigue precrack or a deep notch are required for the evaluation of brittle materials, which significantly reduces the sample size requirement. In this paper we report results for a Portland cement-based mortar to demonstrate applicability of the SNTT method to cementitious materials. The estimated KIC of the tested mortar samples with compressive strength of 34.45 MPa was found to be 0.19 MPa m^(1/2).

36 MATERIALS SCIENCE↗

Advanced process control and novel test methods for PVD silicon and elastomeric silicone coatings utilized on ion implant disks, heatsinks and selected platens

Coatings play multiple key roles in the proper functioning of mature and current ion implanters. Batch and serial implanters require strategic control of elemental and particulate contamination which often includes scrutiny of the silicon surface coatings encountering direct beam contact. Elastomeric Silicone Coatings must accommodate wafer loading and unloading as well as direct backside contact during implant plus must maintain rigid elemental and particulate specifications. The semiconductor industry has had a significant and continuous effort to obtain ultra-pure silicon coatings with sustained process performance and long life. Low particles and reduced elemental levels for silicon coatings are a major requirement for process engineers, OEM manufacturers, and second source suppliers. Relevant data will be presented. Some emphasis and detail will be placed on the structure and characteristics of a relatively new PVD Silicon Coating process that is very dense and homogeneous. Wear rate under typical ion beam test conditions will be discussed. The PVD Silicon Coating that will be presented here is used on disk shields, wafer handling fingers/fences, exclusion zones of heat sinks, beam dumps and other beamline components. Older, legacy implanters can now provide extended process capability using this new generation PVD silicon - even on implanter systems that were shipped long before the advent of silicon coating for contamination control. Low particles and reduced elemental levels are critical performance criteria for the silicone elastomers used on disk heatsinks and serial implanter platens. Novel evaluation techniques and custom engineered tools are used to investigate the surface interaction characteristics of multiple Elastomeric Silicone Coatings currently in use by the industry - specifically, friction and perpendicular stiction. These parameters are presented as methods to investigate the critical wafer load and unload function. Unique tools and test methods have been developed that deliver accurate and repeatable data, which will be described.

36 MATERIALS SCIENCE↗

A harmonic pulse testing method for leakage detection in deep subsurface storage formations

Abstract Detection of leakage in deep geologic storage formations (e.g., carbon sequestration sites) is a challenging problem. This study investigates an easy‐to‐implement frequency domain leakage detection technology based on harmonic pulse testing (HPT). Unlike conventional constant‐rate pressure interference tests, HPT stimulates a reservoir using periodic injection rates. The fundamental principle underlying HPT‐based leakage detection is that leakage modifies a storage system's frequency response function, thus providing clues of system malfunction. During operations, routine HPTs can be conducted at multiple pulsing frequencies to obtain experimental frequency response functions, using which the possible time‐lapse changes are examined. In this work, a set of analytical frequency response solutions is derived for predicting system responses with and without leaks for single‐phase flow systems. Sensitivity studies show that HPT can effectively reveal the presence of leaks. A search procedure is then prescribed for locating the actual leaks using amplitude and phase information obtained from HPT, and the resulting optimization problem is solved using the genetic algorithm. For multiphase flows, the applicability of HPT‐based leakage detection procedure is exemplified numerically using a carbon sequestration problem. Results show that the detection procedure is applicable if the average reservoir conditions in the testing zone stay relatively constant during the tests, which is a working assumption under many other interpretation methods for pressure interference tests. HPT is a cost‐effective tool that only requires periodic modification of the nominal injection rate. Thus it can be incorporated into existing monitoring plans with little additional investment.

Sun, Alexander Y.↗

Analysis of the ANL Test Method for 6CVS Containment Vessels

In the fall of 2010, Argonne National Laboratory (ANL) contracted with vendors to design and build 6CVS containment vessels as part of their effort to ship Fuel Derived Mixed Fission Product material. The 6CVS design is based on the Savannah River National Laboratory's (SRNL) design for 9975 and 9977 six inch diameter containment vessels. The main difference between the designs is that the 6CVS credits the inner O-ring seal as the containment boundary while the SRNL design credits the outer O-ring seal. Since the leak test must be done with the inner O-ring in place, the containment vessel does not have a pathway for getting the helium into the vessel during the leak test. The leak testing contractor was not able to get acceptable leak rates with the specified O-ring, but they were able to pass the leak test with a slightly larger O-ring. ANL asked the SRNL to duplicate the leak test vendor's method to determine the cause of the high leak rates. The SRNL testing showed that the helium leak indications were caused by residual helium left within the 6CVS Closure Assembly by the leak test technique, and by helium permeation through the Viton O-ring seals. After SRNL completed their tests, the leak testing contractor was able to measure acceptable leak rates by using the slightly larger O-ring size, by purging helium from the lid threads, and by being very quick in getting the bell jar under a full vacuum. This paper describes the leak test vendor's test technique, and other techniques that could be have been used to successfully leak test the 6CVS's.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Corrosion Testing Trade Study on Testing Methods in Molten Salts

In assessing molten salt compatibility with structural materials, static testing is often reported because it is easy to conduct. However, in order to assess mass transfer, where material dissolves in the salt in the hot section and may precipitate out of the liquid in colder regions, a flowing salt experiment in a temperature gradient is needed. While a forced convection or pumped loop produces prototypic flowing conditions, it also is a multi-million dollar investment. Among the less expensive dynamic testing options, the thermal convection loop (TCL) was favored during the 1960’s development of molten salt reactor technology. Because the workforce and core facilities are currently available to conduct TCL experiments, it is the least expensive strategy to evaluate candidate structural alloys in flowing molten salt conditions.

36 MATERIALS SCIENCE↗

SU-E-T-19: A New End-To-End Test Method for ExacTrac for Radiation and Plan Isocenter Congruence

Purpose: To combine and integrate quality assurance (QA) of target localization and radiation isocenter End to End (E2E) test of BrainLAB ExacTrac system, a new QA approach was devised using anthropomorphic head and neck phantom. This test insures the target localization as well as radiation isocenter congruence which is one step ahead the current ExacTrac QA procedures. Methods: The head and neck phantom typically used for CyberKnife E2E test was irradiated to the sphere target that was visible in CT-sim images. The CT-sim was performed using 1 mm thickness slice with helical scanning technique. The size of the sphere was 3-cm diameter and contoured as a target volume using iPlan V.4.5.2. A conformal arc plan was generated using MLC-based with 7 fields, and five of them were include couch rotations. The prescription dose was 5 Gy and 95% coverage to the target volume. For the irradiation, two Gafchromic films were perpendicularly inserted into the cube that hold sphere inside. The linac used for the irradiation was TrueBeam STx equipped with HD120 MLC. In order to use ExacTrac, infra-red head–array was used to correlate orthogonal X-ray images. Results: Using orthogonal X-rays of ExacTrac the phantom was positioned. For each field, phantom was check again with X-rays and re-positioned if necessary. After each setup using ExacTrac, the target was irradiated. The films were analyzed to determine the deviation of the radiation isocenter in all three dimensions: superior-inferior, left-right and anterior-posterior. The total combining error was found to be 0.76 mm ± 0.05 mm which was within sub-millimeter accuracy. Conclusion: Until now, E2E test for ExacTrac was separately implemented to test image localization and radiation isocenter. This new method can be used for periodic QA procedures.

60 APPLIED LIFE SCIENCES↗

A test method for determining adhesion forces and Hamaker constants of cementitious materials using atomic force microscopy

A method for determining Hamaker constant of cementitious materials is presented. The method involved sample preparation, measurement of adhesion force between the tested material and a silicon nitride probe using atomic force microscopy in dry air and in water, and calculating the Hamaker constant using appropriate contact mechanics models. The work of adhesion and Hamaker constant were computed from the pull-off forces using the Johnson-Kendall-Roberts and Derjagin-Muller-Toropov models. Reference materials with known Hamaker constants (mica, silica, calcite) and commercially available cementitious materials (Portland cement (PC), ground granulated blast furnace slag (GGBFS)) were studied. The Hamaker constants of the reference materials obtained are consistent with those published by previous researchers. The results indicate that PC has a higher Hamaker constant than GGBFS. The Hamaker constant of PC in water is close to the previously predicted value C{sub 3}S, which is attributed to short hydration time ({<=} 45 min) used in this study.

36 MATERIALS SCIENCE↗

Performance Evaluation and Loss Modeling of WBG Devices based on a Novel Double-Pulse Test Method for Current Source Inverter

Careful measurements of the power device characteristics are necessary to accurately estimate a power converter's losses and efficiency. The conventional double-pulse test (DPT) circuit is a well-known method to implement this laboratory characterization of power devices and power modules. However, the switching characteristics of a power device depend on the power electronics circuit in which it is connected as well as the power circuit's physical layout, in addition to the device's internal structure. Hence, the conventional DPT circuit configuration, which is tailored for a standard voltage-source inverter (VSI), is not well-suited for a current-source inverter (CSI). This paper demonstrates a previously-proposed CSI-based DPT measurement technique that is appropriate for normal CSI operation. The characteristics of SiC MOSFETs and series-connected SiC Schottky diodes used in a CSI are measured using this improved technique while taking temperature effects into account to yield more accurate loss predictions. The CSI losses, including the switching and conduction losses of SiC MOSFETs and SiC Schottky diodes, have been modeled using this approach. The total CSI losses and efficiency have been estimated based on the CSI DPT results and loss models.

42 ENGINEERING↗

1:52 Scale Testing of the First US Commercial Scale Floating Wind Turbine, VolturnUS: Testing Overview and the Evolution of Scale Model Testing Methods

Over the past 6 years, the University of Maine (UMaine) has been an active contributor in research and scale-model testing of floating offshore wind turbines (FOWTs). This paper serves to share the evolution of UMaine’s scale-model testing pedigree by exploring the various test campaigns at a high level, culminating with the design validation of the VolturnUS floating platform. These model test campaigns have each provided key insights into the behavior of FOWT platforms as well as improving the ability to perform model tests of FOWTs. In 2011, the UMaine-led DeepCwind Consortium carried out 1/50-scale model tests of a generic tension leg platform (TLP), a semi-submersible (semi), and a spar-buoy (spar) floating platform at the Maritime Research Institute Netherlands (MARIN) test facility. The designs were Froude-scaled and supported a scaled version of the 5-MW National Renewable Energy Laboratory (NREL) offshore research turbine. Data from these tests has been used extensively for numerical simulation validation efforts using NREL’s computer-aided engineering software FAST and laid the foundation for UMaine’s design efforts on VolturnUS. In 2013, UMaine conducted another test campaign at MARIN using the original semi-submersible from 2011 with an improved turbine as well as a 1:50-scale model of the VolturnUS concrete semi-submersible design. The improved DeepCwind semi-submersible data is currently being utilized in the validation of a large number of other analysis codes as part of the International Energy Agency’s OC5 project. In 2015, UMaine opened its own Wind/Wave test facility, the Alfond Wind/Wave Ocean Engineering Laboratory (W2). Utilizing this new facility, UMaine tested the 1:50-scale model DeepCwind semi-submersible, repeating the tests from MARIN, to validate the experimental equipment and procedures as well as demonstrate the capability of the W2. In 2016 UMaine carried out testing of a 1:52-scale model of the 100% design of the VolturnUS with a 6-MW topside as a final design validation to support the US Department of Energy-supported, full-scale Aqua Ventus demonstration project scheduled to be connected to the grid in 2019. A newly designed 6-MW scale model turbine was used in this test and the performance-matched turbine design methodology is described. Selected results from the test campaign and preliminary numerical comparisons are discussed as well as key lessons learned from the model test campaigns are presented.

17 WIND ENERGY↗

Comparison of CO 2 Detection Methods Tested in Shallow Groundwater Monitoring Wells at a Geological Sequestration Site

The geological storage of anthropogenic carbon dioxide (CO 2 ) is one method of reducing the amount of CO 2 released into the atmosphere. Monitoring programs typically determine baseline conditions in surface and near-surface environments before, during, and after CO 2 injection to evaluate if impacts related to injection have occurred. Because CO 2 concentrations in groundwater fluctuate naturally due to complex geochemical and geomicrobiologicalinteractions, a clear understanding of the baseline behavior of CO 2 in groundwater near injection sites is important. Numerous ways of measuring aqueous CO 2 in the field and lab are currently used, but most methods have significant shortcomings (e.g., are tedious, lengthy, have interferences, or have significant lag time before a result is determined). In this study, we examined the effectiveness of two novel CO 2 detection methods and their ability to rapidly detect CO2in shallow groundwater monitoring wells associated with the Illinois Basin –Decatur Project geological sequestration site. The CarboQC beverage carbonation meter was used to measure the concentration of CO 2 in water by monitoring temperature and pressure changes and calculating the PCO 2 from the ideal gas law. Additionally, a non-dispersive infrared (NDIR) CO< sub>2 sensor enclosed in a gas-permeable, water-impermeable membrane measured CO2by determining an equilibrium concentration. Results showed that the CarboQC method provided rapid (< 3 min) and repeatable results under field conditions within a measured concentration range of 15 –125 mg/L CO 2 . The NDIR sensor results correlated well (r 2 = 0.93) with the CarboQC data, but CO 2 equilibration required at least 15 minutes, making the method somewhat less desirable under field conditions. In contrast, NDIR-based sensors have a greater potential for long-term deployment. Both systems are adaptable to in-line groundwater sampling methods. Other specific advantages and disadvantages associated with the two approaches, and anomalies associated with specific samples, are discussed in greater detail in this poster.

54 ENVIRONMENTAL SCIENCES↗

Comparison of Infiltration Test Methods for Soil Health Assessment

Infiltration rate (IR) has been commonly used as a metric to evaluate soil quality and health. For the USDA Soil Quality Test Kit, a 15-cm (6-in) diameter (ID) cylinder is used to measure IR with 444 cm 3 (equivalent to 2.54 cm or 1 in) of water while other standard IR procedures require substantially larger volumes of water. The general objective of this study was to compare different methods for IR measurement. Using three replications, IR measurements were conducted along a 9-m (27-ft) long transect in two different soil types by the double-ring infiltrometer (DRI) using 25- and 50-cm (10-and 20-in, respectively) cylinders, single-ring infiltrometer (SRI) using 25- and 50-cm cylinders, Cornell sprinkle infiltrometer (CSI) using a 24.1-cm (9.5-in) cylinder, the USDA recommended procedure using a 15-cm diameter cylinder (hereafter referred to as USDA-15 method), and a modified USDA method using a 24.1-cm diameter cylinder. Although the USDA-15 method is simple and requires a small amount of water, based on high variability among replications and significant reduction in IR during early stages of water entry into the soil, the procedure does not offer an accurate estimate of the soil infiltration potential. The CSI procedure was reproducible, but it is more cumbersome to perform than other methods. The DRI, SRI, and CSI methods required a much greater volume of water than the USDA-15 method but produced results that are more consistent. The most consistent results were obtained by the CSI and DRI methods. The modified USDA method results were similar to the SRI method and were an improvement over the original USDA-15 method. For assessing soil health, additional investigations should be conducted to evaluate a modified version of the USDA procedure using a larger cylinder.

54 ENVIRONMENTAL SCIENCES↗

A Biochar Classification System and Associated Test Methods

In this chapter, a biochar classification system related to its use as soil amendment is proposed. This document builds upon previous work: “Standardized product definition and product testing guidelines for biochar that is used in soil” (IBI, 2015) (aka IBI Biochar Standards) and “Guidelines for biochar production for a sustainable production of biochar: European Biochar Certificate” (EBC, 2012-2022) (aka EBC Biochar Standards). It should be noted that the EBC guidelines constitute the basis for biochar certification through the independent government accredited inspection agency, Bio.Inspecta AG. The present document constrains its scope to materials with properties that satisfy the criteria for biochar as defined by either the IBI Biochar Standards or the EBC Standards (Annex I), as required by the current methodologies developed for accounting carbon credits associated with the biochar use in the voluntary market (e.g., Verra, Puro.Earth). The classification system envisions enabling stakeholders and commercial entities to (i) identify the most suitable biochar to fulfil the requirements for a particular soil and/or land-use, (ii) distinguish the application of biochar for specific niches (e.g., soilless agriculture), and (iii) assess the climate-impact value based on biochar properties, production efficiency, and alternative feedstock uses. It is based on the best current knowledge and will need to be improved as new data and knowledge become available in the scientific literature.

biochar, climate change impacts, soil amendment, c↗

A polyvalent harmonic coil testing method for small-aperture magnets

A method to characterize permanent and fast-pulsed iron-dominated magnets with small apertures is presented. The harmonic coil measurement technique is enhanced specifically for small-aperture magnets by (1) in situ calibration, for facing search-coil production inaccuracy, (2) rotating the magnet around its axis, for correcting systematic effects, and (3) measuring magnetic fluxes by stationary coils at different angular positions for measuring fast pulsed magnets. This method allows a quadrupole magnet for particle accelerators to be characterized completely, by assessing multipole field components, magnetic axis position, and field direction. In this paper, initially the metrological problems arising from testing small-aperture magnets are highlighted. Then, the basic ideas of the proposed method and the architecture of the corresponding measurement system are illustrated. Finally, experimental validation results are shown for small-aperture permanent and fast-ramped quadrupole magnets for the new linear accelerator Linac4 at CERN (European Organization for Nuclear Research).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Innovative test method for the estimation of the foaming tendency of substrates for biogas plants

Graphical abstract: Display Omitted - Highlights: • Foaming in biogas plants depends on the interactions between substrate and digestate. • Foaming tests enable the evaluation of substrate foaming tendency in biogas plants. • Leipzig foam tester enables foaming tests of substrates prior to use. - Abstract: Excessive foaming in anaerobic digestion occurs at many biogas plants and can cause problems including plugged gas pipes. Unfortunately, the majority of biogas plant operators are unable to identify the causes of foaming in their biogas reactor. The occurrence of foaming is often related to the chemical composition of substrates fed to the reactor. The consistency of the digestate itself is also a crucial part of the foam formation process. Thus, no specific recommendations concerning substrates can be given in order to prevent foam formation in biogas plants. The safest way to avoid foaming is to test the foaming tendency of substrates on-site. A possible solution is offered by an innovative foaming test. With the help of this tool, biogas plant operators can evaluate the foaming disposition of new substrates prior to use in order to adjust the composition of substrate mixes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laboratory testing methods to evaluate the reliability of occupancy sensors for commercial building applications

The energy performance of commercial buildings is greatly influenced by occupants which are highly variable and among the most unpredictable components of a building's operation. While most building control systems use fixed, predetermined occupancy schedules, these fixed occupancy levels can be quite different from actual occupancy. This can cause unnecessary energy consumption, particularly from heating, ventilation, and air conditioning (HVAC) and lighting systems which are responsible for approximately 60% of commercial buildings' energy use. The use of occupancy counting sensor systems integrated with building management system controls is one method that can be used to improve the energy-consuming performance of buildings. However, there is no standardized universal methodology and metrics to evaluate their reliability. The aim of this research is to develop a uniform evaluation methodology to assess the reliability of occupancy counting sensor systems in a controlled laboratory environment. The developed testing methodology includes both “typical” scenarios representing the occupancy scenarios of a typical commercial building, and “failure” testing scenarios which represent a range of potential scenarios that may impact a sensor system's reliability. These methods were then implemented in a case study to evaluate the performance of two novel occupancy counting sensor systems (i.e., door-centric, and camera-based). Results suggest that typical testing results can be used to compare the overall performance of the occupancy counting sensor systems; however, failure testing is also important to understand the weaknesses of the sensor system in order to select the suitable one for the intended use of the commercial building. In addition, the proposed methodology includes a modified confusion matrix which enables the ability to identify if failures are caused by over or under counting occupants and to what extent this occurs over the testing period.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗