Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Temperature metrology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

WGM Temperature Tracker

This software implements digital control of a WGM (whispering-gallerymode) resonator temperature based on the dual-mode approach. It comprises one acquisition (dual-channel) and three control modules. The interaction of the proportional-integral loops is designed in the original way, preventing the loops from fighting. The data processing is organized in parallel with the acquisition, which allows the computational overhead time to be suppressed or often completely avoided. WGM resonators potentially provide excellent optical references for metrology, clocks, spectroscopy, and other applications. However, extremely accurate (below micro-Kelvin) temperature stabilization is required. This software allows one specifically advantageous method of such stabilization to be implemented, which is immune to a variety of effects that mask the temperature variation. WGM Temperature Tracker 2.3 (see figure) is a LabVIEW code developed for dual-mode temperature stabilization of WGM resonators. It has allowed for the temperature stabilization at the level of 200 nK with one-second integration time, and 6 nK with 10,000-second integration time, with the above room-temperature set point. This software, in conjunction with the appropriate hardware, can be used as a noncryogenic temperature sensor/ controller with sub-micro-Kelvin sensitivity, which at the time of this reporting considerably outperforms the state of the art.

Strekalov, Dmitry V.↗

Photogrammetric Metrology for the James Webb Space Telescope Integrated Science Instrument Module

The James Webb Space Telescope (JWST) is a 6.6m diameter, segmented, deployable telescope for cryogenic IR space astronomy (approximately 40K). The JWST Observatory architecture includes the Optical Telescope Element and the Integrated Science Instrument Module (ISIM) element that contains four science instruments (SI) including a Guider. The ISM optical metering structure is a roughly 2.2x1.7x2.2m, asymmetric frame that is composed of carbon fiber and resin tubes bonded to invar end fittings and composite gussets and clips. The structure supports the SIs, isolates the SIs from the OTE, and supports thermal and electrical subsystems. The structure is attached to the OTE structure via strut-like kinematic mounts. The ISIM structure must meet its requirements at the approximately 40K cryogenic operating temperature. The SIs are aligned to the structure's coordinate system under ambient, clean room conditions using laser tracker and theodolite metrology. The ISIM structure is thermally cycled for stress relief and in order to measure temperature-induced mechanical, structural changes. These ambient-to-cryogenic changes in the alignment of SI and OTE-related interfaces are an important component in the JWST Observatory alignment plan and must be verified. We report on the planning for and preliminary testing of a cryogenic metrology system for ISIM based on photogrammetry. Photogrammetry is the measurement of the location of custom targets via triangulation using images obtained at a suite of digital camera locations and orientations. We describe metrology system requirements, plans, and ambient photogrammetric measurements of a mock-up of the ISIM structure to design targeting and obtain resolution estimates. We compare these measurements with those taken from a well known ambient metrology system, namely, the Leica laser tracker system. We also describe the data reduction algorithm planned to interpret cryogenic data from the Flight structure. Photogrammetry was selected from an informal trade study of cryogenic metrology systems because its resolution meets sub-allocations to ISIM alignment requirements and it is a non-contact method that can in principle measure six degrees of freedom changes in target location. In addition, photogrammetry targets can be readily related to targets used for ambient surveys of the structure. By thermally isolating the photogrammetry camera during testing, metrology can be performed in situ during thermal cycling. Photogrammetry also has a small but significant cryogenic heritage in astronomical instrumentation metrology. It was used to validate the displacement/deformation predictions of the reflectors and the feed horns during thermal/vacuum testing (90K) for the Microwave Anisotropy Probe (MAP). It also was used during thermal vacuum testing (100K) to verify shape and component alignment at operational temperature of the High Gain Antenna for New Horizons. With tighter alignment requirements and lower operating temperatures than the aforementioned observatories, ISIM presents new challenges in the development of this metrology system.

Nowak, Maria↗

RF Metrology of Lunar Highlands Regolith Simulant NU-LHT-2M

Understanding the electrical properties of lunar regolith is vital to modeling radiofrequency(RF) propagation on the lunar surface a fundamental step in planning lunar surface missions. Near the lunar south pole, the regolith has yet to be directly sampled and thus there remains uncertainty in the electrical properties of the regolith. The regolith simulant NU-LHT-2M is a highlands simulant that is representative of the expected chemical composition of the regolith near the lunar south pole. Previous studies have investigated properties of NU-LHT at UHF and S-band[1]. Future missions to the lunar south pole are expected to utilize X and Ka-band for direct-to-Earth links and UHF, S-band, C-band, and Ka-band for lunar surface communication[2]. As a result, it is necessary to electrically characterize the lunar regolith at these frequencies. In this paper, coaxial impedance dielectric reflectometry is performed on the NU-LHT-2M simulant using a commercially available soil permittivity measurement device. This study serves as a preliminary measurement of the simulant and may lead to enhanced efficacy of the measurement hardware for future applications.

simulant↗

RF Metrology of Lunar Highlands Regolith Simulant NU-LHT-2M

*Presentation for the publication* Understanding the electrical properties of lunar regolith is vital to modeling radiofrequency (RF) propagation on the lunar surface, a fundamental step in planning lunar surface missions. Near the lunar south pole, the regolith has yet to be directly sampled and thus there remains uncertainty in the electrical properties of the regolith. The regolith simulant NU-LHT-2M is a highlands simulant that is representative of the expected chemical composition of the regolith near the lunar south pole. Previous studies have investigated properties of NU-LHT at UHF and S-band[1]. Future missions to the lunar south pole are expected to utilize X and Ka-band for direct-to-Earth links and UHF, S-band, C-band, and Ka-band for lunar surface communication [2]. As a result, it is necessary to electrically characterize the lunar regolith at these frequencies. In this paper, coaxial impedance dielectric reflectometry is performed on the NU-LHT-2M simulant using a commercially available soil permittivity measurement device. This study serves as a preliminary measurement of the simulant and may lead to enhanced efficacy of the measurement hardware for future applications.

simulant↗

Mid-infrared photodetection with 2D metal halide perovskites at ambient temperature

The detection of mid-infrared (MIR) light is technologically important for applications such as night vision, imaging, sensing, and thermal metrology. Traditional MIR photodetectors either require cryogenic cooling or have sophisticated device structures involving complex nanofabrication. Here, we conceive spectrally tunable MIR detection by using two-dimensional metal halide perovskites (2D-MHPs) as the critical building block. Leveraging the ultralow cross-plane thermal conductivity and strong temperature-dependent excitonic resonances of 2D-MHPs, we demonstrate ambient-temperature, all-optical detection of MIR light with sensitivity down to 1 nanowatt per square micrometer, using plastic substrates. Through the adoption of membrane-based structures and a photonic enhancement strategy unique to our all-optical detection modality, we further improved the sensitivity to sub–10 picowatt-per-square-micrometer levels. The detection covers the mid-wave infrared regime from 2 to 4.5 micrometers and extends to the long-wave infrared wavelength at 10.6 micrometers, with wavelength-independent sensitivity response. Our work opens a pathway to alternative types of solution-processable, long-wavelength thermal detectors for molecular sensing, environmental monitoring, and thermal imaging.

Li, Yanyan [Yale University, New Haven, CT (United↗

The Mobile Chamber

A document discusses a simulation chamber that represents a shift from the thermal-vacuum chamber stereotype. This innovation, currently in development, combines the capabilities of space simulation chambers, the user-friendliness of modern-day electronics, and the modularity of plug-and-play computing. The Mobile Chamber is a customized test chamber that can be deployed with great ease, and is capable of bringing payloads at temperatures down to 20 K, in high vacuum, and with the desired metrology instruments integrated to the systems control. Flexure plans to lease Mobile Chambers, making them affordable for smaller budgets and available to a larger customer base. A key feature of this design will be an Apple iPad-like user interface that allows someone with minimal training to control the environment inside the chamber, and to simulate the required extreme environments. The feedback of thermal, pressure, and other measurements is delivered in a 3D CAD model of the chamber's payload and support hardware. This GUI will provide the user with a better understanding of the payload than any existing thermal-vacuum system.

Scharfstein, Gregory↗

FIRST Mirror Review

As part of a JPL-funded effort to develop lightweight telescope technology suitable for far-infrared astronomy, COI designed and fabricated a spherical, f/1, 2-meter aperture prototype primary mirror using solely graphite/resin composite materials. To assess the performance of this technology, optical metrology of the mirror surface was performed from ambient to an intended operational temperature for IR-telescopes of 70K. Testing was performed horizontally in a cryogenic vacuum chamber at Arnold AFB, Tennessee. The test design had to accommodate requirements for rapid and uniform cooling across the optic, passivation of the ambient vibrational environment, and de-coupling of the mirror from the thermal strain of the test stand. An IR-wavelength phase shifting interferometer (PSI) was the primary instrument used to measure the mirror surface. From an initial surface figure of 2.1 microns RMS at ambient, a modest 3.9 microns of additional RMS surface error was induced at 70K. The thermally induced error was dominated by low-order deformations, of the type that could easily be corrected with secondary or tertiary optics. In addition to exceptional thermal stability, the mirror exhibited no measurable hysteresis between both ambient and cryo measurements.

Dodson, Kelly↗

Cryogenic (70K) measurement of an all-composite 2-meter diameter mirror

The Herschel Space observatory (formerly known as FIRST) consists of a 3.5 m space telescope. In order to develop lightweight telescope technology suitable for this mission, COI designed and fabricated aspherical, f/1 2 m aperture prototype primary mirror using solely carbon fiber reinforced polypmer (CFR) materials. To assess the performance of this technology, optical metrology of the mirror surface was performed from ambient to an intended operational temperature for IR-telescopes of 70K. Testing was performed horizontally in a cryogenic vacuum chamber at Arnold Engineering Development Center (AEDC), Tennessee.

lightweight mirrors cryogenic testing composite ma↗

A Cryogenic Waveguide Mount for Microstrip Circuit and Material Characterization

A waveguide split-block fixture used in the characterization of thin-film superconducting planar circuitry at millimeter wavelengths is described in detail. The test fixture is realized from a pair of mode converters, which transition from rectangular-waveguide to on-chip microstrip-line signal propagation via a stepped ridge-guide impedance transformer. The observed performance of the W-band package at 4.2K has a maximum in-band transmission ripple of 2dB between 1.53 and 1.89 times the waveguide cutoff frequency. This metrology approach enables the characterization of superconducting microstrip test structures as a function temperature and frequency. The limitations of the method are discussed and representative data for superconducting Nb and NbTiN thin film microstrip resonators on single-crystal Si dielectric substrates are presented.

U-yen, Kongpop↗

A Cryogenic Waveguide Mount for Microstrip Circuit and Material Characterization

A waveguide split-block fixture used in the characterization of thin-film superconducting planar circuitry at millimeter wavelengths is described in detail. The test fixture is realized from a pair of mode converters, which transition from rectangular-waveguide to on-chip microstrip-line signal propagation via a stepped ridge-guide impedance transformer. The observed performance of the W-band package at 4.2K has a maximum in-band transmission ripple of 2dB between 1.53 and 1.89 times the waveguide cutoff frequency. This metrology approach enables the characterization of superconducting microstrip test structures as a function temperature and frequency. The limitations of the method are discussed and representative data for superconducting Nb and NbTiN thin film microstrip resonators on single-crystal Si dielectric substrates are presented.

U-yen, Kongpop↗

Scanning Tunneling Thermometry

The best spatial resolution so far achieved in thermal imaging is several nanometers, much coarser than routinely achieved for other physical properties. Here we propose a method to map electronic temperature variations in operating nanoscale conductors by relying solely upon electrical tunneling current measurements. The proposed measurement scheme involves two scanning probe operations to measure the conductance and thermopower, respectively. These two measurements are shown to determine the local temperature with high accuracy in nanoscale conductors, where the Wiedemann-Franz law holds quite generally. We report the proposed scanning tunneling thermometer, owing to its operation in the tunneling regime, would be capable of mapping temperature variations with subnanometer resolution, thereby enhancing the resolution of scanning thermometry by some 2 orders of magnitude.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ground-Based Investigations with the Cryogenic Hydrogen Maser

The room temperature hydrogen maser is an active atomic oscillator used as a high-frequency-stability local oscillator for radio astronomy, metrology, and spacecraft navigation, and in tests of fundamental physics. The cryogenic hydrogen maser (CHM) operates at 0.5 K, employing superfluid helium-coated walls to store the masing hydrogen atoms. We are investigating whether the CHM may provide better frequency stability than the room temperature hydrogen maser: one to three orders of magnitude improvement may be possible because of greatly reduced thermal noise and larger signal power. Exceptional frequency stability will be required for spacecraft tracking in future deep-space missions, for space-based tests of relativity and gravitation, and for local (i.e., flywheel) oscillators used with absolute frequency standards such as laser-cooled atomic fountains and linear ion traps. These new devices are passive high-resolution frequency discriminators. Alone, they cannot function as superior atomic clocks; their effective operation depends on being integrated with an active local oscillator with excellent short term stability - such as that possible with the CHM.

Walsworth, Ronald L.↗

Iron dopant energy levels in β-Ga 2 O 3

The energetic positions of the two Fe dopant levels in the bandgap of β-Ga 2 O 3 are determined to be at 3.05(±0.05) and 3.85(±0.05) eV below the conduction band minimum from transmission measurements employing a sub-picosecond tunable ultraviolet laser radiation source. A further measurement of the quantum efficiency of photoelectron emission from the Fe:Ga 2 O 3 (010) photocathode is consistent with the obtained absorption data and a dominant optical phonon assisted Franck–Condon emission mechanism, while also providing an estimate of 100 ps for the conduction band electron lifetime.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Urban Heat Island Phenomenon: How Its Effects Can Influence Environmental Decision Making in Your Community

Reinvestment in urban centers is breathing new life into neighborhoods that have been languishing as a result of explosive suburban development over the past several decades. In cities all over the country, adaptive reuse, brownfields redevelopment, transforming urban landscapes, economies, and quality of life. However, the way in which this development occurs has the potential to exacerbate the urban heat island (UHI) phenomenon, an existing problem in many areas and one which poses a threat to the long-term sustainability and environmental quality of cities. The UHI phenomenon is rooted in the science of how the land covers respond to solar heating and can adversely effect the environment. This phenomenon is responsible for urban centers having higher air temperatures and poorer air quality than suburban areas. In addition, the UHI phenomenon causes metrological occurrences, degrades water quality, increases energy demands, poses threats to public health and contributes to global warming. While the name of the phenomenon implies that is solely an urban issue, research has shown that the effects of the UHI are becoming prevalent in suburbs, as well. The UHI phenomenon can plague regions - urban centers and their suburbs. Furthermore, heat islands have been found to exist in both city centers and suburban communities. As suburban areas increasingly develop using land covers and building materials common to urban areas, they are inheriting urban problems - such as heat islands. In this way, it may be necessary for non-urban communities to engage in heat island mitigation. The good news is that through education and planning, the effects of the UHI phenomenon can be prevented and mitigated. Heat islands are more a product of urban design rather than the density of development. Therefore, cities can continue to grow and develop without exacerbating the UHI by employing sustainable development strategies.

Estes, Maurice G., Jr.↗

ROADRUNNER uranium nitride MiniFuel: Experimental design, fabrication and pre-irradiation baseline characterization for accelerated burnup testing

Uranium nitride (UN) is a promising fuel candidate for advanced reactor systems owing to its high uranium density and thermal conductivity; however, its qualification remains constrained by the scarcity of well-controlled irradiation performance data. Here, to address this limitation, the ROADRUNNER (Research On ADvancing the peRformance of UraNium Nitrides in Extreme enviRonments) campaign employs the MiniFuel platform in the High Flux Isotope Reactor (HFIR) to enable accelerated burnup irradiation testing under tightly controlled and largely isothermal conditions. This paper presents the experimental design, fuel fabrication, and pre-irradiation baseline characterization of the ROADRUNNER UN MiniFuel campaign. Thirty-six UN minidisc specimens were fabricated with systematically varied as-fabricated density (86–96% of theoretical density), carbon impurity content (961–5240 ppm), oxygen content (≤ ∼2000 ppm), and grain size (2.5–24 μm). The irradiation matrix spans nominal fuel temperatures of 873 K, 1173 K, and 1473 K and target burnups of 3.75%, 6.0%, and 7.5% fissions per initial metal atom (FIMA). Neutronic and thermal analyses were performed to define specimen-specific burnup accumulation and temperature histories, establishing the boundary conditions for subsequent in-pile behavior. Comprehensive pre-irradiation characterization—including dimensional metrology, density verification, impurity analysis, X-ray diffraction, Raman spectroscopy, scanning electron microscopy, X-ray computed tomography, and confocal profilometry—provides a detailed baseline for post-irradiation examination. Pre-irradiation data were further used to generate predictive estimates of fission gas release and swelling using existing empirical correlations. This quantitative comparison reveals substantial inter-model divergence at intermediate and elevated temperatures that exceeds propagated input uncertainties, highlighting structural gaps in the historical irradiation database. The ROADRUNNER irradiation campaign is currently underway in HFIR, with initial firs cycle completed in late 2025 and remaining targets scheduled through 2027. The experimental design and baseline dataset presented here establish the framework needed to interpret forthcoming post-irradiation measurements and to provide discriminating data for the validation and refinement of physics-based UN fuel performance models.

Lopes, Denise Adorno [Oak Ridge National Laborator↗

High Throughput In-Line Coating Metrology Development for Solid Oxide Fuel Cell Manufacturing

Coatings play key roles in solid oxide fuel cell (SOFC) stack durability. For example, diffusion barrier coatings on Cr-containing interconnect and balance of plant (BOP) components protect electrodes from Cr poisoning over the long operational lifetimes (>10,000 hours) of the fuel cell stack. Common defects in coatings, such as cracks, pinholes, and porosity, result in a failure to protect the electrodes, resulting in shorter operational lifetime and thus higher cost. It is very unlikely, even in the best coating process, that all these defects can be mitigated, hence identifying critical defects in parts, and removing defective parts from production before they can damage the stack, becomes paramount. Furthermore, these quality control techniques must be operational in the production/assembly line (in-line), i.e., high throughput and non-destructive, and cost effective. Redox Power Systems, LLC (Redox) together with the National Renewable Energy Laboratory (NREL) developed much needed high throughput, in-line metrology techniques for protective coatings. The overall goal of the project is to lower cost while increasing robustness, reliability, and endurance of SOFC stacks. To accomplish this, we had several objectives, including: to identify key coating and substrate defects that lead to coating failure through the use of detailed characterization methods (e.g., microscopy, XRD, EDS, electrochemistry); to assess capabilities of in-line metrology techniques, e.g., optical profilometry (Redox) and thermography (NREL), to probe these defects, or evidence thereof; demonstrate long-term performance of “defect-free” protective coatings, as identified by in-line metrology, in solid oxide fuel cell (SOFC) stack operation. In the first part of this project, the ability to identify key defects expected to lead to coating and SOFC degradation using in-line metrology tools were evaluated. Coated interconnect samples with controlled defect types and populations were tested under conditions similar to SOFC operation, followed by detailed post-test analysis to reveal the defects responsible for observed degradation. In the second part of the project, the optimal in-line metrology techniques and methodologies were used to map the defect distribution in full-size interconnects with critical defects intentionally allowed to exist in some cases. These interconnects underwent SOFC testing for extended periods (up to ~3,000 hours) followed by post-test analysis to evaluate the effectiveness of in-line metrology techniques in mitigating MCO coating related degradation. Key accomplishments in this project included the following: Demonstrated ASR of < 0.05 ohm-cm 2 at 650 °C for 1,000 hours with low defect (determined by in-line metrology) interconnect samples (average ASR=37 milliohms-cm 2 after over 1,000 hours). Demonstrated that low defect coatings on interconnects (as screened using in-line metrology) have low volatilization of chromium at ~650 °C for 1,000 hours as detected using Cr-getter material (< 5 at% increase above baseline); 1022 hour duration tests under humidified, elevated temperature (750 °C rather than 650 °C) compared a base case against different coating thicknesses. Demonstrated capability to identify initial key defects of interest with in-line metrology techniques using up to 8 cm by 10 cm having coatings with and without intentional defects of interest using thermal imaging and optical profilometry. Correlated key defects identified using metrology techniques with observed coating performance (e.g., ASR and Cr volatility). Conducted several 4 cm by 4 cm cell tests using MCO-interconnects that were pre-screened using some of the metrology techniques developed in the project (e.g., optical profilometry). An analysis of ASR measurements were able to show that defect-free coatings resulted in the anticipated performance in the cell tests.

01 COAL, LIGNITE, AND PEAT↗

Performance of the Primary Mirror Center-of-Curvature Optical Metrology System during Cryogenic Testing of the JWST Pathfinder Telescope

The JWST primary mirror consists of 18 1.5 m hexagonal segments, each with 6-DoF and RoC adjustment. The telescope will be tested at its cryogenic operating temperature at Johnson Space Center. The testing will include center-of-curvature measurements of the PM, using the Center-of-Curvature Optical Assembly (COCOA) and the Absolute Distance Meter Assembly (ADMA). The performance of these metrology systems, including hardware, software, procedures, was assessed during two cryogenic tests at JSC, using the JWST Pathfinder telescope. This paper describes the test setup, the testing performed, and the resulting metrology system performance.

JWST↗