Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Taylor impact test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

58 records · Page 4

Accelerated Aging Humidity Chamber for Nuclear Grade HEPA Filter Media

A unique accelerated aging humidity chamber for simulating the natural aging process of nuclear grade high efficiency particulate air (HEPA) filter media is being designed, implemented, and tested. The nuclear industry currently lacks information regarding the shelf life and service life of HEPA filter media. The Department of Energy recommends disposing of HEPA filters 10 years after the manufacture date for filters operated under dry conditions. Studies have shown the tensile strength and water repellency of HEPA filter media diminish with age. The chamber's principal function is to sustain an elevated relative humidity condition for an extended duration specified by the Arrhenius aging model. To accomplish this, various design parameters were established: (1) consistently achieve uniform humidity conditions within the chamber to equally expose media sheets, (2) ensure the chamber is sufficiently sealed to mitigate the uncontrolled infiltration of air, (3) confidently secure the media sheets to avert the introduction of unnecessary stressing/creasing, (4) fabricate the chamber from clear polycarbonate material to allow inspection of the media sheets, (5) provide a safe and ergonomic design for personnel, (6) ensure the chamber design is replicable and relatively easy to fabricate/assemble. A humidity source, fan, PID controller, humidity and temperature transmitters, and data loggers are required for proper operation and control of the chamber. The humidity source must accommodate target values up to 95% relative humidity throughout the chamber. The three humidity and temperature transmitters are strategically spaced throughout the chamber to ensure uniform conditions. The 10 cubic feet per minute (CFM) fan selected intends to accomplish the desired air change rate inside the chamber of approximately 20 air changes per hour (ACH). The 2 plenums on the upper and lower portions of the chamber utilize a perforated design to uniformly distribute air, promote air mixing, and control the air velocity entering the chamber. Industrial blueprint hanging clamps are being retrofitted to be seated within the chamber drawers and firmly secure the nuclear grade filter media. The aged media will be evaluated using autopsy methodology, and the results obtained intend to help clarify the useful life of nuclear grade HEPA filters. Nuclear grade high efficiency particulate air (HEPA) filters are defined as disposable, extended-media, dry-type filters with a rigid casing enclosing the full depth of the pleats and have a minimum particle removal efficiency of 99.97%. [1] - HEPA filters are constantly exposed to stressors and subsequently have been shown to degrade as the filter ages. Properties such as tensile strength and water repellency, along with others, are negatively impacted. [2] - Due to the scarcity of naturally aged HEPA filters available, it is crucial to develop accelerated aging methods which effectively mimic the natural degradation effects. - After accelerated aging, the filters are subject to testing in the Axial Flow Large Scale Test Stand (ALSTS) and other analysis techniques such as the same qualification tests performed directly after being manufactured. - Quality data is necessary for future decisions regarding the lifetime of nuclear grade HEPA filters. - The objective is to develop a prototype accelerated aging humidity chamber for nuclear grade HEPA filter media. The chamber should expose the media to commonly occurring stressors to expedite the degradation process caused by aging. PID yields reliable and reproducible results: - CFD model correlates well with actual performance; - Further analysis is needed to complete characterization; - Future work for the chamber is still to be completed. The data shown in Figure 5 and Table 1 indicate the system is functioning as designed. As can be determined from the system response evaluation in Table 1, the PID controller is yielding reliable and reproducible results at each set point. As the set point increases, the time constant and 20% settling time increase accordingly. From the results in Table 1, it stands to reason that the CFD model correlates well with the actual performance of the system. Each system response parameter for the 90%RH* CFD model is slightly lower than the parameters collected from the physical model tested at an equivalent set point. This is to be expected considering the inlet in the CFD model is a constant supply of water vapor, whereas the physical model uses a PID controller to monitor the amount of water vapor needed and reacts accordingly. More analysis is still to be done on the prototype chamber. A pressure test will be conducted in order to determine the hourly leak rate of the chamber. This test will involve constant air flow into the chamber until the desired pressure is reached. A uniformity test will also be conducted in order to ensure each filter medium is being exposed to equivalent relative humidity levels. This test will involve an array of humidity meters strategically oriented inside the chamber to record any possible gradients. Future work for the chamber includes dehumidification abilities, tests while fully loaded with filters, and temperature control. Once completed, the autopsy team at Institute of Clean Energy Technology will conduct necessary accelerated aging studies as needed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Experimental Testing of Particle Erosion and Attrition in CSP Systems

In CSP systems using solid particles for heat transfer, erosion from the falling particles can damage the system components upon impact, and from sliding against the component walls. Furthermore, the resulting attrition of particles can change the thermal performance due to alterations in particle morphology. The research on these issues has been limited to industrial applications, and don’t necessarily coincide with the operating conditions in CSP systems. In this work, we investigated the durability of the particles selected as the heat transfer media, as well as special substrate materials that are of interest as lining materials to the particle storage tanks and hoppers. Three different erosion phenomena were studied: impact, abrasion, and attrition erosion. The low-temperature experiments revealed negligible losses from attrition and abrasion erosion. Although the substrates indicated visible surface damage from impact erosion, the actual material mass loss was small even after a throughput of 500kg of particles 63 days of 1MW CSP plant operation assuming 14 hours per day of operation. Erosion is typically classified as impact, abrasion, or attrition erosion. For example, the CSP systems utilizing solid particles as heat transfer media will likely experience impact erosion on the receiver hopper and heat exchanger walls as the solid particles fall from the reservoir. Additionally, there will be sliding erosion along the receiver walls as particles move through the hopper, and lastly, there will also be attrition erosion as the particles rub against each other. The extent of erosion depends on many factors including but not limited to particle shape and size, material hardness/brittleness and ductility, and particle impact speed and angle. Mechanistic erosion equations that are available in the literature are mostly derived from data pertaining to specific experiments and therefore can’t be applied to all applications without suitable adjustments. Survey of the literature relating to particle-based receivers revealed that the most prevalent approach has been to choose low velocities to limit erosion, but to our knowledge, little effort has been put in to fully characterize erosion at the expected operating conditions. A relatively recent work investigated the erosion of wire mesh proposed for use in a particle receiver, where the results actually showed an increase in mass as oxidation occurred on the mesh surface but the work did not investigate the particle attrition rate, and the erosion rate of a solid substrate. The end goal of this work is to develop a comprehensive particle and substrate durability model that will allow a comprehensive understanding of particle-based CSP operating conditions on component durability.

14 SOLAR ENERGY↗

Towards provision of regularly updated climate data from the Coupled Model Intercomparison Project

The Coupled Model Intercomparison Project (CMIP) is a flagship of the World Climate Research Programme (WCRP). CMIP has become a recognised ‘brand’ in climate circles evolving over the last thirty years from a targeted research activity by a small number of climate modelling centres intercomparing their Earth System Model (ESM) simulations to a broad international coordinated research effort (Durack et al, 2025). CMIP is organized as a research activity leveraging funded and in-kind contributions from experts within modelling centres and the broader scientific community supported more recently by a fully-funded International Project Office. Within CMIP, Model Intercomparison Projects (MIPs) are community-designed to understand past, present and future climate. CMIP data provides a valuable resource for climate research and is routinely used to assess model representation of climate processes and test scientific hypotheses in the context of model uncertainty and (forced and internal) variability as evident from its prolific use in scientific publications1 . The impact relies on enabling infrastructure (most prominently via the Earth System Grid Federation (ESGF)), which allows sharing of simulation output, provision of the boundary conditions used in each simulation, and definition of the data standards that are essential to facilitating wide use of the data. The impact is supplemented by the wide-ranging scrutiny to which model simulations are subjected. Beyond its use in research, CMIP data is a key resource for communities producing derived climate information from downscaling and impact studies, such as the Coordinated Regional Downscaling Experiment (CORDEX; Gutowski et al., 2016) and the Intersectoral Impacts MIP (ISIMIP; Frieler et al., 2024). Government, academic and commercial entities also increasingly rely on CMIP and its downstream data for climate risk assessments and climate services (for example, Copernicus Climate Change Service and World Bank portal). This means that, although CMIP is a research activity, it increasingly serves a secondary and very relevant role as a provider of climate data – a long-recognised dichotomy (Stevens, 2024). Research and applications have distinct needs, with the former requiring flexibility and generality and the latter consistency. Here we explain how the design of the research activity has been adapted to reduce the burdens imposed by applications and how the research infrastructure might evolve to further enable scientific inquiry. We propose one possible approach to consistently providing model information and projections for applications in the future.

Environmental sciences↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗