Transition-radiation-Compton-scattering detector for very relativistic nuclei

The paper presents the design and predicted performance of a large acceptance (2 sq m sr) transition-radiation-Compton-scattering detector system which can be used to measure energy spectra up to several thousand Gev/nucleon for nuclei with Z between 6 and 28, as well as up to 40,000 GeV/nucleon for He. The following circumstances made such a detector system practicable: (1) transition radiation output is proportional to the square of particle charge; (2) output varies at least as rapidly as the square of Lorentz factor over the range from several hundred to several thousand.

Osborne, W. Z.↗

Peculiarities of the spectral-angular distribution of transition radiation from a relativistic particle in a dihedral angle

The spatial distributions of transition radiation from relativistic particles entering and exiting the edge of a dihedral angle formed by perfectly conducting flat surfaces have been investigated. The angular distributions of the radiation intensity in dihedral angles with various opening angles have been calculated. The angular distributions of forward radiation (when the particle exits the dihedral angle) and backward radiation (when the particle enters the dihedral angle) are shown to differ significantly.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Single-shot electro-optic sampling of coherent transition radiation at the A0 Photoinjector

Future collider applications and present high-gradient laser plasma wakefield accelerators operating with picosecond bunch durations place a higher demand on the time resolution of bunch distribution diagnostics. This demand has led to significant advancements in the field of electro-optic sampling over the past ten years. These methods allow the probing of diagnostic light such as coherent transition radiation or the bunch wakefields with sub-picosecond time resolution. Potential applications in shot-to-shot, non-interceptive diagnostics continue to be pursued for live beam monitoring of collider and pump-probe experiments. Related to our developing work with electro-optic imaging, we present results on single-shot electro-optic sampling of the coherent transition radiation from bunches generated at the A0 photoinjector.

43 PARTICLE ACCELERATORS↗

Coherent transition radiation from a self-modulated charged particle beam

Plasma wakefield accelerator utilizing a TeV proton beam is a promising method to generate a TeV electron beam. However the length of the existing proton beam is too long compared with the proper plasma skin depth. As a result selfmodulation instability takes place after such a long pulse enters into the plasma. The transverse spot size of the long beam changes periodically in the longitudinal direction. Therefor measurement of the coherent transition radiation when the selfmodulated beam leaves the plasma is a possible method to demonstrate the self-modulation instability. In this paper, we analyze the angular spectrum of this coherent transition radiation when the beam comes from plasma to vacuum.

43 PARTICLE ACCELERATORS↗

Observation of optical transition radiation from electron beams generated by laser plasma accelerator

Laser plasma accelerators (LPAs) have made great progress, achieving electron beam with energy up to 1 GeV from a centimeter scale capillary plasma waveguide. Here in this work, we report the measurement of optical transition radiation (OTR) from the capillary-based LPA electron beams. Transition radiation images, produced by electrons passing through two separate foils (located at 2.3 m and 3.8 m away from the exit of the LPA) were recorded with a high resolution imaging system, respectively. Two magnetic quadrupole lenses were placed right after the capillary to focus and collimate the electron beams. Lastly, significant localized spikes appeared in the OTR images when the electron beam was focused by the magnetic quadrupole lenses, indicating the coherence of the radiation and the existence of ultrashort longitudinal structures inside the electron beam.

43 PARTICLE ACCELERATORS↗

Progress on the Flash X-Ray Optical Transition Radiation Diagnostic

This document summarizes the Flash X-Ray accelerator (FXR) optical transition radiation (OTR) spot-size diagnostics efforts in FY07. During this year, new analysis, simulation, and experimental approaches were utilized to interpret OTR spot data from both dielectric foils such as Kapton (VN type) and metal coated foils. Significant new findings of the intricacies involved in the diagnostic and of FXR operational issues were achieved. Geometry and temperature based effects were found to affect the beam image profiles from the OTR foils. These effects must be taken into account in order to deduce accurately the beam current density profile.

43 PARTICLE ACCELERATORS↗

Experimental study of coherent transition radiation from relativistic electrons in a dihedral angle

Angular intensity distributions for transition radiation excited by a beam of relativistic electrons in the emitter in the form of a dihedral angle are measured in the millimeter range. The angle is formed by the intersection of two conducting planes. The source of radiation is a microtron with an electron energy of 7.4 MeV. We analyze the effect of the magnitude of the dihedral angle of the emitter, the position of the electron transition point on the surface of the angle, and the direction of motion of electrons on the angular distribution of radiation intensity. It is shown that the spectral and angular distributions of radiation intensity in the dihedral angle substantially differ from analogous distributions for a particle intersecting a planar conducting surface. The possibility of using radiation to measure the energy, spatial position, and direction of motion of charges is considered.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Single-cycle terahertz pulses with >0.2 V/A field amplitudes via coherent transition radiation

We demonstrate terahertz pulses with field amplitudes exceeding 0.2 V/A generated by coherent transition radiation. Femtosecond, relativistic electron bunches generated at the Linac Coherent Light Source are passed through a beryllium foil, and the emitted radiation is characterized as a function of the bunch duration and charge. Broadband pulses centered at a frequency of 10 THz with energies of 140 {mu}J are measured. These far-below-bandgap pulses drive a nonlinear optical response in a silicon photodiode, with which we perform nonlinear autocorrelations that yield information regarding the terahertz temporal profile. Simulations of the spatiotemporal profile agree well with experimental results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Transition radiation in a dihedral angle formed by perfectly conducting planes

The spatial distribution of the field of transition radiation generated by a relativistic particle flying into a dihedral angle formed by perfectly conducting plane surfaces is determined. The cases when particles are injected from the edge and from a plane of the dihedral angle are considered. The angular distributions of radiation intensity in dihedral angles of different values are calculated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental study of coherent transition radiation from relativistic electron bunches entering a dihedral angle

The angular distributions of the intensity of transition radiation from a bunch of relativistic electrons entering a dihedral angle between two conducting planes have been measured in a millimeter wavelength range. A microtron with a particle energy of 7.4 MeV is used as a source of electrons. The effect of the particle injection direction and the magnitude of the dihedral angle on the angular distribution of the radiation intensity has been analyzed. The measurements show that the character of the distribution of radiation from a charge entering the dihedral angle significantly differs from that for a charge escaping the angle. A comparatively small change in the magnitude of the dihedral angle can lead to qualitative changes in the angular distribution of radiation from a charge entering the dihedral angle.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Plasma cutoff and enhancement of radiative transitions in dense stellar matter

We study plasma effects on radiative transitions (e.g., decay of excited states of atoms or atomic nuclei) in a dense plasma at the transition frequencies {omega} < or. approx {omega}{sub p} (where {omega}{sub p} is the electron plasma frequency). The decay goes through four channels - the emission of real transverse and longitudinal plasmons as well as the emission of virtual transverse and longitudinal plasmons with subsequent absorption of such plasmons by the plasma. The emission of real plasmons dies out at {omega}{<=}{omega}{sub p}, but the processes with virtual plasmons strongly enhance the radiative decay. Applications of these results to radiative processes in white dwarf cores and neutron star envelopes are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A novel coaxial Ku-band transit radiation oscillator without external guiding magnetic field

A novel coaxial transit radiation oscillator without external guiding magnetic field is designed to generate high power microwave at Ku-band. By using a coaxial structure, the space-charge potential energy is suppressed significantly, that is good for enhancing efficient beam-wave interaction. In order to improve the transmission stability of the unmagnetized intense relativistic electron beam, a Pierce-like cathode is employed in the novel device. By contrast with conventional relativistic microwave generators, this kind of device has the advantages of high stability, non-guiding magnetic field, and high efficiency. Moreover, with the coaxial design, it is possible to improve the power-handing capacity by increasing the radial dimension of the Ku-band device. With a 550 keV and 7.5 kA electron beam, a 1.25 GW microwave pulse at 12.08 GHz has been obtained in the simulation. The power conversion efficiency is about 30%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical transition radiation used in the diagnostic of low energy and low current electron beams in particle accelerators

Optical transition radiation (OTR) plays an important role in beam diagnostics for high energy particle accelerators. Its linear intensity with beam current is a great advantage as compared to fluorescent screens, which are subject to saturation. Moreover, the measurement of the angular distribution of the emitted radiation enables the determination of many beam parameters in a single observation point. However, few works deals with the application of OTR to monitor low energy beams. In this work we describe the design of an OTR based beam monitor used to measure the transverse beam charge distribution of the 1.9-MeV electron beam of the linac injector of the IFUSP microtron using a standard vision machine camera. The average beam current in pulsed operation mode is of the order of tens of nano-Amps. Low energy and low beam current make OTR observation difficult. To improve sensitivity, the beam incidence angle on the target was chosen to maximize the photon flux in the camera field-of-view. Measurements that assess OTR observation (linearity with beam current, polarization, and spectrum shape) are presented, as well as a typical 1.9-MeV electron beam charge distribution obtained from OTR. Some aspects of emittance measurement using this device are also discussed.

43 PARTICLE ACCELERATORS↗

Radiative transition probabilities and recombination coefficients of the ion C IV.

Bound-bound and bound-free radiative transition probabilities, as well as radiative recombination coefficients of the ion C IV, are computed with a semi-empirical polarization potential method. The nonhydrogenic probabilities and coefficients are given for all bound states of the ion up to the principal quantum number n = 7.

Leibowitz, E. M.↗

Coherent optical transition radiation and self-amplified spontaneous emission generated by chicane-compressed electron beams

Observations of strongly enhanced optical transition radiation (OTR) following significant bunch compression of photoinjector beams by a chicane have been reported during the commissioning of the Linac Coherent Light Source (LCLS) accelerator and recently at the Advanced Photon Source (APS) linac. These localized transverse spatial features involve signal enhancements of nearly a factor of 10 and 100 in the APS case at the 150-MeV and 375-MeV OTR stations, respectively. They are consistent with a coherent process seeded by noise and may be evidence of a longitudinal space charge (LSC) microbunching instability which leads to coherent OTR (COTR) emissions. Additionally, we suggest that localized transverse structure in the previous self-amplified spontaneous emission (SASE) free-electron laser (FEL) data at APS in the visible-UV regime as reported at FEL02 may be attributed to such beam structure entering the FEL undulators and inducing the SASE startup at those structures. Separate beam structures 120 microns apart in x and 2.9 nm apart in wavelength were reported. The details of these observations and operational parameters will be presented.

43 PARTICLE ACCELERATORS↗

Beam Characterization and Coherent Optical Transition Radiation Studies at the Advanced Photon Source Linac

The Advanced Photon Source facility includes a 450-MeV S-band linac with the option for injection from a photocathode (PC) rf gun. A diode-pumped, twice-frequency doubled Nd:glass regen laser (263 nm) is used with the Cu PC to generate the ele ctron beams. Characterization of these beams and studies of the microbunching instability following beam compression in the four-dipole magnetic chicane are described. A suite of diagnostics is employed including a three-screen emittance section, a FIR co herent transition radiation autocorrelator, electron spectrometers, and an optical diagnostics end station. An energy chirp impressed on the beam is used to compress the 1-2 ps, rms bunch as it passes through the chicane. With compression, bunch lengths o f 170-200 fs, rms at 450 pC are measured, and coherent optical transition radiation (COTR) due to the microbunching instability is observed. Mitigation techniques of the COTR in the beam profile diagnostics are demonstrated both spectrally and temporally. At 100 pC without compression normalized transverse emittances of 1.8 and 2.7 microns are observed in the x and y planes, in reasonable agreement with initial ASTRA simulations.

43 PARTICLE ACCELERATORS↗

Diffracted transition radiation of an ultra-high-energy relativistic electron beam in a thin single-crystal wafer

We consider diffracted transition radiation (DTR) emitted by high-energy relativistic electrons crossing a thin single-crystal wafer in the Laue geometry. The expression describing the DTR angular density is derived for the case where the electron path length in the target is much smaller than the X-ray wave extinction length in the crystal and the kinematic nature of this expression is demonstrated. It is shown that the DTR angular density in a thin target is proportional to the target thickness.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multi Optical Transition Radiation System for ATF2

In this paper we describe the design, installation and first calibration tests of a Multi Optical Transition Radiation System in the beam diagnostic section of the Extraction (EXT) line of ATF2, close to the multi wire scanner system. This system will be a valuable tool for measuring beam sizes and emittances coming from the ATF Damping Ring. With an optical resolution of about 2 {micro}m an original OTR design (OTR1X) located after the septum at the entrance of the EXT line demonstrated the ability to measure a 5.5 {micro}m beam size in one beam pulse and to take many fast measurements. This gives the OTR the ability to measure the beam emittance with high statistics, giving a low error and a good understanding of emittance jitter. Furthermore the nearby wire scanners will be a definitive test of the OTR as a beam emittance diagnostic device. The multi-OTR system design proposed here is based on the existing OTR1X.

43 PARTICLE ACCELERATORS↗