Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TOMOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

High-energy synchrotron X-ray multimodal computed tomography: enabling multiscale materials characterization at NSLS-II

We report the commissioning of a multimodal computed tomography experimental setup at the 28-ID-2 (XPD) beamline of the National Synchrotron Light Source II. This high-energy (>60 keV) resource features a tunable X-ray beam size ranging from several millimetres to a few micrometres and enables comprehensive characterization of high-Z materials—an essential capability for nuclear and advanced materials research. It provides four complementary computed tomography modalities: X-ray absorption, X-ray fluorescence, X-ray diffraction, and pair distribution function tomography. A case study using a custom-made heterogeneous sample demonstrates these abilities to simultaneously capture atomic, elemental, and morphological information. This unique combination of imaging, structural, and chemical sensitive methods provides a holistic approach to study complex materials with amorphous and crystalline systems across multiple length scales.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Efficient and Flexible Sensitivity Matrix Computation for Adaptive Electrical Capacitance Volume Tomography

Electrical capacitance tomography is a widely used sensor modality for flow imaging in many industrial settings. Adaptive Electrical Capacitance Volume Tomography (AECVT) extends the capabilities of traditional ECT by enabling direct volumetric imaging and an improved resolution. Construction of the sensitivity matrix is a necessary step to obtain flow images. This step requires computation of the electric field inside the sensing domain, which is done via a typical field solver such as the finite element method. In this work, we present an efficient and flexible method to construct the sensitivity matrix for Adaptive Electrical Capacitance Volume Tomography (AECVT) based on individual electrode segment excitations and their judicious combination to form desired matrix elements. We illustrate how the proposed method yields the same sensitivity matrix as the traditional method but at a much lower computational cost. Once all segment contributions are obtained, we also indicate how the proposed method, unlike the traditional approach, can generate the sensitivity matrix on demand for an arbitrary combination of synthetic electrodes and obviating the need for any additional field computations. Finally, we present image reconstruction results for two different experimental scenarios where the mutual capacitance data and the corresponding sensitivity vectors are obtained through the proposed measurement combination scheme.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Computed Tomography Automation Architecture Developed from a Comprehensive Literature Review

This paper presents a literature review on techniques related to the computed tomography procedure that incorporate automation elements in their research investigations or industrial applications. Computed tomography (CT) is a non-destructive testing (NDT) technique in that the imaging and inspection are performed without damaging the sample, allowing for additional or repeated analysis if necessary. The reviewed literature is organized based on the steps associated with a general NDT task in order to define an end-to-end computed tomography automation architecture. The process steps include activities prior to image collection, during the scan, and after the data are collected. It further reviews efforts related to repeating this process based on a previous scan result. By analyzing the multiple existing but disparate efforts found in the literature, we present a framework for fully automating NDT procedures and discuss the remaining technical gaps in the developed framework.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Turbulence-induced bias in time-averaged laser absorption tomography of correlated concentration and temperature fields with a first-order correction

The influence of correlated scalar fluctuations on time-averaged laser absorption tomography measurements of temperature and species in a piloted turbulent premixed flame was examined using a coupled spectroscopic and fluid-dynamic analysis. To understand bias associated with turbulence, spatio-temporally resolved temperature and species mole fraction profiles predicted by large eddy simulations (LES) were used to synthetically generate time-resolved line-of-sight absorption measurements at short time scales (microsecond) to reflect the unsteady nature of a canonical jet burner across various transverse measurement planes. Inversion methods were employed on the time-averaged line-of-sight data to produce radially-resolved temperature and mole fraction profiles, analogous to those produced by laser absorption tomography performed on a time-averaged axisymmetric flowfield. It is shown that bias in the measurements compared to true time-averaged scalar fields is a function primarily of temperature dependence in absorptivity and non-zero correlation between temperature and species concentration scalars. Finally, a first-order correction to tomography measurements is proposed to account for the bias based on estimated correlations and the known spectroscopic parameters of the probed absorption transitions.

42 ENGINEERING↗

Solving complex nanostructures with ptychographic atomic electron tomography

Abstract Transmission electron microscopy (TEM) is essential for determining atomic scale structures in structural biology and materials science. In structural biology, three-dimensional structures of proteins are routinely determined from thousands of identical particles using phase-contrast TEM. In materials science, three-dimensional atomic structures of complex nanomaterials have been determined using atomic electron tomography (AET). However, neither of these methods can determine the three-dimensional atomic structure of heterogeneous nanomaterials containing light elements. Here, we perform ptychographic electron tomography from 34.5 million diffraction patterns to reconstruct an atomic resolution tilt series of a double wall-carbon nanotube (DW-CNT) encapsulating a complex ZrTe sandwich structure. Class averaging the resulting tilt series images and subpixel localization of the atomic peaks reveals a Zr 11 Te 50 structure containing a previously unobserved ZrTe 2 phase in the core. The experimental realization of atomic resolution ptychographic electron tomography will allow for the structural determination of a wide range of beam-sensitive nanomaterials containing light elements.

36 MATERIALS SCIENCE↗

A machine learning decision criterion for reducing scan time for hyperspectral neutron computed tomography systems

We present the first machine learning-based autonomous hyperspectral neutron computed tomography experiment performed at the Spallation Neutron Source. Hyperspectral neutron computed tomography allows the characterization of samples by enabling the reconstruction of crystallographic information and elemental/isotopic composition of objects relevant to materials science. High quality reconstructions using traditional algorithms such as the filtered back projection require a high signal-to-noise ratio across a wide wavelength range combined with a large number of projections. This results in scan times of several days to acquire hundreds of hyperspectral projections, during which end users have minimal feedback. To address these challenges, a golden ratio scanning protocol combined with model-based image reconstruction algorithms have been proposed. This novel approach enables high quality real-time reconstructions from streaming experimental data, thus providing feedback to users, while requiring fewer yet a fixed number of projections compared to the filtered back projection method. In this paper, we propose a novel machine learning criterion that can terminate a streaming neutron tomography scan once sufficient information is obtained based on the current set of measurements. Our decision criterion uses a quality score which combines a reference-free image quality metric computed using a pre-trained deep neural network with a metric that measures differences between consecutive reconstructions. The results show that our method can reduce the measurement time by approximately a factor of five compared to a baseline method based on filtered back projection for the samples we studied while automatically terminating the scans.

97 MATHEMATICS AND COMPUTING↗

Sub-10 second fly-scan nano-tomography using machine learning

Abstract X-ray computed tomography is a versatile technique for 3D structure characterization. However, conventional reconstruction algorithms require that the sample not change throughout the scan, and the timescale of sample dynamics must be longer than the data acquisition time to fulfill the stable sample requirement. Meanwhile, concerns about X-ray-induced parasite reaction and sample damage have driven research efforts to reduce beam dosage. Here, we report a machine-learning-based image processing method that can significantly reduce data acquisition time and X-ray dose, outperforming conventional approaches like Filtered-Back Projection, maximum-likelihood, and model-based maximum-a-posteriori probability. Applying machine learning, we achieve ultrafast nano-tomography with sub-10 second data acquisition time and sub-50 nm pixel resolution in a transmission X-ray microscope. We apply our algorithm to study dynamic morphology changes in a lithium-ion battery cathode under a heating rate of 50 o C min −1 , revealing crack self-healing during thermal annealing. The proposed method can be applied to various tomography modalities.

36 MATERIALS SCIENCE↗

An automated fast neutron computed tomography instrument with on-line focusing for non-destructive evaluation

A fast neutron tomography imaging instrument has been designed, built, and tested at The Ohio State University 500 kW Research Reactor on a fast neutron beamline with a peak neutron flux ≈5.4 × 107 n·cm−2·s−1 at 1.6 MeV median neutron energy. The instrument and beamline are also configurable for thermal neutron imaging. The imaging apparatus is composed of a lens coupled, water-cooled Electron Multiplying Charge Coupled Device camera, a front-surface mirror, and a high light yield plastic Polyvinyl toluene scintillator. The instrument sits on a mobile cart. A total of 5 motion-control stages are built into the system for XYZ and rotational degrees of freedom for sample positioning; the fifth stage fine tunes the focal distance between the camera and the scintillator to achieve on-line focusing. A Python code with a user-friendly graphical user interface controls the fully automated image acquisition, not requiring user interaction, yet facilitating tracking of the image acquisition. A complete fast neutron computed tomography dataset with 360 projections requires less than 3 h, with 30 s per projection. On-line focusing is accomplished with a commercial, off-the-shelf, dielectrically actuated liquid lens. Finally, tomographic reconstructions are visualized using the Livermore Tomography Tools software package. The effective pixel size (width and height) is ≈0.1058 mm, yielding a minimum voxel size of 0.1058 × 0.1058 × 0.1058 mm3, and produces a spatial resolution of 231 μm when calculated from knife-edge measurements.

Bisbee, M. G. (ORCID:0000000313466697)↗

Asymmetric jet shapes with two-dimensional jet tomography

Two-dimensional (2D) jet tomography is a promising tool to study jet medium modification in high-energy heavy-ion collisions. It combines gradient (transverse) and longitudinal jet tomography for selection of events with localized initial jet production positions. It exploits the transverse asymmetry and energy loss that depend, respectively, on the transverse gradient and jet path length inside the quark-gluon plasma (QGP). In this study, we employ 2D jet tomography to study medium modification of the jet shape of γ -triggered jets within the linear Boltzmann transport (LBT) model for jet propagation in heavy-ion collisions. Our results show that jets with small transverse asymmetry ( A N n ⃗ ) or small γ -jet asymmetry ( x J γ = p T jet / p T γ ) exhibit a broader jet shape than those with larger A N n ⃗ or x J γ , since the former are produced at the center and go through longer path lengths while the later are off center and close to the surface of the QGP fireball. In events with finite values of A N n ⃗ , jet shapes are asymmetric with respect to the event plane. Hard partons at the core of the jet are deflected away from the denser region while soft partons from the medium response at large angles flow toward the denser part of QGP. Future experimental measurements of these asymmetric features of the jet shape can be used to study the transport properties of jets and medium responses. Published by the American Physical Society 2024

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Classical shadows for quantum process tomography on near-term quantum computers

Quantum process tomography is a powerful tool for understanding quantum channels and characterizing the properties of quantum devices. Inspired by recent advances using classical shadows in quantum state tomography [H.-Y. Huang, R. Kueng, and J. Preskill, .], we have developed ShadowQPT, a classical shadow method for quantum process tomography. We introduce two related formulations with and without ancilla qubits. ShadowQPT stochastically reconstructs the Choi matrix of the device allowing for an classical evaluation of the device on arbitrary inputs with respect to arbitrary outputs. Using shadows, we then show how to compute overlaps, generate all k -weight reduced processes, and perform reconstruction via Hamiltonian learning. These latter two tasks are efficient for large systems as the number of quantum measurements needed scales only logarithmically with the number of qubits. A number of additional approximations and improvements are developed, including the use of a pair-factorized Clifford shadow and a series of postprocessing techniques that significantly enhance the accuracy for recovering the quantum channel. We have implemented ShadowQPT using both Pauli and Clifford measurements on the IonQ trapped ion quantum computer for quantum processes up to n = 4 qubits, and we achieved good performance. Published by the American Physical Society 2024

Levy, Ryan (ORCID:0000000349527156)↗

Grazing-incidence X-ray diffraction tomography for characterizing organic thin films

Characterization of thin films is of paramount importance for evaluating material processing outcomes/efficiency as well as establishing structure–property/performance relationships. This article introduces grazing-incidence diffraction tomography (GID tomography), a technique that combines grazing-incidence X-ray scattering and computed tomography to quantitatively determine the dimension and orientation of crystalline domains in thin films without restrictions on the beam coherence, substrate type or film thickness. This computational method extends the capability of synchrotron beamlines by utilizing standard X-ray scattering experiment setups.

36 MATERIALS SCIENCE↗

Cross-Modal Guidance for Fast Diffusion-Based Computed Tomography

Diffusion models have emerged as powerful priors for solving inverse problems in computed tomography (CT). In certain applications, such as neutron CT, it can be expensive to collect large amounts of measurements even for a single scan leading to sparse data sets from which it is challenging to obtain high quality reconstructions even with diffusion models. One strategy to mitigate this challenge is to leverage a complementary, easily available imaging modality; however, such approaches typically require retraining the diffusion model with large datasets. In this work, we propose incorporating an additional modality without retraining the diffusion prior, enabling accelerated imaging of costly modalities. We further examine the impact of imperfect side modalities on cross-modal guidance. Our method is evaluated on sparse-view neutron computed tomography, where reconstruction quality is substantially improved by incorporating X-ray computed tomography of the same samples.

Efimov, Timofey [ORNL] (ORCID:000900090098471X)↗

Seismic Tomography 2024

Seismic tomography is the most abundant source of information about the internal structure of the Earth at scales ranging from a few meters to thousands of kilometers. It constrains the properties of active volcanoes, earthquake fault zones, deep reservoirs and storage sites, glaciers and ice sheets, or the entire globe. It contributes to outstanding societal problems related to natural hazards, resource exploration, underground storage, and many more. The recent advances in seismic tomography are being translated to nondestructive testing, medical ultrasound, and helioseismology. Nearly 50 yr after its first successful applications, this article offers a snapshot of modern seismic tomography. Focused on major challenges and particularly promising research directions, it is intended to guide both Earth science professionals and early-career scientists. The individual contributions by the coauthors provide diverse perspectives on topics that may at first seem disconnected but are closely tied together by a few coherent threads: multiparameter inversion for properties related to dynamic processes, data quality, and geographic coverage, uncertainty quantification that is useful for geologic interpretation, new formulations of tomographic inverse problems that address concrete geologic questions more directly, and the presentation and quantitative comparison of tomographic models. Finally, it remains to be seen which of these problems will be considered solved, solved to some extent, or practically unsolvable over the next decade.

58 GEOSCIENCES↗

Ultra-High-Speed X-ray Tomography: Bridging the Gaps to See the Unknown

Rapid, time-varying, three-dimensional physics underpin numerous engineering challenges. Often, these physics occur within opaque environments, internal to a component, severely limiting applicable diagnostics. Development of novel diagnostics is necessary to understand and predict transient three-dimensional (3D) phenomena within opaque environments. This report highlights progress in four key areas leading to advancements in high-speed X-ray radiography and tomography. The first area is enabling MHz-rate imaging of energetics at the Advanced Photon Source at Argonne National Laboratory. The second is modeling a high-flux, rotating-anode X-ray source to understand the heat loads on the anode. The third effort was to develop a novel reconstruction algorithm that is validated by ground experimental tomography data and synthetic tomography data. The fourth is the development of a novel approach to two-color X-ray imaging.

42 ENGINEERING↗

Experimental Investigation of Cavitation-Induced Erosion Using X-Ray Imaging and Tomography

High injection pressure in diesel engines can lead to cavitation-induced erosion in injector nozzles. One important factor affecting the severity of erosion is the fuel and its properties. Traditionally, modeling and simulation studies have used single-component representations of fuels, but realistic fuels feature a multitude of components and can even include volatile additives such as water and alcohol. To provide realistic benchmarks and comparisons, experimental measurements quantifying erosion characteristics were made using ultra-low sulfur diesel (ULSD) and two alternative diesel fuels (ADF). X-ray imaging and computed tomography were used to investigate cavitation-induced erosion onset and progression. Hard X-ray tomography revealed injector internal geometry, including details such as surface marks from the manufacturing process and erosion patterns from repeated injections. Erosion progression was measured using X-ray tomography and imaging performed between injections. The critical erosion site was found to be similar across different fuel blends, while the erosion rate and incubation time were sensitive to the fuel blend. The injector geometry and the erosion characteristics were also prepared for numerical model development and validation.

42 ENGINEERING↗

First experimental study of multiple orientation muon tomography, with image optimization in sparse data environments

Due to the high penetrating power of cosmic ray muons, they can be used to probe very thick and dense objects. As charged particles, they can be tracked by ionization detectors, determining the position and direction of the muons. With detectors on either side of an object, particle direction changes can be used to extract scattering information within an object. This can be used to produce a scattering intensity image within the object related to density and atomic number. Such imaging is typically performed with a single detector-object orientation, taking advantage of the more intense downward flux of muons, producing planar imaging with some depth-of-field information in the third dimension. Several simulation studies have been published with multi-orientation tomography, which can form a three-dimensional representation faster than a single orientation view. In this work we present the first experimental multiple orientation muon tomography study. Experimental muon-scatter based tomography was performed using a concrete filled steel drum with several different metal wedges inside, between detector planes. Data was collected from different detector-object orientations by rotating the steel drum. The data collected from each orientation were then combined using two different tomographic methods. Results showed that using a combination of multiple depth-of-field reconstructions, rather than a traditional inverse Radon transform approach used for CT, resulted in more useful images for sparser data. As cosmic ray muon flux imaging is rate limited, the imaging techniques were compared for sparse data. Using the combined depth-of-field reconstruction technique, fewer detector-object orientations were needed to reconstruct images that could be used to differentiate the metal wedge compositions.

Applied Physics (physics.app-ph)↗

Multi-frequency electrical impedance tomography

Apparatus includes a plurality of geological subsurface electrical line sensors spaced apart from each other proximate a predetermined geological subsurface region of interest, with at least one of the electrical line sensors situated as a line source to produce a multi-frequency electrical impedance tomography source signal, and with at least one of the electrical line sensors situated as a line detector to receive the multi-frequency electrical impedance tomography response signal associated with the source signal that propagates through the predetermined geological subsurface region of interest, and a controller including a processor and a memory configured with instructions that, when executed by the processor, cause the processor to determine an electrical mapping over the predetermined geological subsurface region of interest based on the multi-frequency electrical impedance tomography source signal, response signal, and the spatial positions of the geological subsurface electrical line sensors.

Karra, Satish↗

Ultrasound waveform tomography with spatial and edge regularization

Synthetic-aperture ultrasound tomography systems and methods using scanning arrays and algorithms configured to simultaneously acquire ultrasound transmission and reflection data, and process the data for improved ultrasound tomography imaging, wherein the tomography imaging comprises total-variation regularization, or a modified total variation regularization, particularly with edge-guided or spatially variant regularization.

Huang, Lianjie↗