Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIME RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Relativistic electron flux comparisons at low and high altitudes with fast time resolution and broad spatial coverage

Analyses are presented for the first high-time resolution multisatellite study of the spatial and temporal characteristics of a relativistic electron enhancement event with a rapid onset. Measurements of MeV electrons were made from two low-altitude polar orbiting satellites and three spacecraft at synchronous altitude. The electron fluxes observed by the low-altitude satellites include precipitating electrons in both the bounce and drift loss cones as well as electrons that are stably trapped, whereas the observations at geosynchronous altitude are dominated by the trapped population. The fluxes of greater than 1 MeV electrons at low-satellite altitude over a wide range of L shells tracked very well the fluxes greater than 0.93 MeV at synchronous altitude.

Imhof, W. L.↗

A pulse-front-tilt–compensated streaked optical spectrometer with high throughput and picosecond time resolution

A high-throughput, broadband optical spectrometer coupled to the Rochester optical streak system equipped with a Photonis P820 streak tube was designed to record time-resolved spectra with 1-ps time resolution. Spectral resolution of 0.8 nm is achieved over a wavelength coverage range of 480 to 580 nm, using a 300-groove/mm diffraction grating in conjunction with a pair of 225-mm-focal-length doublets operating at an f/2.9 aperture. Overall pulse-front tilt across the beam diameter generated by the diffraction grating is reduced by preferentially delaying discrete segments of the collimated input beam using a 34-element reflective echelon optic. The introduced delay temporally aligns the beam segments and the net pulse-front tilt is limited to the accumulation across an individual sub-element. The resulting spectrometer design balances resolving power and pulse-front tilt while maintaining high throughput.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-time resolution measurements of solar wind heavy ions with SOHO/CELIAS/CTOF

The Charge Time-Of-Flight (CTOF) mass spectrometer as part of the Charge, ELement and Isotope Analysis System (CELIAS) onboard the SOlar and Heliospheric Observatory (SOHO) is designed to measure the kinetic properties and elemental/ionic composition of solar wind ions heavier than protons, which we refer to as heavy ions. This is achieved by the combined measurements of the energy-per-charge, the time-of-flight and the energy of incident ions. The CTOF instrument combines a remarkable time-of-flight resolution with a large effective area and a high measurement cadence. This allows to determine the Velocity Distribution Functions (VDFs) of a wide range of heavy ions with 5-minute time resolution which ensures that the complete VDF is measured under nearly identical solar wind and magnetic field conditions. For the measurement period between Day Of Year (DOY) 150 and 220 in 1996, which covers a large part of the instrument’s short life time, we analyzed VDFs of solar wind iron Fe{sup 8+}, Fe{sup 9+} and Fe{sup 10+} for differential streaming relative to the solar wind proton speed measured simultaneously with the CELIAS Proton Monitor (PM). We find an increasing differential streaming with increasing solar wind proton speed for all investigated ions up to ion-proton velocity differences of 30 - 50 km s{sup −1} at proton velocities of 500 km s{sup −1}, which is contradictory to an earlier CTOF study by [7]. We believe this difference is because in this study we used raw Pulse Height Analysis (PHA) data with a significantly increased mass and mass-per-charge resolution compared to the earlier used onboard preprocessed data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High time-resolution photodetectors for PET applications

This paper describes recent developments aiming at the improvement of the time resolution of photodetectors used in positron emission tomography (PET). Promising photodetector candidates for future PET-time-of-flight (TOF) applications are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High time resolution observations of corotating interaction region proton events by Pioneer 11

Pioneer 11 high-time resolution, 1-min observations of energetic (about 1 MeV) proton events associated with the corotating interaction regions (CIR) are presented, together with pitch angle distributions and crude differential spectra in the energy range 0.6-3.4 MeV. The principal finding of the study is evidence for the persistent flow of protons with energies about 1 MeV away from CIR shocks. This evidence comes from the analysis of pitch angle distributions. The observations are found to be in good agreement with the hypothesis of local interplanetary shock acceleration.

Pesses, M. E.↗

A search for fast radio bursts at low frequencies with Murchison Widefield Array high time resolution imaging

We present the results of a pilot study search for fast radio bursts (FRBs) using the Murchison Widefield Array (MWA) at low frequencies (139–170 MHz). We utilized MWA data obtained in a routine imaging mode from observations where the primary target was a field being studied for Epoch of Reionization detection. We formed images with 2 s time resolution and 1.28 MHz frequency resolution for 10.5 hr of observations, over 400 square degrees of the sky. We de-dispersed the dynamic spectrum in each of 372,100 resolution elements of 2 × 2 arcmin{sup 2}, between dispersion measures of 170 and 675 pc cm{sup −3}. Based on the event rate calculations in Trott et al., which assume a standard candle luminosity of 8 × 10{sup 37} Js{sup −1}, we predict that with this choice of observational parameters, the MWA should detect (∼10, ∼2, ∼0) FRBs with spectral indices corresponding to (−2, −1, 0), based on a 7σ detection threshold. We find no FRB candidates above this threshold from our search, placing an event rate limit of <700 above 700 Jy ms per day per sky and providing evidence against spectral indices α<−1.2 (S∝ν{sup α}). We compare our event rate and spectral index limits with others from the literature. We briefly discuss these limits in light of recent suggestions that supergiant pulses from young neutron stars could explain FRBs. We find that such supergiant pulses would have to have much flatter spectra between 150 and 1400 MHz than have been observed from Crab giant pulses to be consistent with the FRB spectral index limit we derive.

79 ASTRONOMY AND ASTROPHYSICS↗

Temporal correlations between impulsive ultraviolet and hard X-ray bursts in solar flares observed with high time resolution

The impulsive phase of solar flares has been simultaneously observed in the ultraviolet O V line, the UV continuum, and hard X-rays with a time resolution of 0.128 s by the SMM satellite. A close time correspondence between the three impulsive components is found, with the best correlation being at the peak of the impulsive phase. Individual bursts or fast features in the O V and the UV continuum are shown to lag behind the corresponding hard X-ray features. None of the considered energy transport mechanisms (thermal conduction, a nonthermal electron beam, electron hole boring, UV radiation, and Alfven waves) are able to consistently account for the observed temporal correlations.

Cheng, Chung-Chieh↗

High time resolution spectrophotometry of nova DQ Herculis /1934/

Thirty-four spectra of DQ Her are analyzed which were obtained with a time resolution greater than 0.01 cycle. It is found that: (1) the 18th mag visual companion of DQ Her has an energy distribution similar to that of a late F star and is not likely to be a member of the system; (2) the time of minimum has no wavelength dependence and agrees better with the elements of Patterson et al. (1978) than with a linear ephemeris; (3) only very weak evidence exists for the detection of a late-type star, which is of spectral type M4 or later, even at mideclipse; (4) the spectrum of the residual light at mideclipse can be represented by optically thin free-free plus bound-free emission at a temperature of 35,000 K, an electron density of (1-10) trillion per cu cm, and a star contributing about 90% of the red flux; and (5) there is a definite asymmetry in the light curve, as well as strong evidence for a localized bright spot on the side of the disk eclipsed last.

Schneider, D. P.↗

Discovering Hidden Material Properties of MgCl 2 at Atomic Resolution with Structured Temporal Electron Illumination of Picosecond Time Resolution

Abstract A combination of atomic resolution phase contrast electron microscopy and pulsed electron beams reveals pristine properties of MgCl 2 at 1.7 Å resolution that were previously masked by air and beam damage. Both the inter‐ and intra‐layer bonding in pristine MgCl 2 are weak, which leads to uncommonly large local orientation variations that characterize this Ziegler–Natta catalyst support. By delivering electrons with 1–10 ps pulses and ≈160 ps delay times, phonons induced by the electron irradiation in the material are allowed to dissipate before the subsequent delivery of the next electron packet, thus mitigating phonon accumulations. As a result, the total electron dose can be extended by a factor of 80–100 to study genuine material properties at atomic resolution without causing object alterations, which is more effective than reducing the sample temperature. In conditions of minimal damage, beam currents approach femtoamperes with dose rates around 1 eÅ −2 s −1 . Generally, the utilization of pulsed electron beams is introduced herein to access genuine material properties while minimizing beam damage.

Kisielowski, Christian↗

High resolution time interval counter

In recent years, we have developed two types of high resolution, multi-channel time interval counters. In the NIST two-way time transfer MODEM application, the counter is designed for operating primarily in the interrupt-driven mode, with 3 start channels and 3 stop channels. The intended start and stop signals are 1 PPS, although other frequencies can also be applied to start and stop the count. The time interval counters used in the NIST Frequency Measurement and Analysis System are implemented with 7 start channels and 7 stop channels. Four of the 7 start channels are devoted to the frequencies of 1 MHz, 5 MHz or 10 MHz, while triggering signals to all other start and stop channels can range from 1 PPS to 100 kHz. Time interval interpolation plays a key role in achieving the high resolution time interval measurements for both counters. With a 10 MHz time base, both counters demonstrate a single-shot resolution of better than 40 ps, and a stability of better than 5 x 10(exp -12) (sigma(sub chi)(tau)) after self test of 1000 seconds). The maximum rate of time interval measurements (with no dead time) is 1.0 kHz for the counter used in the MODEM application and is 2.0 kHz for the counter used in the Frequency Measurement and Analysis System. The counters are implemented as plug-in units for an AT-compatible personal computer. This configuration provides an efficient way of using a computer not only to control and operate the counters, but also to store and process measured data.

Zhang, Victor S.↗

Shape and Rotational Motion Models for Tumbling and Monolithic Asteroid 2012 TC{sub 4}: High Time Resolution Light Curve with the Tomo-e Gozen Camera

We present visible and near-infrared observations of a near-Earth object (NEO), 2012 TC{sub 4}. The NEO 2012 TC{sub 4} approached close to Earth at a distance of about 50,000 km in 2017 October. This close approach provided a practical exercise for planetary defense. This apparition was also an appropriate opportunity to investigate 2012 TC{sub 4}, which is a monolithic asteroid. We conducted the observation campaign of 2012 TC{sub 4} using six small- and medium-sized telescopes. The multiband photometry analysis showed the taxonomic class of 2012 TC{sub 4} to be an X type. In particular, we successfully obtained the high time resolution light curve of 2012 TC{sub 4} with the Tomo-e Gozen camera, which is the world’s first wide-field CMOS camera, mounted on the 1.05 m Schmidt telescope at Kiso Observatory. The shape and rotational motion models of 2012 TC{sub 4} were derived from the light curve. When 2012 TC{sub 4} was assumed to be a triaxial ellipsoid, the rotational and precession periods were 8.47 ± 0.01 minutes and 12.25 ± 0.01 minutes, respectively, with the long-axis mode. This indicates that 2012 TC{sub 4} is a tumbling and monolithic asteroid. The shape models showed the plausible axial lengths to be 6.2 × 8.0 × 14.9 m or 3.3 × 8.0 × 14.3 m. The flattened and elongated shape indicates that 2012 TC{sub 4} is a fragment produced by an impact event. We also estimated the excitation timescale, which implied that the impact event happened within ∼3 × 10{sup 5} yr and 2012 TC{sub 4} has a fresh surface.

79 ASTRONOMY AND ASTROPHYSICS↗

High-time resolution of the low-latitude asymmetric disturbance in the geomagnetic field.

The low-latitude asymmetric disturbance field is investigated by means of a Fourier harmonic analysis performed on 2.5-min interspaced values of magnetic records from eight stations, in lieu of the hourly values used in Crooker and Siscoe's (1971) study. The major advantage of the higher time resolution is that substorm activity, which has a time scale of 1-2 hr, can be studied in detail. Data covering four active periods in 1965 and five active periods in 1967 are used.

Crooker, N. U.↗

Particle acceleration due to shocks in the interplanetary field: High time resolution data and simulation results

Data were examined from two experiments aboard the Explorer 50 (IMP 8) spacecraft. The Johns Hopkins University/Applied Lab Charged Particle Measurement Experiment (CPME) provides 10.12 second resolution ion and electron count rates as well as 5.5 minute or longer averages of the same, with data sampled in the ecliptic plane. The high time resolution of the data allows for an explicit, point by point, merging of the magnetic field and particle data and thus a close examination of the pre- and post-shock conditions and particle fluxes associated with large angle oblique shocks in the interplanetary field. A computer simulation has been developed wherein sample particle trajectories, taken from observed fluxes, are allowed to interact with a planar shock either forward or backward in time. One event, the 1974 Day 312 shock, is examined in detail.

Kessel, R. L.↗

High time resolution studies of binary x ray pulsars

This report covers the period September 1, 1992 through August 1, 1993 for NASA grant NAG 5-1260 through the Astrophysics Data Program (ADP), for the project 'High Time Resolution Studies of Binary X-ray Pulsars'. During the past 11 months, we have concentrated on scientific analysis of the data, and have had to reanalyze several data sets, due to a newly discovered error in the unpacking of the count rate data. This error has now been corrected, but may have caused us to miss some scientific results, so we have gone back and reanalyzed the affected data sets, as well as continuing our analysis of other objects.

Cominsky, Lynn R.↗

High Time Resolution Study of the Hemispheric Power Carried by Energetic Electrons Into the Ionosphere During the May 19-20, 1996, Auroral Activity

The UVI imager on board the POLAR satellite offers the opportunity to obtain high time resolution global auroral images. The spectral resolution of the imager is sufficient to separate the auroral emission from the scattered sunlight, even when the entire auroral zone is sunlit. The energy flux of the precipitating electrons is derived from the surface brightness through the LBH-long filter. Global images which have the dayglow removed are spatially integrated to yield the total hemispheric electron energy flux. This parameter, the hemispheric power, has found much application in ionospheric modeling. It can also be derived from electron spectra measured along the track of the NOAA/TIROS satellites that are combined with average empirical auroral precipitation patterns. We show that the hemispheric power input derived from the two-dimensional images represents a substantial improvement in the temporal variability of this parameter. We present an example for the period of 19/20 May 1996 by comparing power indices derived from NOAA/TIROS measurements with those derived from the UVI images.

Lummerzheim, D.↗

Gamma-ray burst high time-resolution spectral observations made with the Solar Maximum Mission

The gamma-ray bursts of April 19 and 21, 1980, and March 1, 1981, are characterized on the basis of observations obtained at 25-500 keV and time resolution 128 msec using the hard-X-ray-burst spectrometer of the SMM satellite. The data are presented graphically, and the parameters determined by fitting three theoretical models to the data for each phase (rising phase, decay phase, and valleys between pulses) are given in tables. Models used are thin thermal bremsstrahlung with or without absorption lines, thermal synchrotron with or without absorption lines, and power law with exponential cutoff.

Desai, U. D.↗

IDE spatio-temporal impact fluxes and high time-resolution studies of multi-impact events and long-lived debris clouds

During the first 12 months of the Long Duration Exposure Facility (LDEF) mission, the Interplanetary Dust Experiment (IDE) recorded over 15,000 total impacts on six orthogonal faces with a time resolution on the order of 15 to 20 seconds. When combined with the orbital data and the stabilized configuration of the spacecraft, this permits a detailed analysis of the micro-particulate environment. The functional status of each of the 459 detectors was monitored every 2.4 hours, and post-flight analyses of these data has now permitted an evaluation of the effective active detection area as a function of time, panel by panel and separately for the two sensitivity levels. Thus, total impacts were transformed into areal fluxes, and are presented here for the first time. Also discussed are possible effects of these fluxes on previously announced results: apparent debris events, meteor stream detections, and beta meteoroids in observationally significant numbers.

Mulholland, J. Derral↗

High time resolution measurements of rocket potential changes induced by electron beam emission

The transient charging and photon emission from the vacuum chamber testing of the Cooperative High Altitude Rocket Gun Experiment are studied. Graphs of the mother-daughter voltage versus time and high time resolution data related to the return current to the vehicle are examined. It is observed that for average sounding rocket densities of 10 to the -6th torr the slope of the voltage rise of the rocket begins to flatten 40 microsec after the onset of electron beam emission, and for higher gas pressure the rocket reaches a maximum voltage of 25 or 30 microsec after the onset of electron beam emission. The data reveal that the return current mechanism for the higher gas pressure is through the sheath.

Raitt, W. J.↗