Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “THERMAL BATTERY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

200 h of discharge cycling with an all-aqueous copper thermally regenerative ammonia battery

Thermally regenerative ammonia batteries (TRABs) offer an approach to energy storage and electricity generation by harnessing low-grade heat (T < 150 °C). A TRAB discharge resembles that of a flow battery, where electrochemical reactions produce electrical power from energy stored within aqueous electrolytes. While there are many types of TRABs, the all-aqueous copper TRAB (Cu aq -TRAB) has produced the largest power and energy storage densities. Despite many improvements to TRAB performance, most tests have only lasted a few hours, which are not representative of operation times expected of these devices. Herein, we operated a Cu aq -TRAB for 200 h of constant current discharging to assess battery performance and component stability. After 200 h of testing, the average power density increased slightly to 7.2 mW cm -2 , which was within 0.01 % of starting conditions. Likewise, the average energy density for the final cycle was only 0.03 % lower than the initial cycle. The overall insensitivity of the power cell to cycling represents a major milestone in the advancement of TRAB systems. In conclusion, energy dispersive X-ray spectroscopy provides evidence to suggest that these small changes in power and energy density are likely to the membrane acclimating to TRAB electrolytes.

25 ENERGY STORAGE↗

Multi-fidelity electrochemical modeling of thermally activated battery cells

Thermally activated batteries undergo a series of coupled physical changes during activation that influence battery performance. These processes include energetic material burning, heat transfer, electrolyte phase change, capillary-driven two-phase porous flow, ion transport, electrochemical reactions, and electrical transport. Several of these processes are strongly coupled and have a significant effect on battery performance, but others have minimal impact or may be suitably represented by reduced-order models. Additionally, assessing the relative importance of these phenomena must be based on comparisons to a high-fidelity model including all known processes. In this work, we first present and demonstrate a high-fidelity, multi-physics model of electrochemical performance. This novel multi-physics model enables predictions of how competing physical processes affect battery performance and provides unique insights into the difficult-to-measure processes that happen during battery activation. We introduce four categories of model fidelity that include different physical simplifications, assumptions, and reduced-order models to decouple or remove costly elements of the simulation. Using this approach, we show an order-of-magnitude reduction in computational cost while preserving all design-relevant quantities of interest within 5 percent. The validity of this approach and these model reductions is demonstrated by comparison between results from the full fidelity model and the different reduced models.

25 ENERGY STORAGE↗

Thermal regulation of batteries

A battery thermal management system for an air vehicle includes a liquid heat exchange circuit. The system includes at least one battery in thermal communication with the liquid heat exchange circuit. The system includes a controller operatively connected to the liquid heat exchange circuit. The controller is configured and adapted to variably select whether heat will be rejected to the liquid heat exchange circuit. The system includes at least one heat exchanger positioned on the liquid heat exchange circuit. The at least one heat exchanger is a liquid-air heat exchanger or a liquid-liquid heat exchanger. A method for controlling a thermal management system for an air vehicle includes determining an expected temperature of at least one battery, and cooling the at least one battery with a cooling device if the expected temperature exceeds a pre-determined expected temperature threshold.

Rheaume, Jonathan↗

Thermal regulation of batteries

A battery thermal management system for an air vehicle includes a first heat exchange circuit, a battery in thermal communication with the first heat exchange circuit, and a heat exchanger positioned on the first heat exchange circuit. The heat exchanger is operatively connected to a second heat exchange circuit. The system includes a controller operatively connected to the second heat exchange circuit. The controller is configured to variably select whether heat will be rejected to the second heat exchange circuit. A method for controlling a thermal management system for an air vehicle includes determining an expected fluid temperature of fluid in a fluid heat exchange circuit. The method includes commanding a flow restrictor at least partially closed or commanding the flow restrictor at least partially open.

Macdonald, Malcolm↗

Mechanically induced thermal runaway severity analysis for Li-ion batteries

Thermal runaway is one of the most important safety concerns in the deployment of Li-ion batteries. For this study, we developed a standardized single-side indentation test protocol to induce an internal short-circuit. Cell voltage, temperature, and applied compressive force are monitored as a function of time. Each cell is given an observed hazard severity (OHS in five categories) modified from the EUCAR table. Meanwhile a calculated hazard severity (CHS) is obtained solely based on temperature and voltage curves. The calculation formula considers the cell temperature, rate of temperature increase, cell capacity, state of charge (SOC), voltage drop, and voltage drop rate. Each term is assigned with an appropriate weight to scale the calculated score from 0 to100. This method was applied to >100 Li-ion batteries with various SOCs and chemistries, and their OHS and CHS were displayed against SOC. The purpose is to provide battery designers, manufacturers, and end-users a clear comparison of thermal runaway severity of different batteries.

25 ENERGY STORAGE↗

Improved internal short circuit models for thermal runaway simulations in lithium-ion batteries

Thermal runaway (TR) modeling is one of the primary tools that can be used to overcome challenges associated with lithium-ion battery (LIB) safety. Among all LIB accidents that have occurred over the past decade, Internal Short Circuit (ISC) remains the most common trigger mechanism. Many available models in the literature either use a simplified approach to simulate ISC or completely ignore its contribution. The aim of this study is to understand the nature of the heat released for different types of ISC scenarios, including aluminum-anode, anode–cathode, and copper-cathode ISC. We study ISC behavior using a coupled electrochemical–thermal model with an integrated TR chemical kinetics solver built in the COMSOL Multiphysics framework. The time duration of heat release and the magnitude of the peak ISC current are studied as functions of parameters such as the size of the penetrating filament and the capacity of the cell. The numerical results are used to build an empirical model validated against the published experimental TR propagation data. Our model can be successfully used as a viable low-cost substitute in lower order (lumped) TR simulations to enable TR prevention and mitigation.

Singh, Bakhshish Preet (ORCID:0000000264751992)↗

Thermal Analysis on Large Format Lithium-Ion Batteries in Thermal Runaway

Lithium-ion (Li-ion) batteries can deliver electrical power across a large range of applications, and large format versions of these batteries are common in aerospace for their low mass and energy dense properties. Li-ion cells usage has increased as they are more power dense than fuel cells and have overall higher performance over lead-acid/NiCd batteries. However, Li-ion cells can experience Thermal Runaway (TR) via electro-chemical, mechanical, or thermal abuse. TR is a phenomenon where the stored energy in a cell is rapidly released along with vented gases and other effluents. A cell is generally determined to be in TR if its internal heat generation has surpassed its ability to dissipate that heat. If a Li-ion cell enters TR, propagation within the battery may occur. Propagation is the chain reaction that can occur to nearby cells due to a cell that has entered TR initially. Understanding a battery’s susceptiveness to propagation is necessary to evaluate risks associated with TR phenomenon. To determine if a battery is designed in a sufficient manner to prevent battery propagation if single cell TR occurs, testing and thermal analysis of the battery must be conducted. The presentation for TFAWS 2026 will cover considerations for battery TR thermal analysis, such as: testing methods, influences on the cells, failure mechanisms, and TR parameters. This presentation will include a walkthrough of an example battery TR thermal analysis, and the results thereof.

Lithium Ion Batteries↗

Insights Into Thermal Runaway Mechanisms: Fast Tomography Analysis of Metal Agglomerates in Lithium-Ion Batteries

Thermal Runaway (TR) in lithium-ion batteries (LIB) is a critical technological and social concern. Whilst such events are rare, TR is characterized by uncontrollable heating leading to catastrophic failures. To deepen the understanding of the failure process and subsequently develop more accurate TR prediction models and as a result safer battery systems, we present in this work high-speed X-ray tomography for in-depth investigations of the copper current collector melting and agglomeration during TR. The melting process presents valuable real-time internal information about heat evolution during TR, previously challenging to access but crucially important for validating TR models. In this work, controlled failure studies combined with high-speed X-ray tomography were performed on two different commercial LIB models, subjecting them to both external heating and nail penetration to induce TR. Through real-time observation via high-speed tomography, followed by segmentation, rendering, and analysis, the formation of copper agglomerates was qualitatively and quantitatively characterized and visualized for the first time. Agglomerates tended to form either from the battery's outermost layers or centrally, depending on the method of TR initiation, and gives an indirect insight into the internal temperature evolution and distribution. Moreover, an initial comparative analysis between the battery models also revealed differences in agglomerate size, which has been linked to the thicker copper current collectors of one of the cell models. We further discuss the impact of larger copper agglomerates on heat distribution and safety. This study not only sheds light on the intricate dynamics of TR in LIBs but also underscores the pivotal role of 'gold-standard' imaging techniques in advancing battery safety, crucial for the robust modeling of TR and the future design of electric vehicle safety systems.

25 ENERGY STORAGE↗

A hierarchical framework for aggregating grid-interactive buildings with thermal and battery energy storage

The behind-the-meter (BTM) thermal and battery energy storage can help improve energy efficiency, reduce energy costs, and enhance energy resilience, particularly in rural areas and for disadvantaged communities. Aggregating numerous BTM energy storage systems can act as a price influencer with a significant source of load shifting and peak demand reduction. An integrated and scalable control mechanism is required to effectively utilize energy storage systems and flexible building loads to maximize the economic benefits, considering various distribution system constraints. Here, this paper presents an innovative hierarchical coordination framework for energy storage and flexible load in buildings, considering various factors such as electricity prices, thermal comfort, and distribution system modeling and constraints. At the upper level, a distribution system operator optimizes the power flow to minimize its power procurement costs from the electricity wholesale market, while at the lower level, aggregators determine the optimal dispatch of battery and thermal energy storage systems in multiple buildings on behalf of end-users to minimize operating costs according to the power prices. These problems are solved using a game-theoretic approach through negotiations between the distribution system operator and aggregators as a bi-level decision model. Simulation case studies have been performed for a test distribution network with a number of building end-users using energy storage systems to quantify the performance of aggregators. The results demonstrate that the proposed strategy can reduce peak load for a reliable electricity distribution network while saving electricity bills for customers.

25 ENERGY STORAGE↗

Multi-objective sizing and dispatch for building thermal and battery storage towards economic and environmental synergy

The role of building thermal and battery storage is pivotal in advancing smart cities and achieving sustainability goals through effective energy management. Despite their significance, there are several limitations in the sizing approach and value stream analysis with various objectives for their widespread adoption in buildings. This work proposes a flexible and scalable multi-objective optimization framework for optimal sizing and dispatch of building thermal and battery storage, addressing conflicting objectives simultaneously using mixed-integer linear programming. The weighted-sum method is adapted, combining multiple objectives into a single function. The two-stage procedure iterates over different weights, generating optimal solutions and forming the Pareto front. Case studies are performed to assess the energy, economic, and environmental benefits of building energy storage systems for a large office building in three climate locations. The results demonstrate that the proposed framework efficiently determines optimal sizing and dispatch strategies, addressing the balance between economic viability and emission reduction. The dynamic relationship between time-of-use energy charges and emission factors leads to significantly different strategies based on whether economic or environmental concerns are prioritized. This research enhances our understanding of the benefits of TES and BES systems in buildings, providing valuable guidance to stakeholders.

25 ENERGY STORAGE↗

Lithium ion battery with thermal runaway protection

Lithium ion batteries are provided that include materials that provide advantageous endothermic functionalities contributing to the safety and stability of the batteries. The endothermic materials may include a ceramic matrix incorporating an inorganic gas-generating endothermic material. If the temperature of the lithium ion battery rises above a predetermined level, the endothermic materials serve to provide one or more functions to prevent and/or minimize the potential for thermal runaway, e.g., thermal insulation (particularly at high temperatures); (ii) energy absorption; (iii) venting of gases produced, in whole or in part, from endothermic reaction(s) associated with the endothermic materials, (iv) raising total pressure within the battery structure; (v) removal of absorbed heat from the battery system via venting of gases produced during the endothermic reaction(s) associated with the endothermic materials, and/or (vi) dilution of toxic gases (if present) and their safe expulsion from the battery system.

25 ENERGY STORAGE↗

Hydrocarbon-based membranes cost-effectively manage species transport and increase performance in thermally regenerative batteries

Low-temperature heat (T<130°C) can be utilized by thermally regenerative batteries (TRBs) for power production, allowing the thermal energy to be converted to storable chemical potential energy. However, TRBs suffer from high ohmic losses and ammonia crossover, which has slowed their development. In this study, we examined how the use of six different membranes influenced TRB performance, determined the most influential membrane parameters, and identified promising membrane candidates that cost-effectively increase TRB performance. Of the six membranes examined, an inexpensive, hydrocarbon CEM (Selemion CMVN) had low ammonia crossover without compromising resistance, resulting in good performance across all metrics studied. A thin anion exchange membrane (Sustainion, 50 microns) showed a high peak power density of 82 mW cm –2 due to low resistance, but the average power density and energy density were low due to high ammonia flux. Full discharge curves using Selemion CMVN provided an average power density of 26 ± 7 mW cm –2 with an energy density of 2.9 Wh L –1 , which were large improvements on previous TRBs. A techno-economic analysis showed that Selemion CMVN had the lowest levelized cost of storage ($410 per MWh) at an applied current density of 50 mA cm –2 .

25 ENERGY STORAGE↗

Long Life Molten Salt Battery for NASA Venus Application

A development program is being conducted at Advanced Thermal Batteries (ATB) to create a low discharge rate, long life, molten salt battery for a NASA Venus surface probe. Battery goals are 60 days continuous operation at +25V +0/-6 volts and -25V +6/-0 Volts under severe environments of 465°C, 92 atm pressure, and corrosive sulfur dioxide in a super critical carbon dioxide atmosphere. Conveniently, molten salt thermal battery electrochemistry starts to operate efficiently at 330°C. However, a major barrier to direct application of existing thermal battery technology is the high self-discharge rate, resulting in lifetimes in only minutes, not days. The best performance to date, which meets the required voltage regulation, has been a lithium silicon (LiSi) alloy anode discharging through all three voltage plateau versus an iron monosulfide (FeS) cathode. In order to perform reproducibly, additional engineering controls within the battery design are required to limit cell–to–cell parasitic discharge mechanisms. Results of these trials have improved the efficiency and manufacturability of the design.

Thermal Battery↗

Synergies Between Building-Sited Batteries and Thermal Energy Storage

As renewable penetration increases, there is a greater need for energy storage systems located at buildings. This storage can include batteries, which directly shift the metered load, or thermal energy storage, which shifts thermal-driven electric loads like air conditioning. This presentation covers modeling results of the potential demand reduction and annualized cost savings for different combinations of thermal and battery energy storage sizes. It also shows how battery storage can expand the usefulness of thermal energy storage for electric load shaving, and how thermal storage can lower the cost of the overall storage system and extend battery lifetime by reducing cycling.

batteries↗

An analytical method for identifying synergies between behind-the-meter battery and thermal energy storage

Electric utilities build generation capacity to meet the highest demand period, and they often pass on the costs associated with these peaking generators to building owners through demand charges. Building owners can minimize these demand charges by shifting energy use away from peak periods with behind-the-meter storage. This storage can include batteries, which can directly shift the metered load, or thermal energy storage, which can shift thermal-driven electric loads like air conditioning. However, there is a lack of research on how best to combine battery and thermal energy storage. In this study, we develop an analytical sizing method to calculate the potential demand reduction and annualized cost savings for different combinations of thermal and battery energy storage sizes. We show that adding batteries to a thermal energy storage system can increase the total system's load shaving potential. This is particularly true when the building has onsite photovoltaic generation or electric vehicle charging, which add significant variability to the load shape. We also show that for a given total storage size, selecting a higher fraction of thermal energy storage can significantly lower the cycling of the battery, and therefore extend the battery life. This, combined with the expected lower first cost of thermal energy storage materials compared to batteries, shows that hybrid energy storage systems can outperform a standalone battery or standalone thermal storage system. Assuming the thermal storage has a capital cost 6x lower than the battery, our analysis shows that the optimal system is 71% thermal energy storage and 29% battery energy storage for a scenario with electric vehicle charging. The annualized cost savings for this system are $48.6 k/yr, whereas an equivalently sized standalone thermal energy storage system would provide annualized cost savings of $28.5 k/yr and a standalone battery would lead to savings of $8.72 k/yr. The hybrid system also reduces battery cycling by 52% compared to a standalone battery, extending battery lifetime.

25 ENERGY STORAGE↗

CHARACTERIZATION AND DEVELOPMENT OF THE ALL–AQUEOUS COPPER THERMALLY REGENERATIVE AMMONIA BATTERY

Low temperature thermal energy is an abundant and untapped energy source for large scale electrical power and energy production around the world. Many different stationary sources such as industrial and thermal power plants produce significant amounts of low temperature heat that goes unused. The primary reason for the energy loss is because the temperature of the heat is often too low for traditional systems to economically generate power from this waste heat. Many different technologies are being researched to produce grid–scale power from low temperature heat to increase grid efficiency, advance decarbonization efforts, and progress electrical power production to a more distributed system. A thermally regenerative battery (TRB) is one promising technology in this space, as it has large power and energy densities relative to competitive technologies and therefore has the potential to disrupt the current power generation mix. TRBs combine two unit operations (a redox flow battery and a distillation column) which are easily scalable and mature, meaning that if a viable TRB chemistry can be identified, its development to pilot and commercial scale can be streamlined. The all–aqueous, copper thermally regenerative ammonia battery (Cuaq–TRAB) was the first TRB that did not use an electrodeposition/dissolution reaction by stabilizing Cu(I) and Cu(II) in the electrolyte, allowing all electroactive species to be stable in an aqueous phase. Through these electrolyte modifications, coulombic efficiency, open circuit potential, and copper solubility all increased, resulting in large gains to power density, energy density, and energy efficiency.

Cross, Nicholas↗