Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TESLA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Observations of Long-Range and Short-Range Wakefield Effects on Electron-Beam Dynamics in TESLA-type SCRF Cavities

The Fermilab Accelerator Science and Technology (FAST) facility has a unique configuration of a photocathode rf gun beam injecting two TESLA-type single cavities (CC1 and CC2) in series prior to the cryomodule. Beam propagation off axis in these cavities can result in both long-range and short-range transverse wakefields which can lead to emittance dilution within the macropulses and micropulses, respectively. Two configurations of a Hamamatsu C5680 streak camera viewing a downstream OTR screen were utilized to track centroid shifts during the macropulse (framing mode) for the long-range case and during the micropulse for the short-range case (~10-micron spatial resolution and 2-ps temporal resolution). Steering off axis before CC1, resulted in a 100-kHz bunch centroid oscillation within the macropulse that was detected by the downstream rf BPMs and the streak camera*. At 500 pC/b, 50b, and 4-mrad off-axis vertical steering into CC2, we observed an ~ 100-micron head -tail centroid shift in the streak camera image y(t) profiles which we attributed to a short-range wakefield effect. Additional results for kick-angle compensations and model results will be presented.

43 PARTICLE ACCELERATORS↗

Considerations on wakefield effects in a VUV FELO driven by a superconducting tesla-type linac

The effects on beam dynamics from long-range and short-range wakefields from TESLA-type cavities are considered in regard to a proposed FEL oscillator (FE-LO) operating at 120 nm. This would be driven by the Fermilab Accelerator Science and Technology (FAST) linac at 300 MeV with a 3-MHz micropulse repetition rate. Our wakefield studies showed measurable effects on submacropulse centroid stability and on submicropulse head-tail kicks that can lead to emittance degradation. In the case of the former, we use MINERVA/OPC to simulate the ~100-$\mu$m centroid slew effects on the saturated output power levels of the FELO.

43 PARTICLE ACCELERATORS↗

Vacuum insulated room temperature bore horizontal cryostat for 4-Tesla superconducting magnet

4-Tesla warm bore superconducting magnet is being constructed at Bhabha Atomic Research Centre in India. The adiabatically cooled superconducting magnet will be used for corrosion and Magneto Hydro Dynamic (MHD) studies related to development of Lead Lithium Cooled Ceramic Breeder (LLCB) test blanket module (TBM). Magnet aperture is of 300 mm diameter and is accessible from both ends. Magnet is completely immersed in liquid helium bath at 4.2K. The stored magnetic energy during normal operation is 2.6 MJ. Huge amount of Lorentz forces acts on the magnet coils during operation. These forces try to axially compress the coils and cause outward radial movement of the conductor. Micro meter movement of the coils result in energy deposition due to large operating fields. This energy, albeit small, is still sufficient to cause quench in the magnet as the heat capacities at cryogenic temperatures are very low. Pre-stressing and banding of the superconducting strands help to overcome conductor movement by increasing structural rigidity. This paper describes the thermal, structural and magnetic design the superconducting solenoid magnet. (author)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Emerging Role of 7 Tesla MRI in Musculoskeletal Imaging

Purpose of Review: To describe the emergent role of ultra-high field (UHF) MR with respect to musculoskeletal MRI applications. Recent Findings: With the recent US Federal Drug Administration (FDA) and European Union (EU) approval of ultra-high field (UHF) MRI below 8T for clinical use, and the availability of clinical 7T MRI systems, there is a rising interest in the potential clinical and research applications in musculoskeletal MRI. Summary: With increases in field strength and SNR gains resulting in sharper and higher spatial resolution MRI images, there is increasing interest in UHF MRI. Although there are challenges and limitations in UHF, there are many new and unique musculoskeletal MR applications that UHF excels at such as morphological imaging, bone micro-architecture evaluation, biochemical imaging techniques such gagCEST, UTE/ZTE, T{sub 2} mapping, T{sub 2}* mapping, T1ρ mapping, and multi-nuclear imaging and spectroscopy/imaging techniques with {sup 23}Na and {sup 31}P. The goal of this review is to highlight some of these recent findings in musculoskeletal MRI applications at UHF.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Early Choline Levels From 3-Tesla MR Spectroscopy After Exclusive Radiation Therapy in Patients With Clinically Localized Prostate Cancer are Predictive of Plasmatic Levels of PSA at 1 Year

Purpose: To investigate the time course response of prostate metabolism to irradiation using magnetic resonance spectroscopy (MRS) at 3-month intervals and its impact on biochemical control. Methods and Materials: Between January 2008 and April 2010, 24 patients with localized prostate cancer were prospectively enrolled in the Evaluation of the Response to Irradiation with MR Spectroscopy (ERIS) trial. All the patients had been treated with intensity-modulated radiation therapy with or without long-term adjuvant hormonal therapy (LTHT) and underwent 3-T MRS and prostate-specific antigen (PSA) assays at baseline and every 3 months thereafter up to 12 months. Results: After radiation, the mean normalized citrate level (citrate/water) decreased significantly over time, both in the peripheral zone (PZ) (p = 0.0034) and in the entire prostate (p = 0.0008), whereas no significant change was observed in mean normalized choline levels (choline/water) in the PZ (p = 0.84) and in the entire prostate (p = 0.95). At 6 months after radiation, the mean choline level was significantly lower in the PZ for patients with a PSA value of {<=}0.5 ng/mL at 12 months (4.9 {+-} 1.7 vs. 7.1 {+-} 1.5, p = 0.0378). Similar results were observed at 12 months in the PZ (6.2 {+-} 2.3 vs. 11.4 {+-} 4.1, p = 0.0117 for choline level and 3.4 {+-} 0.7 vs. 16.1 {+-} 6.1, p = 0.0054 for citrate level) and also in the entire prostate (6.2 {+-} 1.9 vs. 10.4 {+-} 3.2, p = 0.014 for choline level and 3.0 {+-} 0.8 vs. 13.3 {+-} 4.7, p = 0.0054 for citrate level). For patients receiving LTHT, there was no correlation between choline or citrate levels and PSA value, either at baseline or at follow-up. Conclusions: Low normalized choline in the PZ, 6 months after radiation, predicts which patients attained a PSA {<=}0.5 ng/mL at 1 year. Further analyses with longer follow-up times are warranted to determine whether or not these new biomarkers can conclusively predict the early radiation response and the clinical outcome for patients with or without LTHT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

3-Dimensional Magnetic Resonance Spectroscopic Imaging at 3 Tesla for Early Response Assessment of Glioblastoma Patients During External Beam Radiation Therapy

Purpose: To evaluate the utility of 3-dimensional magnetic resonance (3D-MR) proton spectroscopic imaging for treatment planning and its implications for early response assessment in glioblastoma multiforme. Methods and Materials: Eighteen patients with newly diagnosed, histologically confirmed glioblastoma had 3D-MR proton spectroscopic imaging (MRSI) along with T2 and T1 gadolinium-enhanced MR images at simulation and at boost treatment planning after 17 to 20 fractions of radiation therapy. All patients received standard radiation therapy (RT) with concurrent temozolomide followed by adjuvant temozolomide. Imaging for response assessment consisted of MR scans every 2 months. Progression-free survival was defined by the criteria of MacDonald et al. MRSI images obtained at initial simulation were analyzed for choline/N-acetylaspartate ratios (Cho/NAA) on a voxel-by-voxel basis with abnormal activity defined as Cho/NAA ≥2. These images were compared on anatomically matched MRSI data collected after 3 weeks of RT. Changes in Cho/NAA between pretherapy and third-week RT scans were tested using Wilcoxon matched-pairs signed rank tests and correlated with progression-free survival, radiation dose and location of recurrence using Cox proportional hazards regression. Results: After a median follow-up time of 8.6 months, 50% of patients had experienced progression based on imaging. Patients with a decreased or stable mean or median Cho/NAA values had less risk of progression (P<.01). Patients with an increase in mean or median Cho/NAA values at the third-week RT scan had a significantly greater chance of early progression (P<.01). An increased Cho/NAA at the third-week MRSI scan carried a hazard ratio of 2.72 (95% confidence interval, 1.10-6.71; P=.03). Most patients received the prescription dose of RT to the Cho/NAA ≥2 volume, where recurrence most often occurred. Conclusion: Change in mean and median Cho/NAA detected at 3 weeks was a significant predictor of early progression. The potential impact for risk-adaptive therapy based on early spectroscopic findings is suggested.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image Distortions on a Plastic Interstitial Computed Tomography/Magnetic Resonance Brachytherapy Applicator at 3 Tesla Magnetic Resonance Imaging and Their Dosimetric Impact

Purpose: To quantify magnetic resonance imaging (MRI) distortions on a plastic intracavitary/interstitial applicator with plastic needles at a field strength of 3 T and to determine the dosimetric impact, using patient data. Methods and Materials: For 11 cervical cancer patients, our clinical MRI protocol was extended with 3 scans. From the first scan, a multi-echo acquisition, a map of the magnetic field (B{sub 0}) was calculated and used to quantify the field inhomogeneity. The expected displacements of the applicator were quantified for the clinical sequence using the measured field inhomogeneity and the clinical sequence's bandwidth. The second and third scan were our routine clinical sequence (duration: <5 minutes each), acquired consecutively using opposing readout directions. The displacement of the applicator between these scans is approximately twice the displacement due to B{sub 0} inhomogeneity. The impact of the displacement on the dose was determined by reconstructing the applicator on both scans. The applicator was then shifted and rotated the same distance as the observed displacement to create a worst-case scenario (ie, twice the actual displacement due to B{sub 0} inhomogeneity). Next, the dose to 98%/90% (D{sub 98}/D{sub 90}) of the clinical target volume at high risk, as well as the dose to the most irradiated 2 cm{sup 3} for bladder and rectum, were calculated for the original plan as well as the shifted plan. Results: For a volume of interest containing the intrauterine device and the ovoids the 95th percentile of the absolute displacement ranged between 0.2 and 0.75 mm, over all patients. For all patients, the difference in D{sub 98}/D{sub 90} in the opposing readout scans with the original plan was at most 4.7%/4.3%. For the dose to the most irradiated 2 cm{sup 3} of bladder/rectum, the difference was at most 6.0%/6.3%. Conclusions: The dosimetric impact of distortions on this plastic applicator with plastic needles is limited. Applicator reconstruction for brachytherapy planning purposes is feasible at 3 T MRI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Terahertz EPR spectroscopy using a 36-tesla high-homogeneity series-connected hybrid magnet

Electron Paramagnetic Resonance (EPR) is a powerful technique to study materials and biological samples on an atomic scale. High-field EPR in particular enables extracting very small g-anisotropies in organic radicals and half-filled 3d and 4f metal ions such as Mn II (3d 5 ) or Gd III (4f 7 ), and resolving EPR signals from unpaired spins with very close g-values, both of which provide high-resolution details of the local atomic environment. Before the recent commissioning of the high-homogeneity Series Connected Hybrid magnet (SCH, superconducting + resistive) at the National High Magnetic Field Laboratory (NHMFL), the highest-field, high-resolution EPR spectrometer available was limited to 25 T using a purely resistive “Keck” magnet at the NHMFL. Herein, we report the first EPR experiments performed using the SCH magnet capable of reaching the field of 36 T, corresponding to an EPR frequency of 1 THz for g = 2. The magnet’s intrinsic homogeneity (25 ppm, that is 0.9 mT at 36 T over 1 cm diameter, 1 cm length cylinder) was previously established by NMR. We characterized the magnet’s temporal stability (5 ppm, which is 0.2 mT at 36 T over one-minute, the typical acquisition time) using 2,2-diphenyl-1-picrylhydrazyl (DPPH). This high resolution enables resolving the weak g-anisotropy of 1,3-bis(diphenylene)-2-phenylallyl (BDPA), Δg = 2.5 × 10 –4 obtained from measurements at 932 GHz and 33 T. Subsequently, we recorded EPR spectra at multiple frequencies for two Gd III complexes with potential applications as spin labels. In conclusion, we demonstrated a significant reduction in line broadening in Gd[DTPA], attributed to second order zero field splitting, and a resolution enhancement of g-tensor anisotropy for Gd[sTPATCN]-SL.

47 OTHER INSTRUMENTATION↗

High Speed Intact Protein Characterization Using 4X Frequency Multiplication, Ion Trap Harmonization, and 21 Tesla FTICR-MS

Mass spectrometric characterization of large biomolecules, such as intact proteins, requires the specificity afforded by ultra-high resolution mass measurements performed at both the intact mass and product ion levels. Although the performance of time-of-flight mass analyzers is steadily increasing, the choice of mass analyzer for large biomolecules (e.g. proteins >50 kDa) is generally limited to the Fourier transform family of mass analyzers, such as Orbitrap and ion cyclotron resonance (FTICR-MS) with the latter providing unmatched mass resolving power and measurement accuracy. Yet, protein analyses using FTMS are largely hindered by the low acquisition rates of ultra-high resolution spectra. Frequency multiple detection schemes enable FTICR-MS to overcome this fundamental barrier and achieve resolving powers and acquisition speeds 4X greater than the limits imposed by magnetic field strength. Here we expand upon earlier work on the implementation of this technique for biomolecular characterization. We report the coupling of 21T FTICR-MS, 4X frequency multiplication, ion trapping field harmonization technology, and spectral data processing methods to achieve unprecedented acquisition rates and resolving power in mass spectrometry of large intact proteins. Isotopically resolved spectra of multiply charged ubiquitin ions were acquired using detection periods as short as 12 ms. Large proteins such as apo-transferrin (MW=78 kDa) and monoclonal antibody (MW=150 kDa) were isotopically resolved with detection periods of 384 ms and 768 ms, respectively. These results illustrate the future capability of accurate characterization of large proteins on time-scales compatible with online separations.

Shaw, Jared B.↗

Sub-tesla On-Chip Nanomagnetic Metamaterial Platform for Angle-Resolved Photoemission Spectroscopy

Magnetically controlled states in quantum materials are central to their unique electronic and magnetic properties. However, direct momentum-resolved visualization of these states via angle-resolved photoemission spectroscopy (ARPES) has been hindered by the disruptive effect of magnetic fields on photoelectron trajectories. Here, we introduce an in situ method that is, in principle, capable of applying magnetic fields up to 1 T. This method uses substrates composed of nanomagnetic metamaterial arrays with alternating polarity. Such substrates can generate strong, homogeneous, and spatially confined fields applicable to samples with thicknesses up to the micron scale, enabling ARPES measurements under magnetic fields with minimal photoelectron trajectory distortion. Here, we demonstrate this minimal distortion with ARPES data taken on monolayer graphene. Our method paves the way for probing magnetic field-dependent electronic structures and studying field-tunable quantum phases with state-of-the-art energy-momentum resolutions.

Magnetic properties↗

Exciton diamagnetic shifts and valley Zeeman effects in monolayer WS 2 and MoS 2 to 65 Tesla

In bulk and quantum-confined semiconductors, magneto-optical studies have historically played an essential role in determining the fundamental parameters of excitons (size, binding energy, spin, dimensionality and so on). Here we report low-temperature polarized reflection spectroscopy of atomically thin WS 2 and MoS 2 in high magnetic fields to 65 T. Both the A and B excitons exhibit similar Zeeman splittings of approximately –230 μeV T–1 (g-factor ≃–4), thereby quantifying the valley Zeeman effect in monolayer transition-metal disulphides. Crucially, these large fields also allow observation of the small quadratic diamagnetic shifts of both A and B excitons in monolayer WS 2 , from which radii of ~1.53 and ~1.16 nm are calculated. Further, when analysed within a model of non-local dielectric screening, these diamagnetic shifts also constrain estimates of the A and B exciton binding energies (410 and 470 meV, respectively, using a reduced A exciton mass of 0.16 times the free electron mass). Lastly, these results highlight the utility of high magnetic fields for understanding new two-dimensional materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Upper critical field reaches 90 tesla near the Mott transition in fulleride superconductors

Controlled access to the border of the Mott insulating state by variation of control parameters offers exotic electronic states such as anomalous and possibly high-transition-temperature (T c ) superconductivity. The alkali-doped fullerides show a transition from a Mott insulator to a superconductor for the first time in three-dimensional materials, but the impact of dimensionality and electron correlation on superconducting properties has remained unclear. Here we show that, near the Mott insulating phase, the upper critical field H c2 of the fulleride superconductors reaches values as high as ~90 T—the highest among cubic crystals. This is accompanied by a crossover from weak- to strong-coupling superconductivity and appears upon entering the metallic state with the dynamical Jahn–Teller effect as the Mott transition is approached. Lastly, these results suggest that the cooperative interplay between molecular electronic structure and strong electron correlations plays a key role in realizing robust superconductivity with high-T c and high-H c2 .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Unambiguous identification and discovery of bacterial siderophores by direct injection 21 Tesla Fourier transform ion cyclotron resonance mass spectrometry

Under iron-limiting conditions, bacteria produce low molecular mass Fe(III) binding molecules known as siderophores to sequester the Fe(III), along with other elements, increasing their bioavailibility. Siderophores are thought to influence iron cycling and biogeochemistry in both marine and terrestrial ecosystems and hence the need for rapid, confident characterization of these compounds has increased. In this study, the type of siderophores produced by two marine bacterial species, Synechococcus sp. PCC 7002 and Vibrio cyclitrophicus 1F53, were characterized using a newly developed 21T Fourier Transform Ion Cyclotron Resonance Mass Spectrometer (FTICR MS) with direct injection electrospray ionization. This technique allowed for the rapid detection of synechobactins from Synechococcus sp. PCC 7002 as well as amphibactins from Vibrio cyclitrophicus 1F53 based on high mass accuracy and resolution allowing for observation of specific Fe isotopic peaks and fine isotopic structure enables highly confident identification of these sideropohores. When combined with molecular network analysis two new amphibactins were discovered and verified by tandem MS. These results show that high-field FTICR MS is a powerful technique that will greatly improve the ability to rapidly identify and discover metal binding species in the environment.

Environmental Molecular Sciences Laboratory↗

Pulsed-coil magnet systems for applying uniform 10–30 T fields to centimeter-scale targets on Sandia's Z facility

Sandia has successfully integrated the capability to apply uniform, high magnetic fields (10–30 T) to high energy density experiments on the Z facility. This system uses an 8-mF, 15-kV capacitor bank to drive large-bore (5 cm diameter), high-inductance (1–3 mH) multi-turn, multi-layer electromagnets that slowly magnetize the conductive targets used on Z over several milliseconds (time to peak field of 2–7 ms). This system was commissioned in February 2013 and has been used successfully to magnetize more than 30 experiments up to 10 T that have produced exciting and surprising physics results. These experiments used split-magnet topologies to maintain diagnostic lines of sight to the target. We describe the design, integration, and operation of the pulsed coil system into the challenging and harsh environment of the Z Machine. We also describe our plans and designs for achieving fields up to 20 T with a reduced-gap split-magnet configuration, and up to 30 T with a solid magnet configuration in pursuit of the Magnetized Liner Inertial Fusion concept.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coherent two-dimensional Fourier transform spectroscopy using a 25 Tesla resistive magnet

We performed nonlinear optical two-dimensional Fourier transform spectroscopy measurements using an optical resistive high-field magnet on GaAs quantum wells. Magnetic fields up to 25 T can be achieved using the split helix resistive magnet. Two-dimensional spectroscopy measurements based on the coherent four-wave mixing signal require phase stability. Therefore, these measurements are difficult to perform in environments prone to mechanical vibrations. Large resistive magnets use extensive quantities of cooling water, which causes mechanical vibrations, making two-dimensional Fourier transform spectroscopy very challenging. Here, we report on the strategies we used to overcome these challenges and maintain the required phase-stability throughout the measurement. A self-contained portable platform was used to set up the experiments within the time frame provided by a user facility. Furthermore, this platform was floated above the optical table in order to isolate it from vibrations originating from the resistive magnet. Finally, we present two-dimensional Fourier transform spectra obtained from GaAs quantum wells at magnetic fields up to 25 T and demonstrate the utility of this technique in providing important details, which are obscured in one dimensional spectroscopy.

47 OTHER INSTRUMENTATION↗