Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TARGET”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

CRISPR-Cas “Non-Target” Sites Inhibit On-Target Cutting Rates

CRISPR-Cas systems have become ubiquitous for genome editing in eukaryotic as well as bacterial systems. Cas9 forms a complex with a guide RNA (gRNA) and searches DNA for a matching sequence (target site) next to a protospacer adjacent motif (PAM). Once found, Cas9 cuts the DNA. Cas9 is revolutionary for the ability to change the RNA sequence and target a new site easily. However, while algorithms have been developed to predict gRNA-specific Cas9 activity, a fundamental biological understanding of gRNA-specific activity is lacking. Here, the number of PAM sites in the genome is effectively a large pool of inhibitory substrates, competing with the target site for the Cas9/gRNA complex. We demonstrate that increasing the number of non-target sites for a given gRNA reduces on-target activity in a dose-dependent manner. Furthermore, we show that the use of Cas9 mutants with increased PAM specificity toward a smaller subset of PAMs (or smaller pool of competitive substrates) improves cutting rates, while increased PAM promiscuity decreases cutting rates. Decreasing the potential search space by increasing PAM specificity provides a path toward improving on-target activity for slower high-fidelity Cas9 variants. Engineering improved PAM specificity to reduce the competitive search space offers an alternative strategy to engineer Cas9 variants with increased specificity and maintained on-target activity.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Baseline and Target Values for PV Forecasts: Toward Improved Solar Power Forecasting

Accurate solar power forecasting allows utilities to get the most out of the solar resources on their systems. To truly measure the improvements that any new solar forecasting methods can provide, it is important to first develop (or determine) baseline and target solar forecasting at different spatial and temporal scales. This paper aims to develop baseline and target values for solar forecasting metrics. These were informed by close collaboration with utility and independent system operator partners. The baseline values are established based on state-of-the-art numerical weather prediction models and persistence models. The target values are determined based on the reduction in the amount of reserves that must be held to accommodate the uncertainty of solar power output.

14 SOLAR ENERGY↗

Quantitative single-particle digital autoradiography with α-particle emitters for targeted radionuclide therapy using the iQID camera

Purpose: Alpha-emitting radionuclides exhibit a potential advantage for cancer treatments because they release large amounts of ionizing energy over a few cell diameters (50–80 μm), causing localized, irreparable double-strand DNA breaks that lead to cell death. Radioimmunotherapy (RIT) approaches using monoclonal antibodies labeled with α emitters may thus inactivate targeted cells with minimal radiation damage to surrounding tissues. Tools are needed to visualize and quantify the radioactivity distribution and absorbed doses to targeted and nontargeted cells for accurate dosimetry of all treatment regimens utilizing α particles, including RIT and others (e.g., Ra-223), especially for organs and tumors with heterogeneous radionuclide distributions. The aim of this study was to evaluate and characterize a novel single-particle digital autoradiography imager, the ionizing-radiation quantum imaging detector (iQID) camera, for use in α-RIT experiments. Methods: The iQID camera is a scintillator-based radiation detection system that images and identifies charged-particle and gamma-ray/x-ray emissions spatially and temporally on an event-by-event basis. It employs CCD-CMOS cameras and high-performance computing hardware for real-time imaging and activity quantification of tissue sections, approaching cellular resolutions. In this work, the authors evaluated its characteristics for α-particle imaging, including measurements of intrinsic detector spatial resolutions and background count rates at various detector configurations and quantification of activity distributions. The technique was assessed for quantitative imaging of astatine-211 ({sup 211}At) activity distributions in cryosections of murine and canine tissue samples. Results: The highest spatial resolution was measured at ∼20 μm full width at half maximum and the α-particle background was measured at a rate as low as (2.6 ± 0.5) × 10{sup −4} cpm/cm{sup 2} (40 mm diameter detector area). Simultaneous imaging of multiple tissue sections was performed using a large-area iQID configuration (ø 11.5 cm). Estimation of the {sup 211}At activity distribution was demonstrated at mBq/μg-levels. Conclusions: Single-particle digital autoradiography of α emitters has advantages over traditional film-based autoradiographic techniques that use phosphor screens, in terms of spatial resolution, sensitivity, and activity quantification capability. The system features and characterization results presented in this study show that the iQID is a promising technology for microdosimetry, because it provides necessary information for interpreting alpha-RIT outcomes and for predicting the therapeutic efficacy of cell-targeted approaches using α emitters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Methodology to Generate Decay Gamma Sources for the Second Target Station Full Target Assembly

This report details the specifics of applying the Position-Averaged Method to the target wedges and staves. The methodology used to calculate the decay gamma sources for a single target wedge to the calculation of the Second Target Station (STS) target assembly activation and the resulting decay gamma source terms are detailed in this report. The methodology has been applied to the entire STS target assembly including all of the target wedges, staves, shaft, and drive. The target staves and shaft have been vertically segmented to ensure the decay gamma source gradient is sufficiently captured. MCNP ® Code Version 6.2.0 with the RNUCS patch coupled with CINDER2008 from the AARE V1.0 package are the main tools used to calculate the decay gamma source terms.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-intensity laser-accelerated ion beam produced from cryogenic micro-jet target

We report on the successful operation of a newly developed cryogenic jet target at high intensity laser-irradiation. Using the frequency-doubled Titan short pulse laser system at Jupiter Laser Facility, Lawrence Livermore National Laboratory, we demonstrate the generation of a pure proton beam a with maximum energy of 2 MeV. Furthermore, we record a quasi-monoenergetic peak at 1.1 MeV in the proton spectrum emitted in the laser forward direction suggesting an alternative acceleration mechanism. Using a solid-density mixed hydrogen-deuterium target, we are also able to produce pure proton-deuteron ion beams. With its high purity, limited size, near-critical density, and high-repetition rate capability, this target is promising for future applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Backscatter measurements for NIF ignition targets (invited)

Backscattered light via laser-plasma instabilities has been measured in early NIF hohlraum experiments on two beam quads using a suite of detectors. A full aperture backscatter system and near backscatter imager (NBI) instrument separately measure the stimulated Brillouin and stimulated Raman scattered light. Both instruments work in conjunction to determine the total backscattered power to an accuracy of ~15%. In order to achieve the power accuracy we have added time-resolution to the NBI for the first time. This capability provides a temporally resolved spatial image of the backscatter which can be viewed as a movie.

42 ENGINEERING↗

Applications of mass spectrometry-based targeted and non-targeted lipidomics

Highlights: • Advances in mass spectrometry have expanded our knowledge of lipids. • Targeted and non-targeted lipidomics are powerful strategies with distinct features. • We briefly review the applications of these lipidomics strategies in lipid research. • Current limitations and challenges in lipidomics are also discussed. Recent advances in mass spectrometry have expanded our knowledge of lipids and lipid metabolic pathways involved in many (patho)physiological events. Targeted and non-targeted lipidomics are powerful analytical strategies with distinct features, and a combination of these two approaches is often employed to maximize the coverage of lipid species detected and quantified in complex biological matrices. This review briefly summarizes the applications of targeted and non-targeted lipidomics, mainly focusing on electrospray ionization–liquid chromatography–tandem mass spectrometry (ESI–LC–MS/MS), along with recent technical advances in the field. Current limitations and challenges in lipidomics and possible solutions are also discussed.

60 APPLIED LIFE SCIENCES↗

Coupled beam-target-moderator optimization for the Second Target Station

To support the design of the Second Target Station, that aims to provide the world’s highest peak brightness of cold neutrons, studies that optimize the dimensions of the target and moderators are invaluable. In this work, we investigate the influence of the target dimensions and beam profile on the performance and optimal size of the moderators. We perform optimization runs with detailed MCNP6.2 simulations using high-fidelity unstructured mesh geometries generated from parametrized CAD models. We demonstrate that small changes in target height do not influence the moderator performance if the beam dimensions are chosen adequately. We quantify the effect of beam footprint and target width on the moderator performance and show that the optimal moderator dimensions are insensitive to limited changes in target and beam profile.

Dakota↗

Design of protein-binding proteins from the target structure alone

The design of proteins that bind to a specific site on the surface of a target protein using no information other than the three-dimensional structure of the target remains a challenge. Here we describe a general solution to this problem that starts with a broad exploration of the vast space of possible binding modes to a selected region of a protein surface, and then intensifies the search in the vicinity of the most promising binding modes. We demonstrate the broad applicability of this approach through the de novo design of binding proteins to 12 diverse protein targets with different shapes and surface properties. Biophysical characterization shows that the binders, which are all smaller than 65 amino acids, are hyperstable and, following experimental optimization, bind their targets with nanomolar to picomolar affinities. We succeeded in solving crystal structures of five of the binder–target complexes, and all five closely match the corresponding computational design models. Experimental data on nearly half a million computational designs and hundreds of thousands of point mutants provide detailed feedback on the strengths and limitations of the method and of our current understanding of protein–protein interactions, and should guide improvements of both. Our approach enables the targeted design of binders to sites of interest on a wide variety of proteins for therapeutic and diagnostic applications.

59 BASIC BIOLOGICAL SCIENCES↗