Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TAP data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Data eye monitor method and apparatus

An apparatus and method for providing a data eye monitor. The data eye monitor apparatus utilizes an inverter/latch string circuit and a set of latches to save the data eye for providing an infinite persistent data eye. In operation, incoming read data signals are adjusted in the first stage individually and latched to provide the read data to the requesting unit. The data is also simultaneously fed into a balanced XOR tree to combine the transitions of all incoming read data signals into a single signal. This signal is passed along a delay chain and tapped at constant intervals. The tap points are fed into latches, capturing the transitions at a delay element interval resolution. Using XORs, differences between adjacent taps and therefore transitions are detected. The eye is defined by segments that show no transitions over a series of samples. The eye size and position can be used to readjust the delay of incoming signals and/or to control environment parameters like voltage, clock speed and temperature.

47 OTHER INSTRUMENTATION↗

Single $\pi ^0$ production off neutrons bound in deuteron with linearly polarized photons

The quasifree γ → d → π 0 n(p) photon beam asymmetry, Σ, has been measured at photon energies, E γ , from 390 to 610 MeV, corresponding to center of mass energy from 1.271 to 1.424 GeV, for the first time. The data were collected in the A2 hall of the MAMI electron beam facility with the Crystal Ball and TAPS calorimeters covering pion center-of-mass angles from 49° to 148°. In this kinematic region, polarization observables are sensitive to contributions from the Δ(1232) and N(1440) resonances. The extracted values of Σ have been compared to predictions based on partial-wave analyses (PWAs) of the existing pion photoproduction database. Our comparison includes the SAID, MAID and Bonn–Gatchina analyses; while a revised SAID fit, including the new Σ measurements, has also been performed. In addition, isospin symmetry is examined as a way to predict π 0 n photoproduction observables, based on fits to published data in the channels π 0 p, π + n and π – p.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Literature Data on Foam Fracturing Fluid

At the beginning of this project, the Temple team spent significant effort to collect data relevant to foam fracturing. More than 40 articles/reports were found in the open literature that reported the properties of aqueous foams under various testing conditions. The foam properties included viscosity and stability in terms of half-life, while were influenced by the foam quality, shear rate, temperature, pressure, as well as surfactants and additives used in making the foam base solutions. As a result, more than 1100 data points were collected, which are included in a master worksheet named "Literature data on Foam Fracturing Fluid". These data points are organized based on following parameters: 1. Literature source, including authors and publication year 2. Gaseous phase (e.g. CO2, N2) 3. Liquid phase (e.g. tap water, DI water, salt water) 4. Surfactants and their concentrations 6. Additives 7. Foam quality 8. Pressure 9. Temperature 10. Viscosity 11. Foam stability, which was characterized by its half-life: Half-life Foam study data base with data analysis was completed and a webpage is designed hosted on public server at https://surfactant-dashboard.herokuapp.com

15 GEOTHERMAL ENERGY↗

2012 SRNL-EM Vane Rheology Results

The vane method has been shown to be an effective tool in measuring the yield stress of both settled and mixed slurries in laboratory bench scale conditions in supporting assessments of both actual and simulant waste slurries. The vane has also been used to characterize dry powders and granular solids, the effect of non-cohesive solids with interstitial fluids and used as a guide to determine if slip is present in the geometries typically used to perform rheological flow curve measurements. The vane has been extensively characterized for measuring the shear strength in soils in both field and laboratory studies. The objectives for this task are: Fabricate vane instrument; Bench top testing to further characterize the effect of cohesive, non-cohesive, and blends of cohesive/non-cohesive simple simulants; Data from measurement of homogenized and settled bed of Kaolin sludge and assessment of the technology. In this document, the assessment using bench scale measurements of non-cohesive materials (beads) and cohesive materials (kaolin) is discussed. The non-cohesive materials include various size beads and the vane was assessed for depth and deaeration (or packing) via tapping measurements. For the cohesive (or non-Newtonian) materials, flow curves and yield stress measurements are performed using the vane and this data is compared to the traditional concentric cylinder flow curve measurement. Finally, a large scale vane was designed, fabricated, and tested with the cohesive (or non-Newtonian) materials to determine how a larger vane performs in measuring the yield stress and flow curve of settled cohesive solids.

47 OTHER INSTRUMENTATION↗

Tools for Assessing Performance: FY23-Q1 Report [Slides]

LANL was tasked with working with NREL to implement QUIC within the TAP API by the end of Q1, FY2023. If QUICURB cannot be implemented in a way that it can be run outside of the QUIC platform, there will be no further R&D funding for QUIC development. QUIC includes a graphical user interface that imports and preprocesses the various input data streams (3D building databases, ambient wind, vegetation, etc.) and writes them in a format that the QUICURB Fortran executable requires. In order to interface with the TAP API, a Python script was developed that would replace the functionality previously only available within QUICGUI. LANL worked with NREL to test the Python script to ensure that it was operation and fulfilled the requirements.

58 GEOSCIENCES↗

Thermal Analysis of Rare Earth Additions to HY100

This paper discusses the results of a series of experiments on rare earth additions to HY100. Previous work has found little or no refinement to occur with rare earth additions to this alloy. Thermal analysis has been used to provide a better understanding of this and assist in the development of a suitable grain refiner. Heats of HY100 were melted in an induction furnace and tapped into a small hand ladle. Thermal analysis cups were poured from the ladle, and the resulting cooling data recorded. Heats with no additions and 0.3 wt.% rare earth silicide were poured. Commercial software analyzed the cooling curves to determine the liquidus and solidus temperatures. A manual analysis was employed for identifying the peritectic and other reactions. Examination of the cooling curves detected the liquidus, solidus and even peritectic reactions. It was observed that the solidification changed with the rare earth silicide or engineered grain refiner additions. Additional phase reactions appeared before the solidus were not present in the baseline heat. Phase identification was done with thermodynamic calculations. The solidus, peritectic and liquidus were found. Rare earth inclusions were observed in the microstructure of the treated steel. Interestingly, macrostructure examination indicated no reduction in overall grain size. Thermodynamic predictions also indicated that the inclusions formed late during solidification. It was postulated that the additions caused a change in solidification but those occurred late enough during freezing that the resulting microstructure was not affected.

36 MATERIALS SCIENCE↗

Energy Information Systems: From the Basement to the Boardroom

A significant buildings energy reduction opportunity exists in the office sector, given that this market segment typically is an early adopter of new technology. There is a rising trend towards smart and connected offices through the internet of things (IoT) that provides new opportunities for operational efficiency and environmental sustainability practices. Leading commercial real estate companies have begun to shift from individual building automation systems (BAS) to partially integrated and automated systems such as energy information systems (EIS). In both the United States and India, organizations are seeking operational excellence, enhanced tenant relationships, and topline growth. Hence it is imperative to engage the executives with decision-making power, by tapping into their interest in sustainability, corporate social responsibility, and innovation. This expansion of interest can enable data-driven decisions, strong energy investments, and deeper energy benefits, and would drive innovation in this field. However, none of this would be possible without robust, consistent building energy information to provide visibility across all the levels of decision making, i.e. from the basement where the facilities staff take operational action to the boardroom where the executives make investment decisions. Price, security, and ease of use remain barriers to the adoption and pervasive use of promising EIS technologies in commercial office buildings. We believe that these barriers can be addressed through the development of ready, simplified, consistent, commercially available, low-cost EIS-in-a-box packages, that have a pre-defined set of hardware components and software features and functionality that are pertinent to a particular building sector. These simplified, sector-specific EIS packages can help to obviate the need for customization, and enhance ease of use, thereby enabling scale-up, in order to facilitate building energy savings. The EIS-in-a-box are adaptable in both U.S. and Indian office buildings, and potentially beyond these two countries.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Synthetic data generation for machine learning model training for energy theft scenarios using cosimulation

Abstract Technical and non‐technical losses in distribution circuits result in significant economic costs to power utilities. One type of non‐technical loss is energy theft by various means including illegal tapping of feeders, bypassing the meter, and billing fraud. These losses are usually hard to detect, and can remain undetected for long periods of time. Machine learning models have been proven effective in detecting these conditions, but rely on the availability of large, good‐quality training data sets. The problem is exacerbated by the imbalanced nature of data related to these conditions—energy theft, though costly, is very rare. The available data sets generally have very few samples of theft with most of the data pertaining to normal operation. Such data sets are generally not suitable to train machine learning models. In this paper, an overview of energy theft detection techniques, the challenges with their data needs, and the limitations of current techniques to bridge such data limitations is presented. A co‐simulation framework is proposed to generate reliable training data for machine learning algorithms for theft detection. An example scenario is presented and a machine learning model is built to detect certain kinds of energy theft.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Tools Assessing Performance

For the distributed wind industry, it can be challenging to accurately predict the performance and annual energy production of projects prior to their installation. The U.S. Department of Energy’s Tools Assessing Performance (TAP) project aims to improve wind resource characterization, thereby reducing the uncertainty of project performance and financing costs, increasing consumer confidence, and lowering the levelized cost of distributed wind energy. A collaborative effort among DOE National Laboratories, TAP will create a computational framework that provides the distributed wind community with access to newly developed wind resource data and modeling capabilities. These capabilities will allow users to perform timely and accurate performance assessments for distributed wind projects at locations across the United States.

wind, distributed, tools, performance↗

Exact Optimal Power Dispatch in Unbalanced Distribution Systems With High PV Penetration

Smart inverters provide additional control capability to help optimize the operation of distribution systems. This paper proposes a framework for exact optimal active and reactive power dispatch of distributed photovoltaic (PV) generation, switched capacitors, and tap changers in large multi-phase unbalanced distribution systems. The objectives of the optimal dispatch are minimization of the energy loss, PV active power curtailment, and capacitor and tap changer switching operations, in addition to elimination of voltage violations and reverse power flow. The optimization problem is formulated in rectangular coordinates as a nonlinear, nonconvex problem. Effective computational strategies are proposed to allow the application of predictorcorrector primal-dual interior point method to solve optimization problems in real-time with a large number of constraints and variables, including discrete variables corresponding to switched capacitors and tap changers. The accuracy of the numerical solution and the ability to implement the proposed framework are validated using the unbalanced multi-phase IEEE 34-bus and EPRI 2,998-bus distribution systems with 15-minute load and PV data. The results show a significant loss reduction and complete removal of both voltage violations and reverse power flow.

Nguyen, Quan (ORCID:0000000347769557)↗

Identifying schools at high-risk for elevated lead in drinking water using only publicly available data

Estimating the risk of lead contamination of schools' drinking water at the State level is a complex, important, and unexplored challenge. Variable water quality among water systems and changes in water chemistry during distribution affect lead dissolution rates from pipes and fittings. In addition, the locations of lead-bearing plumbing materials are uncertain. We tested the capability of six machine learning models to predict the likelihood of lead contamination of drinking water at the schools' taps using only publicly available datasets. The predictive features used in the models correspond to those with a proven correlation to the dominant, but commonly unavailable, factors that govern lead leaching: the presence of lead-bearing plumbing materials and water quality conducive to lead corrosion. By combining water chemistry data from public reports, socioeconomic information from the US census, and spatial features using Geographic Information Systems, we trained and tested models to estimate the likelihood of lead contaminated tap water in over 8,000 schools across California and Massachusetts. Our best-performing model was a Random Forest, with a 10-fold cross validation score of 0.88 for Massachusetts and 0.78 for California using the average Area Under the Receiver Operating Characteristic Curve (ROC AUC) metric. The model was then used to assign a lead leaching risk category to half of the schools across California (the other half was used for training). There was good agreement between the modeled risk categories and the actual lead leaching outcomes for every school; however, the model overestimated the lead leaching risk in up to 17% of the schools. This model is the first of its kind to offer a tool to predict the risk of lead leaching in schools at the State level. Further use of this model can help deploy limited resources more effectively to prevent childhood lead exposure from school drinking water.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Data-Driven Preemptive Voltage Monitoring and Control Using Probabilistic Voltage Sensitivities

Increased penetration levels of distributed variable renewable generation can cause random voltage fluctuations and violations at multiple nodes. Traditional methods of voltage control typically involve reactionary responses of capacitor banks, tap changers, and recently even smart inverters. But because of the lack of foresight in voltage violations, these controls are ineffective to completely mitigate the issue. Therefore, new methods of predicting voltage violations subject to random power injection changes in the distribution network are needed, which can be used to guide optimal and dynamic methods of voltage control. This work lays the foundation for such preemptive voltage monitoring and control by proposing an analytical and sensor data-driven voltage sensitivity analysis method. Driven by stochastic data and forecasts, the method can be used to develop probabilistic voltage sensitivities and consequently to predict system nodes with high likelihood of voltage limit violations. The effectiveness of this method is tested on IEEE 69-node distribution system integrated with distributed solar. The results demonstrate the proposed method's ability to successfully predict nodes with high probability of voltage violations for a specific time-series simulation. The results also demonstrate the ability to guide timely power injection control actions to mitigate future voltage violations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Black Carbon at the Mt. Bachelor Observatory Field Campaign Report

This campaign was initiated to measure refractory black carbon (rBC, as defined in Schwarz et al. (2010)) at the Mt. Bachelor Observatory (MBO) using the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility single-particle soot photometer (SP2; unit 54). MBO is a high-elevation site located on the summit of Mt. Bachelor in central Oregon, USA (43.979°N, 121.687°W, 2,763 meters ASL). This site is operated by Professor Dan Jaffe’s group at the University of Washington Bothell and has been used continuously as an atmospheric observatory for the past 12 years (Jaffe et al., 2005; Gratz et al., 2014). The location of MBO allows frequent sampling of the free troposphere along with a wide array of plumes from regional and distant sources. MBO is currently supported with funding from the National Science Foundation (NSF) to the Principal Investigator (PI; D. Jaffe) via the project “Influence of Free Tropospheric Ozone and PM on Surface Air Quality in the Western U.S.” (#1447832) covering the period 03/15/2015 to 02/28/2018. The SP2 instrument from Droplet Measurement Technologies provides particle-resolved measurements of rBC mass loading, size and mass distributions, and mixing state. The SP2 was installed at MBO on 6/27/2016 and ran through 9/23/2016. Additional measurements at MBO during this campaign included carbon monoxide (CO), fine particulate matter (PM1), aerosol light scattering coefficients (σscat) at three wavelengths using a TSI nephelometer, aerosol absorption coefficients (σabs) with the Brechtel tricolor absorption photometer (TAP), aerosol number size distributions with a scanning mobility particle sizer spectrometer (SMPS), and black carbon (eBC) with an aethalometer. BC data from this campaign have been submitted to the ARM Data Archive. Black carbon (BC) is the predominant light-absorbing aerosol constituent in the atmosphere, and is estimated to exert a positive radiative forcing second only to CO 2 (Ramanathan and Carmichael, 2008). One of the largest sources of BC globally is biomass burning (BB). (Akagi et al., 2011; Andreae and Merlet, 2001; Bond et al., 2013; Bond et al., 2004; Reid et al., 2005b): a source that is likely to increase in the Western U.S. due to climate change (Dennison et al., 2014; Abatzoglon and Williams, 2016; Westerling et al., 2006). Given the likely increased role of BB aerosol in atmospheric forcing, we need to improve our understanding of the physical and optical properties of aged BB aerosol. During the SP2 deployment period at MBO we observed seven BB events, all of which originated from the Gap Fire in Northern California, which burned 33,867 acres in the Klamath National Forest (https://inciweb.nwcg.gov/incident/4997/). Heavy smoke plumes from this fire were transported to MBO from 8/29/2016 to 8/31/2016. We calculated back-trajectories using the National Oceanic and Atmospheric Administration (NOAA) Hybrid Single-Particle Lagrangian Integrated Trajectory (HYSPLIT) model, version 4 (Draxler, 1999; Draxler and Hess, 1997, 1998; Stein et al., 2015) to confirm transport from the fire locations to MBO. We identified the fire locations using moderate resolution imaging spectroradiometer (MODIS) satellite-derived active fire counts (Justice et al., 2002). Transport time for all of the BB events ranged from 8 to 32 hours.

54 ENVIRONMENTAL SCIENCES↗

Data-Driven Preemptive Voltage Monitoring and Control Using Probabilistic Voltage Sensitivities: Preprint

Increased penetration of distributed variable re-newable generation may cause random voltage fluctuations and violations at multiple nodes. Traditional methods of voltage control typically involve reactionary responses of capacitor banks, tap changers, and recently even smart inverters. But due to the lack of foresight in voltage violations, these controls are ineffective to completely mitigate the issue. Therefore, new methods of predicting voltage violations subject to random power injection changes in the distribution network is needed, which can be used to guide optimal and dynamic methods of voltage control. This work lays the foundation for such preemptive voltage monitoring and control by proposing an analytical and sensor data-driven voltage sensitivity analysis method. Driven by stochastic data and forecasts, the method can be used to develop probabilistic voltage sensitivities and consequently to predict system nodes with high likelihood of voltage limit violations. The effectiveness of this method is tested on IEEE 69 node distribution system integrated with distributed solar. The results demonstrate the proposed method's ability to successfully predict nodes with high probability of voltage violations for a specific time series simulation. The results also demonstrate the ability to guide timely power injection control actions to mitigate future voltage violations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Complex Endomembrane System in the Archaeon Ignicoccus hospitalis Tapped by Nanoarchaeum equitans

Based on serial sectioning, focused ion beam scanning electron microscopy (FIB/SEM), and electron tomography, we depict in detail the highly unusual anatomy of the marine hyperthermophilic crenarchaeon, Ignicoccus hospitalis. Our data support a complex and dynamic endomembrane system consisting of cytoplasmic protrusions, and with secretory function. Moreover, we reveal that the cytoplasm of the putative archaeal ectoparasite Nanoarchaeum equitans can get in direct contact with this endomembrane system, complementing and explaining recent proteomic, transcriptomic and metabolomic data on this inter-archaeal relationship. In addition, we identified a matrix of filamentous structures and/or tethers in the voluminous inter-membrane compartment (IMC) of I. hospitalis, which might be responsible for membrane dynamics. Overall, this unusual cellular compartmentalization, ultrastructure and dynamics in an archaeon that belongs to the recently proposed TACK superphylum prompts speculation that the eukaryotic endomembrane system might originate from Archaea.

3D↗

Enabling Realistic Communications Evaluations for ADMS

Increasing penetration levels of inverter-based distributed energy resources (DERs) in distribution systems are creating challenges in system operation. Currently, wired or proprietary wireless communications are used by advanced distribution management systems (ADMS) to detect the state of the system and control the DERs for optimal operation. Wireless communications are an alternative solution that can enable connectivity between the dispersed assets used in distribution system applications. As demand for the seamless integration of distributed energy resources (DERs) continues to increase, proper networking and communications systems are becoming important to support the DER infrastructure. This report summarizes validation of a private wireless LTE network in a laboratory environment. The purpose of this work is to 1) demonstrate the effectiveness of private wireless LTE communication for grid applications and 2) provide a means of evaluating latency and overall performance of wireless communication in grid applications. First, private wireless LTE communication was validated in a direct transfer trip relaying scenario as an example of one-way communications using grid equipment. This study provided a baseline understanding of the variation in latency for seven different kinds of wireless scenarios shown in Figure A below. As expected, weak (attenuated) wireless signal-based communication yielded the widest ranges in latency. When higher priority was set for the trip signal communication, this resulted in lower latency in communication timing. In the final phase of this project, the private wireless LTE network was validated using two-way communications in an advanced distribution management system (ADMS) testbed which was developed in the ESIF at NREL. The purpose of this was to study the impact of wireless communication on grid performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

aostap.b1

The aostap.a0 data is used to calculate absorbance and transmittance

54 ENVIRONMENTAL SCIENCES↗

A Data-Driven Approach to Dynamic Var Compensator Placement for Local Voltage Stabilization on Feeders with High PV Penetration

Distribution feeders with a high penetration of distributed photovoltaic (PV) systems can experience voltage variability caused by the changing load flow injections corresponding to the availability of the solar resource. The rapid, uncontrolled voltage range fluctuations can affect the system. Tap-changing voltage regulators, switched capacitors, and smart inverter functions have been used to stabilize voltage. However, in some cases, when these options are insufficient or unavailable, dedicated reactive power control devices such as dynamic var compensators (DVCs) can be used for local voltage stabilization. This paper introduces a statistical framework to characterize voltage variability and stabilization, proposes a data-driven approach to DVC placement, and presents the results of a planning study on a real feeder using real data.

Reiman, Andrew P.↗