Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TANKS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Liquid Hydrogen Tank Chill and No-Vent Fill Prediction Using Computational Fluid Dynamics

Cryogenic tank chill and fill is an important cryogenic fluid management (CFM) technology that supports and enables many of NASA’s long-duration space missions. For no-vent fill, the receiver tank pressure remains below the supply tank pressure during the entire duration of the fill so that the tank does not require venting. This is especially advantageous for tank fill operations in low gravity where the position of the liquid is not always known and venting the tank may cause loss of propellant by venting liquid. In lieu of expensive tests conducted on-orbit, accurate computational models capable of predicting receiver tank pressure during cryogenic propellant tank fill may be used to reduce system and propellant mass as well as mission risk. However, these numerical models must be validated or anchored to test data. This study presents a computational fluid dynamics (CFD) model with conjugate heat transfer that is used to predict a liquid hydrogen tank chill and no-vent fill ground test conducted at Lewis Research Center (now Glenn Research Center) in 1991. The specific test case chosen for model validation implemented an upward-facing jet near the bottom of a cylindrical 34 liter tank. CFD predictions are compared to experimental measurements of tank pressure, fill level, fluid temperatures, and wall temperatures. The CFD results show reasonable agreement to the test data but overpredict the pressure collapse near the end of the fill despite the liquid jet penetrating the liquid-vapor interface. Several sensitivity studies are considered due to notable uncertainties in the experiment.

Computational Fluid Dynamics↗

Liquid Hydrogen Tank Chill and No-Vent Fill Prediction using Computational Fluid Dynamics

Cryogenic tank chill and fill is an important cryogenic fluid management technology that supports and enables many of NASA’s long-duration space missions. For no-vent fill, the receiver tank pressure remains below the supply tank pressure during the entire duration of the fill so that the tank does not require venting. This is especially advantageous for tank fill operations in low gravity where the position of the liquid is not always known and venting the tank may cause loss of propellant by venting liquid. In lieu of expensive tests conducted on-orbit, accurate computational models capable of predicting receiver tank pressure during cryogenic propellant tank fill may be used to reduce system and propellant mass as well as mission risk. However, these numerical models must be validated or anchored to test data. This study presents computational fluid dynamics (CFD) models with conjugate heat transfer that are used to predict a liquid hydrogen tank chill and no-vent fill ground test conducted at Lewis Research Center (now Glenn Research Center) in 1991. The specific test case chosen for model validation implemented an upward-facing jet near the bottom of a cylindrical 34-liter tank. CFD predictions are compared to experimental measurements of tank pressure, fill level, and wall temperature. The CFD results show reasonable agreement to the test data but overpredict the pressure collapse near the end of the fill despite the liquid jet penetrating the liquid-vapor interface.

Computational Fluid Dynamics↗

Nodal Modeling of Tank Pressurization and Draining using a Multi-Node-Ullage Approach

The purpose of the pressurization system in liquid rocket propulsion is to control the pressure in the gas space of the propellant tank (known as the ullage space) and the propellant mass flowrate to the engine. A mathematical model is required to predict the amount of pressurant necessary to ensure that pressure and temperature levels inside the tank remain within acceptable limits and that the propellant pressure leaving the tank satisfies the net positive suction pressure (NPSP) requirement of the pump feeding the engine. Nodal codes typically model tank pressurization and draining using a single node to represent the ullage and a single node to represent the propellant. As the tank drains, the ullage node grows and the propellant node shrinks. The heat transfer between ullage to wall and ullage to propellant is governed by natural convection. Designers of liquid propulsion systems often use empirical correlations to estimate the “Collapse Factor” which represents the ratio of pressurant required with heat transfer and the amount of pressurant required without heat transfer. A single node ullage model of tank pressurization was developed using GFSSP to compute the collapse factor reasonably well and later was used to model tank pressurization during test firing of the FASTRAC rocket engine. The predicted tank pressure compared well with the test data. In the early 1970’s, pressurization and drain tests with liquid methane were performed at NASA Lewis Research Center in a vacuum chamber. A 5 ft diameter spherical aluminum tank was tested to drain from 95% to 5% full using gaseous helium, hydrogen, nitrogen and methane as pressurant. Tests were conducted with different pressurant inlet temperatures and drain times. Measured data include pressurant requirement, amount of pressurant condensed, and ullage and wall temperatures at various heights in the ullage space at the end of draining. A single node GFSSP model was developed to simulate helium pressurization of the methane tank. Predicted helium consumption was 8-23% less than measured. The average error of the six test cases was 16%. A single ullage node with multiple solid node model was developed using Thermal Desktop. Predicted helium consumption compares with the test data within 2%. This paper describes the development of a GFSSP multi-node ullage model of the test configuration and compares the predicted pressurant consumption for both helium and autogenous pressurization using gaseous methane with experimental as well as TD predictions.

Nodal Model↗

Design considerations for honeycomb double-bubble tanks utilized in aerospace vehicles

Future earth-to-orbit vehicles will utilize reusable internal fuel tanks requiring most of the vehicle volume. Because weight reduction and volumetric efficiency are essential, these tanks will be integral to the vehicle structure, and the vehicle cross section will dictate the size and shape of the tank. For a fuselage with a noncircular cross section, a multibubble tank configuration may be employed. Multibubble tanks offer a reduction in tank weight over a single-lobe tank or several cylindrical tanks in a noncircular cross section but sacrifice the efficiency of utilizing the entire fuselage cross section. This paper includes a general configuration analysis of a double-bubble tank, a materials and efficiency study, and a complete mission design analysis centers on sizing the tank to withstand ascent and reentry loads while minimizing the structural weight.

Lentz, Christopher A.↗

Experimental Investigation of Jet-Induced Mixing of a Large Liquid Hydrogen Storage Tank

Experiments have been conducted to investigate the effect of fluid mixing on the depressurization of a large liquid hydrogen storage tank. The test tank is approximately ellipsoidal, having a volume of 4.89 m(exp 3) and an average wall heat flux of 4.2 W/m(exp 2) due to external heat input. A mixer unit was installed near the bottom of the tank to generate an upward directed axial jet flow normal to the liquid-vapor interface. Mixing tests were initiated after achieving thermally stratified conditions in the tank either by the introduction of hydrogen gas into the tank or by self-pressurization due to ambient heat leak through the tank wall. The subcooled liquid jet directed towards the liquid-vapor interface by the mixer induced vapor condensation and caused a reduction in tank pressure. Tests were conducted at two jet submergence depths for jet Reynolds numbers from 80,000 to 495,000 and Richardson numbers from 0.014 to 0.52. Results show that the rate of tank pressure change is controlled by the competing effects of subcooled jet flow and the free convection boundary layer flow due to external tank wall heating. It is shown that existing correlations for mixing time and vapor condensation rate based on small scale tanks may not be applicable to large scale liquid hydrogen systems.

Lin, C. S.↗

Water Tank with Capillary Air/Liquid Separation

A bladderless water tank (see figure) has been developed that contains capillary devices that allow it to be filled and emptied, as needed, in microgravity. When filled with water, the tank shields human occupants of a spacecraft against cosmic radiation. A membrane that is permeable by air but is hydrophobic (neither wettable nor permeable by liquid water) covers one inside surface of the tank. Grooves between the surface and the membrane allow air to flow through vent holes in the surface as the tank is filled or drained. A margin of wettable surface surrounds the edges of the membrane, and all the other inside tank surfaces are also wettable. A fill/drain port is located in one corner of the tank and is covered with a hydrophilic membrane. As filling begins, water runs from the hydrophilic membrane into the corner fillets of the tank walls. Continued filling in the absence of gravity will result in a single contiguous air bubble that will be vented through the hydrophobic membrane. The bubble will be reduced in size until it becomes spherical and smaller than the tank thickness. Draining the tank reverses the process. Air is introduced through the hydrophobic membrane, and liquid continuity is maintained with the fill/drain port through the corner fillets. Even after the tank is emptied, as long as the suction pressure on the hydrophilic membrane does not exceed its bubble point, no air will be drawn into the liquid line.

Ungar, Eugene K.↗

Multifunctional Tanks for Spacecraft

A document discusses multifunctional tanks as means to integrate additional structural and functional efficiencies into designs of spacecraft. Whereas spacecraft tanks are traditionally designed primarily to store fluids and only secondarily to provide other benefits, multifunctional tanks are designed to simultaneously provide multiple primary benefits. In addition to one or more chamber(s) for storage of fluids, a multifunctional tank could provide any or all of the following: a) Passageways for transferring the fluids; b) Part or all of the primary structure of a spacecraft; c) All or part of an enclosure; d) Mechanical interfaces to components, subsystems, and/or systems; e) Paths and surfaces for transferring heat; f)Shielding against space radiation; j) Shielding against electromagnetic interference; h) Electrically conductive paths and surfaces; and i) Shades and baffles to protect against sunlight and/or other undesired light. Many different multifunctional-tank designs are conceivable. The design of a particular tank can be tailored to the requirements for the spacecraft in which the tank is to be installed. For example, the walls of the tank can be flat or curved or have more complicated shapes, and the tank can include an internal structure for strengthening the tank and/or other uses.

Collins, David H.↗

Strain-Gauge Measurement of Weight of Fluid in a Tank

A method of determining the amount of fluid in a tank is based on measurement of strains induced in tank supports by the weight of the fluid. Unlike most prior methods, this method is nonintrusive: there is no need to insert instrumentation in the tank and, hence, no need to run wires, cables, or tubes through the tank wall. Also unlike most prior methods, this method is applicable even if the fluid in the tank is at supercritical pressure and temperature, because it does not depend on the presence of a liquid/gas interface (as in liquid-level-measuring methods). The strain gauges used in this method may be of two types: foil and fiber-optic. Four foil gauges (full bridge) are mounted on each of the tank-supporting legs. As the tank is filled or emptied, the deformation in each leg increases or decreases, respectively. Measured deformations of all legs are added to obtain a composite deformation indicative of the change in weight of the tank plus fluid. An initial calibration is performed by recording data at two points (usually, empty and full) for which the mass or weight of fluid is known. It is assumed that the deformations are elastic, so that the line passing through the two points can be used as a calibration curve of mass (or weight) of fluid versus deformation. One or more fiber-optic gauges may be used instead of the foil gauges. The resolution of the fiber-optic and foil gauges is approximately the same, but the fiber-optic gauges are immune to EMI (electromagnetic interference), are linear with respect to temperature over their entire dynamic range (as defined by the behavior of the sample), and measure thermally induced deformations as predictable signals. Conversely, long term testing has demonstrated that the foil gauges exhibit an erratic behavior whenever subjected to direct sun radiation (even if protected with a rubberized cover). Henceforth, for deployment in outdoor conditions, fiber-optic gauges are the only option if one is to rely on the system for an extended period of time when a recalibration procedure may not be acceptable. A set of foil gauges had been tested on the supports of a 500-gallon (1,900-liter) tank. The gauges were found to be capable of measuring the deformations (up to 22 micro-strain) that occurred during filling and emptying of the tank. The fluid masses calculated from the gauge readings were found to be accurate within 4.5 percent. However, the reliability of the foil gauges over a few hours was not acceptable. Therefore, the foil sensor system is acceptable for use only in controlled environments (complete shade, or indoors).

Figueroa, Jorge↗

External Tank Program - Legacy of Success

The largest single element of Space Shuttle is the External Tank (ET), which serves as the structural backbone of the vehicle during ascent and provides liquid propellants to the Orbiter s three Main Engines. The ET absorbs most of the seven million pounds of thrust exerted by the Solid Rocket Boosters and Main Engines. The design evolved through several block changes, reducing weight each time. Because the tank flies to orbital velocity with the Space Shuttle Orbiter, minimization of weight is mandatory, to maximize payload performance. The initial configuration, the standard weight tank, weighed 76,000 pounds and was an aluminum 2219 structure. The light weight tank weighed 66,000 pounds and flew 86 missions. The super light weight tank weighed 58,500 pounds and was primarily an aluminum-lithium structure. The final configuration and low weight enabled system level performance sufficient for assembly of the International Space Station in a high inclination orbit, vital for international cooperation. Another significant challenge was the minimization of ice formation on the cryogenic tanks. This was essential due to the system configuration and the choice of ceramic thermal protection system materials on the Orbiter. Ice would have been a major debris hazard. Spray on foam insulation materials served multiple functions including thermal insulation, conditioning of cryogenic propellants, and thermal protection for the tank structure during ascent and entry. The tank is large, and unique manufacturing facilities, tooling, and handling, and transportation operations were developed. Weld processes and tooling evolved with the design as it matured through several block changes. Non Destructive Evaluation methods were used to assure integrity of welds and thermal protection system materials. The aluminum-lithium alloy was used near the end of the program and weld processes and weld repair techniques had to be refined. Development and implementation of friction stir welding was a substantial technology development incorporated during the Program. Automated thermal protection system application processes were developed for the majority of the tank surface. Material obsolescence was an issue throughout the multi-decade program. Process controls were implemented to assure cleanliness in the production environment, to control contaminants, and to preclude corrosion. Each tank was accepted via rigorous inspections, including non-destructive evaluation techniques, proof testing, and all systems testing. In the post STS-107 era, the project focused on ascent debris risk reduction. This was accomplished via stringent process controls, post flight assessment using substantially improved imagery, and selective redesigns. These efforts were supported with a number of test programs to simulate combined environments. The debris risk was reduced by two orders of magnitude. During this time a major natural disaster was overcome when hurricane Katrina damaged the manufacturing facility. Numerous lessons from these efforts, the manufacturing and material processing issues, the key design features, and evolution of the design will be discussed.

Pilet, Jeffery C.↗

Sloshing in Liquid Hydrogen and LOX Propellant Tanks After Main Engine Cut-off

NASA Marshall Space Flight Center is designing and developing the Main Propulsion System (MPS) for Ares launch vehicles. The objective of this study is to calculate the sloshing forces and moments in the LH2 and LO2 propellant tanks using a CFD/VOF analysis under realistic flight conditions. Propellant sloshing in the liquid hydrogen (LH2) and the liquid oxygen (LO2) propellant tanks after Main Engine Cut Off (MECO) was modeled using the Volume of Fluid (VOF) module of the computational fluid dynamics code, CFD-ACE+. The present simulation shows that there are substantial sloshing side forces acting on the LH2 tank during the deceleration of the vehicle after MECO. The LH2 tank features a side wall drain pipe. The side loads result from the residual propellant mass motion in the LH2 tank which is initiated by the stop of flow into the drain pipe at MECO. The simulations show that radial force on the LH2 tank wall is less than 50 lbf and the radial moment calculated based up the center of gravity of the vehicle is predicted to be as high as 300 lbf-ft. The LO2 tank features a bottom dome drain system and is equipped with sloshing baffles. The remaining LO2 in the tank slowly forms a liquid column along the centerline of tank under the zero gravity environments. The radial force on the LO2 tank wall is predicted less than 100 lbf. The radial moment calculated based on the center of gravity of the vehicle is predicted as high as 4500 lbf-ft just before MECO and dropped down to near zero after propellant draining stopped completely.

Kim, Sura↗

Wave Amplitude Dependent Engineering Model of Propellant Slosh in Spherical Tanks

Liquid propellant slosh is often a concern for the controllability of flight vehicles. Anti-slosh devices are traditionally included in propellant tank designs to limit the amount of sloshing allowed during flight. These devices and any necessary supports can be quite heavy to meet various structural requirements. Some of the burden on anti-slosh devices can be relieved by exploiting the nonlinear behavior of slosh waves in bare smooth wall tanks. A nonlinear regime slosh model for bare spherical tanks was developed through a joint analytical and experimental effort by NASA/MSFC. The developed slosh model accounts for the large damping inherent in nonlinear slosh waves which is more accurate and drives conservatism from vehicle stability analyses that use traditional bare tank slosh models. A more accurate slosh model will result in more realistic predicted slosh forces during flight reducing or removing the need for active controls during a maneuver or baffles in the tank design. Lower control gains and smaller or fewer tank baffles can reduce cost and system complexity while increasing vehicle performance. Both Computational Fluid Dynamics (CFD) simulation and slosh testing of three different spherical tank geometries were performed to develop the proposed slosh model. Several important findings were made during this effort in addition to determining the parameters to the nonlinear regime slosh model. The linear regime slosh damping trend for spherical tanks reported in NASA SP-106 was shown to be inaccurate for certain regions of a tank. Additionally, transition to the nonlinear regime for spherical tanks was only found to occur at very large wave amplitudes in the lower hemisphere and was a strong function of the propellant fill level in the upper hemisphere. The nonlinear regime damping trend was also found to be a function of the propellant fill level.

Brodnick, Jacob↗

Numerical Modeling of No Vent Filling of a Cryogenic Tank with Thermo-dynamic Vent System Assisted Injector

This paper presents a multi-node finite volume model of No Vent Filling (NVF) of a cryogenic tank with Thermo-dynamic Vent System (TVS) assisted injector, using the Generalized Fluid System Simulation Program (GFSSP), a general purpose flow network code. NVF tests were conducted in a CRYOgenic Orbital Testbed (CRYOTE) tank which was filled by liquid nitrogen using a TVS assisted injector with vent valve closed during the entire filling process. In TVS assisted injector, the liquid flow splits into two streams: one stream is routed to a Joule-Thomson (J-T) orifice where the flow immediately flashes from liquid to vapor or two phase mixture because the downstream to J-T leg is maintained at vacuum level.; the other stream is injected into the tank after being cooled by cold vapor of J-T leg in a heat exchanger. The flow through J-T leg is also used to cool the outer metal matrix of the injector which in turn cools the vapor in the tank ullage. The cooling of vapor in the ullage by cold injector surface reduces ullage pressure that allows liquid to enter and fill the tank. An integrated numerical model of the test set up was developed. The model included the dual lines of TVS assisted injector, tank and tank wall. The tank was discretized into multiple fluid nodes and branches to represent the ullage and liquid nitrogen and multiple solid nodes to represent the tank wall and structure. The heat transfer between solid to fluid was calculated from pool boiling correlations which include film, transition, and nucleate boiling, as well as natural convection during pre- and post-boiling. The model also accounts for the condensation of vapor at ullage-injector interface and when it comes in contact with the liquid spray. The predicted pressure, resident mass, wall temperature in the tank were compared with the test data.

Alok Majumdar↗

Compatibility of the Radio Frequency Mass Gauge with Graphite-Epoxy Composite Tanks

The radio frequency mass gauge (RFMG) is a low-gravity propellant quantity gauge being developed at NASA for possible use in long-duration space missions utilizing cryogenic propellants. As part of the RFMG technology development process, we evaluated the compatibility of the RFMG with a graphite-epoxy composite material used to construct propellant tanks. The key material property that can affect compatibility with the RFMG is the electrical conductivity. Using samples of 8552/IM7 graphite-epoxy composite, we characterized the resistivity and reflectivity over a range of frequencies. An RF impedance analyzer was used to characterize the out-of-plane electrical properties (along the sample thickness) in the frequency range 10 to 1800 MHZ. The resistivity value at 500 MHz was 4.8 ohm-cm. Microwave waveguide measurements of samples in the range 1.7 - 2.6 GHz, performed by inserting the samples into a WR-430 waveguide, showed reflectivity values above 98%. Together, these results suggested that a tank constructed from graphite/epoxy composite would produce good quality electromagnetic tank modes, which is needed for the RFMG. This was verified by room-temperature measurements of the electromagnetic modes of a 2.4 m diameter tank constructed by Boeing from similar graphite-epoxy composite material. The quality factor Q of the tank electromagnetic modes, measured via RF reflection measurements from an antenna mounted in the tank, was typically in the range 400 less than Q less than 3000. The good quality modes observed in the tank indicate that the RFMG is compatible with graphite-epoxy tanks, and thus the RFMG could be used as a low-gravity propellant quantity gauge in such tanks filled with cryogenic propellants.

Propellant tanks↗

Apollo 13 Mission: Cryogenic Oxygen Tank 2 Anomaly Report

There were two investigative aspects associated with the loss of the cryogenic oxygen tank pressure during the Apollo 13 flight. First, what was the cause of the flight failure of cryogenic oxygen tank 2. Second, what possible contributing factors during the ground history of the tank could have led to the ultimate failure in flight. The first flight indication of a problem occurred when the quantity measurement in the tank went full scale about 9 hours before the incident. This condition in itself could not have contributed to ignition in the tank, since the energy in the circuit is restricted to about 7 milli-joules. Data from the electrical system provided the second indication of a problem when the fans in tank 2 were activated to reduce any stratification which might have been present in the supercritical oxygen in the tank. Several short-circuits were detected and have been isolated to the fan circuits of tank 2. The first short-circuit could have contained as much as 160 joules of energy, which is within the current-protection level of the fan circuits. Tests have shown that two orders of magnitude less energy than this is sufficient to ignite the polytetrafluoroethylene insulation on the fan circuits in the tank. Consequently, the evidence indicates that the insulation on the fan wiring was ignited by the energy in the short-circuit.

Source record↗

Filament wound metal lined propellant tanks for future Earth-to-orbit transports

For future Earth-to-orbit transport vehicles, reusability and lighter weights are sought for the main propellant tanks. To achieve this, a filament wound tank with a metal liner and an intermediate layer of foam-filled honeycomb is proposed. A hydrogen tank is used as an example. To accommodate mismatches in the expansion of liner and overwrap a design is proposed wherin the liner is configured so that the extension of the liner under pressure matches the expected contraction of the same liner due to the presence of a cryogen. In operation, the liner is pressurized at a rate such that the pressure strain matches the contraction due to decrease in temperature. As an alternate approach, compressive pre-stress is placed in the liner such that it will not separate from the overwrap. A finite element program is used to show stresses in the liner and overwrap for various tank pressures for the pre-stressed liner concept. A fracture mechanics analysis is made of the liners to determine tank life. The tank concept shown has a similar weight to the Shuttle external hydrogen tank, but the filament wound tank is expected to be reusable. Integration of the propellant tanks into a future transport vehicle is discussed.

Macconochie, Ian O.↗

Thermal-fluid analysis of the fill and drain operations of a cryrogenic fuel tank

The Generic Research Cryogenic Tank was designed to establish techniques for testing and analyzing the behavior of reusable fuel tank structures subjected to cryogenic fuels and aerodynamic heating. The Generic Research Cryogenic Tank tests will consist of filling a pressure vessel to a prescribed fill level, waiting for steady-state conditions, then draining the liquid while heating the external surface to simulate the thermal environment associated with hypersonic flight. Initial tests of the Generic Research Cryogenic Tank will use liquid nitrogen with future tests requiring liquid hydrogen. Two-dimensional finite-difference thermal-fluid models were developed for analyzing the behavior of the Generic Research Cryogenic Tank during fill and drain operations. The development and results of the two-dimensional fill and drain models, using liquid nitrogen, are provided, along with results and discussion on extrapolating the model results to the operation of the full-size Generic Research Cryogenic Tank. These numerical models provided a means to predict the behavior of the Generic Research Cryogenic Tank during testing and to define the requirements for the Generic Research Cryogenic Tank support systems such as vent, drain, pressurization, and instrumentation systems. In addition, the fill model provided insight into the unexpected role of circumferential conduction in cooling the Generic Research Cryogenic Tank pressure vessel during fill operations.

Stephens, Craig A.↗

Cryogenic Storage Tank Non-Destructive Evaluation

This slide presentation reviews the work in non-destructive evaluation (NDE) of cryogenic storage tanks. Four large cryogenic tanks, constructed in 1965 with perlite insulation in the annular regions, are of concern. The construction of the tanks, two Liquid Oxygen (LOX) and two Liquid Hydrogen (LH2), are described. The loss rate for the LOX tank at Pad A is slightly higher than that for the one at Pad B. The concerns for the LH2 tank at Pad B are that there is a significantly higher boil-off rate than that at Pad A, that there is mold growth, indicative of increased heat flow, that there is a long down-time needed for repairs, and that 3 of 5 full thermal cycles have been used on the Pad B LH2 tank. The advantages and disadvantages of thermal imaging are given. A detailed description of what is visible of the structures in the infra-red is given and views of the thermal images are included. Missing Perlite is given as the probable cause of the cold spot on the Pad B LH2 tank. There is no indications of problematic cold regions on the Pad A LH2 tank, as shown by the thermal images given in the presentation. There is definite indication of a cold region on the Pad A LOX tank. There is however concerns with thermal imaging, as thermal images can be significantly effected by environmental conditions, image differences on similar days but with different wind speeds. Other effects that must be considered include ambient temperature, humidity levels/dew, and cloud reflections

Arens, Ellen↗

Developing NDE Techniques for Large Cryogenic Tanks

The Shuttle Program requires very large cryogenic ground storage tanks in which to store liquid oxygen and hydrogen. The existing Pads A and B Launch Complex-39 tanks, which will be passed onto future launch programs, are 45 years old and have received minimal refurbishment and only external inspections over the years. The majority of the structure is inaccessible without a full system drain of cryogenic liquid and granular insulation in the annular region. It was previously thought that there was a limit to the number of temperature cycles that the tanks could handle due to possible insulation compaction before undergoing a costly and time consuming complete overhaul; therefore the tanks were not drained and performance issues with these tanks, specifically the Pad B liquid hydrogen tank, were accepted. There is a needind an opportunity, as the Shuttle program ends and work to upgrade the launch pads progresses, to develop innovative non-destructive evaluation (NDE) techniques to analyze the current tanks. Techniques are desired that can aid in determining the extent of refurbishment required to keep the tanks in service for another 20+ years. A nondestructive technique would also be a significant aid in acceptance testing of new and refurbished tanks, saving significant time and money, if corrective actions can be taken before cryogen is introduced to the systems.

Parker, Don↗