Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Synchrotrons”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Probing the Mechanism of Selective Phosphate Adsorption from Wastewater Using Aqueous and Synchrotron X-ray Characterization

Ion exchange shows promise for recovering phosphate from wastewater as value-added products, but requires high phosphate selectivity to compete with conventional treatment. Hybrid anion exchange (HAIX) resins, which contain non-selective basic functional groups and selective iron oxide nanoparticles (FeOnp), can effectively remove phosphate from wastewater. However, knowledge gaps remain regarding the mechanisms of phosphate selectivity and influence of competing ions, hindering needed efforts to model adsorption dynamics and design scalable adsorption processes for varying wastewaters. To address these gaps, we integrated aqueous-phase adsorption analysis with solid-phase, synchrotron-based X-ray characterization; this integration facilitated elucidation of the distribution and speciation of iron, phosphate, and competing anions on HAIX resins. We compared a quaternary ammonium-functionalized HAIX resin (SBA) to a tertiary amine version (WBA) to determine the role of functional groups. X-ray radiography revealed differences in FeOnp speciation (goethite vs. ferrihydrite) and distribution (peripheral vs. homogeneous) between the resins, resulting in varied phosphate affinity and intraparticle diffusion resistance. Using micro-X-ray fluorescence (μ-XRF) and micro-X-ray absorption near-edge structure (μ-XANES) spectroscopy, we identified differences in where and how phosphate binds across resin types and wastewaters. Across wastewater compositions, FeOnp sites in WBA contribute more to phosphate adsorption than in SBA, possibly due to variations in Fe distribution and speciation. Phosphate adsorption densities calculated from quantitative μ-XRF maps matched those from aqueous analysis, demonstrating the effectiveness of this integrated approach. Altogether, results demonstrate the use of synchrotron-based X-ray characterization for investigating adsorption mechanisms and advance HAIX as a phosphate recovery technology from complex wastewaters.

Nutrient recovery↗

Development of an operando characterization stage for multi-modal synchrotron x-ray experiments

It is widely accepted that micro- and nanoscale inhomogeneities govern the performance of many thin-film solar cell absorbers. These inhomogeneities yield material properties (e.g., composition, structure, and charge collection) that are challenging to correlate across length scales and measurement modalities. The challenge is compounded if a correlation is sought during device operation or in conditions that mimic aging under particular stressors (e.g., heat and electrical bias). Correlative approaches, particularly those based on synchrotron x-ray sources, are powerful since they can access several material properties in different modes (e.g., fluorescence, diffraction, and absorption) with minimal sample preparation. Small-scale laboratory x-ray instruments have begun to offer multi-modality but are typically limited by low x-ray photon flux, low spatial resolution, or specific sample sizes. To overcome these limitations, a characterization stage was developed to enable multi-scale, multi-modal operando measurements of industrially relevant photovoltaic devices. The stage offers compatibility across synchrotron x-ray facilities, enabling correlation between nanoscale x-ray fluorescence microscopy, microscale x-ray diffraction microscopy, and x-ray beam induced current microscopy, among others. Furthermore, the stage can accommodate device sizes up to 25 × 25 mm 2 , offering access to multiple regions of interest and increasing the statistical significance of correlated properties. The stage materials can sustain humid and non-oxidizing atmospheres, and temperature ranges encountered by photovoltaic devices in operational environments (e.g., from 25 to 100 °C). As a case study, we discuss the functionality of the stage by studying Se-alloyed CdTe photovoltaic devices aged in the stage between 25 and 100 °C.

14 SOLAR ENERGY↗

Runaway electron plateau current profile reconstruction from synchrotron imaging and Ar-II line polarization angle measurements in DIII-D

Abstract Current profile reconstructions are obtained for high current ( I p ≃ 550 kA) post-disruption runaway electron (RE) plateau plasmas in DIII-D. Two novel methods of measuring the RE current profile in high-current RE plateaus are introduced and compared: localization of the q = 2 rational surface using visible synchrotron emission (SE) imaging and the measurement of the polarization angle of line-integrated Ar-II line emission. The two methods are found to be consistent with each other within the data uncertainties. Different simulations of the RE current profile are compared with the measurements: the toroidal fluid RE model is found to best fit the data, within the measurement uncertainties. In addition to introducing two novel methods to measure the RE current profile and validating present simulation capabilities, this work demonstrates that instabilities can grow at q = 2 and q = 1 surfaces without necessarily causing a RE final loss instability. Numerical simulations are also presented to elucidate the role of these instabilities on synchrotron emission.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantitative analysis of dislocations in 4H-SiC wafers using synchrotron X-ray topography with ultra-high angular resolution

Utilization of an Si(331) beam conditioner together with an Si(111) double-crystal monochromator (DCM) enables the angular resolution of synchrotron X-ray topography to be increased by an order of magnitude compared with grazing-incidence topography or back-reflection topography conducted with the DCM alone. This improved technique with extremely small beam divergence is referred to as synchrotron X-ray plane-wave topography (SXPWT). This study demonstrates that the rocking curve width of 4H-SiC 0008 in PWT is only 2.5" and thus the lattice distortion at the scale of 1" will significantly affect the diffracted intensity. This work reports the ultra-high angular resolution in SXPWT which enables detailed probing of the lattice distortion outside the dislocation core in 4H-SiC, where the sign of the Burgers vector can be readily determined through comparison with ray-tracing simulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Residual strain orientation in rolled titanium determined with synchrotron X-ray Laue microdiffraction

Previously, synchrotron X-ray Laue microdiffraction has been used to measure the magnitudes of residual strain in materials. Recently the method was advanced to determine the orientation of the strain ellipsoid and applied to naturally deformed quartzites; however, the deformation history of these quartzites is ambiguous due to their natural origin. Here, in this study, synchrotron X-ray Laue microdiffraction (µXRD) is used to measure the residual strain for the first time in a sample with known stress history, rolled titanium. A deviatoric strain tensor is calculated from each Laue diffraction image collected with two µXRD scans of a rolled titanium sheet in different sample orientations. The principal strain axes are calculated using an eigen decomposition of the deviatoric strain tensors. The results show that the principal axis of compression is aligned with the normal direction of the titanium sheet, and the principal axis of extension is aligned with the rolling direction. Pole figures are used to represent the 3D distribution of residual strain axes.

36 MATERIALS SCIENCE↗

Ultimate brightness of a medium-energy synchrotron light source at operational beam intensity

Synchrotron light sources are key instruments of modern science, providing unique opportunities for groundbreaking studies in diverse scientific disciplines and driving innovation in numerous scientific and technological fields. Fourth-generation light sources provide unprecedented capabilities in imaging, spectroscopy and diffraction techniques. Ultimate brightness is the key to advancing to a smaller scale, faster response, and higher data measurement and processing rate. The brightness is primarily determined by the electron beam emittance and energy spread at operational intensity. A common feature of fourth-generation synchrotrons is the short length of the electron bunches combined with a very small transverse beam size. Consequently, the high particle density leads to strong collective effects that significantly increase the emittance and limit the achievable brightness at operational beam intensity. In this article, we summarize our studies of the emittance and brightness scaled with the beam energy and intensity, taking into account the effects of intrabeam scattering, beam-impedance interaction and bunch lengthening provided by higher-harmonic RF systems to identify optimal combinations of machine and beam parameters.

36 MATERIALS SCIENCE↗

High-resolution in-beam video rate imaging with the ClearXCam for synchrotron beamlines

The ClearXCam detector is a new video rate imaging in-beam monitor based on a diamond sensor. Imaging with 2304 effective pixels is achieved by sequentially biasing one of 48 metal stripes on one side of a diamond sensor, while reading out the current from 48 stripes on the other side of the sensor. This system was characterized for real-time X-ray beam diagnostics at synchrotron beam­line 17-BM at the National Synchrotron Light Source II. Significant results include: detection of in-beam structure via the imaging mode, beam focusing in one minute with real-time imaging feedback during a focusing event, linearity over five orders of magnitude, validation of a fast mode operating at 100 Hz, and sub-micron beam-positioning resolution. The system is now available commercially.

36 MATERIALS SCIENCE↗

Understanding High-Voltage Behavior of Sodium-Ion Battery Cathode Materials Using Synchrotron X-ray and Neutron Techniques: A Review

Despite substantial research efforts in developing high-voltage sodium-ion batteries (SIBs) as high-energy-density alternatives to complement lithium-ion-based energy storage technologies, the lifetime of high-voltage SIBs is still associated with many fundamental scientific questions. In particular, the structure phase transition, oxygen loss, and cathode–electrolyte interphase (CEI) decay are intensely discussed in the field. Synchrotron X-ray and neutron scattering characterization techniques offer unique capabilities for investigating the complex structure and dynamics of high-voltage cathode behavior. In this review, to accelerate the development of stable high-voltage SIBs, we provide a comprehensive and thorough overview of the use of synchrotron X-ray and neutron scattering in studying SIB cathode materials with an emphasis on high-voltage layered transition metal oxide cathodes. We then discuss these characterizations in relation to polyanion-type cathodes, Prussian blue analogues, and organic cathode materials. Finally, future directions of these techniques in high-voltage SIB research are proposed, including CEI studies for polyanion-type cathodes and the extension of neutron scattering techniques, as well as the integration of morphology and phase characterizations.

25 ENERGY STORAGE↗

Synchrotron-driven Instabilities in Relativistic Plasmas of Arbitrary Opacity

Recent work has shown that synchrotron emission from relativistic plasmas leads the electron distribution to form an anisotropic ring in momentum space, which can be unstable to both kinetic and hydrodynamic instabilities. Fundamental to these works was the assumption that the plasma was optically thin, allowing all emitted radiation to escape. Here, we examine the behavior of these instabilities as the plasma becomes more optically thick. To do this, we extend a recently developed Fokker–Planck operator for synchrotron emission and absorption in mildly relativistic plasmas to ultrarelativistic plasmas. For a given set of plasma parameters, photons emitted by higher-energy electrons tend to be higher frequency, and thus more easily escape the plasma. As a result, the ratio of the photon emission rate (radiative drag) to absorption rate (radiative diffusion) for a given electron is extremely energy dependent. Given this behavior, we determine the critical parameters that control the opacity, and show how the plasma gradually transitions to become more isotropic and stable at higher opacity.

79 ASTRONOMY AND ASTROPHYSICS↗

Image processing workflow yielding high contrast synchrotron nanoscale computed tomography data from Ni-YSZ electrodes

The operating lifetime of Ni-YSZ fuel electrodes used in solid oxide electrolysis cells and fuel cells (SOECs and SOFCs) is limited by Ni redistribution, one of the primary degradation mechanisms that must be overcome to extend the longevity and maximize the performance of SOECs and SOFCs. To achieve this, 3D microstructural data is needed to relate both initial performance and performance loss over time to microstructural properties and their evolution throughout operation under various conditions. However, 3D microstructure data remains relatively scarce within the literature due to multiple challenges in acquiring and analyzing such data reliably. This work presents a workflow for acquiring and processing synchrotron X-ray nanoscale computed tomography (nano-CT) data from Ni-YSZ electrodes. Parameters for each step in the nano-CT workflow are described up to the final result (a 3D reconstruction), with particular emphasis on image alignment using freely available software. Following the results of a parametric sweep of the image alignment step, high contrast, low signal-to-noise 3D nano-CT data is obtained with relatively short compute times. While the exact methods best suited to samples with different microstructural qualities, or similar Ni-YSZ nano-CT data obtained from other sources may deviate from the solution found herein, this work also generalizes the decision points and evaluation of each step to provide a starting point to adapt this workflow to other datasets.

08 HYDROGEN↗

Synchrotron X‐Ray‐Driven Nitrogen Reduction on an AgCu Thin Film

Abstract Nitrogen (N 2 ) is an essential element for life, but kinetically stable N 2 in the atmosphere needs to be reduced to biologically available forms as a nutrient for organisms. Abiotic nitrogen fixation is critical to the origin of life on the early Earth, which is due to lightning or mineral‐based reduction. Here, synchrotron X‐ray‐induced silver nitrate formation on a silver copper (AgCu) thin‐film is reported. Time‐resolved X‐ray diffraction measurements show that under intense X‐ray exposure, initially formed silver oxides (AgOx) are quickly converted to silver nitrate (AgNO 3 ). Interestingly, AgNO 3 is first formed in its high‐temperature phase with a space group of R3cH , which gradually transforms to the room temperature phase with a space group of Pbca under continuous X‐ray irradiation. The result not only provides a new clue about the abiotic nitrogen reduction prior to life but also demonstrates a novel strategy of materials synthesis using synchrotron X‐rays.

Hui, Jian↗

Effect of oxidation on the release of multiple metals from industrially polluted sediments and synchrotron-based evidence of Cu–S dynamic association

Disposal operations for industrially polluted sediments are usually accompanied by disturbance and resuspension, which can induce metal remobilization and secondary pollution. Evaluating the risk of metal release under various redox conditions is fundamental for predicting contaminant mobilization and guiding remediation measures. An abandoned oxidation pond, Yanjia Lake, China, was selected as a typical industrially polluted site. Re-suspension experiments were carried out by mixing polluted sediments with lake water under oxic or anoxic conditions, then investigating the effect of oxidation conditions on the release of multiple metals. Metal concentrations and aqueous chemistry in the overlying water were monitored. Synchrotron-based methods, including X-ray absorption near-edge structure (XANES) and extended X-ray absorption fine structure (EXAFS), were used to characterize oxidation states and coordination conditions of metals in sediments. The release of metals, including Cr, Co, Ni, Cu, Zn, Se, Mo, Sn, Cd, and Pb, was enhanced under oxic vs. anoxic conditions. The XANES analysis revealed that elevated Cr and Zn concentrations under oxic conditions likely resulted from the oxidation of Cr(III) and oxidizing dissolution of ZnS, respectively. K-edge Cu XANES, S XANES, and Cu EXAFS analyses reconstructed the Cu–S association, indicating that S-related oxidation promoted Cu release and Cu–O partly replaced Cu–S in the sediment after a 7-day oxic treatment. The release of most metals was promoted under oxic conditions, resulting from the oxidation of sulfides and metals as indicated by aqueous and synchrotron-based evidence. The risk of secondary pollution is greatly enhanced under oxic conditions, which suggests that measures should be taken to minimize the redox disturbance during sediment remediation. This information can guide the management of sediments in Yanjia Lake and other contaminated sites with similar properties.

54 ENVIRONMENTAL SCIENCES↗

Synchrotron X-ray based particle image velocimetry to measure multiphase streamflow and densitometry

Synchrotron-based radiation techniques are increasingly used in the field of flow condition measurements. As a complicated multiphase flow, cavitation has been investigated in a wide variety of industrial fields, to prevent damages on spillways at large dams or intensify the bacteria eradication rate during water treatments. To control the detrimental effects of cavitating flows, the dynamics of and mechanisms affecting cavitation development shall be visualized and identified in real-time. Due to the large reflection and scattering effects of multiphase flow, standard visible-light imaging technologies cannot penetrate vapor bubbles and provide extremely limited information. In this study, the synchrotron source emitted high-flux X-ray pulses are used to capture flow motion and visualize internal structures with sufficiently high spatial and temporal resolutions. The image processing procedures on raw x-ray images are developed using 2D Fourier transform (FT) and wavelet transform (WT) to implement the contrast enhancement and de-noising. Through the edge detection algorithm, tracking either seeded particles or phase interfaces inside the opaque multiphase flow can be achieved to perform the particle image velocimetry. Further, with decomposing particle-only and particle-eliminated subplots from the X-ray phase-contrast image, the time-resolved velocity and void fraction fields are obtained simultaneously, paving a way for further flow condition analysis such as densitometry.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Asymmetric Rowland circle geometries for spherically bent crystal analyzers in laboratory and synchrotron applications

Spherically bent crystal analyzers (SBCAs) are the dominant high-resolution hard X-ray optic in the ongoing rebirth of laboratory-based X-ray absorption fine structure (XAFS) and X-ray emission spectroscopy (XES) as well as in synchrotron methods such as high energy resolution fluorescence detection (HERFD) and non-resonant X-ray Raman scattering (XRS). In the overwhelming majority of cases, SBCAs are implemented in a ‘symmetric’ configuration on the Rowland circle, wherein the diffracting crystal plane is nominally coincident with the analyzer surface. We report here comprehensive investigations of ‘asymmetric’ operation of SBCA on the Rowland circle, wherein the diffracting crystal plane is not coincident with the optical surface of the analyzer. First, we have developed a laboratory spectrometer for XAFS and XES that is specialized for asymmetric SBCA operation. Here we find several benefits, including the capacity to use a single SBCA over a very wide energy range via ‘hkl hopping’ and the frequent ability to eliminate Johann error, the most prevalent energy-broadening mechanism when using SBCA symmetrically on the Rowland circle. Second, we expand these ideas to synchrotron facilities with a demonstration study of HERFD and XRS where asymmetric operation also provided advantage. Our results suggest that large-array systems for HERFD augmented with an additional mechanical degree of freedom could streamline user operation and also indicate benefits to XRS in the asymmetric configuration, where larger solid angle, larger sample-to-detector distance, and decreased Johann error can be achieved simultaneously.

47 OTHER INSTRUMENTATION↗

A new μ -high energy resolution fluorescence detection microprobe imaging spectrometer at the Stanford Synchrotron Radiation Lightsource beamline 6-2

In this report we describe a new synchrotron X-ray Fluorescence (XRF) imaging instrument with an integrated High Energy Fluorescence Detection X-ray Absorption Spectroscopy (HERFD-XAS) spectrometer at the Stanford Synchrotron Radiation Lightsource at beamline 6-2. The X-ray beam size on the sample can be defined via a range of pinhole apertures or focusing optics. XRF imaging is performed using a continuous rapid scan system with sample stages covering a travel range of 250 × 200 mm 2 , allowing for multiple samples and/or large samples to be mounted. The HERFD spectrometer is a Johann-type with seven spherically bent 100 mm diameter crystals arranged on intersecting Rowland circles of 1 m diameter with a total solid angle of about 0.44% of 4π sr. A wide range of emission lines can be studied with the available Bragg angle range of ~64.5°–82.6°. With this instrument, elements in a sample can be rapidly mapped via XRF and then selected features targeted for HERFD-XAS analysis. Furthermore, utilizing the higher spectral resolution of HERFD for XRF imaging provides better separation of interfering emission lines, and it can be used to select a much narrower emission bandwidth, resulting in increased image contrast for imaging specific element species, i.e., sparse excitation energy XAS imaging. This combination of features and characteristics provides a highly adaptable and valuable tool in the study of a wide range of materials.

47 OTHER INSTRUMENTATION↗

Photoelectron spectroscopy of CsK2Sb photocathode at Synchrotron Radiation Facility using vacuum transport system

As accelerators and electron microscopes become more advanced, high-performance photocathodes are required. In particular, Cesium potassium antimonide (CsK 2 Sb) photocathode is of interest because of its low emittance, excitability in visible light, and high quantum efficiency (QE). The challenge is its high susceptibility to environment that lead to low operating vacuum pressure and short lifetime/low extraction charge. To resolve these issues, it is necessary to understand the molecular structure of the cathode and its degradation mechanism. In this study, we transported CsK 2 Sb photocathode to a beamline of synchrotron radiation facility using a vacuum transport system for molecular structure analysis. Specifically, the cathode was deposited in an evaporation system at Nagoya University. We transported it to Aichi Synchrotron Radiation Center (Aichi SR) located 15 km away, and analyzed it in the depth direction by X-ray photoelectron spectroscopy (XPS) at BL7U. Based on the results, we quantitatively evaluated the composition ratios and stoichiometry of the cathode elements (Sb, K, Cs). A Cs ex-cess state of surface was observed at the surface, and it is consistent with previous studies. The intended atomic structure of CsK 2 Sb was formed only at a few nanometres of the surface on the Mo substrate. On the other hand, the CsK 2 Sb cathode structure on the graphene substrate was preserved further in the depth direction.

47 OTHER INSTRUMENTATION↗

Rotating synchrotron radiation: Photon emission from magnetized and rotating quark-gluon plasma

This paper investigates the production of nonprompt photons originating from rotating synchrotron radiation (RoSyRa), specifically the emission of photons by a rigidly rotating quark-gluon plasma in thermal equilibrium, in the presence of an external magnetic field. We compute the nonprompt photon spectrum and its elliptic flow (𝑣 2 ) at midrapidity. In particular, we investigate the finite-volume effects. We find that at low transverse momentum, the magnetic field induces a significant 𝑣 2 , while the plasma rotation boosts the synchrotron radiation of negatively charged quarks. These findings make RoSyRa a viable candidate mechanism to resolve the “direct photon puzzle.”

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Structure refinement and anisotropic atomic displacement parameters of 1M Illite: Rietveld and pair distribution function analysis using synchrotron X-ray radiation

Illite, a widespread clay mineral, plays a pivotal role in geological processes, notably as an indicator in diagenetic and hydrothermal alteration environments, and possesses significant industrial relevance in applications including ceramics, construction and catalysis. However, challenges including its nanoscale crystallinity, structural disorder and frequent interstratification with other clay minerals have hindered detailed structural characterization using conventional X-ray diffraction (XRD) techniques. This study employs integrated synchrotron XRD and pair distribution function (PDF) analysis to elucidate the crystal structure of the 1M illite polytype, yielding the first determination of its anisotropic atomic displacement parameters (U aniso ). TheseU aniso parameters provide critical insights into atomic dynamics and static disorder within the structure, enabling a more refined understanding of structure–property relationships. This integrated approach, combining synchrotron XRD, Rietveld refinement and PDF analysis, yields a comprehensive structural characterization, capturing both average crystallographic and local atomic arrangements. Considering illite's widespread geological occurrence and industrial importance, this high-precision structural dataset, especially the determinedU aniso values, provides a crucial benchmark for future modeling and simulation efforts targeting accurate prediction of its physicochemical behavior.

Chemistry↗