Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Study center”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Evaluation of Angiographic and Technical Aspects of Carotid Stenting with Diffusion-Weighted Magnetic Resonance Imaging

The detection of clinically silent ischemic lesions on postprocedural diffusion-weighted magnetic resonance images has become a preferred method for the description of embolic risks. The purpose of this single-center study was to evaluate whether diffusion-weighted imaging (DWI) could determine material related or technical risk factors of filter-protected carotid stenting. Eighty-four patients with symptomatic severe ({>=}60%) carotid artery stenoses received filter-protected carotid stenting. Standard DWI (b = 1000) was performed within 48 h before and after carotid stenting. The occurrence and load of new postinterventional DWI lesions were assessed. Multivariate analysis was performed to determine risk factors associated with DWI lesions, with emphasis on technical factors such as use of different access devices (guiding catheter method vs. long carotid sheath method), type of stent (open-cell nitinol stent vs. closed-cell Wallstent), and protective device (filters with 80-{mu}m vs. 110-120-{mu}m pore size). Markers for generalized atherosclerosis and for degree and site of stenosis were assessed to allow comparison of adequate risk profiles. Access, protective device, and stent type were not significantly associated with new embolic DWI lesions when we compared patients with equivalent risk profiles (long carotid sheath method 48% [11 of 23] vs. guiding catheter method 44% [27 of 61], Wallstent 47% [15 of 32] vs. nitinol stent 44% [23 of 52], and small pore size filter 61% [11 of 18] vs. large pore size filter 41% [27 of 66]). Single-center DWI studies with a moderate number of cases are inadequate for proper assessment of the embolic risk of technical- or material-related risk factors in carotid stenting. Larger multicenter studies with more cases are needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A static data flow simulation study at Ames Research Center

Demands in computational power, particularly in the area of computational fluid dynamics (CFD), led NASA Ames Research Center to study advanced computer architectures. One architecture being studied is the static data flow architecture based on research done by Jack B. Dennis at MIT. To improve understanding of this architecture, a static data flow simulator, written in Pascal, has been implemented for use on a Cray X-MP/48. A matrix multiply and a two-dimensional fast Fourier transform (FFT), two algorithms used in CFD work at Ames, have been run on the simulator. Execution times can vary by a factor of more than 2 depending on the partitioning method used to assign instructions to processing elements. Service time for matching tokens has proved to be a major bottleneck. Loop control and array address calculation overhead can double the execution time. The best sustained MFLOPS rates were less than 50% of the maximum capability of the machine.

Barszcz, Eric↗

The Center for the Study of Terrestrial and Extraterrestrial Atmospheres (CSTEA)

The Center for the Study of Terrestrial and Extraterrestrial Atmospheres (CSTEA) was established in 1992. The center began with 14 active Principal Investigators (PI's). The research of the Center's PIs has, for the most part, continued in the same four areas as presented in the original proposal: Remote Sensing, Atmospheric Chemistry, Sensors and Detectors, and Spacecraft Dynamics.

Thorpe, Arthur N.↗

Demand Response and Open Automated Demand Response Opportunities for Data Centers

This study examines data center characteristics, loads, control systems, and technologies to identify demand response (DR) and automated DR (Open Auto-DR) opportunities and challenges. The study was performed in collaboration with technology experts, industrial partners, and data center facility managers and existing research on commercial and industrial DR was collected and analyzed. The results suggest that data centers, with significant and rapidly growing energy use, have significant DR potential. Because data centers are highly automated, they are excellent candidates for Open Auto-DR. 'Non-mission-critical' data centers are the most likely candidates for early adoption of DR. Data center site infrastructure DR strategies have been well studied for other commercial buildings; however, DR strategies for information technology (IT) infrastructure have not been studied extensively. The largest opportunity for DR or load reduction in data centers is in the use of virtualization to reduce IT equipment energy use, which correspondingly reduces facility cooling loads. DR strategies could also be deployed for data center lighting, and heating, ventilation, and air conditioning. Additional studies and demonstrations are needed to quantify benefits to data centers of participating in DR and to address concerns about DR's possible impact on data center performance or quality of service and equipment life span.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Treating Epiphora in Adults With the Wilhelm Plastic Nasolacrimal Stent: Mid-Term Results of a Prospective Study

The objective of the present study was to evaluate, in a prospective, single-center study, the effectiveness of the Wilhelm-type stent used in interventional radiology for the management of epiphora. Patients (n = 104; mean age 64 [range 25-88]; 33 male and 71 female) with severe epiphora had the stents inserted (135 stents in 115 eyes) to treat obstruction of the nasolacrimal system. The etiology of the obstruction was idiopathic in 83 cases, chronic dacryocystitis in 31, cases and postsurgical status in 1 case. The overall technical success rate of stent placement was near 94%. Resolution of epiphora was complete in 105 cases and partial in 3 cases. During a mean 13-month follow-up (range 1 week to 28 months), the median duration of primary patency was 11 months, and the percentage of patency at 6 months was 60.8%, at 1 year was 39.6%, and at 2 years was 25%. Stents malfunctioned in 54 cases, and all were easily withdrawn except in 1 case. Of these 27 cases, patency recovered spontaneously in 9 and by way of a second stent in 18. Secondary patency was 50%. Factors presdisposing to lower primary patency are inflammatory etiology and location of the obstruction. The benefit of stent deployment is clear with respect to the resolution of epiphora in candidate patients for percutaneous treatment. Technical and/or design improvements would be welcomed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Structural Design for a Neptune Aerocapture Mission

A multi-center study was conducted in 2003 to assess the feasibility of and technology requirements for using aerocapture to insert a scientific platform into orbit around Neptune. The aerocapture technique offers a potential method of greatly reducing orbiter mass and thus total spacecraft launch mass by minimizing the required propulsion system mass. This study involved the collaborative efforts of personnel from Langley Research Center (LaRC), Johnson Space Flight Center (JSFC), Marshall Space Flight Center (MSFC), Ames Research Center (ARC), and the Jet Propulsion Laboratory (JPL). One aspect of this effort was the structural design of the full spacecraft configuration, including the ellipsled aerocapture orbiter and the in-space solar electric propulsion (SEP) module/cruise stage. This paper will discuss the functional and structural requirements for each of these components, some of the design trades leading to the final configuration, the loading environments, and the analysis methods used to ensure structural integrity. It will also highlight the design and structural challenges faced while trying to integrate all the mission requirements. Component sizes, materials, construction methods and analytical results, including masses and natural frequencies, will be presented, showing the feasibility of the resulting design for use in a Neptune aerocapture mission. Lastly, results of a post-study structural mass optimization effort on the ellipsled will be discussed, showing potential mass savings and their influence on structural strength and stiffness

Dyke, R. Eric↗

A comprehensive estimate of the static aerodynamic forces and moments of the 8 x 8 x 20 ft. cargo container

A comprehensive static aerodynamic simulation model of the 8 by 8 by 20 ft MILVAN cargo container is determined by combining the wind tunnel data from a 1972 NASA Ames Research Center study taken over the restricted domain (0 is less than or equal to phi is less than or equal to 90 degrees; 0 is less than or equal to alpha is less than or equal to 45 degrees) with extrapolation relations derived from the geometric symmetry of rectangular boxes. It is found that the aerodynamics of any attitude can be defined from the aerodynamics at an equivalent attitude in the restricted domain (0 is less than phi is less than 45 degrees; 0 is less than alpha is less than 90 degrees). However, a similar comprehensive equivalence with the domain spanned by the data is not available; in particular, about two-thirds of the domain with the absolute value of alpha is greater than 45 degrees is unrelated to the data. Nevertheless, as estimate can be defined for this region consistent with the measured or theoretical values along its boundaries and the theoretical equivalence of points within the region. These descrepancies are assumed to be due to measurement errors. Data from independent wind tunnel studies are reviewed; these are less comprehensive than the NASA Ames Research Center but show good to fair agreement with both the theory and the estimate given here.

Cicolani, Luigi↗

Center for Nonlinear Studies (CNLS) Leader Position [Slides]

The Center Director provides scientific leadership and line management of the CNLS while fostering collaborations with scientists throughout the Laboratory. The CNLS Center Director is expected to develop and lead a program to target and create cooperative long-term research programs consistent with the Laboratory’s strategic research objectives, to develop a strong working relationship with the CNLS External Advisory Committee, and to maintain effective working relationships throughout all levels of the Laboratory, government entities, academia and industry. The successful candidate will be expected to maintain an active research program while providing technical vision to nurture and support existing programs of others at the Center.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

An Overview of the Aerosol and Clouds-Convection-Precipitation Study (A-CCP) and its Relationship to the Geostationary AC-VC

The 2017 Decadal Survey (DS) highlighted Earth System Science themes, science and application questions, and several high priority objectives that have led to the inclusion of Aerosols (A) and Clouds-Convection-Precipitation (CCP) as Designated Observables (DOs) The aerosol-related science questions outlined by the DS focus on two major themes: 1) Climate Variability and Change and 2) Weather and Air Quality. The Aerosol mission observables targeted to address these major objectives may potentially contribute to three additional themes: 3) Marine and Terrestrial Ecosystems, 4) Global Hydrological Cycle, and 5) Earth Surface and Interior; this study will examine these linkages.In response to NASA's Designated Observables Guidance for Multi-Center Study Plans released on June 1, 2018, GSFC, LaRC, JPL, MSFC, GRC and ARC submitted Study Plan to the NASA Earth Science Division for the Aerosol (A) and Cloud, Convection, and Precipitation (CCP) Pre-formulation Study (A-CCP). The DS recognized the science merit in combining the A and CCP DOs for both enhancing the ability to address a number of Most Important (MI) objectives defined by the disciplinary panels and also to provide an expanded capability to address additional objectives beyond those addressed by individual DOs. The DS also identified Integrating Themes that can also be addressed through combinations of observables including potential combinations of DOs and the PoR. The combined A+CCP portion of this study will demonstrate how the combination of A and CCP observables will enhance the objectives of A and CCP individually, while providing the ability to expand the DS objectives addressed, and will closely connect to the A and CCP studies being performed in parallel. A critical element of the A-CCP observing strategy is to make extensive use of the so-called Program-of-Record (PoR). In this regard, the Geostationary Atmospheric Composition Virtual Constellation consisting of the GEMS, TEMPO and SENTINEL-4 and other relevant geostationary assets will provide a critical foundation for A-CCP. In this talk we will discuss how the A-CCP measurements contributes to air-quality and the geostationary constellation, and conversely, how the geostationary constellation helps answering fundamental A-CCP science objectives.

Da Silva, Arlindo↗

Clinically applicable 53-Gene prognostic assay predicts chemotherapy benefit in gastric cancer: A multicenter study

BACKGROUND:We previously established a 53-gene prognostic signature for overall survival (OS) of gastric cancer patients. This retrospective multi-center study aimed to develop a clinically applicable gene expression detection assay and to investigate the prognostic value of this signature. METHODS:A TCGA gastric adenocarcinoma cohort (TCGA-STAD) was used for comparing 53-gene signature with other gene signatures. A high-throughput mRNA hybridization gene expression assay was developed to quantify the expression of 53-genes in formalin-fixed paraffin-embedded tissues of 540 patients enrolled from three hospitals. 180 patents were randomly selected from two hospitals to build a prognostic prediction model based on the 53-gene signature using leave-p-out (one-third out) cross-validation method together with Cox regression and Kaplan-Meier analysis, and the model was assessed on three validation cohorts. FINDINGS:In the evaluation phase, studies based on TCGA-STAD showed that the 53-gene signature was significantly superior to other three prognostic signatures and was independent of TCGA molecular subtypes and clinical factors. For clinical validation and utility, the prognostic scores were generated using the newly developed assay, which was reliable and sensitive, in 100 sampling training sets and were significantly associated with OS in 100 sampling validation sets. The scores were significantly associated with OS in three independent and combined validation cohorts, and in patients with stages II and III/IV. The multivariate Cox regression demonstrated that the prognostic power of the score was independent of clinical factors, consistent with those findings in the TCGA dataset. Finally, patients with good prognostic scores exhibited significantly a better 5-year OS rate from adjuvant FOLFOX chemotherapy after surgery than from other chemotherapies. INTERPRETATION:The 53-gene prognostic score system is clinically applicable for predicting the OS of patients independent of clinical factors in gastric cancers, which could also be a promising predictive biomarker for FOLFOX regimen. FUNDING:Chinese National Science and Technology, National Natural Science Foundation and Natural Science Foundation of Jiangsu Province.

60 APPLIED LIFE SCIENCES↗

Final Technical Report for the SciDAC Center for the Study of Plasma Microturbulence

This final technical report for the SciDAC Center for the Study of Plasma Microturbulence documents contributions from MIT to the project over the period of the award (February 15, 2011 to February 14, 2020). This project focused on the development of neoclassical and gyrokinetic simulation capabilities relevant for the description of particle, momentum and energy transport in tokamak fusion plasmas. Extensive validation against experimental results from Alcator C-Mod and DIII-D experiments was performed. Overall areas of emphasis included gyrokinetic simulations, experiments, and observation of density gradient driven Trapped Electron Mode (TEM) turbulence relevant to burning plasmas; theory and gyrokinetic simulations of the parametric variation of the nonlinear upshift of the TEM critical density gradient; identification of a new mechanism for the isotope effect due to density gradient driven TEM turbulence; new synthetic diagnostics based on full-wave simulations which enabled unprecedented agreement between gyrokinetic simulations and measured fluctuation spectra with and without strong electron heating; development of new continuum pedestal neoclassical and turbulence codes; formulation and implementation of the first gyrokinetic exact Fokker-Planck collision operator in gyrokinetic turbulence simulations; development of new spectral approaches in velocity space for highly efficient treatments of collisions; new model collision operators implemented in the discontinuous Galerkin gyrokinetic edge turbulence code GKEYLL; and a new model and spectral code to study the interaction of ion- and electron-scale turbulence, which will serve as an efficient test-bed for multi-rate and multi-scale methods. These fundamental advances contribute to the development of a validated, predictive capability for turbulent and collisional particle, momentum and energy transport in both the core and edge of magnetically confined fusion plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Martian sedimentary deposits

The objectives are characterization of flow through outflow channels, sedimentation associated with Martian outflow systems, and documentation of Martian lakes. Over the period of the grant much, but not all, of the study centered on the Maja Valles outflow. Maja served as an example in which the effects of multiple channel routing and ponding could be studied. Maja Valles also served as the test case for calculating flow through an outflow system. Applying the lessons learned in Maja Valles and comparisons and contrast required a scrutiny of other channels.

Dehon, Rene↗

TPSAS-NF1676L-31282-DND

Several technology investments, beyond those used for robotic missions, are required to develop Mars human scale Entry, Descent, and Landing (EDL) systems. In a resource-constrained environment, studies play the critical role of identifying the most feasible technical paths and high payoff investments. One such NASA multi-directorate, multi-center study, is called the Entry, Descent and Landing Architecture Study (EDLAS). This paper presents a summary of phase two of the study conducted from October 2016 to September 2017. Study ground rules and assumptions are provided by NASA?s Human Exploration and Operations Mission Directorate (HEOMD) and include a Mars architecture and Mars surface lander payload manifests. Four unique entry technologies with the potential to deliver a specified 20 t human scale payload to the Mars surface are considered for analysis. Two of these techniques are evolutionary rigid vehicles, derived from robotic capsule missions and the space shuttle. Likewise, two revolutionary deployable vehicles are considered, the Adaptable Deployable Entry Placement Technology (ADEPT) and Hypersonic Inflatable Aerodynamic Decelerator (HIAD). This paper summarizes updates to the entry technology designs, the analysis motivation and approach, figures of merit by which the configurations are compared, and results of the analyses. Finally, findings are presented with the recommendation that two of the four configurations, one evolutionary and one revolutionary technology, continue to be studied in future human scale EDL studies.

Alicia Dwyer Cianciolo↗

Investigation of the origin of deep levels in CdTe doped with Bi

Combining optical (low temperature photoluminescence), electrical (thermoelectric effect spectroscopy), and structural (synchrotron X-ray powder diffraction) methods, the defect structure of CdTe doped with Bi was studied in crystals with dopant concentration in the range of 10{sup 17}-10{sup 19} at./cm{sup 3}. The semi-insulating state observed in crystals with low Bi concentration is assigned to the formation of a shallow donor level and a deep donor recombination center. Studying the evolution of lattice parameter with temperature, we postulate that the deep center is formed by a Te-Te dimer and their formation is explained by a tetrahedral to octahedral distortion, due to the introduction of Bi in the CdTe lattice. We also shows that this model agrees with the electrical, optical, and transport charge properties of the samples.

36 MATERIALS SCIENCE↗

Space operations center: Shuttle interaction study extension, executive summary

The Space Operations Center (SOC) is conceived as a permanent facility in low Earth orbit incorporating capabilities for space systems construction; space vehicle assembly, launching, recovery and servicing; and the servicing of co-orbiting satellites. The Shuttle Transportation System is an integral element of the SOC concept. It will transport the various elements of the SOC into space and support the assembly operation. Subsequently, it will regularly service the SOC with crew rotations, crew supplies, construction materials, construction equipment and components, space vehicle elements, and propellants and spare parts. The implications to the SOC as a consequence of the Shuttle supporting operations are analyzed. Programmatic influences associated with propellant deliveries, spacecraft servicing, and total shuttle flight operations are addressed.

Source record↗

Tissue sampling in the era of precision medicine: comparison of percutaneous biopsies performed for clinical trials or tumor genomics versus routine clinical care

Purpose: The purpose of the study was to determine if patients undergoing percutaneous biopsy for genetic profiling are undergoing more biopsies (procedures, passes per procedure), or experiencing more procedure-related complications. Methods: 60 patients undergoing biopsy procedures for genetic profiling were retrospectively compared with 60 consecutive control patients undergoing routine biopsies. Procedural details and related complications were collected. Results were analyzed using t-tests and logistic regression. Results: Biopsied organs included mainly lung (n = 31), liver (n = 50), and lymph nodes (n = 18). The average number of core biopsy passes was 3.45 in the study group and 2.18 in the control group (0.73, 1.81; p = 0.0001). The average study patient underwent 1.44 biopsy procedures by radiology from 2016 to 2017, whereas the average control patient underwent 1.08 (0.1657, 0.5010, p = 0.0002). Results were similar when looking at the subset of patients undergoing liver biopsies. In our cohort of 120 patients total, only 6 complications were noted. There were 4 complications in the control patients and 2 complications in the study patients, all of which were pneumothoraces in patients undergoing lung biopsy; only 2 of these required treatment. The odds ratio for a complication occurring from an increase in one core biopsy is 1.07 (0.601, 1.573; p = 0.775), suggesting no significant relationship among the number of biopsies taken and the probability of complication in this cohort. Conclusions: Patients being biopsied for genetic profiling or clinical study enrollment are undergoing more biopsy procedures and more biopsy passes per procedure, but are not experiencing a detectable increased rate of complications in this small cohort, single-center study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗