Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Stopping Power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Positron-impact electronic excitations and mass stopping power of H 2

Positron-impact electronic excitation cross sections, mean excitation energies, and mass stopping power of the H 2 molecule have been calculated for energies from 10 eV up to 2 keV using the convergent close-coupling method that utilizes single- and two-center expansions. Overall, results are compared to previous studies. Application of Bragg's rule of stopping power additivity is discussed by comparing results obtained for atomic (H) and molecular (H 2 ) targets for positron impact.

74 ATOMIC AND MOLECULAR PHYSICS↗

Analysis of CT Numbers and Relative Proton Stopping Powers for Real Tissue Samples

The accuracy of computer planning of clinical proton dose distribution is partly determined by the precision of the conversion of CT Hounsfield Units to relative proton stopping powers. The calibration curves from three different sources were compared. We have found about 5% differences between proton stopping power values in the range from -700 HU to 0 HU. Calibration data for several soft tissues and phantom materials were also experimentally measured. The data for the tissues are in a good agreement with the calibration curves however data for phantom materials have significant deviations.

07 ISOTOPE AND RADIATION SOURCES↗

Investigation of stopping power for deuterons in partially ionized warm Al plasmas

The stopping powers for deuterons in Al plasmas with a fixed density of 0.02 g/cm{sup 3} and the temperatures at 4.5, 13, and 17 eV are studied in detail for a wide projectile energy range with different models. Comparison of these models indicates that our model is totally in best agreement with the experimental data and the main reason for this is that our calculation for the inelastic processes should be the most reliable. It is found that the difference between our model and the local density approximation model (Wang et al., Phys. Plasmas 5, 2977 (1998)) is mainly due to the quite different physical picture behind them. In Mehlhorn's model (J. Appl. Phys. 52, 6522 (1981)), the Bethe equation is found to overestimate the inelastic stopping in Al plasmas, meanwhile, it is gradually close to our results with temperature decreasing. The model by classical dielectric function with the choice of the maximum of the momentum transfer associated with the temperature is found not suitable to describe the stopping in warm plasmas. With temperature increasing the stopping due to plasma wave rises up which rapidly exceeds the inelastic stopping in warm Al plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma stopping-power measurements reveal transition from non-degenerate to degenerate plasmas

Physically realized electron gas systems usually reside in either the quantum non-degenerate or fully degenerate limit, where the average de Broglie wavelength of the thermal electrons becomes comparable with the interparticle distance between electrons. A few systems, such as young brown dwarfs and the cold dense fuels created in imploded cryogenic capsules at the National Ignition Facility, lie between these two limits and are partially degenerate. The National Ignition Facility has the unique capability of varying the electron quantum degeneracy by adjusting the laser drive used to implode the capsules. This allows experimental studies of the effects of the degeneracy level on plasma transport properties. By measuring rare nuclear reactions in these cold dense fuels, we show that the electron stopping power, which is the rate of energy loss per unit distance travelled by a charged particle, changes with increasing electron density. We observe a quantum-induced shift in the peak of the stopping power using diagnostics that measure above and below this peak. The observed changes in the stopping power are shown to be unique to the transition region between non-degenerate and degenerate plasmas. Furthermore, our results support the screening models applied to partially degenerate astrophysical systems such as young brown dwarfs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-407: Evaluation of the Stopping Power and Imaging Visibility for Iodine Based Contrast in Proton Therapy

Purpose: The purpose of this study was to investigate the difference between calculated and measured relative linear stopping power (RLSP) for contrast medium in proton therapy. Furthermore, the visibility for different concentrations in prostate phantom on orthogonal X-ray system was evaluated Methods and Materials: In prostate cancer patient, rectal balloon along with the contrast media was used to visualize the balloon position, thus facilitating the patient setup during each fraction of the uniform scanning proton treatment. There were no fiducial markers implanted in the prostate for this patient. A blue wax phantom with outer dimensions 10cm(H) x 14.5cm(L) x 10cm(W) was made in house. To hold iodine based contrast solution, a rectangular shaped hole with dimensions 7cm(H) x 8cm(L) x 4cm(W) was made inside the phantom. Organically bound 8.5% iodine based Cystografin Dilute contrast agent with molecular formula C11H9I3N2O4.C7H17NO5 was used in this study. Six solutions were prepared; each mixture of water and iodine based contrast agent at different concentrations as 0%, 5%, 10%, 20%, 30% and 50%. During computed tomographic(CT) simulation, solutions were placed together at the isocenter of CT and scanned at 120kVp using the same protocol as for prostate cancer patients. The treatment planning was done in CMS-XiO system. Multi-layer-ion-chamber (MLIC) was used to measure residual proton range. Results: The 50% concentration contrast solution was used during treatment for better visualization on orthogonal X-ray image. The measured RLSP for 5%, 10%, 20%, 30% & 50% solutions were 1.005, 1.010, 1.018, 1.023 & 1.033; and similarly calculated RLSP from XiO were 1.090, 1.135, 1.222, 1.299 & 1.448 respectively. Conclusion: The treatment planning system could overestimates the relative stopping power of contrast solution with high concentrations. It is recommended to override the contrast with measured RLSP for high atomic number based contrast solution in treatment planning for proton therapy.

60 APPLIED LIFE SCIENCES↗

Wake effect and stopping power for a charged ion moving in magnetized two-component plasmas: Two-dimensional particle-in-cell simulation

A two-dimensional particle-in-cell (PIC) model is proposed to study the wake field and stopping power induced by a nonrelativistic charged particle moving perpendicular to the external magnetic field in two-component plasmas. The effects of the magnetic field on the wake potential and the stopping due to the polarization of both the plasma ions and electrons are discussed. The velocity fields of plasma ions and electrons are investigated, respectively, in the weak and strong magnetic field cases. Our simulation results show that in the case of weak magnetic field and high ion velocity, the wakes exhibit typical V-shaped cone structures and the opening cone angles decrease with the increasing ion velocity. As the magnetic field becomes strong, the wakes lose their typical V-shaped structures and become highly asymmetrical. Similar results can be obtained in the case of low ion velocity and strong magnetic field. In addition, stopping power is calculated and compared with previous one-dimensional and full three-dimensional PIC results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Accelerating multiscale electronic stopping power predictions with time-dependent density functional theory and machine learning

Knowing the rate at which particle radiation releases energy in a material, the “stopping power,” is key to designing nuclear reactors, medical treatments, semiconductor and quantum materials, and many other technologies. While the nuclear contribution to stopping power, i.e., elastic scattering between atoms, is well understood in the literature, the route for gathering data on the electronic contribution has for decades remained costly and reliant on many simplifying assumptions, including that materials are isotropic. We establish a method that combines time-dependent density functional theory (TDDFT) and machine learning to reduce the time to assess new materials to hours on a supercomputer and provide valuable data on how atomic details influence electronic stopping. Our approach uses TDDFT to compute the electronic stopping from first principles in several directions and then machine learning to interpolate to other directions at a cost of 10 million times fewer core-hours. We demonstrate the combined approach in a study of proton irradiation in aluminum and employ it to predict how the depth of maximum energy deposition, the “Bragg Peak,” varies depending on the incident angle—a quantity otherwise inaccessible to modelers and far outside the scales of quantum mechanical simulations. The lack of any experimental information requirement makes our method applicable to most materials, and its speed makes it a prime candidate for enabling quantum-to-continuum models of radiation damage. The prospect of reusing valuable TDDFT data for training the model makes our approach appealing for applications in the age of materials data science.

36 MATERIALS SCIENCE↗

Electron mass stopping power in H 2

Calculations of electron mass stopping power (SP) of electrons in ${\mathrm{H}}_{2}$ have been performed here using the convergent close-coupling method for incident electron energies up to 2000 eV. Convergence of the calculated SP has been established by increasing the size of the close-coupling expansion from 9 to 491 states. Good agreement was found with the SP measurements of Munoz et al. [Chem. Phys. Lett. 433, 253 (2007)].

74 ATOMIC AND MOLECULAR PHYSICS↗

Stopping Power Of He, C And O In InN

Group III nitrides such as InN, GaN, and their alloys are increasingly important in a host of optoelectronic and electronic devices. The presence of unintentional impurities is one of the factors that can strongly affect the electronic properties of these materials, and thus ion beam analysis techniques can play a fundamental role, in particular heavy ion elastic recoil detection analysis tracing and quantifying these contaminations. However, stopping powers in InN and GaN have not yet been measured, and data analysis relies on using the Bragg rule, which is often inaccurate. We have used a bulk method, previously developed by us and applied successfully to other systems, to determine experimentally the stopping power of several ions in InN. The results of our measurements and bulk method analysis are presented.

36 MATERIALS SCIENCE↗

Stopping Power for Degenerate Electrons

This is a first attempt at calculating the BPS stopping power with electron degeneracy corrections. Section I establishes some notation and basic facts. Section II outlines the basics of the calculation, and in Section III contains some brief notes on how to proceed with the details of the calculation. The remaining work for the calculation starts with Section III.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mixed stochastic-deterministic time-dependent density functional theory: application to stopping power of warm dense carbon

Warm dense matter (WDM) describes an intermediate phase, between condensed matter and classical plasmas, found in natural and man-made systems. In a laboratory setting, WDM is often created dynamically. It is typically laser or pulse-power generated and can be difficult to characterize experimentally. Measuring the energy loss of high energy ions, caused by a WDM target, is both a promising diagnostic and of fundamental importance to inertial confinement fusion research. However, electron coupling, degeneracy, and quantum effects limit the accuracy of easily calculable kinetic models for stopping power, while high temperatures make the traditional tools of condensed matter, e.g. time-dependent density functional theory (TD-DFT), often intractable. In this study, we have developed a mixed stochastic-deterministic approach to TD-DFT which provides more efficient computation while maintaining the required precision for model discrimination. Recently, this approach showed significant improvement compared to models when compared to experimental energy loss measurements in WDM carbon. Here, we describe this approach and demonstrate its application to warm dense carbon stopping across a range of projectile velocities. We compare direct stopping-power calculation to approaches based on combining homogeneous electron gas response with bound electrons, with parameters extracted from our TD-DFT calculations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

TU-FG-BRB-04: A New Optimization Method for Pre-Treatment Patient-Specific Stopping-Power by Combining Proton Radiography and X-Ray CT

Purpose: The relative stopping power (RSP) uncertainty is the largest contributor to the range uncertainty in proton therapy. The purpose of this work is to develop a robust and systematic method that yields accurate patient specific RSPs by combining pre-treatment X-ray CT and daily proton radiography. Methods: The method is formulated as a penalized least squares optimization (PLSO) problem min(|Ax-B|). The matrix A represents the cumulative path-length crossed in each material computed by calculating proton trajectories through the X-ray CT. The material RSPs are denoted by x and B is the pRad, expressed as water equivalent thickness. The equation is solved using a convex-conic optimizer. Geant4 simulations were made to assess the feasibility of the method. RSP extracted from the Geant4 materials were used as a reference and the clinical HU-RSP curve as a comparison. The PLSO was first tested on a Gammex RMI-467 phantom. Then, anthropomorphic phantoms of the head, pelvis and lung were studied and resulting RSPs were evaluated. A pencil beam was generated in each phantom to evaluate the proton range accuracy achievable by using the optimized RSPs. Finally, experimental data of a pediatric head phantom (CIRS) were acquired using a recently completed experimental pCT scanner. Results: Numerical simulations showed precise RSP (<0.75%) for Gammex materials except low-density lung (LN-300) (1.2%). Accurate RSP have been obtained for the head (µ=−0.10%, 1.5σ=1.12%), lung (µ=−0.33, 1.5σ=1.02%) and pelvis anthropomorphic phantoms (µ=0.12, 1.5σ=0,99%). The range precision has been improved with an average R80 difference to the reference (µ±1.5σ) of −0.20±0.35%, −0.47±0.92% and −0.06±0.17% in the head, lung and pelvis phantoms respectively, compared to the 3.5% clinical margin. Experimental HU-RSP curve have been produced on the CIRS pediatric head. Conclusion: The proposed PLSO with prior knowledge X-ray CT shows promising potential (R80 σ<1.0% over all sites) to decrease the range uncertainty.

60 APPLIED LIFE SCIENCES↗

Response of a DRAM to single-ion tracks of different heavy-ion species and stopping powers

Multiple-bit errors caused by single-ion tracks in a 256-kb DRAM fabricated by a bulk process were observed for different ion species and stopping power values. The results demonstrate the utility of this device for the evaluation of ion-beam uniformity and ion-beam-induced charge collection in IC devices. The data indicate that single-ion-induced charge transport results in multiple-bit error clusters due to lateral diffusion of excess minority carriers (electrons). Charge collection occurred from a depth of up to 35 microns from the surface of the device. An apparent charge loss was observed for very heavy ions with a high stopping power (Au at 350 MeV).

Zoutendyk, J. A.↗

Stopping power of fluorides and semiconductor organic films for low-velocity protons

A combined experimental and theoretical study of the energy loss of protons in fluorides and organic films is presented. The measurements were performed in fresh AlF{sub 3}, LiF, and N,N{sup '}-bis(1-ethylpropyl)-perylene-3,4,9,10-tetracarboxdiimide (EP-PTCDI) evaporated in situ on self-supported C or Ag foils, covering the very low energy range from 25 keV down to 0.7 keV. The transmission method is used in combination with time-of-flight (TOF) spectrometry. In the case of fluorides with large band gap energies (AlF{sub 3} and LiF), the experimental stopping power increases almost linearly with the mean projectile velocity showing a velocity threshold at about 0.1 a.u. These features are well reproduced by a model based on quantum scattering theory that takes into account the velocity distribution and the excitation of the active 2p electrons in the F{sup -} anions, and the properties of the electronic bands of the insulators. In the case of the semiconductor organic film with a lower gap, the experimental stopping power increases linearly with the mean projectile velocity without presenting a clear threshold. This trend is also reproduced by the proposed model.

74 ATOMIC AND MOLECULAR PHYSICS↗

Reaction-in-flight neutrons as a test of stopping power in degenerate plasmas

We present the first measurements of reaction-in-flight (RIF) neutrons in an inertial confinement fusion system. The experiments were carried out at the National Ignition Facility, using both Low Foot and High Foot drives and cryogenic plastic capsules. In both cases, the high-energy RIF (E n > 15 MeV) component of the neutron spectrum was found to be about 10 –4 of the total. The majority of the RIF neutrons were produced in the dense cold fuel surrounding the burning hotspot of the capsule, and the data are consistent with a compressed cold fuel that is moderately to strongly coupled (Γ~ 0.6) and electron degenerate (θ Fermi /θ e ~ 4). The production of RIF neutrons is controlled by the stopping power in the plasma. Thus, the current RIF measurements provide a unique test of stopping power models in an experimentally unexplored plasma regime. In conclusion, we find that the measured RIF data strongly constrain stopping models in warm dense plasma conditions, and some models are ruled out by our analysis of these experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

TU-FG-BRB-01: Dual Energy CT Proton Stopping Power Ratio Calibration and Validation with Animal Tissues

Purpose: The conversion of Hounsfield Unit (HU) to proton stopping power ratio (SPR) is a main source of uncertainty in proton therapy. In this study, the SPRs of animal tissues were measured and compared with prediction from dual energy CT (DECT) and single energy CT (SECT) calibrations. Methods: A stoichiometric calibration method for DECT was applied to predict the SPR using CT images acquired at 80 kVp and 140 kVp. The dual energy index was derived based on the HUs of the paired spectral images and used to calculate the SPRs of the materials. Tissue surrogates with known chemical compositions were used for calibration, and animal tissues (pig brain, liver, kidney; veal shank, muscle) were used for validation. The materials were irradiated with proton pencil beams, and SPRs were deduced from the residual proton range measured using a multi-layer ion chamber device. In addition, Gafchromic EBT3 films were used to measure the distal dose profiles after irradiation through the tissue samples and compared with those calculated by the treatment planning system using both DECT and SECT predicted SPRs. Results: The differences in SPR between DECT prediction and measurement were −0.31±0.36% for bone, 0.47±0.42% for brain, 0.67±0.15% for liver, 0.51±0.52% for kidney, and −0.96±0.15% for muscle. The corresponding results using SECT were 3.1±0.12%, 1.90±0.45%, −0.66±0.11%, 2.33±0.21%, and −1.70±0.17%. In the film measurements, average distances between film and calculated distal dose profiles were 0.35±0.12 mm for DECT calibration and −1.22±0.12 mm for SECT calibration for a beam with a range of 15.79 cm. Conclusion: Our study indicates that DECT is superior to SECT for proton SPR prediction and has the potential to reduce the range uncertainty to less than 2%. DECT may permit the use of tighter distal and proximal range uncertainty margins for treatment, thereby increasing the precision of proton therapy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of High Stopping Power Bismuth-Loaded Plastic Scintillators for Radiation Portal Monitors

Plastic scintillators are widely used in radiation portal monitors because of their low cost and availability in large sizes. However, due to their low density and low effective atomic number (Z), they offer low intrinsic efficiency and little spectroscopic information. The addition of high-Z constituents to these plastics can greatly increase both their total stopping power and the amount of photoelectric absorption, leading to full-energy deposition and thus useful gamma spectra. Herein, we present the performance of the latest formulation of Bi-loaded plastic scintillators showing their useful spectroscopic information up to relatively high energy (~1 MeV) due to their high stopping power compared to the current commercially available plastics. These Bi-loaded plastics use 20 weight percent (wt%) Bi-pivalate (8 wt% elemental Bi) dissolved in polyvinyltoluene (PVT) matrix and conventional fast fluors (~10 ns decay time). These Bi-loaded plastics achieve up to approximately 6000 photons/MeV and have been produced in sizes up to 17 in 3 . The performance of these Bi-loaded plastics is also demonstrated in the existing portal monitor hardware (Rapiscan Model TSA Trainer 770) showing the possibility to provide improved sensitivity as a drop-in replacement with continued scale-up.

42 ENGINEERING↗

TU-EF-304-06: A Comparison of CT Number to Relative Linear Stopping Power Conversion Curves Used by Proton Therapy Centers

Purpose: To compare the CT Number (CTN) to Relative Linear Stopping Power (RLSP) conversion curves used by 14 proton institutions in their dose calculations. Methods: The proton institution’s CTN to RLSP conversion curves were collected by the Imaging and Radiation Oncology Core (IROC) Houston QA Center during its on-site dosimetry review audits. The CTN values were converted to scaled CT Numbers. The scaling assigns a CTN of 0 to air and 1000 to water to allow intercomparison. The conversion curves were compared and the mean curve was calculated based on institutions’ predicted RLSP values for air (CTN 0), lung (CTN 250), fat (CTN 950), water (1000), liver (CTN 1050), and bone (CTN 2000) points. Results: One institution’s curve was found to have a unique curve shape between the scaled CTN of 1025 to 1225. This institution modified its curve based on the findings. Another institution had higher RLSP values than expected for both low and high CTNs. This institution recalibrated their two CT scanners and the new data placed their curve closer to the mean of all institutions. After corrections were made to several conversion curves, four institutions still fall outside 2 standard deviations at very low CTNs (100–200), and two institutions fall outside between CTN 850–900. The largest percent difference in RLSP values between institutions for the specific tissues reviewed was 22% for the lung point. Conclusion: The review and comparison of CTN to RLSP conversion curves allows IROC Houston to identify any outliers and make recommendations for improvement. Several institutions improved their clinical dose calculation accuracy as a Result of this review. There is still area for improvement, particularly in the lung area of the curve. The IROC Houston QA Center is supported by NCI grant CA180803.

60 APPLIED LIFE SCIENCES↗