COLD SPRAY COATED METAL MATRIX NANO-COMPOSITE SURFACE LAYERS ON INCONEL 617
This is the final report for the project on cold spray. The application of ball milling approach to prepare alloys of metal powder has been studied in this project.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
This is the final report for the project on cold spray. The application of ball milling approach to prepare alloys of metal powder has been studied in this project.
A simple method of enhancing the oxygen barrier property of a renewable polysaccharide-based multilayer film by increasing the processing temperatures.
Abstract not provided.
Abstract not provided.
Abstract not provided.
Normal emittance of oxidized titanium foil used as plume shields at high temperature significantly increased by plasma coating with specific ceramic materials.
The effects of BaF2-CaF 2 particle morphology on PS304 feedstock powder flow ability have been investigated. BaF2-CaF2 eutectic powders were fabricated by comminution (angular) and by gas atomization (spherical). The fluoride powders were added incrementally to the other powder constituents of the PS304 feedstock: nichrome, chromia, and silver powders. A linear relationship between flow time and concentration of BaF2-CaF2 powder was found. Flow of the powder blend with spherical BaF2-CaF2 was better than the angular BaF2-CaF2. Flow ability of the powder blend with angular fluorides decreased linearly with increasing fluoride concentration. Flow of the powder blend with spherical fluorides was independent of fluoride concentration. Results suggest that for this material blend, particle morphology plays a significant role in powder blend flow behavior, offering potential methods to improve powder flow ability and enhance the commercial potential. These findings may have applicability to other difficult-to-flow powders such as cohesive ceramics.
LCR304 is a solid lubricant coating composed of Ni-10Cr, Cr2O3, BaF2-CaF2 and Ag and developed for dimensional stability in high temperature air. This coating is a modification of PS304, which differs in that the Ni-Cr constituent contains 20wt% Cr. The tribological characteristics of LCR304 were evaluated by pin-on-disk and foil air bearing rig testing from 25 to 650 C and compared to previous test results with PS304. For both tests, the friction coefficient decreased as temperature increased from 25 to 650 C. Wear generally decreased with increasing temperature for all pin-on-disk tests. LCR304 coated components produced the least wear of Inconel X-750 counterface materials at 427 and 650 C. These results indicate that the LCR304 coating has potential as a replacement for PS304 in, for example, low cycle (minimum wear) applications where dimensional stability is imperative.
Abstract not provided.
Abstract not provided.
For presentation at, and publication in the proceedings of, the AMPP Annual Conference + Expo 2024, New Orleans, LA, March 3-7, 2024.
This work focuses on porous transport electrodes (PTEs), which integrate the anodic catalyst with the adjacent Ti porous transport layer (PTL). Challenges in catalyst deposition on PTLs, particularly at low loadings, motivated this study to evaluate various fabrication methods and characterization approaches. This work investigated Pt-treated PTLs coated with Ir-based catalysts using several common methods, including airbrush coating, rod coating, ultrasonic spray coating, electrodeposition, and sputter deposition, with catalyst loadings ranging from 2.9 to 0.1 mg/cm 2 , providing the opportunity for comparisons across a large set of samples produced by different methods. Two widely accessible characterization techniques: X-ray computed tomography (XCT) and scanning electron microscopy energy dispersive X-ray spectroscopy (SEM-EDS) were explored. Initial evaluation of selected samples with XCT provided qualitative insights into catalyst distribution, however comprehensive quantitative analysis was limited. SEM-EDS enabled detailed information on the catalyst distribution both qualitatively and quantitatively using two metrics. Atomic and surface area % ratios of Pt:Ir and Ti:Ir revealed trends in catalyst loading and losses into the PTL pores, as well as evaluating the homogeneity of catalyst coatings. The analysis demonstrated that ultrasonic spray coating, electrodeposition, and sputter coating produced the most homogeneous coatings, with minimal catalyst losses observed for electrodeposition and sputter coating. By adapting common techniques with novel, standardized methodologies, this work establishes a universally applicable framework for cross-study comparison of PTEs. The SEM-EDS approach provides a practical, accessible tool for PTE characterization and contributes a reference dataset supporting both research development and rapid quality control.
Eighteen plasma sprayed coating systems, nine based on the NiCoCrAly chemistry and nine based on the CoCrAly composition, were evaluated to identify coating systems which provide equivalent or superior life to that shown by the electron beam physical vapor deposited NiCoCrAly and CoCrAly coatings respectively. NiCoCrAly type coatings were examined on a single crystal alloy and the CoCrAly based coatings were optimized on the B1900+ Hf alloy. Cyclic burner rig oxidation and hot corrosion and tensile ductility tests used to evaluate the various coating candidates. For the single crystal alloy, a low pressure chamber plasma sprayed NiCoCrAly + Si coating exhibited a 2x oxidation life improvement at 1394 K (2050 F) over the vapor deposited NiCoCrAly material while showing equivalent tensile ductility. A silicon modified low pressure chamber plasma sprayed CoCrAly coating was found to be more durable than the baseline vapor deposited CoCrAly coating on the B1900+ Hf alloy.
Eighteen plasma sprayed coating systems, nine based on the NiCoCrAlY chemistry and nine based on the CoCrAlY composition, were evaluated to identify coating systems which will provide equivalent or superior life to that shown by the electron beam physical vapor deposited NiCoCrAlY and CoCrAlY coatings respectively. NiCoCrAlY-type coatings were examined on a single crystal alloy and the CoCrAlY based coatings were optimized on the B1900 + Hf alloy. Cyclic burner rig oxidation and hot corrosion and tensile ductility tests were used to evaluate the various coating candidates. For the single crystal alloy, a low pressure chamber plasma sprayed NiCoCrAlY + Si coating exhibited a 2X oxidation life improvement at 1121 C (2050 F) over the vapor deposited NiCoCrAlY material while showing equivalent tensile ductility. A silicon modified low pressure chamber plasma sprayed CoCrAlY coating was found to be more durable than the baseline vapor deposited CoCrAlY coating on the B1900 + Hf alloy.
With the advent of new environmental laws restricting volatile organic compounds and hexavalent chrome emissions, 'environmentally safe' thermal spray coatings are being developed to replace the traditional corrosion protection chromate primers. A wire arc sprayed aluminum coating is being developed for corrosion protection of low pressure liquid hydrogen carrying ducts on the Space Shuttle Main Engine. Currently, this hardware utilizes a chromate primer to provide protection against corrosion pitting and stress corrosion cracking induced by the cryogenic operating environment. The wire are sprayed aluminum coating has been found to have good potential to provide corrosion protection for flight hardware in cryogenic applications. The coating development, adhesion test, corrosion test and cryogenic flexibility test results will be presented.
Effect of surface roughness and spray powders on shear bond strength of plasma-sprayed alumina coatings on stainless steel
We report internal pipeline corrosion due to carbon dioxide (CO 2 ) is a major challenge facing the oil and gas industry. The objective of this study was to investigate the corrosion behavior of aluminum (Al)-based alloys as sacrificial coatings to protect pipelines in a CO 2 -saturated aqueous electrolyte (3.5 wt% NaCl) at 4 bar CO 2 partial pressure (3 bar) and 40°C. The corrosion resistance of Al-based alloys and thermal spray coatings was evaluated in an electrochemical reaction autoclave using electrochemical methods (potentiodynamic polarization, linear polarization resistance, and electrochemical impedance spectroscopy). Post-corrosion surface characterization was performed by scanning electron microscopy equipped with energy-dispersive x-ray spectroscopy. The obtained data show Al-based alloys demonstrated promising protection against CO 2 corrosion with no breakaway degradation issues.