Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectrum Analysis, Raman”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Diffuse Reflectance Spectroscopy and Principal Component Analysis to Retrospectively Determine Production History of Plutonium Dioxide

Diffuse reflectance spectroscopy measurements in the shortwave infrared (930–1600 nm) spectral region were acquired for Pu 2 (C 2 O 4 ) 3 •9H 2 O and its thermal decomposition product, PuO 2 . We analyzed a total of eight PuO 2 samples that were produced at different calcination temperatures (300, 350, 450, 525, 600, 675, 750, and 900 °C). Our goal was to identify spectroscopic fingerprints that could be used to gain retrospective information regarding the production parameters of these important nuclear compounds. The diffuse reflectance spectrum of Pu 2 (C 2 O 4 ) 3 •9H 2 O features several broad bands that currently preclude detailed analysis. However, all PuO 2 samples produced relatively sharp spectral features that got sharper and more intense for samples that were produced at higher calcination temperatures. The electronic band observed at 1433 nm in the diffuse reflectance spectra of PuO 2 was found to be a sensitive indicator of crystallinity; a result that is corroborated by ancillary Raman spectroscopy measurements. Principal component analysis of diffuse reflectance spectra was able to clearly rank and categorize PuO 2 samples based on the calcination temperature that was employed during their production. Thus, we show herein that important retrospective information pertaining to the process history of PuO 2 can be gained through the relatively simplistic combination of diffuse reflectance spectroscopy and principal component analysis. This discovery presents a new method for determining the provenance and process history of PuO 2 and should have an impact in the fields of nuclear forensics and nuclear nonproliferation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Investigation of Americium-Containing Phosphates, Silicates, Borates, Molybdates, and Fluorides Synthesized via High-Temperature Flux Crystal Growth

The crystal chemistry of americium-containing extended structures was investigated, and several classes of americium-containing solid-state oxide materials were obtained in single-crystal form via high-temperature flux crystal growth. This enabled the structural characterization of rare examples of ternary, quaternary, and penternary americium-containing silicates K 3 Am (Si 2 O 7 ) and Cs 6 Am 2 Si 21 O 48 , phosphates Na 3 Am (PO 4 ) 2 and K 3 Am (PO 4 ) 2 , borates Ba 3 Am 2 (BO 3 ) 4 and AmBO 3 , borate halides Ca 5 Am(BO 3 ) 4 Cl, molybdates Li 0.5 Am 0.5 MoO 4 , and fluorides CsAm 2 F 7 . Using these crystallographic data, the ionic radii of Am 3+ with coordination numbers of six (0.975 Å), seven (1.052 Å), and nine (1.162 Å) were established. A maximum entropy method (MEM) analysis was performed on the single-crystal X-ray diffraction data that were collected for K 3 Nd(PO 4 ) 2 /K 3 Am(PO 4 ) 2 , K 3 NdSi 2 O 7 /K 3 AmSi 2 O 7 , and NdBO 3 /AmBO 3 , to qualitatively compare the ionicities of the Nd–O and Am–O bonds. In conclusion, Raman spectroscopy data were collected on single crystals of K 3 Am(PO 4 ) 2 and compared to the calculated Raman spectrum of K 3 Am(PO 4 ) 2 obtained from DFT calculations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measuring Rocket Engine Temperatures with Hydrogen Raman Spectroscopy

Optically accessible, high pressure, hot fire test articles are available at NASA Marshall for use in development of advanced rocket engine propellant injectors. Single laser-pulse ultraviolet (UV) Raman spectroscopy has been used in the past in these devices for analysis of high pressure H2- and CH4-fueled combustion, but relies on an independent pressure measurement in order to provide temperature information. A variation of UV Raman (High Resolution Hydrogen Raman Spectroscopy) is under development and will allow temperature measurement without the need for an independent pressure measurement, useful for flows where local pressure may not be accurately known. The technique involves the use of a spectrometer with good spectral resolution, requiring a small entrance slit for the spectrometer. The H2 Raman spectrum, when created by a narrow linewidth laser source and obtained from a good spectral resolution spectrograph, has a spectral shape related to temperature. By best-fit matching an experimental spectrum to theoretical spectra at various temperatures, a temperature measurement is obtained. The spectral model accounts for collisional narrowing, collisional broadening, Doppler broadening, and collisional line shifting of each Raman line making up the H2 Stokes vibrational Q-branch spectrum. At pressures from atmospheric up to those associated with advanced preburner components (5500 psia), collisional broadening though present does not cause significant overlap of the Raman lines, allowing high resolution H2 Raman to be used for temperature measurements in plumes and in high pressure test articles. Experimental demonstrations of the technique are performed for rich H2-air flames at atmospheric pressure and for high pressure, 300 K H2-He mixtures. Spectrometer imaging quality is identified as being critical for successful implementation of technique.

Wehrmeyer, Joseph A.↗

Lattice-shifted nematic quantum critical point in FeSe 1-x S x

We report the evolution of nematic fluctuations in FeSe 1-x S x single crystals as a function of Sulfur content x across the nematic quantum critical point (QCP) x c ~ 0.17 via Raman scattering. The Raman spectra in the B1g nematic channel consist of two components, but only the low energy one displays clear fingerprints of critical behavior and is attributed to itinerant carriers. Curie–Weiss analysis of the associated nematic susceptibility indicates a substantial effect of nemato-elastic coupling, which shifts the location of the nematic QCP. We argue that this lattice-induced shift likely explains the absence of any enhancement of the superconducting transition temperature at the QCP. The presence of two components in the nematic fluctuations spectrum is attributed to the dual aspect of electronic degrees of freedom in Hund’s metals, with both itinerant carriers and local moments contributing to the nematic susceptibility.

36 MATERIALS SCIENCE↗

Remote Raman Sensor System for Testing of Rocks and Minerals

Recent and future explorations of Mars and lunar surfaces through rovers and landers have spawned great interest in developing an instrument that can perform in-situ analysis of minerals on planetary surfaces. Several research groups have anticipated that for such analysis, Raman spectroscopy is the best suited technique because it can unambiguously provide the composition and structure of a material. A remote pulsed Raman spectroscopy system for analyzing minerals was demonstrated at NASA Langley Research Center in collaboration with the University of Hawaii. This system utilizes a 532 nm pulsed laser as an excitation wavelength, and a telescope with a 4-inch aperture for collecting backscattered radiation. A spectrograph equipped with a super notch filter for attenuating Rayleigh scattering is used to analyze the scattered signal. To form the Raman spectrum, the spectrograph utilizes a holographic transmission grating that simultaneously disperses two spectral tracks on the detector for increased spectral range. The spectrum is recorded on an intensified charge-coupled device (ICCD) camera system, which provides high gain to allow detection of inherently weak Stokes lines. To evaluate the performance of the system, Raman standards such as calcite and naphthalene are analyzed. Several sets of rock and gemstone samples obtained from Ward s Natural Science are tested using the Raman spectroscopy system. In addition, Raman spectra of combustible substances such acetone and isopropanol are also obtained. Results obtained from those samples and combustible substances are presented.

Garcia, Christopher S.↗

Single-Shot Rotational Raman Thermometry for Turbulent Flames Using a Low-Resolution Bandwidth Technique

An alternative optical thermometry technique that utilizes the low-resolution (order 10(exp 1)/cm) pure-rotational spontaneous Raman scattering of air is developed to aid single-shot multiscalar measurements in turbulent combustion studies. Temperature measurements are realized by correlating the measured envelope bandwidth of the pure-rotational manifold of the N2/O2 spectrum with a theoretical prediction of a species-weighted bandwidth. By coupling this thermometry technique with conventional vibrational Raman scattering for species determination, we demonstrate quantitative spatially resolved, single-shot measurements of the temperature and fuel/oxidizer concentrations in a high-pressure turbulent Cf4-air flame. Our technique provides not only an effective means of validating other temperature measurement methods, but also serves as a secondary thermometry technique in cases where the anti-Stokes vibrational N2 Raman signals are too low for a conventional vibrational temperature analysis.

Kojima, Jun↗

Surface Analysis of 4-Aminothiophenol Adsorption at Polycrystalline Platinum Electrodes

Formation of self-assembled monolayer (SAM) of 4-aminothiophenol (4-ATP) on polycrystalline platinum electrodes has been studied by surface analysis and electrochemistry techniques. The 4-ATP monolayer was characterized by cyclic voltammetry (CV), Raman spectroscopy, reflection absorption infrared (RAIR) spectroscopy, and X-ray photoelectron spectroscopy (XPS). Cyclic voltammetry (CV) experiments give an idea about the packing quality of the monolayer. RAIR and Raman spectra for 4-ATP modified platinum electrodes showed the characteristic adsorption bands for neat 4-ATP indicating the adsorption of 4-ATP molecules on platinum surface. The adsorption on platinum was also evidenced by the presence of sulfur and nitrogen peaks by XPS survey spectra of the modified platinum electrodes. High resolution XPS studies and RAIR spectrum for platinum electrodes modified with 4-ATP indicate that molecules are sulfur-bonded to the platinum surface. The formation of S-Pt bond suggests that ATP adsorption gives up an amino terminated SAM. Thickness of the monolayer was evaluated via angle-resolved XPS (AR-XPS) analyses. Derivatization of 4-ATP SAM was performed using 16-Br hexadecanoic acid.

Rosario-Castro, Belinda I.↗

High-resolution rovibrational spectroscopy of trans -formic acid in the v 1 OH stretching fundamental: Dark state coupling and evidence for charge delocalization dynamics

High-resolution infrared (IR) reduced-Doppler absorption spectra of jet-cooled gas phase trans-formic acid in the v 1 OH stretching fundamental region are reported for the first time, obtained by supersonically expanding trans- formic acid/Ar mixtures through a slit jet nozzle source and rotationally cooling to T rot ≈ 10.9(5) K, with ab- sorption signals recorded by high-resolution difference-frequency IR absorption spectroscopy. Two a/b-type rovibrational bands of comparable intensity, one ~10-fold weaker b-type band, and one ~6-fold weaker a-type band are observed, with vibrational band origins at 3570.493(5), 3566.793(5), 3560.032(9), and 3534.6869(2) cm –1 , respectively. Based on previous Raman jet spectroscopic work by Nejad and Sibert [A. Nejad, E.L. Sibert III, The Raman jet spectrum of trans-formic acid and its deuterated isotopologs: Combining theory and experi- ment to extend the vibrational database, J. Chem. Phys. 154(6) (2021) 064301.], these four rovibrational bands have been assigned to v 1 , (v 2 + v 7 ), (v 6 + 2v 7 + 2v 9 ), and 2v 3 , respectively. Specifically, two of the three upper dark states (2 1 7 1 (a') and 6 1 7 2 9 2 (a')) are close enough to the “bright” 1 1 (a') state to facilitate strong anharmonic resonance interactions, which results in intensity mixing into the two zero-order bands that would otherwise be “dark”. Furthermore, our high-resolution spectral analysis reveals that there are local rotational crossings be- tween these zero-order 1 1 and 2 1 7 1 states resulting in extra lines (i.e., some upper levels in the nominally v 1 band have majority zero-order 2 1 7 1 state character). This motivates development of a 3 coupled state (1 1 , 2 1 7 1 , and 6 1 7 2 9 2 ) picture to aid in the spectral analysis, which is able to match all 3 observed band origins and relative band intensities, as well as indicate the necessity of multistate (> 2) coupling. Though limited by range of J and Ka levels (J’ ≤ 9 and K a ’ ≤ 3) populated at supersonic jet temperatures, this work offers first precision spec- troscopic analysis of trans-formic acid in the v 1 OH stretch region, which should aid in assignment of the more complete yet highly congested room temperature FTIR spectra. Lastly, and in sharp contrast to the spectral complexity in the three predominantly b-type bands, the lone a-type 2v 3 rovibrational band at 3534.6869(2) cm –1 is well described by a simple, rigid asymmetric top Hamiltonian.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SO2 Spectroscopy with A Tunable UV Laser

A portion of the fluorescence spectrum of SO2 has been studied using a narrow wavelength doubled dye laser as the exciting source. One purpose of this study is to evaluate the use of SO2 resonance re-emission as a probe of SO2 in the atmosphere. When the SO2 is excited by light at 300.2 nm, for example, a strong reemission peak is observed which is Stokes-shifted from the incident light wavelength by the usual Raman shift (the VI symmetric vibration frequency 1150.5/cm ). The intensity of this peak is sensitive to small changes (.01 nm) in the incident wavelength. Measurements of the N2 quenching and self quenching of this re-emission have been obtained. Preliminary analysis of this data indicates that the quenching is weak but not negligible. The dye laser in our system is pumped by a pulsed N2 laser. Tuning 'and spectral narrowing are accomplished using a telescope-echelle grating combination. In a high power configuration the resulting pulses have a spectral width of about 5 x 10(exp -3) nm and a time duration of about 6 nsec. The echelle grating is rotated by a digital stepping motor, such that each step shifts the wavelength by 6 x 10(exp -4) nm. In addition to the tunable, narrow wavelength uv source and spectral analysis of the consequent re-emission, the system also provides time resolution of the re-emitted light to 6 nsec resolution. This capability is being used to study the lifetime of low pressure S02 fluorescence at different wavelengths and pressures.

Morey, W. W.↗

Two-dimensional burn velocity and analysis of burn products of nitromethane at high pressure

We have studied the laser-initiated deflagration of nitromethane (CH 3 NO 2 ) under high static pressure in the diamond anvil cell. Time-resolved images of the deflagrations have been obtained using intensified CCDs (ICCD). In contrast with previous work, we rely on spontaneous emission from the reaction, rather than changes in the speckle pattern produced by artificial illumination of the sample. Furthermore, as opposed to the 1D records obtained previously with streak cameras, ICCDs permit imaging of the burn in two dimensions providing the ability to directly observe anisotropic deflagration behavior. Here, we report several examples of this behavior and discuss its possible origins. We have also investigated the products of the reaction using Raman spectroscopy. At pressures below 25 GPa, the burn product is observed to be opaque and has a Raman spectrum consistent with a carbonaceous soot. At pressures above 25 GPa, the burn product is observed to be transparent (consistent with earlier reports) and its Raman spectrum reveals the presence of molecular N 2 and a nitrogen-carbonate species. The latter species can be recovered to ambient pressure and has a Raman spectrum consistent with ammonium carbonate or ammonium bicarbonate. To aid interpretation of the Raman spectra, measurements have also been made on the isotopologues CH 3 15 NO 2 and 13 CH 3 NO 2 . This work establishes the importance of advanced time-resolved imaging to reveal the details of deflagration under high pressure and further advances our understanding of the corresponding chemistry.

Deflagration↗

Glucose determination in human aqueous humor with Raman spectroscopy

It has been suggested that spectroscopic analysis of the aqueous humor of the eye could be used to indirectly predict blood glucose levels in diabetics noninvasively. We have been investigating this potential using Raman spectroscopy in combination with partial least squares (PLS) analysis. We have determined that glucose at clinically relevant concentrations can be accurately predicted in human aqueous humor in vitro using a PLS model based on artificial aqueous humor. We have further determined that with proper instrument design, the light energy necessary to achieve clinically acceptable prediction of glucose does not damage the retinas of rabbits and can be delivered at powers below internationally acceptable safety limits. Herein we summarize our current results and address our strategies to improve instrument design. 2005 Society of Photo-Optical Instrumentation Engineers.

Spectrum Analysis, Raman/methods↗

Network upgrade exploiting multi band: S- or E-band?

Nowadays, the fiber spectrum is only partially exploited, i.e., mainly in the C-band and more recently in the C + L-band, where the fiber attenuation profile experiences the minimum. Thus, fiber communications technology—amplifiers, switching, transceivers, etc.—and networking solutions are mature for those spectrum bands. However, the continuous increase in traffic means that capacity saturation of the current infrastructure is looming. Taking advantage of the unused portions of the spectrum (e.g., the S- and E-bands) may be an efficient solution to accommodate an increase in traffic without installing new fibers. Research is thus investigating multi-band transmission and networking to evaluate and enable such network upgrades. Some issues need to be solved or taken into account, from the enabling technology (e.g., amplifiers in the S- or E-band are still under development) to physical layer effects previously neglected, such as stimulated Raman scattering (SRS). SRS affects wideband transmission, potentially degrading active channels. The contribution of this paper is the investigation of network upgrades for C + L-band systems. In particular, upgrades exploiting the E- and S-bands are compared taking into account each band capacity and the effects of SRS on both new and already deployed channels (in both the C- and L-bands). A detailed analysis of the physical layer is provided also in the presence of guard bands between previously exploited bands and the bands used for upgrade. By leveraging the physical layer assessment, a networking analysis is carried out to evaluate the supported traffic increase and also the signal quality degradation due to SRS on active channels. Overall, the results suggest that upgrades to the E- and S-bands support a comparable increase in traffic. However, the exploitation of the E-band with 14 THz of guard band between the C- and E-bands may avoid detrimental effects to already active channels in the C + L-band, suggesting this upgrade strategy can be the most effective of the two.

47 OTHER INSTRUMENTATION↗

Efficiencies of Rotational Raman, and Rayleigh Techniques for Laser Remote Sensing of the Atmospheric Temperature

Various lidar methods have been developed for measuring the atmospheric temperature, making use of the temperature dependant characteristics of rotational Raman scattering (RRS) from nitrogen and oxygen, and Rayleigh or Rayleigh-Brillowin scattering (RS or RBS). These methods have various advantages and disadvantages as compared to each other but their potential accuracies are principal characteristics of their efficiency. No systematic attempt has been undertaken so far to compare the efficiences, in the above meaning, of different temperature lidar methods. Two RRS techniques have been compared. Here, we do such a comparison using two methods based on the detection and analysis of RS (RBS) spectra. Four methods are considered here for measuring the atmospheric temperature. One of them (Schwiesow and Lading, 1981) is based on an analysis of the RS linewidth with two Michelson interferometers (MI) in parallel. The second method (Shimisu et al., 1986) employs a high-resolution analysis of the RBS line shape. The third method (Cooney, 1972) employs the temperature dependance of the RRS spectrum envelope. The fourth method (Armstrong, 1974) makes use of a scanning Fabry-Perot interferometer (FPI) as a comb filter for processing the periodic RRS spectrum of the nitrogen. Let us denote the corresponding errors in measuring the temperature by sigma(sub MI), sigma(sub HR), sigma(sub ENV), and sigma(sub FPI). Let us also define the ratios chi(sub 1) = sigma(sub MI)/sigma(sub ENV), chi(sub 2) = sigma(sub HR)/sigma(sub ENV), and chi(sub 3) = sigma(sub FPI)/sigma(sub ENV) interpreted as relative errors with respect to sigma(sub ENV).

Ivanova, I. D.↗

Numerical study of pure rotational fs/ps CARS coherence beating at high pressure and for multi-species rotation-vibration non-equilibrium thermometry

Coherent anti-Stokes Raman scattering (CARS) has long been the gold standard for non-intrusively measuring gas temperature in reacting flows such as flames and plasmas. Recently, the development of ultrafast hybrid fs/ps CARS has enabled the exploitation of coherence beating between neighboring spectral lines to simultaneously measure rotational and vibrational temperatures from a single pure rotational spectrum. However, the influence of non-Boltzmann vibrational state distributions and limitations due to collisional dephasing at pressures greater than 1 atm remains unclear. In this work, we use spectral simulations to investigate the effects of non-Boltzmann vibrational state distributions and the applicability of coherence beating at pressures up to 10 atm. We show that short probe pulses can be leveraged to quantify non-Boltzmann vibrational state distributions of N2. Furthermore, we demonstrate that fs/ps CARS coherence beating can simultaneously provide sensitive measurements of rotational and vibrational temperatures of both O2 and N2 in air. A sensitivity analysis was conducted to qualitatively explain the accuracy and precision comparisons between probe delays.

Chen, Timothy Y. (ORCID:0000000330269767)↗

Isotopic Signatures of Lithium Carbonate and Lithium Hydroxide Monohydrate Measured Using Raman Spectroscopy

Lithium isotopic ratios have wide ranging applications as chemical signatures, including improved understanding of geochemical processes and battery development. Measurement of isotope ratios using optical spectroscopies would provide an alternative to traditional mass spectrometric methods, which are expensive and often limited to a chemical laboratory. In this work, Raman spectra of 7 Li 2 CO 3 , 6 Li 2 CO 3 , 7 LiOH*H 2 O and 6 LiOH*H 2 O have been measured to determine the effect of lithium isotope substitution on the Raman molecular vibrations. Thirteen peaks were observed in the spectrum of lithium carbonate, with discernable isotopic shifts occurring in eleven of the thirteen vibrations, two of which have not been previously reported in the literature. The spectrum of lithium hydroxide monohydrate contained nine peaks, with discernable isotopic shifts occurring in eight of the nine vibrations, four of which have not been previously reported in the literature. The Raman spectral data reported here for lithium carbonate and lithium hydroxide monohydrate are in agreement with the previously reported works in the literature, in which the Raman active modes of these molecules were first identified and assigned. However, due to the stability and resolution of the detection system used in this work, isotopic shifts with a magnitude less than one wavenumber have been identified. Principal Component Regression was used to evaluate the sensitivity to isotopic content of small Raman peak shifts in Li 2 CO 3 and indicates differences greater than 2 atom-% could be reliably determined. These measurements add to the body of work on lithium isotope Raman spectroscopy for these two compounds and increases the number of Raman bands which could be used for lithium isotope content analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhanced Raman Monitor Project

Monitoring of gaseous contaminants stems from the need to ensure a healthy and safe environment. NASA/Ames needs sensors that are able to monitor common atmospheric gas concentrations as well as trace amounts of contaminant gases. To provide an accurate assessment of air quality, a monitoring system would need to be continuous and on-line with full spectrum capabilities, allowing simultaneous detection of all gas components in a sample, including both combustible and non-combustible gases. The system demands a high degree of sensitivity to detect low gas concentrations in the low-ppm and sub-ppm regions. For clean and healthy air ('good' category), criteria established by the EPA requires that contaminant concentrations not exceed 4 ppm of carbon monoxide (CO) in an 8 hour period, 60 ppb of ozone(O3) in a one hour period and 30 ppb of sulfur dioxide (SO2) in a 24 hour period. One step below this is the National Ambient Air Quality Standard ('moderate' category) which requires that contaminant concentrations not exceed 9 ppm of carbon monoxide (CO), 120 ppb of ozone (O3) and 140 ppb of sulfur dioxide (SO2) for their respective time periods. Ideally a monitor should be able to detect the concentrations specified in the 'good' category. To benchmark current abilities of Raman technology in gas phase analysis, laboratory experiments were performed to evaluate the RASCAL II anesthetic gas monitor.

Westenskow, Dwayne↗

Immunoassay readout method using extrinsic Raman labels adsorbed on immunogold colloids

An immunoassay readout method based on surface-enhanced Raman scattering (SERS) is described. The method exploits the SERS-derived signal from reporter molecules that are coimmobilized with biospecific species on gold colloids. This concept is demonstrated in a dualanalyte sandwich assay, in which two different antibodies covalently bound to a solid substrate specifically capture two different antigens from an aqueous sample. The captured antigens in turn bind selectively to their corresponding detection antibodies. The detection antibodies are conjugated with gold colloids that are labeled with different Raman reporter molecules, which serve as extrinsic labels for each type of antibody. The presence of a specific antigen is established by the characteristic SERS spectrum of the reporter molecule. A near-infrared diode laser was used to excite efficiently the SERS signal while minimizing fluorescence interference. We show that, by using different labels with little spectral overlap, two different antigenic species can be detected simultaneously. The potential of this concept to function as a readout strategy for multiple analytes is briefly discussed.

NASA Program Advanced Human Support Technology↗

Development of chemometric models to classify solid-state U materials by micro-Raman spectroscopy

Discerning uranium (U) particles found in environmental sampling is of interest for monitoring the peaceful use of nuclear material. In this study, a soft independent modeling of class analogy (SIMCA) library was successfully developed for the classification of a four-class system consisting of α-U 3 O 8 , UO 2 , UO 2 (NO 3 ) 2 ·6H 2 O (UNH), and UO 2 O 2 ·4H 2 O (studtite) by Raman spectroscopy in the presence of matrix particulates and additional outliers. Spectral variability between numerous particles of each type revealed appreciable differences as a function of particle size with respect to hydration state and potential oxide phase within each class. Interclass variability was accounted for using both unsupervised and supervised chemometric models. The supervised SIMCA model displayed reasonable sensitivity for each U class and a high degree of specificity by returning whether a spectrum belonged to one class or not. This work demonstrates how Raman spectral features and chemometrics can be used to distinguish U materials from one another and from matrix materials such as flint clay. Combining the outlined chemometric approach with Raman mapping sequences could provide a rapid, nondestructive technique to characterize the chemical composition of a diverse collection of U compounds amid background samples for environmental sampling, nuclear forensics, and industrial applications.

Actinide↗