Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spares”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Prospective Evaluation of Residual Breast Tissue After Skin- or Nipple-Sparing Mastectomy: Results of the SKINI-Trial

Objective: This study was designed to investigate the presence of residual breast tissue (RBT) after skin-sparing mastectomy (SSM) and nipple-sparing mastectomy (NSM) and to analyse patient- and therapy-related factors associated with RBT. Skin-sparing mastectomy and NSM are increasingly used surgical procedures. Prospective data on the completeness of breast tissue resection is lacking. However, such data are crucial for assessing oncologic safety of risk-reducing and curative mastectomies. Methods: Between April 2016 and August 2017, 99 SSM and 61 NSM were performed according to the SKINI-trial protocol, under either curative (n = 109) or risk-reducing (n = 51) indication. After breast removal, biopsies from the skin envelope (10 biopsies per SSM, 14 biopsies per NSM) were taken in predefined radial localizations and assessed histologically for the presence of RBT and of residual disease. Results: Residual breast tissue was detected in 82 (51.3%) mastectomies. The median RBT percentage per breast was 7.1%. Of all factors considered, only type of surgery (40.4% for SSM vs. 68.9% for NSM; P < 0.001) and surgeon (P < 0.001) were significantly associated with RBT. None of the remaining factors, e.g., skin flap necrosis, was associated significantly with RBT. Residual disease was detected in three biopsies. Conclusions: Residual breast tissue is commonly observed after SSM and NSM. In contrast, invasive or in situ carcinomas are rarely found in the skin envelope. Radicality of mastectomy in this trial is not associated with increased incidence of skin flap necrosis. ClinicalTrials.gov Identifier NCT03470909.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of Transformative Preparation Methods to Push up High Q&G Performance of FRIB Spare HWR Cryomodule Cavities

The FRIB accelerator project construction, a top priority of US nuclear science, was completed in January 2022, and is now moving to user operation. The stable and reliable operation of the accelerating cryomodules is essential in achieving/fulfilling DOE and user expectations. So far, FRIB cryomodules meet all FRIB specifications for cavity performance. However, during the lifetime of machine operation, degradation of cryomodule performance is possible, as reported in similar operating facilities (CEBAF, SNS). If cryomodule degradation is observed at FRIB, the under-performing cryomodule will require replacement/maintenance. In effort to manage operational reliability, FRIB plans to construct a 0.53 half-wave cryomodule to serve as an active spare. In a parallel effort, FRIB will also work toward increasing operational Q and gradient of spare cryomodule cavities to gain an overall performance margin to support future operational reliability. The current FRIB cavity designs have a potential to operate at gradients higher than 8 MV/m, but are currently limited by field emission (FE) and/or high field Q slope (HFQS); known issue in buffered chemical polished (BCP) treated cavities. The proposal looks to develop transformative surface preparation treatments to improve the operational gradient of spare cryomodules higher than 10 MV/m while maintaining high Q. Thus, increasing operational margin by 30 - 50%. With the goal to improve operational reliability set, the proposal will investigate multiple objectives as possible paths forward to achieve an overall increase in cavity performance and gain a better understanding of SRF limiting mechanisms. The proposal will study the application of different chemical surface treatments to 0.53 half-wave cavities, with the addition of low temperature bakes (LTB), and measure their effects on accelerating performance. Proposed chemical treatments to be explored in this proposal include conventional EP acid mixtures, as well as innovated EP and BCP acid mixtures designed to simplify processing paths in migrating FE and HFQS. The proposed transformative treatment wet N-doping also has the potential to replicate recent advancements in SRF technology relating to nitrogen doping and high Q operation without the requirement for an ultra-high vacuum annealing furnace; currently being developed at FNAL and JLAB. In parallel, high Q performance relating to flux trapping will be investigated with the installation of a second layer of magnetic shielding in the vertical test Dewar. The research objectives presented in the proposal, and their corresponding effects on cavity performance, will provide essential knowledge and future guidance to the SRF community and provide possible paths for future SRF based projects and applications.

43 PARTICLE ACCELERATORS↗

A system reliability analysis for stand-by spares with non-zero unpowered failure rates

Equations which define the reliability of n-fold parallel systems with stand-by spares, and triply redundant, majority-voting systems with stand-by spares have been derived. The stand-by spares have been assumed to have a non-zero failure rate while in the stand-by mode. A Monte Carlo system simulation has been generated and the results compared to the theoretical reliability predictions. A comparison of these two stand-by configurations is also presented for three through six total units.

Taylor, D. S.↗

Computation of spare parts requirements

Statistical analysis determines probability of failure for N-1 spares. Analysis can help reduce downtime in industrial processes by determining number of spare parts that must be stockpiled. Analysis can also be inverted to decide if number of spares on hand is sufficient for lifetime needs of system.

Mezzacappa, M. A.↗

Allocating Spare Parts In Complicated Systems

Assortments analyzed for cost effectiveness and effects on system functionality. Eisenberger-Maiocco algorithm (EMA) is efficient Markov algorithm to aid in provision of spare parts. Two calculations performed: forecasting availability of system with given pool of spare parts and determining most cost-effective assortment of spares. EMA written in interpreter PC-BASIC.

Eisenberger, I.↗

Spares quantification for the Space Shuttle Orbiters

A study to determine the numerous factors that must be considered and utilized to accurately quantify the number of spares necessary to support the Orbiter processing is presented. Previously the method used to quantify the requirements for spares was based on a probability of sufficiency (POS) equation. It was found that there are several categories of failures, not only the operating hour dependency type used in POS. Therefore, it was determined that various methods of quantifying spares should be utilized for the different categories of failures. Trending analysis of the failure history was deemed necessary. Also, the working environment was determined to be an important factor in the failure data.

Groh-Hammond, Marcia M.↗

Compact Spare-Row Decoder For Computer Memory

Spare-row memory-address-decoder circuit commanded to address ninth row in computer memory instead of addressing one of eight others it would address normally. Variants used to construct small, highly reliable computers. Spare-row decoder offers advantages of compactness, efficiency, and performance. Requires only 12.5 percent memory overhead. System equipped with spare-row decoder requires less glue logic and exhibits greater through-put. Applications include computers in Hitchhiker Central Unit embedded computer on Cassini spacecraft. Concept of circuit applicable to most flight computer systems.

Katz, Richard B.↗

Comparison of Spares Logistics Analysis Techniques for Long Duration Human Spaceflight

As the durations and distances involved in human exploration missions increase, the logistics associated with the repair and maintenance becomes more challenging. Whereas the operation of the International Space Station (ISS) depends upon regular resupply from the Earth, this paradigm may not be feasible for future missions. Longer mission durations result in higher probabilities of component failures as well as higher uncertainty regarding which components may fail, and longer distances from Earth increase the cost of resupply as well as the speed at which the crew can abort to Earth in the event of an emergency. As such, mission development efforts must take into account the logistics requirements associated with maintenance and spares. Accurate prediction of the spare parts demand for a given mission plan and how that demand changes as a result of changes to the system architecture enables full consideration of the lifecycle cost associated with different options. In this paper, we utilize a range of analysis techniques - Monte Carlo, semi-Markov, binomial, and heuristic - to examine the relationship between the mass of spares and probability of loss of function related to the Carbon Dioxide Removal System (CRS) for a notional, simplified mission profile. The Exploration Maintainability Analysis Tool (EMAT), developed at NASA Langley Research Center, is utilized for the Monte Carlo analysis. We discuss the implications of these results and the features and drawbacks of each method. In particular, we identify the limitations of heuristic methods for logistics analysis, and the additional insights provided by more in-depth techniques. We discuss the potential impact of system complexity on each technique, as well as their respective abilities to examine dynamic events. This work is the first step in an effort that will quantitatively examine how well these techniques handle increasingly more complex systems by gradually expanding the system boundary.

Owens, Andrew↗

Characterizing the impact of using spare-cores on application performance

Increased parallelism on a single processor is driving improvements in peak-performance at both the node and system levels. However achievable performance, in particular from production scientific applications, is not always directly proportional to the core count. Performance is often limited by constraints in the memory hierarchy and also by a node interconnectivity. Even on state-of-the-art processors, containing between four and eight cores, many applications cannot take full advantage of the compute-performance of all cores. This trend is expected to increase on future processors as the core count per processor increases. In this work we characterize the use of spare-cores, cores that do not provide any improvements in application performance, on current multi-core processors. By using a pulse-width modulation method, we examine the possible performance profile of using a spare-core and quantify under what situations its use will not impact application performance. We show that, for current AMD and Intel multi-core processors, spare-cores can be used for substantial computational tasks but can impact application performance when using shared caches or when significantly accessing main memory.

97 MATHEMATICS AND COMPUTING↗

Redundancy: How Many Unreliable Spares are Needed for High Reliability and Confidence?

This paper investigates the number of redundant units needed to achieve high reliability with high confidence. The approach is developed for the case when the system failure rate is too high for a single unit to provide the required reliability over the mission duration. To achieve high reliability, N redundant units can be used, one operating unit and N – 1 spares. If the unit failure rate is f, the mission length is L, and f * L is small (not the case assumed here), the unit failure probability over the mission duration is F1 = f * L << 1. In this case, the probability that all N units will fail is Ffail = F1 N , and the needed redundancy N = LN(F)/LN(F1). For the case of large f * L assumed here, F1 = f * L > 1, and F1 is the expected number of failures during the mission. (When F1 = f * L << 1, F1 is the probability that a unit will fail during the mission. When F1 = f * L > 1, F1 is the expected number of failures during the mission.) The needed redundancy, N, to achieve the required N redundant unit reliability, FN, can be computed using the cumulative Poisson distribution with mean equal to F1. The number of spares, N - 1, is increased until the probability - that the total number of failures will be less than N -1 - is equal to the required reliability. The confidence that this reliability can be achieved can be computed using the cumulative Poisson distribution or the chi-square distribution. Since the measured unit failure rate, f, has some probabilistic uncertainty, the actual failure rate will be randomly higher or lower. This means that the reliability of the N redundant systems will be overestimated about half the time. Adding more redundant units increases the confidence that the required reliability will be achieved. For a fixed number of redundant units, the expected reliability and confidence can be traded off, since lower reliability goals will be achieved with higher confidence. Both the desired reliability and confidence can be specified as initial requirements and the needed number of redundant units estimated using the measured failure rate.

Redundancy↗

Endovenous Laser Ablation of the Small Saphenous Vein Sparing the Saphenopopliteal Junction

To assess outcomes after endovenous laser ablation (EVLA) of the small saphenous vein (SSV). Retrospective review was performed of all consecutive EVLA procedures performed over a 39-month period at three neighboring vein practices for symptomatic, duplex ultrasound-proven incompetence of the SSV. EVLA was performed under ultrasound guidance with an 810- or 980-nm diode laser in continuous mode using the pullback method while sparing the deep, most cephalad segment of the SSV near the saphenopopliteal junction. Follow-up after EVLA included patient symptoms, physical examination, and duplex ultrasound. Pretreatment variables were similar across all three practices. EVLA was performed to treat 67 incompetent SSVs in 63 patients (86% women; mean age and 95% confidence interval, 50 {+-} 3 years; range, 20-82 years). Average energy delivered was 92 J/cm. Immediate technical success and occlusion of the treated vein at 1-2 weeks was 100%. Imaging follow-up length was 243 {+-} 65 days (range, 3-893 days). Clinical follow-up (243 {+-} 66 days) showed symptomatic improvement in 66 (99%) of 67 patients; one patient had recanalization with recurrent reflux by ultrasound (2%). Complications included one case of paresthesias lasting beyond 1 month of follow-up (2%) and three cases of superficial phlebitis (4%), but no deep vein thrombosis, skin burns, or other complications. Although ablation involved only the superficial portion of the SSV and spared its deep segment in the popliteal fossa, SSV occlusion typically extended up to the saphenopopliteal junction or to a gastrocnemial collateral, without popliteal vein involvement. EVLA of the SSV is safe and effective when the saphenopopliteal junction and popliteal fossa are avoided. This approach may help reduce the risk of paresthesias or other complications while maintaining low recanalization rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose-Effect Relationships for the Submandibular Salivary Glands and Implications for Their Sparing by Intensity Modulated Radiotherapy

Purpose: Submandibular salivary glands (SMGs) dysfunction contributes to xerostomia after radiotherapy (RT) of head-and-neck (HN) cancer. We assessed SMG dose-response relationships and their implications for sparing these glands by intensity-modulated radiotherapy (IMRT). Methods and Materials: A total of 148 HN cancer patients underwent unstimulated and stimulated SMG salivary flow rate measurements selectively from Wharton's duct orifices, before RT and periodically through 24 months after RT. Correlations of flow rates and mean SMG doses were modeled throughout all time points. IMRT replanning in 8 patients whose contralateral level I was not a target incorporated the results in a new cost function aiming to spare contralateral SMGs. Results: Stimulated SMG flow rates decreased exponentially by (1.2%){sup Gy} as mean doses increased up to 39 Gy threshold, and then plateaued near zero. At mean doses {<=}39 Gy, but not higher, flow rates recovered over time at 2.2%/month. Similarly, the unstimulated salivary flow rates decreased exponentially by (3%){sup Gy} as mean dose increased and recovered over time if mean dose was <39 Gy. IMRT replanning reduced mean contralateral SMG dose by average 12 Gy, achieving {<=}39 Gy in 5 of 8 patients, without target underdosing, increasing the mean doses to the parotid glands and swallowing structures by average 2-3 Gy. Conclusions: SMG salivary flow rates depended on mean dose with recovery over time up to a threshold of 39 Gy. Substantial SMG dose reduction to below this threshold and without target underdosing is feasible in some patients, at the expense of modestly higher doses to some other organs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Does Three-Dimensional External Beam Partial Breast Irradiation Spare Lung Tissue Compared With Standard Whole Breast Irradiation?

Purpose: To determine whether three-dimensional conformal partial breast irradiation (3D-PBI) spares lung tissue compared with whole breast irradiation (WBI) and to include the biologically equivalent dose (BED) to account for differences in fractionation. Methods and Materials: Radiotherapy treatment plans were devised for WBI and 3D-PBI for 25 consecutive patients randomized on the NSABP B-39/RTOG 0413 protocol at Mayo Clinic in Jacksonville, Florida. WBI plans were for 50 Gy in 25 fractions, and 3D-PBI plans were for 38.5 Gy in 10 fractions. Volume of ipsilateral lung receiving 2.5, 5, 10, and 20 Gy was recorded for each plan. The linear quadratic equation was used to calculate the corresponding dose delivered in 10 fractions and volume of ipsilateral lung receiving these doses was recorded for PBI plans. Ipsilateral mean lung dose was recorded for each plan and converted to BED. Results: There was a significant decrease in volume of lung receiving 20 Gy with PBI (median, 4.4% vs. 7.5%; p < 0.001), which remained after correction for fractionation (median, 5.6% vs. 7.5%; p = 0.02). Mean lung dose was lower for PBI (median, 3.46 Gy vs. 4.57 Gy; p = 0.005), although this difference lost significance after conversion to BED (median, 3.86 Gy{sub 3} vs 4.85 Gy{sub 3}, p = 0.07). PBI plans exposed more lung to 2.5 and 5 Gy. Conclusions: 3D-PBI exposes greater volumes of lung tissue to low doses of radiation and spares the amount of lung receiving higher doses when compared with WBI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Geometrical Sparing Factors for the Rectum and Bladder in the Prediction of Grade 2 and Higher Complications After High-Dose-Rate Brachytherapy for Cervical Cancer

Purpose: This study aimed to assess the predictive values of geometrical sparing factors for the rectum and bladder in high-dose-rate intracavitary brachytherapy (HDRICB) for Grade 2 and higher late sequelae in patients with cervical cancer. Methods: A total of 392 patients were enrolled in this study. They were treated with external beam radiotherapy to the pelvis, after which HDRICB was performed using Ir-192 remote after-loading at 1-week intervals for three or four sessions. The geometrical sparing factor (GSF) was defined as the average of the ratios between the reference doses and the Point A dose. Results: A total of 46 patients (11.7%) had Grade 2 or higher late rectal complications (36 Grade 2, 9 Grade 3, and 1 Grade 4). In all, 32 patients (8.2%) had Grade 2 or higher late bladder complications (14 Grade 2, 16 Grade 3, and 2 Grade 4). Multivariate analysis demonstrated a high risk of rectal sequelae in patients who developed bladder complications (p = 0.0004, hazard ratio 3.54) and had a rectal GSF greater than 0.7 (p = 0.01, hazard ratio 1.99). The high risk factors for bladder complications were development of rectal complications (p = 0.0004, hazard ratio 3.74), concurrent chemotherapy (p = 0.0001, relative risk 3.94), and a bladder GSF greater than 0.9 (p = 0.01, hazard ratio, 2.53). Conclusion: This study demonstrates the predictive value of GSFs in HDRICB for cervical cancer. Patients with rectal GSFs greater than 0.7 or bladder GSFs greater than 0.9 are at risk for Grade 2 and higher late sequelae.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Comparison of Involved-Field Three-Dimensional Conformal Photon Radiotherapy and Breast-Sparing Proton Therapy for the Treatment of Hodgkin's Lymphoma in Female Pediatric Patients

Purpose: To assess the potential reduction in breast dose for young girls with Hodgkin's lymphoma (HL) treated with breast-sparing proton therapy (BS-PT) as compared with three-dimensional conformal involved-field photon radiotherapy (3D-CRT). Methods and Materials: The Clarian Health Cancer Registry was queried for female pediatric patients with the diagnosis of HL who received radiotherapy at the Indiana University Simon Cancer Center during 2006-2009. The original CT simulation images were obtained, and 3D-CRT and BS-PT plans delivering 21 Gy or cobalt gray equivalent (CGE) in 14 fractions were created for each patient. Dose-volume histogram data were collected for both 3D-CRT and BS-PT plans and compared by paired t test for correlated samples. Results: The cancer registry provided 10 female patients with Ann Arbor Stage II HL, aged 10-18 years at the time of treatment. Both mean and maximum breast dose were significantly less with BS-PT compared with 3D-CRT: 0.95 CGE vs. 4.70 Gy (p < 0.001) and 21.07 CGE vs. 23.11 Gy (p < 0.001), respectively. The volume of breast receiving 1.0 Gy/CGE and 5.0 Gy/CGE was also significantly less with BS-PT, 194 cm{sup 3} and 93 cm{sup 3}, respectively, compared with 790 cm{sup 3} and 360 cm{sup 3} with 3D-CRT (p = 0.009, 0.013). Conclusion: Breast-sparing proton therapy has the potential to reduce unnecessary breast dose in young girls with HL by as much as 80% relative to involved-field 3D-CRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Urethra-Sparing, Intraoperative, Real-Time Planned, Permanent-Seed Prostate Brachytherapy: Toxicity Analysis

Purpose: To report the toxicity outcome in patients with localized prostate cancer undergoing {sup 125}I permanent-seed brachytherapy (BT) according to a urethra-sparing, intraoperative (IO), real-time planned conformal technique. Methods and Materials: Data were analyzed on 250 patients treated consecutively for low- or intermediate-risk prostate cancer between 2005 and 2009. The planned goal was urethral V{sub 150} = 0. Acute and late genitourinary (GU), gastrointestinal (GI), and erectile toxicities were scored with the International Prostate Symptom Score (IPSS) questionnaire and Common Terminology Criteria for Adverse Events (version 3.0). Median follow-up time for patients with at least 2 years of follow-up (n = 130) was 34.4 months (range, 24-56.9 months). Results: Mean IO urethra V{sub 150} was 0.018% {+-} 0.08%. Mean prostate D{sub 90} and V{sub 100} on day-30 computed tomography scan were 158.0 {+-} 27.0 Gy and 92.1% {+-} 7.2%, respectively. Mean IPSS peak was 9.5 {+-} 6.3 1 month after BT (mean difference from baseline IPSS, 5.3). No acute GI toxicity was observed in 86.8% of patients. The 3-year probability of Grade {>=}2 late GU toxicity-free survival was 77.4% {+-} 4.0%, with Grade 3 late GU toxicity encountered in only 3 patients. Three-year Grade 1 late GI toxicity-free survival was 86.1% {+-} 3.2%. No patient presented Grade {>=}2 late GI toxicity. Of patients with normal sexual status at baseline, 20.7% manifested Grade {>=}2 erectile dysfunction after BT. On multivariate analysis, elevated baseline IPSS (p = 0.016) and high-activity sources (median 0.61 mCi) (p = 0.033) predicted increased Grade {>=}2 late GU toxicity. Conclusions: Urethra-sparing IO BT results in low acute and late GU toxicity compared with the literature. High seed activity and elevated IPSS at baseline increased long-term GU toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Using a Reduced Spot Size for Intensity-Modulated Proton Therapy Potentially Improves Salivary Gland-Sparing in Oropharyngeal Cancer

Purpose: To investigate whether intensity-modulated proton therapy with a reduced spot size (rsIMPT) could further reduce the parotid and submandibular gland dose compared with previously calculated IMPT plans with a larger spot size. In addition, it was investigated whether the obtained dose reductions would theoretically translate into a reduction of normal tissue complication probabilities (NTCPs). Methods: Ten patients with N0 oropharyngeal cancer were included in a comparative treatment planning study. Both IMPT plans delivered simultaneously 70 Gy to the boost planning target volume (PTV) and 54 Gy to the elective nodal PTV. IMPT and rsIMPT used identical three-field beam arrangements. In the IMPT plans, the parotid and submandibular salivary glands were spared as much as possible. rsIMPT plans used identical dose-volume objectives for the parotid glands as those used by the IMPT plans, whereas the objectives for the submandibular glands were tightened further. NTCPs were calculated for salivary dysfunction and xerostomia. Results: Target coverage was similar for both IMPT techniques, whereas rsIMPT clearly improved target conformity. The mean doses in the parotid glands and submandibular glands were significantly lower for three-field rsIMPT (14.7 Gy and 46.9 Gy, respectively) than for three-field IMPT (16.8 Gy and 54.6 Gy, respectively). Hence, rsIMPT significantly reduced the NTCP of patient-rated xerostomia and parotid and contralateral submandibular salivary flow dysfunction (27%, 17%, and 43% respectively) compared with IMPT (39%, 20%, and 79%, respectively). In addition, mean dose values in the sublingual glands, the soft palate and oral cavity were also decreased. Obtained dose and NTCP reductions varied per patient. Conclusions: rsIMPT improved sparing of the salivary glands and reduced NTCP for xerostomia and parotid and submandibular salivary dysfunction, while maintaining similar target coverage results. It is expected that rsIMPT improves quality of life during and after radiotherapy treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Monitoring Dosimetric Impact of Weight Loss With Kilovoltage (KV) Cone Beam CT (CBCT) During Parotid-Sparing IMRT and Concurrent Chemotherapy

Purpose: Parotid-sparing head-and-neck intensity-modulated radiotherapy (IMRT) can reduce long-term xerostomia. However, patients frequently experience weight loss and tumor shrinkage during treatment. We evaluate the use of kilovoltage (kV) cone beam computed tomography (CBCT) for dose monitoring and examine if the dosimetric impact of such changes on the parotid and critical neural structures warrants replanning during treatment. Methods and materials: Ten patients with locally advanced oropharyngeal cancer were treated with contralateral parotid-sparing IMRT concurrently with platinum-based chemotherapy. Mean doses of 65 Gy and 54 Gy were delivered to clinical target volume (CTV)1 and CTV2, respectively, in 30 daily fractions. CBCT was prospectively acquired weekly. Each CBCT was coregistered with the planned isocenter. The spinal cord, brainstem, parotids, larynx, and oral cavity were outlined on each CBCT. Dose distributions were recalculated on the CBCT after correcting the gray scale to provide accurate Hounsfield calibration, using the original IMRT plan configuration. Results: Planned contralateral parotid mean doses were not significantly different to those delivered during treatment (p > 0.1). Ipsilateral and contralateral parotids showed a mean reduction in volume of 29.7% and 28.4%, respectively. There was no significant difference between planned and delivered maximum dose to the brainstem (p = 0.6) or spinal cord (p = 0.2), mean dose to larynx (p = 0.5) and oral cavity (p = 0.8). End-of-treatment mean weight loss was 7.5 kg (8.8% of baseline weight). Despite a {>=}10% weight loss in 5 patients, there was no significant dosimetric change affecting the contralateral parotid and neural structures. Conclusions: Although patient weight loss and parotid volume shrinkage was observed, overall, there was no significant excess dose to the organs at risk. No replanning was felt necessary for this patient cohort, but a larger patient sample will be investigated to further confirm these results. Nevertheless, kilovoltage CBCT is a valuable tool for patient setup verification and monitoring of dosimetric variation during radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗