Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Solar tracker”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Aeroelastic Modeling and Full-Scale Loads Measurements for Investigation of Single-Axis PV Tracker Wind-Driven Dynamic Instabilities

While wind tunnel testing and proprietary industry modeling tools have been used for years to design and develop PV tracker systems, wind induced dynamic failures are becoming more prevalent and high visibility. Designers and manufactures have reacted by developing new systems or add-on products to improve system dynamics adding to overall system costs. To better understand the physics and aeroelastic behavior that leads to dynamic instabilities NREL researches have taken up a first of a kind study to both develop open source aeroelastic modeling tools and measure tracker loads on a single axis full-scale tracker system at a high wind site. These modeling tools can simulate the fluid-structure interaction driving torsional instabilities under a wide range of turbulent inflow conditions and stow angles. The results of these simulations reveal the flow features associated with panel rotation and the induced loads in the structure. The experimental load measurements can be used to validate models and provide a quantifiable understanding of tracker dynamics, critical loads paths, identify instability markers, inform resilient design, and suggest the most favorable stow approach.

14 SOLAR ENERGY↗

A methodology to analyze photovoltaic tracker uptime

A metric is developed to analyze the daily performance of single-axis photovoltaic (PV) trackers. The metric relies on comparing correlations between the daily time series of the PV power output and an array of simulated plane-of-array irradiances for the given day. Mathematical thresholds and a logic sequence are presented, so the daily tracking metric can be applied in an automated fashion on large-scale PV systems. The results of applying the metric are visually examined against the time series of the power output data for a large number of days and for various systems. The visual inspection results suggest that overall, the algorithm is accurate in identifying stuck or functioning trackers on clear-sky days. Visual inspection also shows that there are days that are not classified by the metric where the power output data may be sufficient to identify a stuck tracker. Based on the daily tracking metric, uptime results are calculated for 83 different inverters at 34 PV sites. The mean tracker uptime is calculated at 99% based on 2 different calculation methods. The daily tracking metric clearly has limitations, but as there is no existing metrics in the literature, it provides a valuable tool for flagging stuck trackers.

14 SOLAR ENERGY↗

Concentrating Solar Panels: Bringing the Highest Power and Lowest Cost to the Rooftop

Soliant Energy is a venture-capital-backed startup focused on bringing advanced concentrating solar panels to market. Our fundamental innovation is that we are the first company to develop a racking solar concentrator specifically for commercial rooftop applications, resulting in the lowest LCOE for rooftop electricity generation. Today, the commercial rooftop segment is the largest and fastest-growing market in the solar industry. Our concentrating panels can make a major contribution to the SAI's objectives: reducing the cost of solar electricity and rapidly deploying capacity. Our commercialization focus was re-shaped in 2009, shifting from an emphasis solely on panel efficiency to LCOE. Since the inception of the SAI program, LCOE has become the de facto standard for comparing commercial photovoltaic systems. While estimation and prediction models still differ, the emergence of performance-based incentive (PBI) and feed-in tariff (FIT) systems, as well as power purchase agreement (PPA) financing structures make LCOE the natural metric for photovoltaic systems. Soliant Energy has designed and demonstrated lower-cost, higher-power solar panels that consists of 6 (500X) PV module assemblies utilizing multi-junction cells and an integrated two-axis tracker. In addition, we have designed and demonstrated a prototype 1000X panel assembly with 8. Cost reductions relative to conventional flat panel PV systems were realized by (1) reducing the amount of costly semiconductor material and (2) developing strategies and processes to reduce the manufacturing costs of the entire system. Performance gains against conventional benchmarks were realized with (1) two-axis tracking and (2) higher-efficiency multi-junction PV cells capable of operating at a solar concentration ratio of 1000X (1000 kW/m2). The program objectives are: (1) Develop a tracking/concentrating solar module that has the same geometric form factor as a conventional flat, roof mounted photovoltaic (PV) panel - the Soliant module will produce more power and cost less than conventional panels of the same size; (2) Target LCOE: $0.079/kWh in 2010; (3) Target efficiency - 26% in 2010 (22% for 2008 prototype, 24% for 2009 pilot); and (4) Target performance - equivalent to 650Wp in 2010 (490W for 2008 prototype, 540W for 2009 pilot).

14 SOLAR ENERGY↗

A Method for Estimating Time-Series PV Production Loss From Solar Tracking Failures

Solar tracking system failures can dramatically reduce photovoltaic (PV) system energy output through suboptimal irradiance capture and self-shading loss. Detecting tracker failures is not always straightforward; unlike other common PV system failures like inverter outages and blown fuses which take portions of a system completely offline, tracker failures only partially reduce output power and can go unnoticed as a result. Additionally, tracker failures can take one of several forms, each with their own loss characteristics. Here we present two methods of detecting tracker failure events from time-series production data and a method for estimating the associated production loss. Compared with existing detection methods, the proposed power-based detection method showed 0-17% reductions in Type I error rate depending on weather conditions. Here, the loss model estimated production loss with low error (mean bias error = -2.3 %, root-mean-squared error = 6%) in a rudimentary validation.

14 SOLAR ENERGY↗

Bifacial PV Module Energy Modeling Validation Study

The cost delta between monofacial and bifacial photovoltaic (PV) modules was decreasing in 2018 when this study was initially proposed, making bifacial modules an attractive offering. However, there were limited field studies available that could be considered utility-scale representative, and PV module manufacturers were stating large ranges for the expected energy yield improvements of bifacial technology. This generated uncertainties regarding bifacial performance gains and the actual LCOE (levelized cost of energy). There was also relatively low confidence in the industry’s energy modeling tools’ ability to accurately predict bifacial energy yield, meaning that early adopters of bifacial modules were not able to fully account for the increased energy yield in their energy and financial models. The intent of this project was to provide the solar industry with greater certainty on the energy yield gains of bifacial modules and provide higher confidence in the ability for different energy modeling software to model bifacial PV site performance. Achieving this would allow for bifacial technology to become bankable (i.e. accepted by Independent Engineers, site financiers and other PV site stakeholders), offering a step change in PV site performance that had not been seen since the widespread adoption of the single-axis tracker. Over the course of this study other economic factors including a significant tariff exemption for bifacial modules resulted in accelerated adoption of bifacial technology throughout the US utility scale solar segment. The number of early adopters increased rapidly, and with many investors accepting this module choice the question of bifacial bankability was seemingly answered faster than expected. However, PVEL’s study has still achieved significant accomplishments in demonstrating the accuracy of bifacial modeling across three different software platforms. The results of this study have shown that the mean biased error (MBE) between the field data and the predicted values from all three software platforms were aligned with a maximum MBE of 1.3% and a minimum MBE of -1.8%.

14 SOLAR ENERGY↗

Single-Axis Tracker Control Optimization Potential for the Contiguous United States

Conventional tracker control algorithms maximize collection of direct irradiance with no regard for collection of diffuse irradiance. Therefore, a tracker control algorithm that optimizes for maximal total irradiance, not just direct, might realize improved insolation collection. Using weather data gridded at 0.25° by 0.25° latitude/longitude spacing covering the contiguous United States, we evaluate the insolation gain of two alternative control algorithms optimized for improved total irradiance collection in monofacial arrays and present annual and monthly geographic heatmaps showing the gains across the contiguous United States. Certain locations show potential annual insolation gains approaching 1.0%, but most locations with recently-built tracker systems show annual gains between 0.1% and 0.4%. We also demonstrate a relationship between a climate's annualized diffuse insolation fraction and its potential tracker optimization insolation gain.

diffuse↗

A Multilevel DC to Three-phase AC Architecture for Photovoltaic Power Plants

This study presents a photovoltaic (PV) inverter architecture composed of stackable dc to three-phase ac converter blocks. Several such blocks, each containing a converter power stage and controls, are connected in series on their ac sides to obtain transformerless medium-voltage ac interfaces for PV power plants. The series-connected structure is made possible by a quadruple active bridge dc-dc converter that provides isolation between the PV input and each of the three ac-side phases within each block. Furthermore, since incoming PV power is transferred as constant balanced three-phase ac power, instantaneous inputoutput power balance bypasses the need for bulk energy storage. To streamline implementation and maximize system scalability and resilience, decentralized block-level controllers accomplish dc-link voltage regulation, maximum power point tracking, and ac-side power sharing without centralized means. The proposed architecture is validated by simulations of a PV string to mediumvoltage ac system consisting of six blocks and on a proof-of-concept hardware prototype that consists of three cascaded converter blocks.

14 SOLAR ENERGY↗

Analysis of the Solar Energy Collection for In-Plane Rotation Two Axes Micro-Tracking Systems

Concentrator photovoltaic technologies (CPV) have long been regarded as the obvious way to increase the solar power collection efficiency but the use of bulky two axes tracking systems has been proven to be a fatal handicap for both economic and technical reasons. On the other hand, the continuous development of multijunction high efficiency solar cells encourages the research of novel CPV architectures that can leverage the new cells potential. Here we present a study on the solar energy collection of an ideal hybrid two axes micro-tracking system suitable for rooftop installations. In this study, we analyze in detail the optimal installation angle in relation to the latitude and the partial shading effect on modules of the same solar panel. The study is focused on optimizing the average collection efficiency over the astronomical year period as opposed to maximize the collection on any given day of the year. Additionally, we conducted a techno-economic analysis of the hybrid In-Plane Micro Tracker, using “Bottom-Up” methodology for determining the cost of the micro-tracking concept where the materials, assembly, utilities, maintenance costs are included for each step of the manufacturing process.

14 SOLAR ENERGY↗

Combined heat and power generation with a HCPV system at 2000 suns

This work shows the development of an innovative solar CHP system for the combined production of heat and power based upon HCPV modules working at the high concentration level of 2000 suns. The solar radiation is concentrated on commercial InGaP/InGaAs/Ge triple-junction solar cells designed for intensive work. The primary optics is a rectangular off-axis parabolic mirror while a secondary optic at the focus of the parabolic mirror is glued in optical contact with the cell. Each module consist of 2 axis tracker (Alt-Alt type) with 20 multijunction cells each one integrated with an active heat sink. The cell is connected to an active heat transfer system that allows to keep the cell at a high level of electrical efficiency (ηel > 30 %), bringing the heat transfer fluid (water and glycol) up to an output temperature of 90°C. Accordingly with the experimental data collected from the first 1 kWe prototype, the total amount of extracted thermal energy is above the 50% of the harvested solar radiation. That, in addition the electrical efficiency of the system contributes to reach an overall CHP efficiency of more than the 80%.

14 SOLAR ENERGY↗

PV Reliability Lessons from 100,000 Systems

Despite the importance of reliability to the cost competitiveness of PV, large data sets enabling high-level investigation of the technology’s performance in the field are relatively scarce. Dirk C. Jordan, Chris Deline, Bill Marion and Teresa Barnes of the National Renewable Energy Laboratory, and Mark Bolinger of the Lawrence Berkeley National Laboratory study a unique data set of 100,000 PV systems in the US, drawing out tips for better reliability that have relevance to other parts of the world.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Single-Axis Tracker Control Optimization Potential for the Contiguous United States: Preprint

Conventional tracker control algorithms maximize collection of direct irradiance with no regard for collection of diffuse irradiance. Therefore, a tracker control algorithm that optimizes for maximal total irradiance, not just direct, might realize improved insolation collection. Using weather data gridded at 0.25° by 0.25° latitude/longitude spacing covering the contiguous United States, we evaluate the insolation gain of two alternative control algorithms optimized for improved total irradiance collection in monofacial arrays and present annual and monthly geographic heatmaps showing the gains across the contiguous United States. Certain locations show potential annual insolation gains approaching 1.0%, but most locations with recently-built tracker systems show annual gains between 0.1% and 0.4%. We also demonstrate a relationship between a climate's annualized diffuse insolation fraction and its potential tracker optimization insolation gain.

diffuse↗

Rotation Angle for the Optimum Tracking of One-Axis Trackers

An equation for the rotation angle for optimum tracking of one-axis trackers is derived along with equations giving the relationships between the rotation angle and the surface tilt and azimuth angles. These equations are useful for improved modeling of the solar radiation available to a collector with tracking constraints and for determining the appropriate motor revolutions for optimum tracking.

14 SOLAR ENERGY↗

Final Technical Report for Automated Manufacturing of Innovative CPV/PV Modules

Cogenra’s Dense Cell Interconnect system was designed to use traditional front-contact cells and string them together into high efficiency and high reliability “supercells”. This novel stringer allows one to take advantage of the ~100 GW/year of existing cell production capacity and create a solar product for the customer that will produce more power and last longer than traditional PV products. The goal for this program was for Cogenra Solar to design and develop a first-of-kind automated solar manufacturing line that produces strings of overlapping cells or “supercells” based on Cogenra’s Dense Cell Interconnect (DCI) technology for their Low Concentration Photovoltaic (LCPV) systems. This will enable the commercialization of DCI technology to improve the efficiency, reliability and economics for their Low Concentration Photovoltaic systems. In this program, Cogenra Solar very successfully designed, developed, built, installed, and started up the ground-breaking manufacturing tools required to assemble supercells. Cogenra then successfully demonstrated operation of the integrated line at high yield and throughput far exceeding expectations. The development of a supercell production line represents a critical step toward a high volume and low cost Low Concentration Photovoltaic Module with Dense Cell Interconnect technology and has enabled the evaluation of the technology for reliability and yield. Unfortunately, performance and cost headwinds on Low Concentration Photovoltaics systems including lack of diffuse capture (10-15% hit) and more expensive tracker requirements resulted in a move away from LCPV technology. Fortunately, the versatility of Dense Cell Interconnect technology allows for application to flat plate module technology as well and Cogenra has worked with the DOE to utilize the learning from this grant to commercialize DCI technology for the solar market through the on-going grant: Catalyzing PV Manufacturing in the US With Cogenra Solar’s Next-Generation Dense Cell Interconnect PV Module Manufacturing Technology. This program is now very successfully building off of this work and commercializing the technology to enable increased solar adoption.

14 SOLAR ENERGY↗

Assessing the Optical Performance Impact of Tracking Error in an Operational Concentrated Solar Power Plant Using Monte Carlo Ray-Tracing Simulation

Concentrating Solar Power (CSP) provides firm and dispatchable electricity due to its thermal storage and hybridization capabilities, which supports the decarbonization of our energy supply. Of the various CSP technologies, parabolic trough collectors are the most mature, with over 500 MW operating worldwide. The optical performance of parabolic trough systems is sensitive to tracking error, which is defined as the angular offset of a collector away from the sun position in the transversal plane. Tracking error commonly occurs due to non-continuous adjustment of the trough angle to point toward the sun, but other factors such as gravity, heating, and wind loading can also contribute to tracking error. Researchers have explored the impact of tracking error on optical performance both numerically and experimentally, but existing studies do not include measurements from operational utility-scale power plants. Tilt angle measurements of parabolic troughs at operational utility-scale power plants illustrate spatial variations in optical performance and include various sources of tracking error such as gravity, heating, and wind loading. To fully characterize wind driven loads on parabolic troughs, we are conducting a long-term field measurement campaign at the Nevada Solar One CSP plant located in Boulder City, NV, which has a nominal capacity of 72 MW and 0.5 hours of full-load storage. We record load measurements on four outer trough rows, collecting support structure bending moments, drive torque moments, dynamic accelerations of the spaceframe, mirror displacement, and tilt angles. Using the tilt measurements acquired at 20 Hz frequency, we calculate the deviation between the nominal sun position and the tracker angle. Using a Monte-Carlo ray-tracing simulation software, we assess the impact of the tracker angle deviation on optical performance throughout the diurnal cycle at various spatial locations within the CSP plant. In our view, this first-of-a-kind study will provide important guidance for future trough designs that reduce the impact of various sources of tracking error on performance.

concentrating solar power↗

Model and Validation of Single-Axis Tracking with Bifacial Photovoltaics: Preprint

Single-axis tracking is a cost effective deployment strategy for large-scale ground-mount photovoltaic (PV) systems in regions with high direct-normal irradiance (DNI). Bifacial modules in 1-axis tracking systems boost energy yield by 4% - 15% depending on module type and ground albedo, with a global average of 9%. This benefit is in addition to the 15%-25% energy gain already afforded by single-axis tracking relative to fixed-tilt deployments. Here we compare model results against field performance data for two side-by-side bifacial / monofacial tracked systems - one in Albuquerque NM, and one in eastern Oregon. The Albuquerque system shows monthly rear irradiance gain of 10-14.9%, and the Oregon bifacial system has an average performance ratio 9.4% higher than the monofacial system. Both results match bifacial irradiance model results within uncertainty. Simulations show that smart tracking algorithms can offer more than 1% improvement on annual energy yield by adjusting tilt angle under cloudy conditions. Finally, ray-tracing simulations investigated edge brightening, suggesting 15%-25% increase in rear irradiance at the ends of tracker rows, but up to 20% loss from center-mounted torque tubes, creating multiple shadows.

14 SOLAR ENERGY↗

A High Efficiency DC-DC Converter Topology Suitable for Distributed Large Commercial and Utility Scale PV Systems

In this paper a DC-DC power converter for distributed photovoltaic plant architectures is presented. The proposed converter has the advantages of simplicity, high efficiency, and low cost. High efficiency is achieved by having a portion of the input PV power directly fed forward to the output without being processed by the converter. The operation of this converter also allows for a simplified maximum power point tracker design using fewer measurements

14 SOLAR ENERGY↗