Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Smart Labs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Application of Flux Conserved Modeling to an Unsteady Combustion Driven Pseudo-Shock

Quasi-steady correlation-based and flux conserved models of the pseudo-shock pressure profile are experimentally assessed in the Air Force Research Lab RC-18 Sub-Scale DirectConnect Isolator Combustion Facility. A bifurcated normal pseudo-shock is established in the 2.67 aspect ratio isolator test section by a downstream cavity-stabilized combustor. The Waltrup-Billig correlation, Smart flux conserved model, and Fiévet data driven flux conserved models are compared against measured pressure profiles. The literature models are found to perform poorly in a high-amplitude forced environment of RC-18, where shock speeds upwards of 20% the isolator Mach number occur. Two modifications to the quasi-steady Fiévet data driven flux conserved model are proposed including incorporating an estimate of pseudo-shock static pressure recovery and exercising the model in a shock stationary reference frame. It is shown that these modifications allow the quasi-steady flux conserved modeling approach to accurately predict pseudo-shock pressure profiles over the discrete phases of high-amplitude forced dynamics.

Shock Train↗

Introducing the 9500 Node Distribution Test System to Support Advanced Power Applications: An Operations-Focused Approach

The 9500 Node Test System is a representative section of distribution power system model developed as a part of the GridAPPS-D™ project, an effort funded by DOE as a part of the Grid Modernization Lab Consortium (GMLC) program. The test system was developed to fulfill a growing need to represent the rapidly evolving state of electric distribution systems by combining elements of legacy infrastructure systems, modern feeder topologies, and an anticipated future with smart grid technologies. It also provides a network model capable of supporting the simulation of operational scenarios such as the ones in a utility distribution control center. This test system allows the evaluation of the performance of advanced power applications in real-time, such as one that simulates the operations of an Advanced Distribution Management Systems (ADMS), Distributed Energy Resource Management Systems (DERMS), etc. in a Distribution control center. This model is an extension of the widely used IEEE 8500 Node Test Feeder and is currently being validated to become an IEEE test case to help increase adoption and widespread usage among both academia and industry. It is a full-size model representative of a section of a utility’s distribution system with multiple feeders fed from different substations. The model includes multiple distribution circuits, a sub-transmission system, multiple substations, behind the meter customer rooftop photovoltaics (PV), and multiple utility-scale distributed energy resources. To enable accurate simulations of operational scenarios, the 9500 Node Test System is designed to support procedure-based operations, with the ability to realistically demonstrate switching operations, feeder reconfiguration, adjustment of volt-var control equipment, dispatch of distributed generation, and response to planned and unplanned outages. The 9500 Node Test System includes three radial distribution feeders with 12.3 MVA of average load, consisting of both medium voltage and low voltage equipment each supplied by a different distribution substation. The three distribution feeders are connected to each other through Normally-Open switches which can be closed when needed to simulate restoration scenarios due to a fault. One feeder represents today’s grid with low penetration of customer-side renewables. The second represents a potential future grid with microgrids and 100% renewable penetration. The third has no customer generation resources, a district steam plant, and a utility-scale solar farm. The three diverse circuits were created to allow the simulation of both today’s situation as well as potential future scenarios. All three feeders have customers connected by low-voltage secondary triplex lines. This test system meets all requirements outlined in the report for creating a simulation environment that would enable discussion between key technical stakeholders as well as having the potential to accelerate operational application development and their subsequent testing and integration. The new model is a possible representation of what we believe the distribution grid may look like in the future: a high penetration of renewables, reconfigurable radial and mesh topology, numerous DERs, islanded microgrids, and significantly increased data and measurement density. The system supports both the solution of existing and newer algorithms but also enables the evaluation of applications in a realistic operational environment defined by task oriented procedural steps that represent the interaction between the control center operator and field personnel.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advance Distribution Management System (ADMS)

This presentation explores the transition from traditional distribution management systems to Advanced Distribution Management Systems (ADMS) as a foundation for smart grid development. It highlights the key benefits of ADMS, including enhanced reliability, improved operational efficiency, and increased situational awareness. The presentation also addresses common implementation challenges such as system integration, data management, and organizational readiness. It concludes with a forward-looking perspective on the evolving role of ADMS and essential takeaways for utilities and stakeholders.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Smart Contracts for Power Grid Applications Using the Advanced DLT Cyber Grid Guard Testbed

In this study is presented two power system applications with distributed ledger technology (DLT) and smart contracts (SC) that were assessed in a Cyber-Grid-Guard System (CGGS) advanced testbed, with protective relays, power meters, communication devices, DLT devices, synchronized time source, clock displays and real time simulator. This CGGS testbed was set in the Advanced Protection Lab, 252 lab space of the Grid Research Integration and Deployment Center (GRID- C), at Oak Ridge National Laboratory. In power grids, customer-owned distributed energy resources (DERs) are more frequent than in the past, and the numbers of points of interconnection (POI) with customer-owned DERs have increased. Disruptive operation from DERs presents a risk to grid operations, and protective relays located at the POI are used to isolate out-of-tolerance or poorly behaving of DERs. Ensuring the integrity of data from the relays at the POI, and DLT could enhance the security of the power grids. The first application is a SC to define and control the allowable total power factor (TPF) of the DER (wind farm) output, and the terms of the SC are implemented using DLT with a CGGS for a customer-owned DER. The TPF SC was implemented by the CGGS using DLT. The experimental model was performed with a real-time simulator using a CGGS and relay in-the-loop. The data collected from the CGGS were used to execute the TPF SC. The TPF limits were between +0.9 and +1.0, and the breakers’ operation in the POI was controlled by the relay using the SC. The events were collected from the real-time simulator, CGGS, and SEL 700GT relay to validate a successful application of the TPF SC using DLT. The second application is a SC to measure and control the allowable voltage service limits (VSL) by the CGGS using DLT. The tests were performed by using a real-time simulator, CGGS and relay in-the-loop. The data was collected from the CGGS that executed the SC. The main constraints were defined based on ANSI C84.1 service voltage limits, and the operation of the breakers in the POI. The events were collected from the CGGS, and SEL 700GT relay to assess a successful operation of the VSL SC using DLT.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Deep Generative Models in Energy System Applications: Review, Challenges, and Future Directions

In recent years, with the advent of mature machine learning products like ChatGPT, Stable Diffusion, and Sora, the world has witnessed tremendous changes driven by the rapid development of generative artificial intelligence (GAI). Beyond applications in text, speech, image, and video creation, deep generative models (DGMs) underpinning these cutting-edge technologies have also been employed by domain researchers to address scientific and engineering challenges. This paper aims to fill a gap in the research community by providing a systematic review of how DGMs have been utilized in energy system applications. After introducing four most popular DGMs, we review and categorize 196 research articles into five focus areas: data generation, forecasting, situational awareness, modeling, and optimal decision-making. Through this classification, we uncover trends in how DGMs are employed for each type of problem, highlighting GAI techniques that contribute to breakthroughs over traditional methods. We discuss limitations in existing literature, engineering challenges, and propose future directions, all tailored to the unique nature of problems in energy system engineering. Our goal is to offer insights for energy system domain researchers, providing a comprehensive view of existing studies and potential future opportunities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Virtual Power Plants and Distributed Energy Resource Management Systems

Virtual Power Plants (VPPs) are aggregations of DERs that can balance electrical loads and provide utility-scale and utility-grade grid services like a traditional power plant. This presentation covers VPP definition, State-of-the-Art, Grid Architectures, Example VPP studies, VPP Standards, and VPP Roadmap.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Center Director's Discretionary Fund 2005 Annual Report

The FY 2005 CDDF projects were selected from the following spaceport and range technology and science areas: fluid system technologies; spaceport structures and materials; command, control, and monitoring technologies; and biological sciences (including support for environmental stewardship). The FY 2005 CDDF research projects involved development of the following: a) Capacitance-based moisture sensors to optimize plant growth in reduced gravity; b) Commodity-free calibration methods; c) Application of atmospheric plasma glow discharge to alter the surface properties of polymers for improved electrostatic dissipation characteristics; d) A wipe-on, wipe-off chemical process to remove lead oxides found in paint; e) A robust metabolite profiling platform for better understanding the "law" of biological regulation; f) An explanation of the excavation processes that occur when a jet of gas impinges on a bed of sand; g) "Smart coatings" to detect and control corrosion at an early stage to prevent further corrosion h) A model that can produce a reliable diagnosis of the quality of a software product; i) The formulation of advanced materials to meet system safety needs to minimize electrostatic charges, flammability, and radiation exposure; j) A lab-based instrument that uses the electro-optic Pockels effect to make static electric fields visible; k) A passive volatile organic compound (VOC) cartridge to filter, identify, and quantify VOCs flowing into or emanating from plant flight experiments.

Nurge, Mark↗

Evaluation of Centralized Model Based FLISR in a Lab Setup

Utilities are installing advanced distribution management systems (ADMS) around the globe to improve the sensing and control of distribution systems. ADMS is becoming a critical component to improve the resiliency and reliability of distribution systems. These management systems host a multitude of applications that can be used to sense, control, and operate distribution systems. Fault location, isolation, and service restoration (FLISR) is one of the ADMS applications that is critical to improving resilience during fault conditions. FLISR applications use smart, controllable devices that are installed in the distribution system for FLISR operation. These controllable devices include distributed energy resources (DER) and reclosers. Evaluating such ADMS applications before installation in the field can help de-risk the field implementation and avoid costly failures in the field. This paper presents a background on experimental setup that are typically used to evaluate ADMS applications. This is followed by briefly presenting the setup used to evaluate the FLISR application in an off-the-shelf ADMS tool. Finally, results from the evaluation experiments are presented.

94 GMLC - Grid Modernization Laboratory Consortium↗

Evaluation of Centralized Model-Based FLISR in a Lab Setup: Preprint

Utilities are installing advanced distribution management systems (ADMS) around the globe to improve the sensing and control of distribution systems. ADMS is becoming a critical component to improve the resiliency and reliability of distribution systems. These management systems host a multitude of applications that can be used to sense, control, and operate distribution systems. Fault location, isolation, and service restoration (FLISR) is one of the ADMS applications that is critical to improving resilience during fault conditions. FLISR applications use smart, controllable devices that are installed in the distribution system for FLISR operation. These controllable devices include distributed energy resources (DER) and reclosers. Evaluating such ADMS applications before installation in the field can help de-risk the field implementation and avoid costly failures in the field. This paper presents a background on experimental setup that are typically used to evaluate ADMS applications. This is followed by briefly presenting the setup used to evaluate the FLISR application in an off-the-shelf ADMS tool. Finally, results from the evaluation experiments are presented.

94 GMLC - Grid Modernization Laboratory Consortium↗

V1G Frequency Regulation: Algorithm Development, Validation & Analysis at Scale

Researchers at Argonne National Laboratory developed and validated a high-fidelity digital twin of a smart charging (V1G) ecosystem to model the participation of up to 1,000 unique electric vehicles (EVs) in the PJM frequency regulation market. Utilizing a discrete-event framework, the simulation models complex interactions, from dynamic grid signals (updated every 2 seconds) to individual EV charging dynamics. The simulation incorporates multiple EV models created from real-world lab test data. Researchers tested multiple control algorithms to balance the dual objectives of maximizing aggregator’s revenue and driver charging needs. Results demonstrate that aggregated EVs function as a controllable, highly effective grid resource, achieving high PJM Performance Scores (80–90%). Additionally, an optimized, market-aware bidding strategy was identified as key to profitability. The platform was shown to provide drivers with an average charging discount of nearly 50%. The algorithm was further validated in the lab using production EVs and charging stations to compare simulation results with real-world performance.

Manne, Nithin↗

Distributed Intrusion Detection System using Semantic-based Rules for SCADA in Smart Grid

Cyber-physical system (CPS) security for the smart grid enables secure communication for the SCADA and wide-area measurement system data. Power utilities world-wide use various SCADA protocols, namely DNP3, Modbus, and IEC 61850, for the data exchanges across substation field devices, remote terminal units (RTUs), and control center applications. Adversaries may exploit compromised SCADA protocols for the reconnaissance, data exfiltration, vulnerability assessment, and injection of stealthy cyberattacks to affect power system operation. In this paper, we propose an efficient algorithm to generate robust rule sets. We integrate the rule sets into an intrusion detection system (IDS), which continuously monitors the DNP3 data traffic at a substation network and detects intrusions and anomalies in real-time. To enable CPS-aware wide-area situational awareness, we integrated the methodology into an open-source distributed-IDS (D-IDS) framework. The D-IDS facilitates central monitoring of the detected anomalies from the geographically distributed substations and to the control center. The proposed algorithm provides an optimal solution to detect network intrusions and abnormal behavior. Different types of IDS rules based on packet payload, packet flow, and time threshold are generated. Further, IDS testing and evaluation is performed with a set of rules in different sequences. The detection time is measured for different IDS rules, and the results are plotted. All the experiments are conducted at Power Cyber Lab, Iowa State University, for multiple power grid models. After successful testing and evaluation, knowledge and implementation are transferred to field deployment.

24 POWER TRANSMISSION AND DISTRIBUTION↗

TEAMER - Field Demonstration of MarineSitu’s Marine Energy Monitoring Tools - CRADA 664 (Abstract)

In order to effectively monitor for marine life around marine energy devices and thus minimize the risk of collision, multiple sensors working in coordination and augmented with around-the-clock automated monitoring algorithms need to be installed in challenging high-energy tidal and wave environments. Such systems are often too expensive for widespread adoption, or lack sufficient sensors or smarts to enable around-the-clock, real-time monitoring without human involvement. MarineSitu has been working to tackle this problem by developing a low-cost, combined sonar and stereo camera sensor array with connected real-time AI-based algorithms for automatically detecting marine life in these marine energy suitable environments. In this TEAMER project with Pacific Northwest National Lab (PNNL), MarineSitu will be testing this novel sensor system for the first time in the high-energy tidal channel environment at PNNL’s Marine and Coastal Research Lab. Throughout this deployment, MarineSitu will be monitoring their system and running analytics on the sensor’s data in real-time. Meanwhile, PNNL Data Scientists and Ocean Engineers, will be evaluating the system’s effectiveness and ease of use both as a tool for plug-and-play environmental monitoring and novel environmental monitoring research. In doing so, the team will improve MarineSitu’s system and software, produce insightful data products, and develop novel visualizations and AI algorithms for combining and analyzing the data produced by systems like MarineSitu’s.

16 TIDAL AND WAVE POWER↗

TEAMER – Field Demonstration of MarineSitu’s Marine Energy Monitoring (Abstract)

In order to effectively monitor for marine life around marine energy devices and thus minimize the risk of collision, multiple sensors working in coordination and augmented with around-the-clock automated monitoring algorithms need to be installed in challenging high-energy tidal and wave environments. Such systems are often too expensive for widespread adoption, or lack sufficient sensors or smarts to enable around-the-clock, real-time monitoring without human involvement. MarineSitu has been working to tackle this problem by developing a low-cost, combined sonar and stereo camera sensor array with connected real-time AI-based algorithms for automatically detecting marine life in these marine energy suitable environments. In this TEAMER project with Pacific Northwest National Lab (PNNL), MarineSitu will be testing this novel sensor system for the first time in the high-energy tidal channel environment at PNNL’s Marine and Coastal Research Lab. Throughout this deployment, MarineSitu will be monitoring their system and running analytics on the sensor’s data in real-time. Meanwhile, PNNL Data Scientists and Ocean Engineers, will be evaluating the system’s effectiveness and ease of use both as a tool for plug-and-play environmental monitoring and novel environmental monitoring research. In doing so, the team will improve MarineSitu’s system and software, produce insightful data products, and develop novel visualizations and AI algorithms for combining and analyzing the data produced by systems like MarineSitu’s.

16 TIDAL AND WAVE POWER↗

An 8-DOF dual-arm system for advanced teleoperation performance experiments

This paper describes the electro-mechanical and control features of an 8-DOF manipulator manufactured by AAI Corporation and installed at the Jet Propulsion Lab. (JPL) in a dual-arm setting. The 8-DOF arm incorporates a variety of features not found in other lab or industrial manipulators. Some of the unique features are: 8-DOF revolute configuration with no lateral offsets at joint axes; 1 to 5 payload to weight ratio with 20 kg (44 lb) payload at a 1.75 m (68.5 in.) reach; joint position measurement with dual relative encoders and potentiometer; infinite roll of joint 8 with electrical and fiber optic slip rings; internal fiber optic link of 'smart' end effectors; four-axis wrist; graphite epoxy links; high link and joint stiffness; use of an upgraded JPL Universal Motor Controller (UMC) capable of driving up to 16 joints. The 8-DOF arm is equipped with a 'smart' end effector which incorporates a 6-DOF forcemoment sensor at the end effector base and grasp force sensors at the base of the parallel jaws. The 8-DOF arm is interfaced to a 6 DOF force reflecting hand controller. The same system is duplicated for and installed at NASA-Langley.

Bejczy, Antal K.↗

Continuous Fiber Bath Treatments at Pilot Scale: A Novel Testbed System

The technical demands on high performance textiles continues to expand, and the research community has answered the call with innovative fiber bath treatments for enhanced properties and sizings for improved composites. However, little translation to greater scale has been demonstrated. To fill this gap, a novel, multifunctional system has been developed to explore polymer fiber treatment methods, the deployment of nanoadditive coatings and other sizings, and smart processing methods at the pilot scale. Continuous tows of fibers can be passed through a temperature-controlled, crossflow bath with an immersion residence time exceeding 2 hours. The modular system is resistant to corrosive solutions, includes additional inline stations for washing and drying after processing, is equipped with a bevy of sensors, pumps, and valves monitored and controlled by a LabView program, and can be fully contained in a standard lab fume hood. This new testbed system, when coupled with high fidelity materials characterization methods, will enable rapid evaluation of new fiber treatment methods at pilot-scale.

36 MATERIALS SCIENCE↗

Designing Remote Monitoring for Smart Manufacturing Facilities: Hazard Identification and Classification

This study investigates the process of hazard identification in complex manufacturing environments during the design phase, emphasizing the significance of the design process in developing designs that effectively mitigate hazards in contexts with numerous variables, such as a variety of machines, sensors, actuators, and agents. Through a mixed-methods approach, the objective of this work is to understand how the evolution of design outcomes across various stages might influence a designer’s ability to recognize both standard and novel hazards. To achieve this understanding, an experimental design task was conducted with six designers from a national lab specializing in manufacturing technologies. This approach combined qualitative and quantitative data analysis from a one-hour virtual session with participants. Findings suggest that the complexity of identifying hazards in a high-dimensional design space is challenging within a limited time frame and that the identification of hazards is significantly influenced by the stage of the design task and the initial design decisions, indicating the need for extended time and strategic initial planning in the design process to enhance hazard identification.

Ballestas, Caseysimone↗

Exploration Laboratory Analysis FY13

The Exploration Laboratory Analysis (ELA) project supports the Exploration Medical Capability (ExMC) risk, which is stated as the Risk of Inability to Adequately Treat an Ill or Injured Crew Member, and ExMC Gap 4.05: Lack of minimally invasive in-flight laboratory capabilities with limited consumables required for diagnosing identified Exploration Medical Conditions. To mitigate this risk, the availability of inflight laboratory analysis instrumentation has been identified as an essential capability in future exploration missions. Mission architecture poses constraints on equipment and procedures that will be available to treat evidence-based medical conditions according to the Space Medicine Exploration Medical Conditions List (SMEMCL), and to perform human research studies on the International Space Station (ISS) that are supported by the Human Health and Countermeasures (HHC) element. Since there are significant similarities in the research and medical operational requirements, ELA hardware development has emerged as a joint effort between ExMC and HHC. In 2012, four significant accomplishments were achieved towards the development of exploration laboratory analysis for medical diagnostics. These achievements included (i) the development of high priority analytes for research and medical operations, (ii) the development of Level 1 functional requirements and concept of operations documentation, (iii) the selection and head-to-head competition of in-flight laboratory analysis instrumentation, and (iv) the phase one completion of the Small Business Innovation Research (SBIR) projects under the topic Smart Phone Driven Blood-Based Diagnostics. To utilize resources efficiently, the associated documentation and advanced technologies were integrated into a single ELA plan that encompasses ExMC and HHC development efforts. The requirements and high priority analytes was used in the selection of the four in-flight laboratory analysis performers. Based upon the competition results, a down select process will be performed in the upcoming year. Looking ahead, this unified effort has positioned each element for an in-flight lab analysis demonstration of select diagnostics measurements in the 2015 timeframe.

Krihak, Michael↗