Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Slip transmission”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Dislocations in extruded Co-49.3 at. pct Al

Polycrystalline Co-49.3 at. pct Al, which had been extruded at 1505 K, was examined using transmission electron microscopy. Diffraction contrast analysis showed that b = 100 as well as b = 111 line dislocations contribute to elevated temperature deformation in CoAl. Therefore, it was concluded that sufficient slip systems exist in CoAl to allow for general plasticity in the absence of diffusional mechanisms. Line dislocations of the type b = 001 were observed on both 110 and 100 planes while b = 111 line dislocations were observed on 1 -1 0 planes.

Yaney, D. L.↗

Dislocation-density evolution and pileups in bicrystalline systems

Here, a dislocation-density crystalline plasticity (DCP) framework based on total and partial dislocation densities interactions was used to investigate the behavior of Cu/Pb bicrystals with a focus on GB effects. The modeling predictions were validated with bicrystal compression micropillar experiments. A key new aspect of the modeling approach is to account for partial dislocation-densities. A GB formulation that is directly linked to GB energies was used to monitor GB transmission and blockages, such that pileups can be monitored and predicted at the GB interfaces for misorientations. The predictions indicate that pileups can form due to fully and partially blocked slip-rates and perfect and partial dislocation-densities. As the nominal strain increases from five to fifteen percent, dislocation-densities and pileups significantly increase by almost an order of magnitude. The proposed validated approach provides a microstructural scale predictive framework that accounts for a myriad of defects related to the interactions of partial and perfect dislocation densities that interact at highly misoriented GBs; it is these interactions that are critical to the formation and evolution of dislocation-density pileups that can lead to physically limiting stress accumulations in bicrystals.

36 MATERIALS SCIENCE↗

Characterization of Cadmium-Zinc Telluride Crystals Grown by 'Contactless' PVT Using Synchrotron White Beam Topography

Crystals of Cd(1-x)Zn(x)Te grown by Physical Vapor Transport (PVT) using self-seeding 'contactless' techniques were characterized using synchrotron radiation (reflection, transmission, and Laue back-reflection X-ray topography). Crystals of low (x = 0.04) and high (up to x approx. = 0.4) ZnTe content were investigated. Twins and defects such as dislocations, precipitates, and slip bands were identified. Extensive inhomogeneous strains present in some samples were found to be generated by interaction (sticking) with the pedestal and by composition gradients in the crystals. Large (up to about 5 mm) oval strain fields were observed around some Te precipitates. Low angle grain boundaries were found only in higher ZnTe content (x greater than or equal to 0.2) samples.

Palosz, W.↗

On the Low Risk of SSR in Type III Wind Turbines Operating in Grid-Forming Control: Preprint

We have shown in a previous work that the risk of sub-synchronous resonance (SSR) between a wind power plant with Type III wind turbines and series-compensated transmission lines is low when the wind turbines in the plant are operated in grid-forming mode, instead of the standard grid-following mode. The fundamental mechanism behind the improved damping characteristics is explained in this paper by modeling the positive and negative sequence impedances of Type III wind turbines for GFM operation mode. It is discovered that the GFM control naturally acts against the negative resistance of Type III wind turbines that results from an interaction between the proportional gain of the rotor-side converter current controller and negative slip. The developed sequence impedance models and improved damping behavior are verified using PSCAD simulations of a 2.5-MW Type III GFM wind turbine. The modeling predictions are also supported by experimentally measuring the sequence impedance response of a 2.5-MW Type III wind turbine during operation in GFL and GFM modes.

grid-following turbine↗

The effect of hydrogen on the deformation behavior of a single crystal nickel-base superalloy

The effect of hydrogen on the tensile deformation behavior of PWA 1480 is presented. Tensile tests were interrupted at different plastic strain levels to observe the development of the dislocation structure. Transmission electron microscopy (TEM) foils were cut perpendicular to the tensile axis to allow the deformation of both phases to be simultaneously observed as well as parallel to zone axes (III) to show the superdislocations on their slip planes. Similar to other nickel-base superalloys, hydrogen was detrimental to the room temperature tensile properties of PWA 1480. There was little effect on strength, however the material was severely embrittled. Even without hydrogen, the elongation-to-failure was only approximately 3 percent. The tensile fracture surface was made up primarily of ductile voids with regions of cleavage fracture. These cleavage facets are the eutectic (gamma') in the microstructure. It was shown by quantitative fractography that hydrogen embrittles the eutectic (gamma') and causes the crack path to seek out and fracture through the eutectic (gamma'). There was two to three times the amount of cleavage on the fracture surface of the hydrogen-charged samples than on the surface of the uncharged samples. The effect of hydrogen can also be seen in the dislocation structure. There is a marked tendency for dislocation trapping in the gamma matrix with and without hydrogen at all plastic strain levels. Without hydrogen there is a high dislocation density in the gamma matrix leading to strain exhaustion in this region and failure through the matrix. The dislocation structure at failure with hydrogen is slightly different. The TEM foils cut parallel to zone axes (III) showed dislocations wrapping around gamma precipitates. Zone axes (001) foils show that there is a lower dislocation density in the gamma matrix which can be linked to the effects of hydrogen on the fracture behavior. The primary activity in the gamma precipitates is in the form of superlattice intrinsic stacking faults (SISFs). These faults have also been reported in other ordered alloys and superalloys.

Walston, W. S.↗

An in situ ambient and cryogenic transmission electron microscopy study of the effects of temperature on dislocation behavior in CrCoNi-based high-entropy alloys with low stacking-fault energy

Temperature is known to affect deformation mechanisms in metallic alloys. As temperature decreases, the stacking-fault energy in many face-centered cubic (fcc) alloys decreases, resulting in a change of deformation mode from dislocation slip to deformation twinning. Such an impact of temperature can be more complex in compositionally heterogeneous microstructures that exhibit, for example, local concentration fluctuation such as that in multi-principal element alloys. In this work, we compare the dislocation behavior and mechanical properties of a fcc Cr 20 Mn 10 Fe 30 Co 30 Ni 10 high-entropy alloy at ambient and liquid-nitrogen temperatures. We find that a network of stacking faults is formed by uniformly extended dislocations at ambient temperatures with low stacking-fault energy, whereas at lower temperatures, uneven dissociation of dislocations becomes significant, which results in severe dislocation pile-ups together with their pronounced entanglement. Our findings indicate that as the stacking-fault energy decreases with decreasing temperature, the heterogeneity of the distribution of elements becomes more dominant in tuning the local variation of lattice resistance. As a result, the change in dislocation behavior at low temperatures strongly affects microstructural evolution and consequently leads to significantly more pronounced work hardening.

36 MATERIALS SCIENCE↗

Numerical experiments with flows of elongated granules

Theory and numerical results are given for a program simulating two dimensional granular flow (1) between two infinite, counter-moving, parallel, roughened walls, and (2) for an infinitely wide slider. Each granule is simulated by a central repulsive force field ratcheted with force restitution factor to introduce dissipation. Transmission of angular momentum between particles occurs via Coulomb friction. The effect of granular hardness is explored. Gaps from 7 to 28 particle diameters are investigated, with solid fractions ranging from 0.2 to 0.9. Among features observed are: slip flow at boundaries, coagulation at high densities, and gross fluctuation in surface stress. A videotape has been prepared to demonstrate the foregoing effects.

Elrod, Harold G.↗

Flat H Redundant Frangible Joint Development

Orion and Commercial Crew Program (CCP) Partners have chosen to use frangible joints for certain separation events. The joints currently available are zero failure tolerant and will be used in mission safety applications. The goal is to further develop a NASA designed redundant frangible joint that will lower flight risk and increase reliability. FY16 testing revealed a successful design in subscale straight test specimens that gained efficiency and supports Orion load requirements. Approach / Innovation A design constraint is that the redundant joint must fit within the current Orion architecture, without the need for additional vehicle modification. This limitation required a design that changed the orientation of the expanding tube assemblies (XTAs), by rotating them 90deg from the standard joint configuration. The change is not trivial and affects the fracture mechanism and structural load paths. To address these changes, the design incorporates cantilevered arms on the break plate. The shock transmission and expansion of the XTA applies force to these arms and creates a prying motion to push the plate walls outward to the point of structural failure at the notched section. The 2014 test design revealed that parts could slip during functioning wasting valuable energy needed to separate the structure with only a single XTA functioning. Dual XTA functioning fully separated the assembly showing a discrepancy can be backed up with redundancy. Work on other fully redundant systems outside NASA is limited to a few patents that have not been subjected to functionality testing Design changes to prevent unwanted slippage (with ICA funding in 2015) showed success with a single XTA. The main goal for FY 2016 was to send the new Flat H RFJ to WSTF where single XTA test failures occurred back in 2014. The plan was to gain efficiency in this design by separating the Flat H RFJ with thicker ligaments with dimensions baselined in 2014. Other modifications included geometry changes to better disperse loads paths and to minimize air gaps. The design additionally added more structural strength to enhance the structural limits in static loads testing. The design also implemented a smoother load line through the assembly. Results / Knowledge Gained The new Flat H RFJ successfully fractured at WSTF with thicker ligaments and lower cord size. Where failure to separate occurred earlier, there is now excessive energy available for structural separation. The new challenge to provide some structural support to prevent secondary fracturing of the break plate remains to be completed. This future work is being funded by the JSC Engineering Directorate in 2017 to elevate the TRL on curved Flat H RFJs that configure with the Orion Service Panel Separation. Additional funding from JSC Engineering will provide new design testing to avoid secondary fracturing.

Brown, Chris↗

Effect of mean-velocity profile shapes on sound transmission through two-dimensional ducts

Acoustic propagation through a lined two-dimensional duct is examined in order to assess the influence of the shape of the mean-velocity profile on the attenuation rate. Five mean-velocity profiles are considered: linear, parabolic, Pohlhausen, 1/7th power law with a linear sub-layer, and linear with slip at the wall. It is shown that when the attenuation rate is tabulated as a function of the boundary-layer thickness, as is usually done, substantially different results are obtained from the several mean profiles. However, when the displacement thickness is used, a considerable collapse is achieved in the attenuation curves that are obtained from the various profiles. For downstream propagation, all profiles produce essentially the same results over a reasonable range of boundary-layer thickness. However, for many cases of upstream propagation, the results from the 'turbulent' boundary-layer profiles differ significantly from the results of the other profiles even when compared on the basis of displacement thickness.

Hayfeh, A. H.↗

Mechanical properties and deformation mechanisms of single crystal Mg micropillars subjected to high-strain-rate C-axis compression

Here, the mechanical properties and deformation mechanisms of single crystal magnesium under c-axis quasi-static and high-strain rate compressions are investigated through in situ scanning electron microscope (SEM) experiments and post-mortem transmission electron microscope (TEM) characterization. The findings revealed that ductility and high rates of hardening are preserved for pillars as large as 15 μm. Furthermore, rate effects result in a mild increase in flow stress with plastic deformations controlled primarily by the slip of type dislocations. Importantly and in contrast to other literature reports, plastic deformation occurs in the absence of twining. As the strain increases and plastic deformation exceeds about 4%, crystal rotation activates basal slip, <$\mathrm{a}$> type dislocations, resulting in a more rate independent flow stress. TEM observation on micropillars compressed at a strain rate of 250/s, revealed the activation of {${11}$$\bar{2}$$\bar{2}$} < $\bar{1}$$\bar{1}23$ > slip systems and high mobility of screw dislocations as major contributors to plastic strains in excess of 10% without fracture. These findings are relevant to the design of lightweight materials used in transportation systems, e.g., selection of material grain size. Moreover, the experimental data here reported provides the materials science community with a unique opportunity to validate discrete dislocation dynamics (DDD) formulations employed in multiscale design of materials.

36 MATERIALS SCIENCE↗

Solute effects upon dislocation motion and recovery in Mg alloys (Final Report)

The objective the research was to develop a firmer understanding of the interactions between substitutional solute atoms and dislocations within Mg alloys. These interactions govern the absolute and relative mobilities of various types of dislocations in Mg (e.g., basal < a>, non-basal < a>, and pyramidal < c+a>). Furthermore, they have an impact on dislocation recovery processes (e.g., cross-glide, climb, rearrangement, and annihilation). Ultimately, solute-dislocation interactions strongly impact a) strain hardening, b) strain rate sensitivity, c) plastic anisotropy of textured polycrystals, d) texture evolution, e) dislocation substructures evolution, and even f) recrystallization behavior. It is broadly known that Mg alloys exhibit poor low temperature formability. Since formability is largely governed by properties (a) – (c) in this list, it is critical to develop a better understanding of solute-dislocation interactions, if one hopes to improve the situation. While the theory of static solute strengthening is well developed, especially for alloys with face centered cubic (FCC) crystal structures, there are outstanding questions related to applications to hexagonal close packed (HCP) crystal structures and dynamic strain aging (DSA) in materials of various structures. DSA has far-reaching implications for metal formability and, in the case of Mg alloys, appears to correlate with the so-called rare-earth (RE) texture which has been shown to benefit formability. The Portevin-Le Chatelier (PLC) effect, and associated negative strain rate sensitivity, occur at higher temperatures (>100℃) in Mg alloys as compared with similar Al alloys, even though they have similar melting points and solute diffusivities. Our preliminary research has shown that modern, physics-based models of DSA can be tuned to describe the behavior of Mg alloys if a rather higher activation enthalpy is assumed for cross-core diffusivity. While this partially explains the delay in DSA to higher temperatures, it is also hypothesized that this delay is due in part to the intrinsically more thermally activated (rate sensitive) nature of non-basal < a> dislocation motion which is required for macroscopic flow of Mg alloys, whereas octahedral slip in many FCC metals like aluminum is essentially athermal at room temperature. It was originally proposed to employ a combination of in-situ diffraction-based experimental characterization to validate existing theory. It was envisioned to perform in-situ transmission electron microscopy (TEM) to assess individual dislocation behavior and in-situ high-energy X-ray diffraction (HEXRD) techniques which were showing great promise for elucidating collective dislocation behavior, 2 including recovery, especially if the contributions to various forms of diffraction peak broadening (𝜂𝜂,𝜔𝜔,and 2𝜃𝜃) can be effectively integrated. Finally, it was envisioned to perform discrete dislocation dynamics (DDD) modeling approaches to aide in the interpretation of both TEM and HEXRD experiments. In the end, mechanical tests were performed on more complex Mg alloys which exhibited evidence of dynamic strain aging, and this led to the establishment of another project. Mechanical test data obtained at McMaster University served as the basis of an assessment of the applicability of Bazinski’s “stress equivalence” theory of solute strengthening to polycrystalline alloys of Mg. Although we did not succeed in applying the approach to Mg alloys, we did develop expertise with the HEXRD approach using a BCC, β-Ti alloy and demonstrated numerous new capabilities that may be applied to any polycrystalline material in collaboration with researchers at CHESS and around the world: (1) assessment of details of the elastoplastic transition (yielding) using a combination of HEXRD and full-field polycrystal plasticity modeling, (2) the first-ever experimental observation of strong stress rotation within the individual grains of a polycrystalline material, and (3) a comprehensive analysis of the grain-level dislocation density evolution based upon diffraction peak broadening along 𝜂𝜂,𝜔𝜔,and 2𝜃𝜃 directions. This final aspect allowed us to confirm that dislocations were gliding on multiple plane types and not restricted to {110} type planes, and it also provided clues as to why some grains were unloading during straining, with surprising implications for our understanding of the effects of geometrically necessary dislocations (GNDs). Finally, graduate student, Mohammed Shabana, developed a MATLAB code which confirmed the conclusions of Prof. Catalin Picu (Rensallear Polytechnic Institute, RPI) regarding the effect of solute-trapped, forest dislocations on the breaking stress of Lomer lock junctions in FCC metal alloys. He applied the same anisotropic line-tension model to a variety of dislocation junction configurations and found an inconsistency in the widely cited results of Dupuy and Fivel regarding the Hirth Lock, and he outlined an approach to extend these finding to HCP Mg alloys that we are still pursuing with discretionary fundings at UVA.

36 MATERIALS SCIENCE↗

Dynamic fracture processes in hydrogen embrittled iron

Mechanistic understanding of hydrogen embrittlement is critical to the transport and storage of hydrogen as a sustainable fuel. Experimental observation of dynamic fracture processes in hydrogen environments has been challenging. Here, in-situ transmission X-ray microscopy is used to image polycrystalline iron foils that are concurrently strained and electrochemically charged with hydrogen. Using this technique, voids and microcracks down to ∼30 nm in size are identified at or near the crack tip and tracked as strain is increased. We observe both hydrogen-induced transgranular failure and hydrogen-induced intergranular failure with distinct fracture processes. We find that transgranular fracture occurs through the formation of sharp branched structures at the main crack tip that are reminiscent of slip band formation. This is followed by void growth and coalescence, and interaction with secondary cracks that lead to propagation of the main crack. Intergranular fracture is found to occur through void coalescence along grain boundaries, along with significant secondary cracking near the crack tip. The crack growth rate is greater for void-mediated intergranular failure than for slip-mediated transgranular failure. Additionally, the removal of hydrogen results in recovered ductility for a crack initially propagated under hydrogen charging.

36 MATERIALS SCIENCE↗

Damage Detection and Electrical Performance Impact of Flat-Flexible Circuits

Flat-flexible circuits or ‘flex circuits’ have varied applications in electronics and in explosive detonation systems. They pose advantages over conventional coaxial cables in their ability to fit into small mechanical envelopes and routings. A typical flex circuit is composed of a laminated assembly of multiple layers of conductor and dielectric materials. Copper, because of its high electrical conductivity, is one of the primary materials used in flex circuit conductors. The conductor must maintain structural integrity and electrical continuity when the flexible circuit is bent during processing or to fit an application envelope. Under some strain conditions a cable may have degraded electrical performance even though visible damage may not be evident. Dislocation density can increase by mechanisms such as dislocation forest hardening, where gliding dislocations in primary slip planes get pinned at obstacles and form Frank-Read sources. Dislocation density increases within the conductor layers may impact electrical resistivity but would not necessarily result in visible mechanical failure. In some detonation applications, such as for building implosion for demolition, the time for signal transmission and voltage used for firing detonators can be critical. If the resistance in a single flex cable within a building demolition array is too high, the resultant demolition shape may be asymmetric, leading to unplanned damage to nearby structures and potential hazards to public safety. This study will apply non-destructive evaluation techniques to evaluate the detectability of damage accumulation in flat, flexible copper-conductor cables and discuss potential implications to their practical use.

42 ENGINEERING↗

On the Low Risk of SSR in Type III Wind Turbines Operating with Grid-Forming Control

We have shown in previous work that the risk of subsynchronous resonance between wind power plants with Type III wind turbines and series-compensated transmission lines is low when the wind turbines are operated in grid-forming (GFM) mode instead of the standard grid-following mode. This paper explains the fundamental mechanism behind the improved damping characteristics by modeling the positive- and negative-sequence impedances of Type III wind turbines in GFM control mode. Here it is discovered that the GFM control naturally acts against the negative resistance behavior of Type III wind turbines at subsynchronous frequencies that results from an interaction between the rotor-side converter current controller and negative slip. The developed impedance models in the sequence domain and the improved damping behavior are verified using PSCAD simulations of a 2.5-MW Type III GFM wind turbine. The modeling predictions are also supported by experimentally measuring the impedance response of a 2.5-MW Type III wind turbine in GFM mode.

17 WIND ENERGY↗

Design study of steel V-Belt CVT for electric vehicles

A continuously variable transmission (CVT) design layout was completed. The intended application was for coupling the flywheel to the driveline of a flywheel battery hybrid electric vehicle. The requirements were that the CVT accommodate flywheel speeds from 14,000 to 28,000 rpm and driveline speeds of 850 to 5000 rpm without slipping. Below 850 rpm a slipping clutch was used between the CVT and the driveline. The CVT was required to accommodate 330 ft-lb maximum torque and 100 hp maximum transient. The weighted average power was 22 hp, the maximum allowable full range shift time was 2 seconds and the required lift was 2600 hours. The resulting design utilized two steel V-belts in series to accommodate the required wide speed ratio. The size of the CVT, including the slipping clutch, was 20.6 inches long, 9.8 inches high and 13.8 inches wide. The estimated weight was 155 lb. An overall potential efficiency of 95 percent was projected for the average power condition.

Swain, J. C.↗

Fatigue damage accumulation in nickel prior to crack initiation

The accumulation of lattice defects during fatigue cycling of nickel was investigated by electrical resistivity measurements, positron annihilation lifetime spectroscopy and transmission electron microscopy. Dislocations and vacancy clusters were found to be the main defect types. During cycling of axial and flexural samples at constant load amplitude, the dislocations form a saturated structure early in the fatigue life. This saturated structure consists of a cellular dislocation matrix, in which persistent slip bands (PSBs) begin to operate after the saturation has been established. Vacancies and vacancy clusters are formed during fatigue as a consequence of repetitive dislocation glide in the PSB structure. When PSBs operate, the matrix is assumed to be dormant, allowing vacancies to accumulate preferentially in the PSBs. The increase in vacancy concentration then accounts for the monotonic accumulation of fatigue damage, which points to the importance of vacancy accumulation as a precursor to crack nucleation.

Grobstein, T. L.↗

On the Low Risk of Subsynchronous Resonance (SSR) in Type III Wind Turbines Operating in Grid-Forming Control

We have shown in a previous work that the risk of sub-synchronous resonance (SSR) between a wind power plant with Type III wind turbines and series-compensated transmission lines is low when the wind turbines in the plant are operated in grid-forming mode, instead of the standard grid-following mode. The fundamental mechanism behind the improved damping characteristics is explained in this paper by modeling the positive and negative sequence impedances of Type III wind turbines for GFM operation mode. It is discovered that the GFM control naturally acts against the negative resistance of Type III wind turbines that results from an interaction between the proportional gain of the rotor-side converter current controller and negative slip. The developed sequence impedance models and improved damping behavior are verified using PSCAD simulations of a 2.5-MW Type III GFM wind turbine. The modeling predictions are also supported by experimentally measuring the sequence impedance response of a 2.5-MW Type III wind turbine during operation in GFL and GFM modes.

grid-following turbine↗