Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Single-photon detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Novel Photon-Counting Detectors for Free-Space Communication

We present performance data for novel photon-counting detectors for free space optical communication. NASA GSFC is testing the performance of two types of novel photon-counting detectors 1) a 2x8 mercury cadmium telluride (HgCdTe) avalanche array made by DRS Inc., and a 2) a commercial 2880-element silicon avalanche photodiode (APD) array. We present and compare dark count, photon-detection efficiency, wavelength response and communication performance data for these detectors. We successfully measured real-time communication performance using both the 2 detected-photon threshold and AND-gate coincidence methods. Use of these methods allows mitigation of dark count, after-pulsing and background noise effects. The HgCdTe APD array routinely demonstrated photon detection efficiencies of greater than 50% across 5 arrays, with one array reaching a maximum PDE of 70%. We performed high-resolution pixel-surface spot scans and measured the junction diameters of its diodes. We found that decreasing the junction diameter from 31 micrometers to 25 micrometers doubled the e- APD gain from 470 for an array produced in the year 2010 to a gain of 1100 on an array delivered to NASA GSFC recently. The mean single-photon SNR was over 12 and the excess noise factors measurements were 1.2-1.3. The commercial silicon APD array exhibited a fast output with rise times of 300 ps and pulse widths of 600 ps. On-chip individually filtered signals from the entire array were multiplexed onto a single fast output.

Photons↗

Hemispherical Field-of-View Above-Water Surface Imager for Submarines

A document discusses solutions to the problem of submarines having to rise above water to detect airplanes in the general vicinity. Two solutions are provided, in which a sensor is located just under the water surface, and at a few to tens of meter depth under the water surface. The first option is a Fish Eye Lens (FEL) digital-camera combination, situated just under the water surface that will have near-full- hemisphere (360 azimuth and 90 elevation) field of view for detecting objects on the water surface. This sensor can provide a three-dimensional picture of the airspace both in the marine and in the land environment. The FEL is coupled to a camera and can continuously look at the entire sky above it. The camera can have an Active Pixel Sensor (APS) focal plane array that allows logic circuitry to be built directly in the sensor. The logic circuitry allows data processing to occur on the sensor head without the need for any other external electronics. In the second option, a single-photon sensitive (photon counting) detector-array is used at depth, without the need for any optics in front of it, since at this location, optical signals are scattered and arrive at a wide (tens of degrees) range of angles. Beam scattering through clouds and seawater effectively negates optical imaging at depths below a few meters under cloudy or turbulent conditions. Under those conditions, maximum collection efficiency can be achieved by using a non-imaging photon-counting detector behind narrowband filters. In either case, signals from these sensors may be fused and correlated or decorrelated with other sensor data to get an accurate picture of the object(s) above the submarine. These devices can complement traditional submarine periscopes that have a limited field of view in the elevation direction. Also, these techniques circumvent the need for exposing the entire submarine or its periscopes to the outside environment.

Hemmati, Hamid↗

Three Photon Excited Image Scanning Microscopy for in-Depth Super-Resolution Studies of Biological Samples

Multiphoton laser scanning microscopy is a powerful tool for deep imaging of thick biological samples. Image scanning microscopy (ISM) has demonstrated significant improvements in the signal-to-noise ratio in confocal laser scanning microscopy, while at the same time improving upon the effectively attainable resolution. Two-photon excitation (2PE), combined with ISM, has been shown to allow for deep tissue imaging with enhanced resolution compared to 2PE microscopy. Three-photon excitation (3PE) has enabled record imaging depth and contrast for multiphoton imaging, due to the superior suppression of out-of-focus signal generation. In this paper, we demonstrate super-resolution 3PE ISM. This is achieved using a single-photon avalanche detector array, and 1040-nm pulses for 3PE of blue fluorescence. This method enables subdiffraction limited resolution imaging of biological samples stained with blue fluorescent markers, such as mouse myocardial and spinal cord tissues stained with 4 ′ , 6 -diamidino-2-phenylindole. Deconvolution improves the resolving power further and allows for imaging with better than λ / 8 resolution with respect to the 3PE wavelength λ . With the ISM pixel reassignment procedure, we demonstrate a resolution enhancement of ∼ 1.6 laterally, compared to the resolution attained using a photomultiplier tube in a non-descanned detection arrangement, and a factor of ∼ 1.8 enhancement in axial resolution. The experimentally measured three-dimensional point spread function volume is shrunk ∼ 4.4 -fold, which is close to the theoretically expected enhancement. Published by the American Physical Society 2024

47 OTHER INSTRUMENTATION↗

NASA Tech Briefs, November 2011

The topics include: 1) Flight Test Results from the Rake Airflow Gage Experiment on the F-15B; 2) Telemetry and Science Data Software System; 3) CropEx Web-Based Agricultural Monitoring and Decision Support; 4) High-Performance Data Analysis Tools for Sun-Earth Connection Missions; 5) Experiment in Onboard Synthetic Aperture Radar Data Processing; 6) Microfabrication of a High-Throughput Nanochannel Delivery/Filtration System; 7) Improved Design and Fabrication of Hydrated-Salt Pills; 8) Monolithic Flexure Pre-Stressed Ultrasonic Horns; 9) Cryogenic Quenching Process for Electronic Part Screening; 10) Broadband Via-Less Microwave Crossover Using Microstrip-CPW Transitions; 11) Wheel-Based Ice Sensors for Road Vehicles; 12) G-DYN Multibody Dynamics Engine; 13) Multibody Simulation Software Testbed for Small-Body Exploration and Sampling; 14) Propulsive Reaction Control System Model; 15) Licklider Transmission Protocol Implementation; 16) Core Recursive Hierarchical Image Segmentation; 17) Two-Stage Centrifugal Fan; 18) Combined Structural and Trajectory Control of Variable-Geometry Planetary Entry Systems; 19) Pressure Regulator With Internal Ejector Circulation Pump, Flow and Pressure Measurement Porting, and Fuel Cell System Integration Options; 20) Temperature-Sensitive Coating Sensor Based on Hematite; 21) Standardization of a Volumetric Displacement Measurement for Two-Body Abrasion Scratch Test Data Analysis; 22) Detection of Carbon Monoxide Using Polymer-Carbon Composite Films; 23) Substituted Quaternary Ammonium Salts Improve Low-Temperature Performance of Double-Layer Capacitors; 24) Sustainably Sourced, Thermally Resistant, Radiation Hard Biopolymer; 25) Integrated Lens Antennas for Multi-Pixel Receivers; 26) 180-GHz Interferometric Imager; 27) Maturation of Structural Health Management Systems for Solid Rocket Motors; 28) Validating Phasing and Geometry of Large Focal Plane Arrays; 29) Transverse Pupil Shifts for Adaptive Optics Non-Common Path Calibration; 30) Qualification of Fiber Optic Cables for Martian Extreme Temperature Environments; 31) Solid-State Spectral Light Source System; 32) Multiple-Event, Single-Photon Counting Imaging Sensor; 33) Surface Modeling to Support Small-Body Spacecraft Exploration and Proximity Operations; and 34) Achieving Exact and Constant Turnaround Ratio in a DDS-Based Coherent Transponder.

Source record↗

Effect of color coding and subtraction on the accuracy of contrast echocardiography

BACKGROUND: Contrast echocardiography may be used to assess myocardial perfusion. However, gray scale assessment of myocardial contrast echocardiography (MCE) is difficult because of variations in regional backscatter intensity, difficulties in distinguishing varying shades of gray, and artifacts or attenuation. We sought to determine whether the assessment of rest myocardial perfusion by MCE could be improved with subtraction and color coding. METHODS AND RESULTS: MCE was performed in 31 patients with previous myocardial infarction with a 2nd generation agent (NC100100, Nycomed AS), using harmonic triggered or continuous imaging and gain settings were kept constant throughout the study. Digitized images were post processed by subtraction of baseline from contrast data and colorized to reflect the intensity of myocardial contrast. Gray scale MCE alone, MCE images combined with baseline and subtracted colorized images were scored independently using a 16 segment model. The presence and severity of myocardial contrast abnormalities were compared with perfusion defined by rest MIBI-SPECT. Segments that were not visualized by continuous (17%) or triggered imaging (14%) after color processing were excluded from further analysis. The specificity of gray scale MCE alone (56%) or MCE combined with baseline 2D (47%) was significantly enhanced by subtraction and color coding (76%, p<0.001) of triggered images. The accuracy of the gray scale approaches (respectively 52% and 47%) was increased to 70% (p<0.001). Similarly, for continuous images, the specificity of gray scale MCE with and without baseline comparison was 23% and 42% respectively, compared with 60% after post processing (p<0.001). The accuracy of colorized images (59%) was also significantly greater than gray scale MCE (43% and 29%, p<0.001). The sensitivity of MCE for both acquisitions was not altered by subtraction. CONCLUSION: Post-processing with subtraction and color coding significantly improves the accuracy and specificity of MCE for detection of perfusion defects.

Multicenter Study↗

Generation of a fluorescent short-lifetime oxygen nanosensor by coupling of an exciplex forming dye pair

Typical oxygen-sensitive dyes have lifetimes in the μs-ms regime for sensitive oxygen detection based on molecular quenching. Due to the long triplet-state lifetimes and poor quenching efficiency of these probes, it has been difficult to develop short lifetime probes. We have developed oxygen sensors using a short-lifetime dye (∼30–60 ns) that forms an anthracene-aniline exciplex, which is quenched by molecular oxygen through an excited-state charge transfer mechanism. To achieve measurements in aqueous systems, we have tethered the dyes together via a C3 alkyl linker to facilitate greater exciplex formation at low dye concentration (20 μg mL −1 ) and encapsulated the resulting compound into polymeric nanoparticles to form an aqueous-dispersible short-lifetime oxygen nanosensor. The sensors emit at 420 nm (unfolded dye) and 500 nm (exciplex), and the ratiometric Stern-Volmer Constant is 1.52 ± 0.02 L mol −1 , showing good sensitivity from 0 % to 40 % dissolved oxygen without the tradeoff of a long lifetime needed for direct molecular quenching. In this paper, we characterize this sensor for both lifetime-based measurements using time-correlated single-photon counting and ratiometric intensity-based measurements using the unfolded dye emission as an internal reference peak.

Biological and medical sciences↗

NASA Tech Briefs, May 2010

Topics covered include: Instrument for Analysis of Greenland's Glacier Mills Cryogenic Moisture Apparatus; A Transportable Gravity Gradiometer Based on Atom Interferometry; Three Methods of Detection of Hydrazines; Crossed, Small-Deflection Energy Analyzer for Wind/Temperature Spectrometer; Wavefront Correction for Large, Flexible Antenna Reflector; Novel Micro Strip-to-Waveguide Feed Employing a Double-Y Junction; Thin-Film Ferro Electric-Coupled Microstripline Phase Shifters With Reduced Device Hysteresis; Two-Stage, 90-GHz, Low-Noise Amplifier; A 311-GHz Fundamental Oscillator Using InP HBT Technology; FPGA Coprocessor Design for an Onboard Multi-Angle Spectro-Polarimetric Imager; Serrating Nozzle Surfaces for Complete Transfer of Droplets; Turbomolecular Pumps for Holding Gases in Open Containers; Triaxial Swirl Injector Element for Liquid-Fueled Engines; Integrated Budget Office Toolbox; PLOT3D Export Tool for Tecplot; Math Description Engine Software Development Kit; Astronaut Office Scheduling System Software; ISS Solar Array Management; Probabilistic Structural Analysis Program; SPOT Program; Integrated Hybrid System Architecture for Risk Analysis; System for Packaging Planetary Samples for Return to Earth; Offset Compound Gear Drive; Low-Dead-Volume Inlet for Vacuum Chamber; Simple Check Valves for Microfluidic Devices; A Capillary-Based Static Phase Separator for Highly Variable Wetting Conditions; Gimballing Spacecraft Thruster; Finned Carbon-Carbon Heat Pipe with Potassium Working Fluid; Lightweight Heat Pipes Made from Magnesium; Ceramic Rail-Race Ball Bearings; Improved OTEC System for a Submarine Robot; Reflector Surface Error Compensation in Dual-Reflector Antennas; Enriched Storable Oxidizers for Rocket Engines; Planar Submillimeter-Wave Mixer Technology with Integrated Antenna; Widely Tunable Mode-Hop-Free External-Cavity Quantum Cascade Laser; Non-Geiger-Mode Single-Photon Avalanche Detector with Low Excess Noise; Using Whispering-Gallery-Mode Resonators for Refractometry; RF Device for Acquiring Images of the Human Body; Reactive Collision Avoidance Algorithm; Fast Solution in Sparse LDA for Binary Classification; Modeling Common-Sense Decisions in Artificial Intelligence; Graph-Based Path-Planning for Titan Balloons; Nanolaminate Membranes as Cylindrical Telescope Reflectors; Air-Sea Spray Airborne Radar Profiler Characterizes Energy Fluxes in Hurricanes; Large Telescope Segmented Primary Mirror Alignment; and Simplified Night Sky Display System.

Source record↗

Enhancing spectroscopy and microscopy with emerging methods in photon correlation and quantum illumination

Quantum optics has led to important advancements in our ability to prepare and detect correlations between individual photons. Its principles are increasingly translated into nanoscale characterization tools, furthering methods in spectroscopy, microscopy and metrology. Here, in this Review, we discuss the rapid progress in this field driven by advanced technologies of single-photon detectors and quantum-light sources, including time-resolved single-photon counting cameras, superconducting nanowire single-photon detectors and entangled photon sources of increasing brightness. We emphasize emerging applications in super-resolution microscopy, measurements below classical noise limits and photon-number-resolved spectroscopy—a powerful paradigm for the characterization of nanoscale electronic materials. We conclude by discussing key technological challenges and future opportunities in materials science and bionanophotonics alike.

Tsao, Chieh [University of California, Berkeley, C↗

Enhancing the Cherenkov over scintillation ratio using dichroic filters in BGO and TlCl for TOF-PET

Abstract The Cherenkov emission in inorganic crystal scintillators has been shown to dramatically improve time resolution for time-of-flight positron emission tomography (TOF-PET) for in slow scintillators with a high refractive index such as bismuth germanium oxide (BGO). This is due to the faster nature of the Cherenkov emission (tens of picoseconds) with respect to scintillation (nanosecond). However, the presence of slower scintillation light and the inability of existing detectors to distinguish between Cherenkov and scintillation make it difficult for BGO to achieve a good CTR for all the detected coincidence events. In this paper, we exploit the difference between the Cherenkov and scintillation emission spectra and use dichroic filters to enhance the Cherenkov over scintillation ratio. Dichroic filters transmit or reflect photons based on their wavelength, with a photon attenuation lower than 10%. We investigate several shortpass and longpass dichroic filters in a single-photon configuration with BGO and find the optimal filter that maximizes the Cherenkov over scintillation ratio. We demonstrate that we can enhance the ratio of Cherenkov to scintillation photons by a factor of 2.17 ± 0.38 by employing a shortpass dichroic filter with a cut-off wavelength of 450 nm for BGO, and by a factor of 2.87 ± 0.40 using a longpass dichroic filter with a cut-on wavelength of 550 nm for iodine/beryllium-doped thallium chloride.

Science & Technology - Other Topics↗

Highly excited electron cyclotron for QCD axion and dark-photon detection

We propose using highly excited cyclotron states of a trapped electron to detect meV axion and dark-photon dark matter, marking a significant improvement over our previous proposal and demonstration [One-electron quantum cyclotron as a milli-ev dark-photon detector, .]. When the axion mass matches the cyclotron frequency ω c , the cyclotron state is resonantly excited, with a transition probability proportional to its initial quantum number, n c . The sensitivity is enhanced by taking n c ∼ 10 6 ( 0.1 meV ω c ) 2 . By optimizing key experimental parameters, we minimize the required averaging time for cyclotron detection to t ave ∼ 10 − 6 s, permitting detection of such a highly excited state before its decay. An open–end-cap trap design enables the external photon signal to be directed into the trap, rendering our background-free detector compatible with large focusing cavities, such as the BREAD proposal, while capitalizing on their strong magnetic fields. Furthermore, the axion conversion rate can be coherently enhanced by incorporating layers of dielectrics with alternating refractive indices within the cavity. Collectively, these optimizations enable us to probe the QCD axion parameter space from 0.1 to 2.3 meV (25–560 GHz), covering a substantial portion of the predicted postinflationary QCD axion mass range. This sensitivity corresponds to probing the kinetic mixing parameter of the dark photon down to ε ≈ 2 × 10 − 16 . Published by the American Physical Society 2025

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Millimeter-Wave Superconducting Qubit

Manipulating the electromagnetic spectrum at the single-photon level is fundamental for quantum experiments. In the visible and infrared ranges, this can be accomplished with atomic quantum emitters, and with superconducting qubits such control is extended to the microwave range (below 10 GHz). Meanwhile, the region between these two energy ranges presents an unexplored opportunity for innovation. We bridge this gap by scaling up a superconducting qubit to the millimeter-wave range (near 100 GHz). Working in this energy range greatly reduces sensitivity to thermal noise compared to microwave devices, enabling operation at significantly higher temperatures, up to 1 K. This has many advantages by removing the dependence on rare 3⁢ He for refrigeration, simplifying cryogenic systems, and providing orders-of-magnitude higher cooling power, lending the flexibility needed for novel quantum sensing and hybrid experiments. Using low-loss niobium trilayer junctions, we realize a qubit at 72 GHz cooled to 0.87 K using only 4 ⁢He. We perform Rabi oscillations to establish control over the qubit state, and measure relaxation and dephasing times of 15.8 and 17.4 ns, respectively. This demonstration of a millimeter-wave quantum emitter offers exciting prospects for enhanced sensitivity thresholds in high-frequency photon detection, provides new options for quantum transduction and for scaling up and speeding up quantum computing, enables integration of quantum systems where 3 ⁢He refrigeration units are impractical, and, importantly, paves the way for quantum experiments exploring a novel energy range.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of High Speed Optical and Magnetic Interactions in Superconducting Nanowire Single Photon Detectors

Single-photon detectors are essential tools for quantum photonics. The ideal single photon detector would exhibit a quantum efficiency (QE) of 100% (i.e. no false negatives), zero dark photon counts per second (i.e. no false positives), zero dead time (i.e. the detector is capable of detecting one photon immediately after another), and zero jitter (i.e. the electrical signal produced by the detector perfectly reproduces the timing of the input photon signal). Commercially available avalanche photodiodes (APDs) have generally performed reasonably well for visible wavelengths but they perform poorly at longer wavelengths. For wavelengths spanning the near- ultraviolet (UV) to the mid- infrared (IR), superconducting nanowire single photon detectors (SNSPDs) can exhibit quantum efficiencies exceeding 90% with dark count rates and timing jitter roughly an order of magnitude less than is typically seen in APDs. While SNSPDSs are now commercially available from several small businesses, fundamental questions about the nature of photon interactions with superconducting nanostructures remain.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantum Imaging with X-rays

Quantum imaging encompasses a broad range of methods that exploit the quantum properties of light to capture information about an object. One such approach involves using a two-photon quantum state, where only one photon interacts with the object being imaged while its entangled partner carries spatial or temporal information. To implement this technique, it is necessary to generate specific quantum states of light and detect photons at the single-photon level. While this method has been successfully demonstrated in the visible electromagnetic spectrum, extending it to X-rays has faced significant challenges due to the difficulties in producing a sufficient rate of X-ray photon pairs and detecting them with adequate resolution. Here, we demonstrate record high rates of correlated X-ray photon pairs produced via a spontaneous parametric down-conversion process and we employ these photons to perform quantum correlation imaging of several objects, including a biological sample (E. cardamomum seedpod). Notably, we report an unprecedented detection rate of about 6,300 pairs per hour and the observation of energy anti-correlation for the X-ray photon pairs. We also present a detailed analysis of the properties of the down-converted X-ray photons, as well as a comprehensive study of the correlation imaging formation, including a study of distortions and corrections. These results mark a substantial advancement in X-ray quantum imaging, expanding the possibilities of X-ray quantum optical technologies, and illustrating the pathway towards enhancing biological imaging with reduced radiation doses.

Gofron, Kaz [ORNL] (ORCID:0000000314415736)↗

CH(A, B-X) fluorescence from vacuum ultraviolet excitation of CH3

The fluorescence due to single-photon and two-photon excitation of CH3 produced by the reaction of CH4 with F or Cl in a flow tube is investigated experimentally. The excitation source is an excimer laser operating with pulse duration 6 nsec and repetition rate 20 Hz, and the fluorescence is observed using a 0.25-m spectrometer and a 1024-channel diode array; the results are presented graphically. Emission is detected at 157 nm (with approximate cross section 8 x 10 to the -19th sq cm) and 193 nm, but not at 248 nm. The applicability of these data to studies of hydrocarbon combustion, the methane oxidation cycle in the atmosphere, interstellar molecule formation, and diamond film fabrication is indicated.

Ye, Chao↗

Quantum Probability Cancellation Due to a Single-Photon State

When an N-photon state enters a lossless symmetric beamsplitter from one input port, the photon distribution for the two output ports has the form of Bernouli Binormial, with highest probability at equal partition (N/2 at one outport and N/2 at the other). However, injection of a single photon state at the other input port can dramatically change the photon distribution at the outputs, resulting in zero probability at equal partition. Such a strong deviation from classical particle theory stems from quantum probability amplitude cancellation. The effect persists even if the N-photon state is replaced by an arbitrary state of light. A special case is the coherent state which corresponds to homodyne detection of a single photon state and can lead to the measurement of the wave function of a single photon state.

Ou, Z. Y.↗

Interferometric Quantum-Nondemolition Single-Photon Detectors

Two interferometric quantum-nondemolition (QND) devices have been proposed: (1) a polarization-independent device and (2) a polarization-preserving device. The prolarization-independent device works on an input state of up to two photons, whereas the polarization-preserving device works on a superposition of vacuum and single- photon states. The overall function of the device would be to probabilistically generate a unique detector output only when its input electromagnetic mode was populated by a single photon, in which case its output mode would also be populated by a single photon. Like other QND devices, the proposed devices are potentially useful for a variety of applications, including such areas of NASA interest as quantum computing, quantum communication, detection of gravity waves, as well as pedagogical demonstrations of the quantum nature of light. Many protocols in quantum computation and quantum communication require the possibility of detecting a photon without destroying it. The only prior single- photon-detecting QND device is based on quantum electrodynamics in a resonant cavity and, as such, it depends on the photon frequency. Moreover, the prior device can distinguish only between one photon and no photon. The proposed interferometric QND devices would not depend on frequency and could distinguish between (a) one photon and (b) zero or two photons. The first proposed device is depicted schematically in Figure 1. The input electromagnetic mode would be a superposition of a zero-, a one-, and a two-photon quantum state. The overall function of the device would be to probabilistically generate a unique detector output only when its input electromagnetic mode was populated by a single photon, in which case its output mode also would be populated by a single photon.

Kok, Peter↗

Non-Geiger-Mode Single-Photon Avalanche Detector with Low Excess Noise

This design constitutes a self-resetting (gain quenching), room-temperature operational semiconductor single-photon-sensitive detector that is sensitive to telecommunications optical wavelengths and is scalable to large areas (millimeter diameter) with high bandwidth and efficiencies. The device can detect single photons at a 1,550-nm wavelength at a gain of 1 x 10(exp 6). Unlike conventional single photon avalanche detectors (SPADs), where gain is an extremely sensitive function to the bias voltage, the multiplication gain of this device is stable at 1 x 10(exp 6) over a wide range of bias from 30.2 to 30.9 V. Here, the multiplication gain is defined as the total number of charge carriers contained in one output pulse that is triggered by the absorption of a single photon. The statistics of magnitude of output signals also shows that the device has a very narrow pulse height distribution, which demonstrates a greatly suppressed gain fluctuation. From the histograms of both pulse height and pulse charge, the equivalent gain variance (excess noise) is between 1.001 and 1.007 at a gain of 1 x 10(exp 6). With these advantages, the device holds promise to function as a PMT-like photon counter at a 1,550- nm wavelength. The epitaxial layer structure of the device allows photons to be absorbed in the InGaAs layer, generating electron/hole (e-h) pairs. Driven by an electrical field in InGaAs, electrons are collected at the anode while holes reach the multiplication region (InAlAs p-i-n structure) and trigger the avalanche process. As a result, a large number of e-h pairs are created, and the holes move toward the cathode. Holes created by the avalanche process gain large kinetic energy through the electric field, and are considered hot. These hot holes are cooled as they travel across a p -InAlAs low field region, and are eventually blocked by energy barriers formed by the InGaAsP/ InAlAs heterojunctions. The composition of the InGaAsP alloy was chosen to have an 80 meV valance band offset with InAlAs, which is high enough to hinder the transport of the already cooled holes. Being stopped by the energy barrier, holes are accumulated at the junctions to shield the electric field, resulting in a decrease of the electric field in the multiplication region. Because the impact ionization rate is extremely sensitive to the magnitude of the electric field, the field-screening effect drastically reduces the impact ionization rate and quenches the output signals. After the avalanche pulse signal is self-quenched, the accumulated holes at the InGaAsP/ InAlAs interface escape the energy barrier through thermal excitation and tunneling and finally leave the device. The device is thus reset and ready for subsequent photon detection. This recovery time is controlled by the height of the energy barrier and the hole-cooling rate.

Zhao, Kai↗

Quantum Entanglement Molecular Absorption Spectrum Simulator

Quantum Entanglement Molecular Absorption Spectrum Simulator (QE-MASS) is a computer program for simulating two photon molecular-absorption spectroscopy using quantum-entangled photons. More specifically, QE-MASS simulates the molecular absorption of two quantum-entangled photons generated by the spontaneous parametric down-conversion (SPDC) of a fixed-frequency photon from a laser. The two-photon absorption process is modeled via a combination of rovibrational and electronic single-photon transitions, using a wave-function formalism. A two-photon absorption cross section as a function of the entanglement delay time between the two photons is computed, then subjected to a fast Fourier transform to produce an energy spectrum. The program then detects peaks in the Fourier spectrum and displays the energy levels of very short-lived intermediate quantum states (or virtual states) of the molecule. Such virtual states were only previously accessible using ultra-fast (femtosecond) laser systems. However, with the use of a single-frequency continuous wave laser to produce SPDC photons, and QEMASS program, these short-lived molecular states can now be studied using much simpler laser systems. QE-MASS can also show the dependence of the Fourier spectrum on the tuning range of the entanglement time of any externally introduced optical-path delay time. QE-MASS can be extended to any molecule for which an appropriate spectroscopic database is available. It is a means of performing an a priori parametric analysis of entangled photon spectroscopy for development and implementation of emerging quantum-spectroscopic sensing techniques. QE-MASS is currently implemented using the Mathcad software package.

Nguyen, Quang-Viet↗