Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Short circuiting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Data-Driven Cyber-Attack Detection for PV Farms via Time-Frequency Domain Features

The internetworking of grid-connected power electronics converters (PECs) in photovoltaic (PV) farms has inevitably expanded the cyber-attack surfaces. Here this paper presents a comprehensive study on cyber-attack detection and diagnosis for PEC-enabled PV farms via single waveform sensor to distinguish between normal conditions, open-circuit faults, short-circuit faults, and cyber-attacks. To our knowledge, this has not been attempted before. Firstly, we propose frequency-domain magnitude-based residuals to identify short-circuit faults and a time-domain mean current vector-based feature to distinguish open-circuit faults from other threats. These features can fully reflect the specific physical characteristics of PV farms during threat duration. Secondly, unlike micro phasor measurement units (µPMU) and raw electric waveform-based methods, the proposed innovative features can address novel cyber-attacks that are excluded from the training process. Thirdly, an online hardware-in-the-loop (HIL) testbed using the OPAL-RT real-time digital simulator has verified the effectiveness. The monitoring system runs in real-time while using HIL as an operational solar farm and a National Instruments (NI) data acquisition card as the electric waveform sensor at the point of coupling.

42 ENGINEERING↗

Ensuring a Nuclear Power Plant Safe State Following an EMP Event - Task 7 Deliverable: EMP Testing of Secondary Coupling to Instrumentation Cables

Sandia National Laboratories performed tests to address the potential vulnerability concerns of a coupled High-Altitude Electromagnetic Pulse (HEMP) inducing secondary coupling onto critical instrumentation and control cables in a nuclear power plant, with specific focus on early-time HEMP. Three types of receiving cables in nine configurations were tested to determine transfer functions between two electrically separated cables referenced to the common mode input current on the transmitting cable. One type of transfer function related the input short circuit current and resulting open circuit voltage on the receiving cable. The other transfer function related the input short circuit current and the resulting short circuit current on the receiving cable. A 500 A standard HEMP waveform was input into the transfer functions to calculate peak coupling values on the receiving cables. The highest level of coupling using the standard waveform occurred when cables were in direct contact, with a peak short circuit current of 85 A and open circuit voltage of 9.8 kV, while configurations with separated cables predicted coupling levels of less than 5 A or 500 V.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Frequency Stability Enhancement in a Fully Solar Power Grid: A Case Study on the Saudi Model

Recently, renewable energy sources (RES) such as solar photovoltaic (PV) have been recognized for their significant potential. Several studies have explored the issue of frequency stability with high RES penetration. A significant observation related to this issue is the decline in the weighted short circuit ratio (WSCR), which has the potential to adversely affect system stability. This research uniquely focuses on the gradual transition of the Saudi Electricity Company (SEC) system to a fully integrated solar PV grid, offering insight and methodology that can be adapted for other power systems. While a variety of mitigation methods are available, synchronous condensers (SC) were used in this study to stabilize grid frequency, and their implementation has been shown to improve the overall performance of the system. In response to the observed decline in WSCR, a comprehensive short circuit analysis was applied across all regions in the Saudi power grid model to evaluate the reduction in short circuit power and highlight areas requiring enhancement. Finally, scenarios illustrating frequency response with a gradual increase in SCR were analyzed, with the objective of establishing a stable, fully solar PV power system that is resilient to sudden power grid disturbances.

14 SOLAR ENERGY↗

Impedance sources (Z sources) with inherent fault protection for resilient and fire-free electricity grids

Modern societies would not survive without electricity and at the same time electrical faults could cause and have caused many catastrophes—mainly deadly fires—to our societies. There are two types of electricity sources: the voltage source such as generators, charged batteries and capacitors, and the current source such as charged inductors, current-regulated rectifiers, and superconducting magnetic energy storage. An “ideal” voltage source—that is often-sought-or-intentionally engineered—generates a constant voltage irrespective of its load current, and an “ideal” current source injects a constant current irrespective of its load voltage. However, two problems exist: (1) voltage or current sources do not represent many emerging natural/renewable energy sources such as wind turbine generators, photovoltaic cells, and fuel cells, whose output voltage and current are strongly dependent on each other, and (2) a short-circuit fault to an artificially-made and controlled “ideal” voltage source or an open-circuit fault to an “ideal” current source can cause catastrophic failures of the source itself and its surrounding circuits due to large (theoretically infinite) short-circuit current or open-circuit voltage. Here we introduce an impedance source concept to represent, characterize, and model those electricity sources whose output voltage and current are strongly dependent on each other. First, we found that many electric sources with no feedback (or active) control of their output voltage and/or current are a natural impedance source with inherent fault protection at short-circuit or open-circuit faults. Second, any electrical source can be artificially controlled to mimic a natural impedance source. Finally, we show how to apply natural impedance sources and nature-mimicking artificially-controlled sources to the electricity grid—the most complex machine ever made by human beings—to realize electricity grids that are naturally stable, self-protected against electrical faults, and resilient to natural and human-made events.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Value Proposition of UV-Absorbers in PV Module Encapsulation

Various common crystalline silicon cell technologies were exposed to UVA radiation (1.24 Wm-2 nm-1 at 340 nm peak) on the front and back faces at 45 degrees Celsius for periods up to 3000 h, representing about 3 y of solar exposure in Phoenix, Arizona, USA. The resulting degradation of the open-circuit voltage and short-circuit current is presented. Of the various cell types examined, significant levels of degradation were seen in all cases. Less degradation was generally found after UV irradiation of cell fronts and older cell types, whereas a bifacial PERC type exposed on the rear showed about 25% degradation in short circuit current, attributable to lack of a diffused surface field. Selected cells were exposed to UV irradiation with the addition of long pass UV filters to replicate UV-absorbers in encapsulants. Modern cell designs are sensitive to UV-ID because of reduced or eliminated front and back surface field and increased dependence on high quality surface passivation. Single transformation of the independent variable (t, kW h/m^2) could be used to achieve a linear model of the data to extrapolate to 50 y. Solar Advisor Model (SAM) shows appropriate filtering of UV-irradiation can improve LCOE and net present value of plant. Some advanced cell types are seen to be UV-resistant (cell level solutions also exist). Solutions therefore exist on the cell, glass, and encapsulant level. Changes over time in each of these would also need to be considered (solarization, encapsulant browning...).

ENGINEERING,SOLAR ENERGY↗

Robust Disturbance Rejection Rotor Current Control of Doubly-Fed Induction Generators

This article proposes a robust transient disturbance rejection current controller (TDRCC) to improve the transient performance of doubly-fed induction generators (DFIGs) in wind turbines during grid disturbances, such as short circuits. Here, the proposed robust TDRCC replaces the proportional-integral-derivative (PID) current controllers conventionally used in the vector control scheme of the DFIG rotor side converter (RSC). The TDRCC estimates the transient disturbances caused by grid faults or other external disturbances and provides compensation to the DFIG rotor voltage in the current control loops of the RSC to improve the robustness of the controller to disturbance. A sliding-mode current controller (SMCC) is also designed to highlight the transient performance improvement of the DFIG using the TDRCC over the state-of-the-art control methods during grid short circuit faults. Simulation studies are conducted in PSCAD/EMTDC for a 3.6-MW DFIG wind turbine with the proposed TDRCC, the conventional PI controller, and the SMCC, respectively during the most severe balanced three-phase grid short circuit fault specified by the U.S. grid code as well as an unbalance single-phase grid short circuit fault. Hardware experiments are conducted on a 200-W DFIG wind turbine emulator with the three different controllers for the same three-phase short circuit fault. Simulation and hardware experiment results show that the TDRCC reduces the peak rotor current significantly when compared with the PI and SMCC controlled DFIG system and, therefore, would help prolong the lifespan of the DFIG's power electronics and reduce maintenance costs.

42 ENGINEERING↗

Device Performance of Emerging Photovoltaic Materials (Version 3)

Abstract Following the 2nd release of the “Emerging PV reports,” the best achievements in the performance of emerging photovoltaic devices in diverse emerging photovoltaic research subjects are summarized, as reported in peer‐reviewed articles in academic journals since August 2021. Updated graphs, tables, and analyses are provided with several performance parameters, e.g., power conversion efficiency, open‐circuit voltage, short‐circuit current density, fill factor, light utilization efficiency, and stability test energy yield. These parameters are presented as a function of the photovoltaic bandgap energy and the average visible transmittance for each technology and application, and are put into perspective using, e.g., the detailed balance efficiency limit. The 3rd installment of the “Emerging PV reports” extends the scope toward triple junction solar cells.

14 SOLAR ENERGY↗

Advancing PV material performance using nanoscale opto-electrical characterization

The purpose of this program was to improve the efficiency of photovoltaics by characterizing their optoelectronic properties at the nanoscale. We investigated Copper Indium Gallium Selenide (CIGS) materials produced by Dow. We modified an atomic force microscope (AFM) to work with a highly controlled environment under controlled illumination at the probe to study the main power conversion efficiency determining parameters for photovoltaics of open circuit voltage, short circuit current, carrier lifetime and diffusion length, and band alignment at interfaces and defects with sub 10nm spatial resolution of their device materials.

14 SOLAR ENERGY↗

Gas-driven short disconnection mitigates thermal runaway in Li-ion batteries under mechanical abuse

Mechanical abuse poses a critical safety risk to Li-ion batteries by inducing internal short circuits that initiate thermal runaway. Remarkably, voltage recovery frequently emerges during thermal runaway initiation, a phenomenon that conventional theories fail to explain. Here, our study develops a new multiphysics mechanism to explain voltage recovery, termed gas-driven short disconnection, whereby internal gas pressure mechanically disengages short-circuit contacts and causes the cell voltage to rebound. This mechanism incorporates gas generation and its structural impact on the short circuit. Real-time optical and thermal imaging and X-ray computed tomography reveal fluid-structure interaction between internal gas flow and adjacent shorting contacts. We establish a mechanistic framework linking gas-driven short disconnection to cell-level voltage and temperature responses, elucidating the extension–truncation pattern of voltage recovery. Furthermore, thermal regime maps show that a voltage recovery duration exceeding 5 s correlates with limited temperature rise below 150 °C, indicating that sustained short-circuit disconnection suppresses Joule heating. Additionally, a dimensionless criterion is deduced from scaling analysis for physical plausibility of gas-driven short disconnection in mechanically abused cells. This finding inspires smart venting control, which regulates gas release to maintain the internal pressure while dissipating gas enthalpy, thereby providing a device-level strategy for thermal runaway mitigation.

Gas-driven short disconnection↗

Universal free-energy landscape produces efficient and reversible electron bifurcation

For decades, it was unknown how electron-bifurcating systems in nature prevented energy-wasting short-circuiting reactions that have large driving forces, so synthetic electron-bifurcating molecular machines could not be designed and built. The underpinning free-energy landscapes for electron bifurcation were also enigmatic. We predict that a simple and universal free-energy landscape enables electron bifurcation, and we show that it enables high-efficiency bifurcation with limited short-circuiting (the EB scheme). The landscape relies on steep free-energy slopes in the two redox branches to insulate against short-circuiting using an electron occupancy blockade effect, without relying on nuanced changes in the microscopic rate constants for the short-circuiting reactions. The EB scheme thus unifies a body of observations on biological catalysis and energy conversion, and the scheme provides a blueprint to guide future campaigns to establish synthetic electron bifurcation machines.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Developing inductively driven diagnostic X-ray sources to enable transformative radiography and diffraction capabilities on Z

Penetrating X-rays are one of the most effective tools for diagnosing high energy density experiments, whether through radiographic imaging or X-ray diffraction. To expand the X-ray diagnostic capabilities at the 26-MA Z Pulsed Power Facility, we have developed a new diagnostic X-ray source called the inductively driven X-pinch (IDXP). This X-ray source is powered by a miniature transmission line that is inductively coupled to fringe magnetic fields in the final power feed. The transmission line redirects a small amount of Zs magnetic energy into a secondary cavity where 150+ kA of current is delivered to a hybrid X-pinch. In this report, we describe the multi-stage development of the IDXP concept through experiments both on Z and in a surrogate setup on the 1 MA Mykonos facility. Initial short-circuit experiments to verify power ow on Z are followed by short-circuit and X-ray source development experiments on Mykonos. The creation of a radiography-quality X-pinch hot spot is verified through a combination of X-ray diode traces, laser shadowgraphy, and source radiography. The success of the IDXP experiments on Mykonos has resulted in the design and fabrication of an IDXP for an upcoming Z experiment that will be the first-ever X-pinch fielded on Z. We have also pursued the development of two additional technologies. First, the extended convolute post (XCP) has been developed as an alternate method for powering diagnostic X-pinches on Z. This concept, which directly couples the current owing in one of the twelve Z convolute posts to an X-pinch, greatly increases the amount of available current relative to an IDXP (900 kA versus 150 kA). Initial short-circuit XCP experiments have demonstrated the efficacy of power ow in this geometry. The second technology pursued here is the inductively driven transmission line (IDTL) current monitor. These low-current IDTLs seek to measure the current in the final power feed with high fidelity. After three generations of development, IDTL current monitors frequently return cleaner current measurements than the standard B-dot sensors that are fielded on Z. This is especially true on high-inductance experiments where the harshest conditions are created in the nal power feed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-Time Model-Adaptive Relaying Applied to Microgrid Protection

In microgrids, the short-circuit current magnitude is significantly limited by more than an order of magnitude due to the relatively small inverter-based resources. Commercially available protective devices for distribution cannot reliably protect a microgrid due to their dependence on the magnitude of the fault current. Moreover, overcurrent relays typically cannot function properly for a microgrid because they are incapable of detecting faults and/or performing the coordination between the relays in inverter-based microgrids operated in the islanded mode. This paper proposes a model-adaptive relay designed to adjust the relay curves based on the available generation and the network topology. The proposed method runs a real-time model of the microgrid, which gathers information from the network to calculate the available short-circuit current in the specified node. The fault current from the model is then used for the adaptive algorithm to calculate the relay settings, considering coordination with the downstream fuses and upstream reclosers. This work presents the validation of the proposed method in Hardware-in-the-Loop, in a hardware testbed as well as field deployed in a real microgrid in East-Tennessee.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Examples of X-Ray Characterization Techniques in Energy Storage Research

Lithium-ion batteries have revolutionized the portable electronics and transportation sectors. Their performance is often critically dependent on the crystal structures of the anode and cathode electrode materials, which must enable the transport and reversible storage of lithium ions into and out of the lattice. Because lithium is a low-Z element, characterization of materials for lithium-ion batteries can be particularly challenging. Regardless, X-ray techniques enable analysis of material structures to better understand how battery materials perform and degrade, particularly when combined with other materials characterization and electrochemical characterization techniques. While X-ray techniques are most often used in battery research for phase identification of crystal structures, X-ray characterization techniques are also used for a wide variety of other purposes. I will discuss several examples from my research with various collaborators on several projects that highlight the impact that X-ray characterization techniques can have on battery research. The first example will focus on low-temperature microwave-assisted solvothermal synthesis of vanadium-doped LiFePO4 cathode materials for lithium-ion batteries. (1,2) Through a combination of electrochemical and materials characterization, we determined that low temperature synthesis resulted in metastable phases that enabled incorporation of higher dopant levels than resulting from high-temperature synthesis of thermodynamically stable phases. Rietveld refinement of X-ray diffraction data enabled understanding of how lattice parameters changed with doping levels and synthesis temperature. X-ray absorption near edge spectroscopy enabled understanding of the vanadium and iron oxidation states to confirm how vacancies in the structure caused by doping were charge compensated. This was important to understand because the literature suggests doping can improve LiFePO4 electrical conductivity, which improves battery charge and discharge rates. The second example will focus on understanding residual strain in lithium metal anodes. Lithium-ion batteries typically use graphite anodes, but the charge-storage capacity can be theoretically improved ~10x by using lithium metal as the anode material instead. However, lithium anodes suffer from growth of high-aspect-ratio features, such as dendrites, that can pierce nanoporous polymer separators and lead to short circuits and fires. External pressure is commonly applied to cells to enable better morphological control. We hypothesized that applied pressure may promote strain and possibly work hardening during electrochemical cycling, which motivated us to look for evidence of residual strain in lithium metal cycled under applied pressure using X-ray diffraction and sin2(..psi..) analysis. We found that lithium electrodeposited under high pressure exhibited in-plane compressive strain and that that lithium electrodeposited under low pressure did not. (3) The residual strain that accompanies electrodeposition under high pressure may lead to work hardening, which may explain how a soft metal like lithium can puncture separators and why higher pressure does not always decrease short circuits. (4-6) References: 1) Harrison, K. L.; Manthiram, A. Microwave-Assisted Solvothermal Synthesis and Characterization of Metastable LiFe1- x (VO) x PO4 Cathodes. Inorganic chemistry 2011, 50(8), 3613-3620. 2) Harrison, K. L.; Bridges, C. A.; Paranthaman, M. P.; Segre, C. U.; Katsoudas, J.; Maroni, V. A.; Idrobo, J. C.; Goodenough, J. B.; Manthiram, A. Temperature Dependence of Aliovalent-Vanadium Doping in LiFePO4 Cathodes. Chemistry of Materials 2013, 25(5), 768-781. 3) Rodriguez, M. A.; Harrison, K. L.; Goriparti, S.; Griego, J. J.; Boyce, B. L.; Perdue, B. R. Use of a Be-Dome Holder for Texture and Strain Characterization of Li Metal Thin Films via Sin2 (..psi..) Methodology. Powder Diffraction 2020, 35(2), 89-97. 4) Jungjohann, K. L.; Gannon, R. N.; Goriparti, S.; Randolph, S. J.; Merrill, L. C.; Johnson, D. C.; Zavadil, K. R.; Harris, S. J.; Harrison, K. L. Cryogenic Laser Ablation Reveals Short-Circuit Mechanism in Lithium Metal Batteries. ACS Energy Letters 2021, 6(6), 2138-2144. 5) Harrison, K. L.; Merrill, L. C.; Long, D. M.; Randolph, S. J.; Goriparti, S.; Christian, J.; Warren, B.; Roberts, S. A.; Harris, S. J.; Perry, D. L. Cryogenic Electron Microscopy Reveals That Applied Pressure Promotes Short Circuits in Li Batteries. Iscience 2021, 24(12). 6) Harrison, K. L.; Goriparti, S.; Merrill, L. C.; Long, D. M.; Warren, B.; Roberts, S. A.; Perdue, B. R.; Casias, Z.; Cuillier, P.; Boyce, B. L. Effects of Applied Interfacial Pressure on Li-Metal Cycling Performance and Morphology in 4 M LiFSI in DME. ACS Applied Materials & Interfaces 2021, 13(27), 31668-31679.

batteries↗

Experimental investigation of flow distribution in enhanced geothermal systems with deep eutectic solvent

Geothermal energy has been recognized as a valuable alternative to fossil fuels and nuclear power, as it is renewable and reliable. Enhanced Geothermal Systems (EGSs) have the potential to expand geothermal energy production by enabling access to previously untapped geothermal resources. Geothermal short-circuiting poses a significant challenge to EGS development, leading to reduced heat extraction. Deep Eutectic Solvent (DES) exhibits favorable thermal and rheological properties, making it a candidate for geothermal applications. Here, this paper examines Choline Chloride-Based Deep Eutectic Solvent (DES) as a working fluid in geothermal applications and its potential to mitigate geothermal short-circuiting. Hydraulic experiments using a dual fracture flow loop were conducted at high temperatures. The results showed that DES exhibited higher differential pressure behavior compared to water. Flow distribution results revealed that DES enhances flow allocation within the small fracture, particularly when a temperature difference exists between fractures. Specifically, DES increased flow distribution by an average of 11% when the temperature difference was 85°C, and by 13% when the difference was 45°C, relative to water. These findings suggest that DES responds to thermal fracture differences, making it a potential remedy to address geothermal short-circuiting.

15 GEOTHERMAL ENERGY↗

Design, Deployment, and Characterization of the World’s First Flexible Large Power Transformer

GE Research and its partner Prolec GE have designed, built and deployed in the field the world’s first flexible power transformer. The flexible power transformer is a transmission class 3-phase autotransformer configurable in impedance and in voltage which allows it to serve as a universal spare for multiple units in a given fleet. However, the key innovation in this new concept is the online adjustable leakage impedance which allows the transformer to change its impedance without interrupting the transmission line operation. The flexible power transformer can be designed with up to three low voltage transmission class ratings and up to 12 impedance values changeable both online and offline. This report provides an overview of the design, manufacturing, testing, and commissioning of the 165kV, 60MVA prototype built including the results of the field performance validation tests. The prototype was specified in collaboration with Cooperative Energy, the utility host. It was designed and tested in the factory according to IEEE standard C57.12.00 and followed all protocols for transportation, installation, and commissioning of a power transformer. In addition to the prototype, a flexible protection system capable of automatically adjusting its settings upon the transformer impedance was also developed and deployed in the for testing and validation. On September 3, 2021 the prototype was energized in Cooperative Energy’s substation in Columbia, Mississippi to become the world’s first flexible power transformer in operation. Its performances and impact on the grid operation were demonstrated through different field tests. Results obtained confirm that the impedance of the flexible transformer can be varied under load through its full range, from 4.3% to 9.3%, without adverse impacts on the line operation, the protection system, the transformer stability and health condition. Results also proved that the flexible transformer is very effective in controlling power transfer through the line or load sharing between units operating in parallel. Indeed, it was proven that higher impedances decrease the thruput power of the transformer while lower impedances increase it. Up to 26MW was controllable on a line loading of 45MVA. It was also possible to demonstrate that the variation of the transformer impedance has no effect on the circulating current between units in parallel, except a minor transient during the impedance change. It was also proven that the flexible protection relay can update its protection settings automatically when the impedance change was detected. The prototype has operated continuously for more than 12 months now with a peak load exceeding 50MVA corresponding to >80% of its ONAN power rating. No alarm, trip or sign of failure has been reported by the utility. In addition to the development and deployment of the flexible transformer prototype, investigations were carried out on new nanodielectric fluids to replace the mineral oil used in power transformers with the goal of reducing their footprint and weight. The key parameters that were targeted for improvement included the breakdown voltage to reduce clearances between windings and tank hence the footprint; viscosity and thermal conductivity to increase the cooling efficiency and therefore to reduce the winding material. Several nanodielectric mixtures with mineral oil including with alumina (Al2O3), titania (TiO2) and Borum Nitrate (BN) with different surfactants have been analyzed and tested. Unfortunately, despite encouraging results no nanofluid candidate has been found viable to replace mineral oil. With the formulations tested, breakdown voltages are generally similar to mineral oil at lower particle contents and worse at higher particle contents. Viscosity appreciably increased at particles concertation over 2 wt% and thermal conductivity increased slightly at 5wt% and appears to be 10-15% higher at 10 wt% particle content. It is recommended to continue investigations to find solutions that can help increase the power density of future flexible power transformers. Flexible power transformers can significantly help the future power grid by providing more flexibility and resiliency. Indeed, by providing voltage and impedance flexibility, flexible power transformers reduce the need for multiple spares, hence inventory costs for utilities. With their online controllable impedance, they can provide support to the grid and help manage short-circuit currents, power flow, line congestion, and grid stability which will become more important with higher penetrations of intermittent renewable resources. During the field validation tests, it was demonstrated that up to 26MW was controllable on a line loading of 45MVA when the transformer impedance was varied from its minimum to its maximum range. Also, with the impedance range, the short-circuit currents could be reduced by up to 38% at the load side of the transformer. With its controllable impedance, flexible transformers can be used in future strategies of grid resilience to help better prepare the grid to face forecasted severe events including storms, heat waves and contingencies. The flexible power transformers can also find role in other applications including high voltage transmission cables such as offshore wind farms where solutions for energizing the cables and managing the reactive power are of critical importance. The designed flexible power transformer is now fully validated and ready for commercialization. Further analysis on the benefits of flexible power transformers for grid stability and short-circuit management including current limiting capability, reclosure and line restoration, control of inrush current, sizing of flexible AC components (FACTS) would help its rapid adoption by the industry.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data‐Driven Safety Risk Prediction of Lithium‐Ion Battery

Abstract Inevitable safety issues have pushed battery engineers to become more conservative in battery system design; however, battery‐involved accidents still frequently are reported in headlines. Identifying, understanding, and predicting safety risks have become priorities to further accelerate technology and industry development. However, diverse loading scenarios, significantly varied stress‐induced short circuit mechanisms, and highly coupled mechanical–electrochemical safety behaviors have remained grand challenges. Herein, the safety risk is termed as the probability of the mechanical triggering of an internal short circuit, to reflect the safety related behaviors of lithium‐ion batteries. Based on a mechanical model and experimental results, a sufficient dataset is generated consisting of strain states and their corresponding safety risks, covering both cylindrical and pouch cells, various states of charges, and loading conditions. Machine‐learning tools combined with the established finite element mechanical model are applied to predict the safety risks of the cells. The results achieve a high level of accuracy on the test data (the relative error of the average short circuit prediction deviation is less than 6.2%.). This work underpins the safety risk concept and highlights the promise of physics combined with data‐driven modeling methodology to predict the safety behaviors of energy storage systems.

Jia, Yikai↗

Fault localization in a microfabricated surface ion trap using diamond nitrogen-vacancy center magnetometry

Here, as quantum computing hardware becomes more complex with ongoing design innovations and growing capabilities, the quantum computing community needs increasingly powerful techniques for fabrication failure root-cause analysis. This is especially true for trapped-ion quantum computing. As trapped-ion quantum computing aims to scale to thousands of ions, the electrode numbers are growing to several hundred, with likely integrated photonic components also adding to the electrical and fabrication complexity, making faults even harder to locate. In this work, we used a high-resolution quantum magnetic imaging technique, based on nitrogen-vacancy centers in diamond, to investigate short-circuit faults in an ion trap chip. We imaged currents from these short-circuit faults to ground and compared them to intentionally created faults, finding that the root cause of the faults was failures in the on-chip trench capacitors. This work, where we exploited the performance advantages of a quantum magnetic sensing technique to troubleshoot a piece of quantum computing hardware, is a unique example of the evolving synergy between emerging quantum technologies to achieve capabilities that were previously inaccessible.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electrochemically induced fracture in LLZO: How the interplay between flaw density and electrostatic potential affects operability

Fracture and short circuit in the Li 7 La 3 Zr 2 O 12 (LLZO) solid electrolyte are two key issues that prevent its adoption in battery cells. In this paper, we utilize phase-field simulations that couple electrochemistry and fracture to evaluate the maximum electric potential that LLZO electrolytes can support as a function of crack density. In the case of a single crack, we find that the applied potential at the onset of crack propagation exhibits inverse square root scaling with respect to crack length, analogous to classical fracture mechanics. Here, we further find that the short-circuit potential scales linearly with crack length. In the realistic case where the solid electrolyte contains multiple cracks, we reveal that failure fits the Weibull model. The failure distributions shift to favor failure at lower overpotentials as areal crack density increases. Furthermore, when flawless interfacial buffers are placed between the applied potential and the bulk of the electrolyte, failure is mitigated. When constant currents are applied, current focuses in near-surface flaws, leading to crack propagation and short circuit. We find that buffered samples sustain larger currents without reaching unstable overpotentials and without failing. Our findings suggest several mitigation strategies for improving the ability of LLZO to support larger currents and improve operability.

25 ENERGY STORAGE↗