Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sensor Network Design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

AOI [3]: Smart Refractory Sensor Systems for Wireless Monitoring of Temperature, Health, and Degradation of Slagging Gasifiers

The objective of the work was to develop refractory “smart bricks”, which would contain embedded temperature, strain/stress, and spallation sensors throughout the volume of highchromia (-Cr 2 O 3 ) refractory brick. The proposed work included work to interconnect the sensors to the reactor exterior, where the sensor signals may be processed by low-power electronics and transmitted wirelessly to a central processing hub. The data processing and wireless transmitter hardware was specifically designed to be isolated (with low power consumption) and to be adaptable to future implementation of energy-harvesting strategies for extended life. Finally, the collected data was incorporated into a model to estimate refractory degradation, a technique that could help monitor the health of the refractory in real-time. The long-term goal of this program was to demonstrate high-temperature, wireless sensor arrays for in situ three-dimensional (3-D) refractory monitoring or mapping for slagging gasification systems. The research was in collaboration with HarbisonWalker International (HWI) Technology Center in West Mifflin, PA. HWI is a leading developer and manufacturer of ceramic refractory products for high-temperature applications. The work completed focused on the following areas: 1) Investigation of the chemical stability, microstructural evolution, grain growth kinetics, degree of homogeneity (quantitative image analysis), and electrical properties of refractory oxide-silicide composites at temperatures between 750-1450ºC; 2) Fabrication of silicide-alumina composite and oxide thermocouples and thermistor preforms and the development of techniques to embed them into high-chromia refractory bricks to form “smart bricks”; 3) Utilization of commercial off-the-shelf discrete components to prototype circuits for interfacing between smart brick sensors and the wireless sensor network. The prototypes were then used to design an integrated circuit for thermistor, thermocouple, and capacitive-based smart brick sensor interfacing; 4) Interfacing of the smart bricks with embedded sensors with wireless motes thus yielding a complete signal chain. This end-to-end data collection system was tested on a furnace heated to 1350°C; 5) Development of a slag penetration model and a nonlinear unknown input filter for the data from the embedded sensors for estimating temperature and extent of slag penetration.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Graphics Processing Unit (GPU) Approach to Large Eddy Simulation (LES) for Transport and Contaminant Dispersion

Recent advances in the development of large eddy simulation (LES) atmospheric models with corresponding atmospheric transport and dispersion (AT&D) modeling capabilities have made it possible to simulate short, time-averaged, single realizations of pollutant dispersion at the spatial and temporal resolution necessary for common atmospheric dispersion needs, such as designing air sampling networks, assessing pollutant sensor system performance, and characterizing the impact of airborne materials on human health. The high computational burden required to form an ensemble of single-realization dispersion solutions using an LES and coupled AT&D model has, until recently, limited its use to a few proof-of-concept studies. An example of an LES model that can meet the temporal and spatial resolution and computational requirements of these applications is the joint outdoor-indoor urban large eddy simulation (JOULES). A key enabling element within JOULES is the computationally efficient graphics processing unit (GPU)-based LES, which is on the order of 150 times faster than if the LES contaminant dispersion simulations were executed on a central processing unit (CPU) computing platform. JOULES is capable of resolving the turbulence components at a suitable scale for both open terrain and urban landscapes, e.g., owing to varying environmental conditions and a diverse building topology. In this paper, we describe the JOULES modeling system, prior efforts to validate the accuracy of its meteorological simulations, and current results from an evaluation that uses ensembles of dispersion solutions for unstable, neutral, and stable static stability conditions in an open terrain environment.

54 ENVIRONMENTAL SCIENCES↗

A Compact Dual-Band Bowtie Antenna for RF and ISM bands Operation

Traditionally, bowtie antennas have been known to exhibit wide impedance characteristics, omnidirectional radiation patterns, and linear polarization. There is a broad range of applications from medical imaging, archaeological survey, and Ground Penetrating Radar (GPR) to trackers and sensor networks where wideband bowtie antenna designs are required for their operations. Broadening the bandwidth of bowtie antenna requires widening the flare angle of the bowtie arms, which consequently results in a large surface area that may not be suitable for space-constrained applications. Moreover, drawback attributes of the wideband bowtie designs feature inconsistent radiation pattern across the bandwidth and low signal-to-noise (SNR) ratios. As it is known, the SNR would be improved in dual- or multi-band antennas due to their reduced bandwidth. To this end, dual-band/multi-band antennas are preferred over wideband antennas in applications where more than a single frequency of interest is present. Previously, a two-port double-dipole elements was reported, whose arms were orthogonally interleaved to facilitate operation in both the standard WLAN frequency bands (J. M. Steyn and et. al, Progress in Electromagnetic Research, Vol. – 10 pp. 151-161). Even though the antenna is not very compact it does exhibit good cross-polarization, moderate gain in both frequency bands. Another dual-band bowtie antenna which excites two bands using a single transmission line was reported (Wen Chao Zheng and et. al, IEEE Trans. Antennas propag., 2014). The design was compact and did not need multi-port feeding network. In this paper, a dual-band compact bowtie antenna operating at 900 MHz (RF band) and 2.45 GHz (ISM band) using a single excitation port is introduced. It is printed on a 1.54mm thick dielectric substrate (εr = 3.38). The antenna consists of two sets of bowtie arms, a microstrip transmission line to feed the bowtie arms, and a ground plane acting as a reflector to partially reduce the back radiation. One of the bowtie arms of each frequency is printed on the top layer and the other arm, which is mirror imaged, is printed on the bottom layer of the substrate. The length of the bowtie controls the resonance frequency of the antenna and the flare angle controls the bandwidth of the antenna. The microstrip transmission line, connected to a 50 Ω SMA probe, feeds the bowtie antenna. The compact antenna can be used for both RF and ISM band applications. The bowtie arms at the lower frequency band are miniaturized by elongating their electrical lengths. The influence of miniaturizing the bowtie arms and the supporting partial ground plane is observed in the reduced peak gain and degraded front-to-back ratio. These are partly neutralized using four quarter-wave choke-slots in the ground plane with two on each side of the feeding transmission line. The proposed antenna is numerically investigated and finalized by the finite-element based full-wave EM solver, ANSYS HFSS. The miniaturization has reduced the ground plane size by ~45% and the arms size by ~41%. In addition to the size reduction benefits, the antenna shows reasonable peak gain and front-to-back ratio in both the bands. The corresponding results will be presented and discussed at the conference.

Saininad Naik↗

The resilient hybrid fiber sensor network with self-healing function

This paper presents a novel resilient fiber sensor network (FSN) with multi-ring architecture, which could interconnect various kinds of fiber sensors responsible for more than one measurands. We explain how the intelligent control system provides sensors with self-healing function meanwhile sensors are working properly, besides each fiber in FSN is under real-time monitoring. We explain the software process and emergency mechanism to respond failures or other circumstances. To improve the efficiency in the use of limited spectrum resources in some situations, we have two different structures to distribute the light sources rationally. Then, we propose a hybrid sensor working in FSN which is a combination of a distributed sensor and a FBG (Fiber Bragg Grating) array fused in a common fiber sensing temperature and vibrations simultaneously with neglectable crosstalk to each other. By making a failure to a working fiber in experiment, the feasibility and effectiveness of the network with a hybrid sensor has been demonstrated, hybrid sensors could not only work as designed but also survive from destructive failures with the help of resilient network and smart and quick self-healing actions. The network has improved the viability of the fiber sensors and diversity of measurands.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resilient Plant Monitoring System: Design, Analysis, and Performance Evaluation

Resilient monitoring systems are sensor networks that degrade gracefully under malicious attacks on their sensors, causing them to project misleading information. The goal of this paper is to design, analyze, and evaluate the performance of a resilient monitoring system intended to monitor plant conditions (normal or anomalous). The architecture developed consists of four layers: data quality assessment, process variable assessment, plant condition assessment, and sensor network adaptation. Each of these layers is analyzed by either analytical or numerical tools, and the performance of the overall system is evaluated using simulations. The measure of resiliency of the resulting system is evaluated using Kullback Leibler divergence, and is shown to be sufficiently high in all scenarios considered.

97 MATHEMATICS AND COMPUTING↗

Analysis and optimization of seismic monitoring networks with Bayesian optimal experimental design

SUMMARY Monitoring networks increasingly aim to assimilate data from a large number of diverse sensors covering many sensing modalities. Bayesian optimal experimental design (OED) seeks to identify data, sensor configurations or experiments which can optimally reduce uncertainty and hence increase the performance of a monitoring network. Information theory guides OED by formulating the choice of experiment or sensor placement as an optimization problem that maximizes the expected information gain (EIG) about quantities of interest given prior knowledge and models of expected observation data. Therefore, within the context of seismo-acoustic monitoring, we can use Bayesian OED to configure sensor networks by choosing sensor locations, types and fidelity in order to improve our ability to identify and locate seismic sources. In this work, we develop the framework necessary to use Bayesian OED to optimize a sensor network’s ability to locate seismic events from arrival time data of detected seismic phases at the regional-scale. This framework requires five elements: (i) A likelihood function that describes the distribution of detection and traveltime data from the sensor network, (ii) A prior distribution that describes a priori belief about seismic events, (iii) A Bayesian solver that uses a prior and likelihood to identify the posterior distribution of seismic events given the data, (iv) An algorithm to compute EIG about seismic events over a data set of hypothetical prior events, (v) An optimizer that finds a sensor network which maximizes EIG. Once we have developed this framework, we explore many relevant questions to monitoring such as: how to trade off sensor fidelity and earth model uncertainty; how sensor types, number and locations influence uncertainty; and how prior models and constraints influence sensor placement.

58 GEOSCIENCES↗

SNE Industrial Fieldbus Interface

Programmable logic controllers (PLCs) have very limited diagnostic and no prognostic capabilities, while current smart sensor designs do not have the capability to communicate over Fieldbus networks. The aim is to interface smart sensors with PLCs so that health and status information, such as failure mode identification and measurement tolerance, can be communicated via an industrial Fieldbus such as ControlNet. The SNE Industrial Fieldbus Interface (SIFI) is an embedded device that acts as a communication module in a networked smart sensor. The purpose is to enable a smart sensor to communicate health and status information to other devices, such as PLCs, via an industrial Fieldbus networking protocol. The SNE (Smart Network Element) is attached to a commercial off-the-shelf Any bus-S interface module through the SIFI. Numerous Anybus-S modules are available, each one designed to interface with a specific Fieldbus. Development of the SIFI focused on communications using the ControlNet protocol, but any of the Anybus-S modules can be used. The SIFI communicates with the Any-bus module via a data buffer and mailbox system on the Anybus module, and supplies power to the module. The Anybus module transmits and receives data on the Fieldbus using the proper protocol. The SIFI is intended to be connected to other existing SNE modules in order to monitor the health and status of a transducer. The SIFI can also monitor aspects of its own health using an onboard watchdog timer and voltage monitors. The SIFI also has the hardware to drive a touchscreen LCD (liquid crystal display) unit for manual configuration and status monitoring.

Lucena, Angel↗

Formulation and Optimization of Robust Sensor Placement Problems for Drinking Water Contamination Warning Systems

We report that the sensor placement problem in contamination warning system design for municipal water distribution networks involves maximizing the protection level afforded by limited numbers of sensors, typically quantified as the expected impact of a contamination event; the issue of how to mitigate against high-consequence events is either handled implicitly or ignored entirely. Consequently, expected-case sensor placements run the risk of failing to protect against high-consequence 9/11-style attacks. In contrast, robust sensor placements address this concern by focusing strictly on high-consequence events and placing sensors to minimize the impact of these events. We introduce several robust variations of the sensor placement problem, distinguished by how they quantify the potential damage due to high-consequence events. We explore the nature of robust versus expected-case sensor placements on three real-world large-scale distribution networks. We find that robust sensor placements can yield large reductions in the number and magnitude of high-consequence events, with only modest increases in expected impact. Finally, the ability to trade-off between robust and expected-case impacts is a key unexplored dimension in contamination warning system design.

42 ENGINEERING↗

Sensor Network Demonstration for In Situ Decommissioning - 13332

Florida International University's (FIU's) Applied Research Center is currently supporting the Department of Energy's (DOE) Environmental Management Office of D and D and Facility Engineering program. FIU is supporting DOE's initiative to improve safety, reduce technical risks, and limit uncertainty within D and D operations by identifying technologies suitable to meet specific facility D and D requirements, assessing the readiness of those technologies for field deployment, and conducting feasibility studies and large scale demonstrations of promising technologies. During FY11, FIU collaborated with Savannah River National Laboratory in the development of an experimental test site for the demonstration of multiple sensor systems for potential use in the in situ decommissioning process. In situ decommissioning is a process in which the above ground portion of a facility is dismantled and removed, and the underground portion is filled with a cementious material such as grout. In such a scenario, the question remains on how to effectively monitor the structural health of the grout (cracking, flexing, and sinking), as well as track possible migration of contaminants within and out of the grouted monolith. The right types of sensors can aid personnel in better understanding the conditions within the entombed structure. Without sensors embedded in and around the monolith, it will be very difficult to estimate structural integrity and contaminant transport. Yet, to fully utilize the appropriate sensors and the provided data, their performance and reliability must be evaluated outside a laboratory setting. To this end, a large scale experimental setup and demonstration was conducted at FIU. In order to evaluate a large suite of sensor systems, FIU personnel designed and purchased a pre-cast concrete open-top cube, which served as a mock-up of an in situ DOE decommissioned facility. The inside of the cube measures 10 ft x 10 ft x 8 ft. In order to ensure that the individual sensors would be immobilized during the grout pouring activities, a set of nine sensor racks were designed. The 270 sensors provided by Idaho National Laboratory (INL), Mississippi State University (MSU), University of Houston (UH), and University of South Carolina (USC) were secured to these racks based on predetermined locations. Once sensor racks were installed inside the test cube, connected and debugged, approximately 32 cubic yards of special grout material was used to entomb the sensors. MSU provided and demonstrated four types of fiber loop ring-down (FLR) sensors for detection of water, temperature, cracks, and movement of fluids. INL provided and demonstrated time differenced 3D electrical resistivity tomography (ERT), advanced tensiometers for moisture content, and thermocouples for temperature measurements. University of Houston provided smart aggregate (SA) sensors, which detect crack severity and water presence. An additional UH sensor system demonstrated was a Fiber Bragg Grating (FBG) fiber optic system measuring strain, presence of water, and temperature. USC provided a system which measured acoustic emissions during cracking, as well as temperature and pH sensors. All systems were connected to a Sensor Remote Access System (SRAS) data networking and collection system designed, developed and provided by FIU. The purpose of SRAS was to collect and allow download of the raw sensor data from all the sensor system, as well as allow upload of the processed data and any analysis reports and graphs. All this information was made available to the research teams via the Deactivation and Decommissioning Knowledge Management and Information Tool (D and D KM-IT). As a current research effort, FIU is performing an energy analysis, and transferring several sensor systems to a Photovoltaic (PV) System to continuously monitor energy consumption parameters and overall power demands. Also, One final component of this research is focusing on developing an integrated data network to capture, log and analyze sensor system data in near real time from a single interface. FIU personnel and DOE Fellows monitored the progress and condition of the sensors for a period of six months. During this time, the sensors recorded data pertaining to strain, compression, temperature, crack detection, moisture presence, fluid mobility, shock resistance, monolith movement, and electrical resistivity. In addition, FIU regularly observed the curing process of the grout and documented the cube condition via the nine racks of sensors. The sensors held up throughout the curing process, withstood the natural elements for six months, and monitored the integrity of the grout. The large scale experiment and demonstration conducted at FIU was the first of its kind to demonstrate the feasibility of state of the art sensors for in situ decommissioning applications. These efforts successfully measured the durability, performance, and precision of the sensors in question as well as monitored and recorded the curing process of the selected grout material under natural environmental conditions. The current energy analysis work is resulting in data on the constraints placed by some of the sensor systems on a power network that requires high reliability and low losses. In addition, a sensor system demonstration has determined that it is feasible to develop an integrated data network where data can be accessed in near real-time from all systems, thereby allowing for larger-scale integrated system testing to be performed. Information collected during the execution of this research project will aid decision makers in the identification of sensors to be used in nuclear facilities selected for in situ decommissioning. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Limited Role of Absolute Humidity in Intraurban Heat Variability

Abstract Monitoring and understanding the variability of heat within cities is important for urban planning and public health, and the number of studies measuring intraurban temperature variability is growing. Recognizing that the physiological effects of heat depend on humidity as well as temperature, measurement campaigns have included measurements of relative humidity alongside temperature. However, the role the spatial structure in humidity, independent from temperature, plays in intraurban heat variability is unknown. Here we use summer temperature and humidity from networks of stationary sensors in multiple cities in the United States to show spatial variations in the absolute humidity within these cities are weak. This variability in absolute humidity plays an insignificant role in the spatial variability of the heat index and humidity index (humidex), and the spatial variability of the heat metrics is dominated by temperature variability. Thus, results from previous studies that considered only intraurban variability in temperature will carry over to intraurban heat variability. Also, this suggests increases in humidity from green infrastructure interventions designed to reduce temperature will be minimal. In addition, a network of sensors that only measures temperature is sufficient to quantify the spatial variability of heat across these cities when combined with humidity measured at a single location, allowing for lower-cost heat monitoring networks. Significance Statement Monitoring the variability of heat within cities is important for urban planning and public health. While the physiological effects of heat depend on temperature and humidity, it is shown that there are only weak spatial variations in the absolute humidity within nine U.S. cities, and the spatial variability of heat metrics is dominated by temperature variability. This suggests increases in humidity will be minimal resulting from green infrastructure interventions designed to reduce temperature. It also means a network of sensors that only measure temperature is sufficient to quantify the spatial variability of heat across these cities when combined with humidity measured at a single location.

Meteorology & Atmospheric Sciences↗

Integrated Spatial, Spectral, & Temporal Optical Reflectance System for Precision Occupancy & Location Sensing to Improve Building Energy Efficiency

Buildings consume approximately 35% of the electricity used in the U.S. and building owners can significantly reduce this energy use by providing services like heating, electrical power and lighting only when people are present. The ARPAe funded program titled “INTEGRATED SPATIAL, SPECTRAL, & TEMPORAL OPTICAL REFLECTANCE SYSTEM FOR PRECISION OCCUPANCY & LOCATION SENSING TO IMPROVE BUILDING ENERGY EFFICIENCY” demonstrates how a low cost sensor technology developed for measuring distances can be used to count and locate occupants with a high degree of precision with a very low error rates. This platform tells a building control system where occupants are located (but not who they are) so that energy consuming services can be provided only when the services are needed by building occupants. The original proof of concept involved using low cost, commercially available time-of-flight (TOF) sensors that measure distance, but the performance of these existing sensors was lacking, as they could not operate properly in the presence of sunlight, which blinded the simple TOF sensors and limited their utility in buildings. This project proposed a powerful new class of TOF sensors that used state-of-the-art integrated circuit (IC) fabrication processes that combined advanced photonics with conventional silicon chip circuitry for improved sensor performance. An equally important part of this project was to find ways to maximize occupant count and location accuracy while using the fewest number of sensors possible, in order to keep costs low. By using building blueprints to create digital twins of commercial building spaces, the team developed new algorithms to maximize occupant count and tracking accuracy by properly locating the minimum number of sensors at just the right spots in the building. This capability not only minimizes system costs but also simplified sensor installation and system commissioning. Our simulations of our sensor networks for a range of commercial floorplan designs demonstrated that our installed cost target of $0.08/sqft was attainable, though not fully demonstrated during the project. Finally, we noted that the TOF sensor concept could provide a valuable role in health and eldercare by tracking patients without the need for worn sensors and would be useful for fall detection and other patient safety metrics, including tracking healthcare/patient interactions. We feel that, when fully developed, this new class of sophisticated TOF sensors and support software will be a powerful new approach to improving building energy efficiency based on occupant centric control platforms and will also open new levels of patient safety in healthcare operations. To realize this potential, the team formed the Troy Sensor Company LLC to oversee licensing of the programs patents and continue to seek commercialization of this program’s activity sensing technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Acoustic Source Localization via Time Difference of Arrival Estimation for Distributed Sensor Networks Using Tera‐Scale Optical Core Devices

For real‐time acoustic source localization applications, one of the primary challenges is the considerable growth in computational complexity associated with the emergence of ever larger, active or passive, distributed sensor networks. These sensors rely heavily on battery‐operated system components to achieve highly functional automation in signal and information processing. In order to keep communication requirements minimal, it is desirable to perform as much processing on the receiver platforms as possible. However, the complexity of the calculations needed to achieve accurate source localization increases dramatically with the size of sensor arrays, resulting in substantial growth of computational requirements that cannot be readily met with standard hardware. One option to meet this challenge builds upon the emergence of digital optical‐core devices. The objective of this work was to explore the implementation of key building block algorithms used in underwater source localization on the optical‐core digital processing platform recently introduced by Lenslet Inc. This demonstration of considerably faster signal processing capability should be of substantial significance to the design and innovation of future generations of distributed sensor networks.

Imam, Neena↗

Robust Predictive Design of Field Measurements for Evapotranspiration Barriers Using Universal Multiple linear Regression

Surface barriers are normally installed to reduce downward water movement into contaminated zones. Specifically, evapotranspiration (ET) barriers are used to store water and release it, via ET, before it can percolate into an underlying waste zone. To assess the effectiveness of a surface barrier, we used an existing data set, model-simulated data, and a dimensionality reduction approach called universal multiple linear regression (uMLR) to optimize the required number of sensors in a 2-m thick surface barrier. To understand the usefulness of implementing predictive uMLR to accommodate multiple monitoring objectives, we compare several network designs, selected based on down-sampling of existing data, with a recommended sensor design based on model simulations performed without consideration of existing data. We further added consideration of “fuzzy” design, which allows more practical guidelines for field implementation of uMLR. We discovered that uMLR, combined with robust decision-making, provides a simple, flexible, and high-quality network design for monitoring the total water stored in a surface barrier across multiple uncertain conditions.

58 GEOSCIENCES↗

In Situ Decommissioning Sensor Network, Meso-Scale Test Bed - Phase 3 Fluid Injection Test Summary Report

The DOE Office of Environmental management (DOE EM) faces the challenge of decommissioning thousands of excess nuclear facilities, many of which are highly contaminated. A number of these excess facilities are massive and robust concrete structures that are suitable for isolating the contained contamination for hundreds of years, and a permanent decommissioning end state option for these facilities is in situ decommissioning (ISD). The ISD option is feasible for a limited, but meaningful number of DOE contaminated facilities for which there is substantial incremental environmental, safety, and cost benefits versus alternate actions to demolish and excavate the entire facility and transport the rubble to a radioactive waste landfill. A general description of an ISD project encompasses an entombed facility; in some cases limited to the blow-grade portion of a facility. However, monitoring of the ISD structures is needed to demonstrate that the building retains its structural integrity and the contaminants remain entombed within the grout stabilization matrix. The DOE EM Office of Deactivation and Decommissioning and Facility Engineering (EM-13) Program Goal is to develop a monitoring system to demonstrate long-term performance of closed nuclear facilities using the ISD approach. The Savannah River National Laboratory (SRNL) has designed and implemented the In Situ Decommissioning Sensor Network, Meso-Scale Test Bed (ISDSN-MSTB) to address the feasibility of deploying a long-term monitoring system into an ISD closed nuclear facility.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Resilient Monitoring Systems: Architecture, Design, and Application to Boiler/Turbine Plant

Resilient monitoring systems, considered in this paper, are sensor networks that degrade gracefully under malicious attacks on their sensors, causing them to project misleading information. The goal of this work is to design, analyze, and evaluate the performance of a resilient monitoring system intended to monitor plant conditions (normal or anomalous). The architecture developed consists of four layers: data quality assessment, process variable assessment, plant condition assessment, and sensor network adaptation. Each of these layers is analyzed by either analytical or numerical tools. The performance of the overall system is evaluated using a simplified boiler/turbine plant. The measure of resiliency is quantified using Kullback-Leibler divergence, and is shown to be sufficiently high in all scenarios considered.

97 MATHEMATICS AND COMPUTING↗

Real-Time Alpine Measurement System Using Wireless Sensor Networks

Monitoring the snow pack is crucial for many stakeholders, whether for hydro-power optimization, water management or flood control. Traditional forecasting relies on regression methods, which often results in snow melt runoff predictions of low accuracy in non-average years. Existing ground-based real-time measurement systems do not cover enough physiographic variability and are mostly installed at low elevations. We present the hardware and software design of a state-of-the-art distributedWireless Sensor Network (WSN)-based autonomous measurement system with real-time remote data transmission that gathers data of snow depth, air temperature, air relative humidity, soil moisture, soil temperature, and solar radiation in physiographically representative locations. Elevation, aspect, slope and vegetation are used to select network locations, and distribute sensors throughout a given network location, since they govern snow pack variability at various scales. Three WSNs were installed in the Sierra Nevada of Northern California throughout the North Fork of the Feather River, upstream of the Oroville dam and multiple powerhouses along the river. The WSNs gathered hydrologic variables and network health statistics throughout the 2017 water year, one of northern Sierra’s wettest years on record. These networks leverage an ultra-low-power wireless technology to interconnect their components and offer recovery features, resilience to data loss due to weather and wildlife disturbances and real-time topological visualizations of the network health. Data show considerable spatial variability of snow depth, even within a 1 km 2 network location. In conclusion, combined with existing systems, these WSNs can better detect precipitation timing and phase in, monitor sub-daily dynamics of infiltration and surface runoff during precipitation or snow melt, and inform hydro power managers about actual ablation and end-of-season date across the landscape.

47 OTHER INSTRUMENTATION↗