Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sensitivity Matrix”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Excitation spectral microscopy for highly multiplexed fluorescence imaging and quantitative biosensing

The multiplexing capability of fluorescence microscopy is severely limited by the broad fluorescence spectral width. Spectral imaging offers potential solutions, yet typical approaches to disperse the local emission spectra notably impede the attainable throughput. Here we show that using a single, fixed fluorescence emission detection band, through frame-synchronized fast scanning of the excitation wavelength from a white lamp via an acousto-optic tunable filter, up to six subcellular targets, labeled by common fluorophores of substantial spectral overlap, can be simultaneously imaged in live cells with low (~1%) crosstalks and high temporal resolutions (down to ~10 ms). The demonstrated capability to quantify the abundances of different fluorophores in the same sample through unmixing the excitation spectra next enables us to devise novel, quantitative imaging schemes for both bi-state and Förster resonance energy transfer fluorescent biosensors in live cells. We thus achieve high sensitivities and spatiotemporal resolutions in quantifying the mitochondrial matrix pH and intracellular macromolecular crowding, and further demonstrate, for the first time, the multiplexing of absolute pH imaging with three additional target organelles/proteins to elucidate the complex, Parkin-mediated mitophagy pathway. Together, excitation spectral microscopy provides exceptional opportunities for highly multiplexed fluorescence imaging. The prospect of acquiring fast spectral images without the need for fluorescence dispersion or care for the spectral response of the detector offers tremendous potential.

59 BASIC BIOLOGICAL SCIENCES↗

Correlations of conserved quantities at finite baryon density

Correlations involving the seven conserved quantities, namely energy, baryon number, electric charge, strangeness, and the three components of momentum, give rise to correlations in heavy-ion collisions. Through the utilization of a simple one-dimensional hydrodynamic model, we calculate the evolution of the entire 7×7 matrix of correlations as a function of relative spatial rapidity. This comprehensive analysis accounts for finite baryon density, which results in off-diagonal correlations between the charge-related quantities and the energy-momentum quantities. These correlations in coordinate space are subsequently transformed into correlations in momentum space using statistical weighting. As a result, the entire matrix of correlations is revealed to be highly sensitive to the equation of state, viscosity, and diffusivity.

Equations of state of nuclear matter↗

A Sensitive Electrochemical Cholinesterase-Inhibiting Biosensor for Organophosphorus Pesticides Based on Ti 3 C 2 TX MXene Quantum Dots

Organophosphorus pesticides (OPs) pose significant environmental and health risks due to their widespread use and toxicity, primarily by inhibiting acetylcholinesterase. Traditional detection methods are often slow and costly, highlighting the urgent need for advanced, sensitive, and accessible technologies. This study developed a highly sensitive electrochemical cholinesterase-inhibiting biosensor for OP pesticides, utilizing Ti 3 C 2 T x MXene Quantum Dots (MQDs), which was synthesized via a hydrothermal method. The biosensor’s performance was characterized using electrochemical impedance spectroscopy, differential pulse voltammetry (DPV), and cyclic voltammetry. DPV proved to be the optimal technique, exhibiting an ultralow detection limit of 1 × 10 −17 M and a wide linear range (10 −14 –10 −8 M) for chlorpyrifos (a model OP) with an estimated inhibition constant of 62 nM. The biosensor demonstrated high selectivity for OPs (chlorpyrifos, acephate, glyphosate) over a non-target pyrethroid (permethrin), confirmed by distinct electrochemical signatures and compared to in vitro cholinergic activity assays in bean beetle homogenates. The enhanced performance is attributed to the high surface-to-volume ratio, quantum confinement effects, and superior conductivity of the MQDs, as well as the robust enzyme immobilization facilitated by glutaraldehyde cross-linking and a chitosan matrix. This work presents a promising platform for rapid, sensitive, and selective detection of OP pesticides, with potential applications in environmental monitoring and public health protection.

Chemistry↗

Bismuth Subcarbonate Decorated Reduced Graphene Oxide Nanocomposite for the Sensitive Stripping Voltammetry Analysis of Pb(II) and Cd(II) in Water

In this paper, bismuth subcarbonate (BiO)2CO3-reduced graphene oxide nanocomposite incorporated in Nafion matrix ((BiO)2CO3-rGO-Nafion) was synthesized and further applied, for the first time, in the sensitive detection of Pb(II) and Cd(II) by square-wave anodic stripping voltammetry (SWASV). The as-synthesized nanocomposites were characterized by energy-dispersive spectroscopy (EDS), Raman spectroscopy, scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). (BiO)2CO3 composite plays a key role in the improvement of the detection sensitivity, which can form multicomponent alloy with cadmium and lead. Additionally, the unique structure of rGO can enlarge the surface area and provide abundant active sites. Moreover, Nafion incorporation in the nanocomposite can effectively increase the adhesion and mechanical strength of the film, and further improve the preconcetration ability due to the cation-exchange capacity of its abundant sulfonate groups. As expected, the (BiO)2CO3-rGO/Nafion nanocomposite-modified glassy carbon electrode ((BiO)2CO3-rGO-Nafion/GCE) achieved low detection limits of 0.24 μg/L for Pb(II) and 0.16 μg/L for Cd(II), in the linear range of 1.0–60 μg/L, and showed some excellent performance, such as high stability, good selectivity, and sensitivity. Finally, synthetic water samples were prepared and further used to verify the practicability of the (BiO)2CO3-rGO-Nafion/GCE with satisfactory results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of globally spin-aligned vector mesons to the measurements of the chiral magnetic effect in heavy-ion collisions

The chiral magnetic effect (CME) in high-energy heavy-ion collisions arises from the interplay between the chirality imbalance and the intense magnetic field and will cause a charge separation along the magnetic field direction. While the CME search is still ongoing in experiments, the non-CME contributions need to be excluded from the CME observables. In this work, we examine the influence of globally spin-aligned ρ mesons on the γ 112 correlator, the R Ψ 2 (ΔS) correlator, and the signed balance functions, via a toy model and a multiphase transport model (AMPT). We find that the CME observables are sensitive to the 00-component of the spin density matrix, ρ 00 : they receive positive (negative) contributions when ρ 00 is larger (smaller) than 1/3.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hybrid Symbolic-Numerical Modeling and Parametric Stability Analysis of DC–AC Power Systems

Hybrid DC-AC power systems integrating diverse inverter-based resources (IBRs) and multi-terminal high-voltage direct current (MTDC) networks represent a promising architecture for future power grids, while introducing challenges for modeling, stability analysis, and control design. This paper develops a hybrid symbolic-numerical modeling framework and tool to characterize the parametric small-signal stability of DC-AC coupled power systems. The proposed approach constructs parametric state-space models to enable efficient representation of system dynamics under varying control parameters and network configurations, with target parameters retained as symbolic variables and the remainder treated numerically. The stability analysis framework covers eigenvalue, sensitivity, and stability boundary and region characterization. Enhanced linear matrix inequality (LMI) techniques are proposed to directly certify small-signal stability over regions of parameter space while also reducing the conservativeness and computational burden. The resulting tools and frameworks enable rapid parametric model construction across diverse grid conditions, thereby facilitating stability-informed control and operation in complex DC–AC power systems.

DC–AC power systems↗

Real-Time, Adaptive Radiological Anomaly Detection and Isotope Identification Using Non-Negative Matrix Factorization

Spectroscopic anomaly detection and isotope identification algorithms are integral components in nuclear nonproliferation applications such as search operations. The task is especially challenging in the case of mobile detector systems because the observed gamma-ray background changes more than for a static detector system, and a pretrained background model can easily find itself out of domain. The result is that algorithms may exceed their intended false alarm rate or sacrifice detection sensitivity to maintain the desired false alarm rate. Non-negative matrix factorization (NMF) is a powerful tool for spectral anomaly detection and identification, but, like many similar algorithms that rely on data-driven background models, in its conventional implementation, it is unable to update in real time to account for environmental changes that affect the background spectroscopic signature. Here, we have developed a novel NMF-based algorithm that periodically updates its background model to accommodate changing environmental conditions. The adaptive NMF algorithm involves fewer assumptions about its environment, making it more generalizable than existing NMF-based methods while maintaining or exceeding detection performance on simulated and real-world datasets.

Anomaly detection↗

Reflective Fiber Temperature Probe Based on Localized Surface Plasmon Resonance towards Low-Cost and Wireless Interrogation

Reflection fiber temperature sensors functionalized with plasmonic nanocomposite material using intensity-based modulation are demonstrated for the first time. Characteristic temperature optical response of the reflective fiber sensor is experimentally tested using Au-incorporated nanocomposite thin films deposited on the fiber tip, and theoretically validated using a thin-film-optic-based optical waveguide model. By optimizing the Au concentration in a dielectric matrix, Au nanoparticles (NP) exhibit a localized surface plasmon resonance (LSPR) absorption band in a visible wavelength that shows a temperature sensitivity ~0.025%/°C as a result of electron–electron and electron–phonon scattering of Au NP and the surrounding matrix. Detailed optical material properties of the on-fiber sensor film are characterized using scanning electron microscopy (SEM) and focused-ion beam (FIB)-assisted transmission electron microscopy (TEM). Airy’s expression of transmission and reflection using complex optical constants of layered media is used to model the reflective optical waveguide. A low-cost wireless interrogator based on a photodiode transimpedance-amplifier (TIA) circuit with a low-pass filter is designed to integrate with the sensor. The converted analog voltage is wirelessly transmitted via 2.4 GHz Serial Peripheral Interface (SPI) protocols. Feasibility is demonstrated for portable, remotely interrogated next-generation fiber optic temperature sensors with future capability for monitoring additional parameters of interest.

47 OTHER INSTRUMENTATION↗

Comprehensive review of combustion ion chromatography for the analysis of total, adsorbable, and extractable organic fluorine

Poly‐ and perfluoroalkyl substances (PFAS) are a class of persistent organic pollutants whose high stability and appreciable water solubility have led to near‐global contamination. PFAS are bioaccumulative toxins that have been linked to a myriad of disorders and have been detected nearly universally in human blood. Liquid chromatography‐tandem mass spectrometry is the most frequent method used for quantitation, though this typically only measures a few dozen of the >14 000 known PFAS and has been shown to account for a small portion of the total organic fluorine present. Sum parameter methods such as total, extractable, and adsorbable organic fluorine have emerged as alternative measurements for PFAS determination. Combustion ion chromatography has become the preferred method for organofluorine measurement where the sorbent or extract containing PFAS is combusted and the emitted hydrofluoric acid (HF) is a measure of the cumulative organofluorine present. Herein we critically review the types of organofluorine measurement, their separation from the sample matrix, and key parameters of the analytical instrument that affect sensitivity, reproducibility, and recovery with regards to PFAS analysis.

Chemistry↗

Computational Aspects of Single-Molecule Kinetics for Coupled Catalytic Cycles: A Spectral Analysis

Catalysis from single active sites is analyzed using methods developed from single molecule kinetics. Using a stochastic Markov state description, the observable properties of general catalytic networks of reactions are expressed using an eigenvalue decomposition of the transition matrix for the Markov process. By the use of a sensitivity analysis, the necessary eigenvalues and eigenvectors are related to the energies of controlling barriers and wells located along the reaction routes. A generalization of the energetic span theory allows the eigenvalues to be computed from several activation energies corresponding to distinct barrier-well pairings. The formalism is demonstrated accurately for model problems for a physically realistic mechanism for an alkene hydrogenation reaction on a single atom catalyst.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Light field–controlled PHz currents in intrinsic metals

Oriented electric currents in metals are routinely driven by applying an external electric potential. Although the response of electrons to the external electric fields occurs within attoseconds, conventional electronics do not use this speed potential. Ultrashort laser pulses with controlled shapes of electric fields that switch direction at petahertz frequencies open perspectives for driving currents in metals. Light field–driven currents were demonstrated in various media including dielectrics, semiconductors, and topological insulators. Now, our research question is whether we can drive and control orders of magnitude more charge carriers in metals enabling ultrafast switching with practically low-energy, picojoule-level pulses. Here, we demonstrate the interaction of light with nanometer-thick metallic layers, which leads to a generation of light field–controlled electric currents. We show that the implantation of metallic layers into a dielectric matrix leads to up to 40 times increase of the sensitivity in contrast to a bare dielectric, decreasing the intensity threshold for lightwave electronics.

Fehér, Beatrix [HUN-REN Wigner Research Centre for↗

Unfolding quantum computer readout noise

Abstract In the current era of noisy intermediate-scale quantum computers, noisy qubits can result in biased results for early quantum algorithm applications. This is a significant challenge for interpreting results from quantum computer simulations for quantum chemistry, nuclear physics, high energy physics (HEP), and other emerging scientific applications. An important class of qubit errors are readout errors. The most basic method to correct readout errors is matrix inversion, using a response matrix built from simple operations to probe the rate of transitions from known initial quantum states to readout outcomes. One challenge with inverting matrices with large off-diagonal components is that the results are sensitive to statistical fluctuations. This challenge is familiar to HEP, where prior-independent regularized matrix inversion techniques (“unfolding”) have been developed for years to correct for acceptance and detector effects, when performing differential cross section measurements. We study one such method, known as iterative Bayesian unfolding, as a potential tool for correcting readout errors from universal gate-based quantum computers. This method is shown to avoid pathologies from commonly used matrix inversion and least squares methods.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pyomo.DOE: An open-source package for model-based design of experiments in Python

Predictive mathematical models are a cornerstone of science and engineering. Yet selecting, calibrating, and validating said science-based models often remains an art in practice. Model-based design of experiments (MBDoE) provides a systematic framework to maximize information gain from experiments while minimizing time and resource costs. But MBDoE remains limited to niche application areas, in part because practitioners must integrate expertise in statistics, computational optimization, and modeling. To help reduce this barrier, we introduce Pyomo.DOE, an open-source package for MBDoE. Pyomo.DOE uses a nonlinear sensitivity analysis code k_aug to quickly approximate the Fisher information matrix and leverages a new stochastic programming abstraction. We demonstrate Pyomo.DOE with the first application of MBDoE to fixed-bed breakthrough experiments, which highlights the power of Pyomo.DOE to quantify the value of experimental modifications a priori for large-scale partial differential-algebraic equation (PDAE) models. Here we also provide a mathematical primer on MBDoE targeted at general chemical engineers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of lowering potassium contamination in liquid scintillation cocktails for ultra-sensitive radiation detection

Intrinsic 40 K radioactive backgrounds from impurities of natural K in liquid scintillation cocktails have previously been demonstrated to limit their use in ultra-sensitive applications. Here, this work explores two methodologies in parallel for the reduction of 40 K backgrounds in the cocktails, and lays the groundwork for use in ultra-sensitive applications. In one method, alternative low-K liquid scintillation matrix constituents were identified and in the other, a simple purification method for single components and finished cocktails was developed. Both methods were verified via ICP-MS analysis. Liquid scintillation counting of selected purified cocktails demonstrated background reduction, improved stability, and enhanced performance. The best performing purified cocktail was also counted on a custom-built ultra-low background liquid scintillation counter, with results below the detector background.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Probing anisotropies of the Stochastic Gravitational Wave Background with LISA

Here, we investigate the sensitivity of the Laser Interferometer Space Antenna (LISA) to the anisotropies of the Stochastic Gravitational Wave Background (SGWB). We first discuss the main astrophysical and cosmological sources of SGWB which are characterized by anisotropies in the GW energy density, and we build a Signal-to-Noise estimator to quantify the sensitivity of LISA to different multipoles. We then perform a Fisher matrix analysis of the prospects of detectability of anisotropic features with LISA for individual multipoles, focusing on a SGWB with a power-law frequency profile. We compute the noise angular spectrum taking into account the specific scan strategy of the LISA detector. We analyze the case of the kinematic dipole and quadrupole generated by Doppler boosting an isotropic SGWB. We find that β Ω GW ~ 2 × 10 -11 is required to observe a dipolar signal with LISA. The detector response to the quadrupole has a factor ~ 10 3 β relative to that of the dipole. The characterization of the anisotropies, both from a theoretical perspective and from a map-making point of view, allows us to extract information that can be used to understand the origin of the SGWB, and to discriminate among distinct superimposed SGWB sources.

79 ASTRONOMY AND ASTROPHYSICS↗

The polarized-signal density matrix: A practical way to recover molecular frame information from isotropic samples

We present a novel approach to model ultrafast time-dependent nonlinear optical polarization sensitive signals emitted from randomly oriented molecules. By projecting the laboratory-frame analyzer polarization axis into the molecular-frame and linking that axis with the density matrix through a tensor product, we demonstrate an approach to find a specific molecular orientation that yields a good approximation to simulated four-wave mixing signals produced by the same model but with averaging over molecular orientation.

Thurston, Richard L↗

A novel optical sensor for Pb 2+ detection based on in-situ formation of Ruddlesden-Popper phase (C 4 H 9 NH 3 ) 2 PbBr 4 perovskite

On account of the concentration sensitive photoluminescence (PL) property of the lead-based Ruddlesden-Popper (RP) phase perovskite material, a novel sensing mechanism for highly selective Pb 2+ detection based on the in-situ formation of highly emissive luminescence structure matrix (C 4 H 9 NH 3 ) 2 PbBr 4 has been demonstrated. The sensor exhibits high sensitivity and selectivity for detecting Pb 2+ in complex metal cations mixture solution. This research reports a novel type of sensor mechanism based on the in-situ formation of luminescent lead-based RP phase perovskite. Here, it paves the way for developing highly selective optical sensors for detecting heavy metal cations via their corresponding luminescence structure matrix.

36 MATERIALS SCIENCE↗

Sensitivity Analysis of Transient Critical Heat Flux by RIA Under High-Pressure Flow Boiling Conditions in TRTL

A reactivity-initiated accident (RIA) is a design-basis accident under which critical heat flux (CHF) is likely to be exceeded. The operational margin for RIAs is currently determined using steady-state CHF lookup tables, which provide conservative estimates relative to transient CHF phenomena. The Transient Reactor Test Loop (TRTL) facility at Oregon State University is capable of performing out-of-pile rapid heating experiments representative of a RIA at conditions representative of a pressurized water reactor (PWR). Here, to further our understanding of and ability to predict transient CHF under PWR conditions, we performed a sensitivity analysis on a RELAP5-3D model of the TRTL facility coupled to the RAVEN code framework to define a proposed experimental test matrix to be performed at the TRTL facility. We then implemented a flow boiling CHF correlation into RELAP5-3D and performed a secondary sensitivity analysis inspecting the impact of the built-in RELAP5-3D CHF and heat transfer multipliers on both the prediction of CHF and key safety parameters, such as peak cladding temperature and heat flux. The results show that the multiplier with the highest influence toward the prediction of CHF occurrence and the safety parameters is the transient CHF multiplier. Operational performance envelopes have been developed for each of the test matrix cases and will be used for validation once the experiments are performed. The TRTL facility is currently performing shakedown testing to verify system performance prior to proceeding with the experimental campaign. Restart testing results include pump curve restart testing, pressure tests, and heater rod thermocouple transients.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗