Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sensitivity Matrix”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

High-Sensitivity X-ray Polarimetry with Amorphous Silicon Active-Matrix Pixel Proportional Counters

Photoelectric X-ray polarimeters based on pixel micropattern gas detectors (MPGDs) offer order-of-magnitude improvement in sensitivity over more traditional techniques based on X-ray scattering. This new technique places some of the most interesting astronomical observations within reach of even a small, dedicated mission. The most sensitive instrument would be a photoelectric polarimeter at the focus of 2 a very large mirror, such as the planned XEUS. Our efforts are focused on a smaller pathfinder mission, which would achieve its greatest sensitivity with large-area, low-background, collimated polarimeters. We have recently demonstrated a MPGD polarimeter using amorphous silicon thin-film transistor (TFT) readout suitable for the focal plane of an X-ray telescope. All the technologies used in the demonstration polarimeter are scalable to the areas required for a high-sensitivity collimated polarimeter. Leywords: X-ray polarimetry, particle tracking, proportional counter, GEM, pixel readout

Black, J. K.↗

Shape sensitivity analysis of flutter response of a laminated wing

A method is presented for calculating the shape sensitivity of a wing aeroelastic response with respect to changes in geometric shape. Yates' modified strip method is used in conjunction with Giles' equivalent plate analysis to predict the flutter speed, frequency, and reduced frequency of the wing. Three methods are used to calculate the sensitivity of the eigenvalue. The first method is purely a finite difference calculation of the eigenvalue derivative directly from the solution of the flutter problem corresponding to the two different values of the shape parameters. The second method uses an analytic expression for the eigenvalue sensitivities of a general complex matrix, where the derivatives of the aerodynamic, mass, and stiffness matrices are computed using a finite difference approximation. The third method also uses an analytic expression for the eigenvalue sensitivities, but the aerodynamic matrix is computed analytically. All three methods are found to be in good agreement with each other. The sensitivities of the eigenvalues were used to predict the flutter speed, frequency, and reduced frequency. These approximations were found to be in good agreement with those obtained using a complete reanalysis.

Bergen, Fred D.↗

PACE OCI Polarization Sensitivity Based on Pre-launch Testing

The Ocean Color Instrument (OCI) is a sensor on the upcoming Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission, scheduled for launch in early 2024. OCI is a grating spectrometer with hyperspectral coverage from the ultraviolet (about 310 nm) to near-infrared (about 900 nm), with additional filtered channels in the short-wave infrared (940 nm – 2260 nm). This instrument will provide ocean color science data to continue the data sets collected by heritage sensors MODIS, SeaWiFs, and VIIRS, but with increased spectral coverage and improved accuracy. In order to achieve the high levels of accuracy demanded by the science community, a rigorous ground test program was conducted to calibrate the instrument and ensure that the calibration can be transferred to on-orbit operations. Some calibration parameters can only be measured during pre-launch testing; one such parameter is the polarization sensitivity. Polarization testing measured the Mueller matrix components needed to determine the polarization sensitivity for all spectral bands for a series of telescope scan angles covering the expected on-orbit scan range. Results indicate that the sensitivity is below 0.6 % except at the shortest wavelengths (less than 340 nm) and was characterized to better than 0.1 % above 340 nm. This indicates that any polarized scenes measured on orbit can be corrected for with a high degree of confidence.

PACE↗

PACE OCI Polarization Sensitivity Based on Pre-launch Testing

The Ocean Color Instrument (OCI) is a sensor on the upcoming Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission, scheduled for launch in early 2024. OCI is a grating spectrometer with hyperspectral coverage from the ultraviolet (about 310 nm) to near-infrared (about 900 nm), with additional filtered channels in the short-wave infrared (940 nm – 2260 nm). This instrument will provide ocean color science data to continue the data sets collected by heritage sensors MODIS, SeaWiFs, and VIIRS, but with increased spectral coverage and improved accuracy. In order to achieve the high levels of accuracy demanded by the science community, a rigorous ground test program was conducted to calibrate the instrument and ensure that the calibration can be transferred to on-orbit operations. Some calibration parameters can only be measured during pre-launch testing; one such parameter is the polarization sensitivity. Polarization testing measured the Mueller matrix components needed to determine the polarization sensitivity for all spectral bands for a series of telescope scan angles covering the expected on-orbit scan range. Results indicate that the sensitivity is below 0.6 % except at the shortest wavelengths (less than 340 nm) and was characterized to better than 0.1 % above 340 nm. This indicates that any polarized scenes measured on orbit can be corrected for with a high degree of confidence.

PACE↗

Design of robust state feedback controllers via eigenvalue/eigenvector assignment

A new method of selecting a multivariable state feedback controller is presented. The resulting controller simultaneously realizes arbitrary closed-loop eigenvalues, approximates specified modal behavior and achieves low eigensystem sensitivity with respect to plant parameter variations. The method characterizes a vector space slightly larger than the null space of the closed-loop system matrix and projects a desired modal matrix onto this space. Sensitivity of eigenvalues and eigenvectors is then minimized local to the desired modal matrix using a gradient search technique. A tutorial example to illustrate the design procedure is given.

Mielke, R. R.↗

Shape sensitivity analysis of flutter response of a laminated wing

A method is presented for calculating the shape sensitivity of a wing aeroelastic response with respect to changes in geometric shape. Yates' modified strip method is used in conjunction with Giles' equivalent plate analysis to predict the flutter speed, frequency, and reduced frequency of the wing. Three methods are used to calculate the sensitivity of the eigenvalue. The first method is purely a finite difference calculation of the eigenvalue derivative directly from the solution of the flutter problem corresponding to the two different values of the shape parameters. The second method uses an analytic expression for the eigenvalue sensitivities of a general complex matrix, where the derivatives of the aerodynamic, mass, and stiffness matrices are computed using a finite difference approximation. The third method also uses an analytic expression for the eigenvalue sensitivities, but the aerodynamic matrix is computed analytically. All three methods are found to be in good agreement with each other.

Kapania, Rakesh K.↗

Multiobjective insensitive design of airplane control systems with uncertain parameters

A multiobjective computer-aided design algorithm has been developed which minimizes the sensitivity of the design objectives to uncertainties in system parameters. The more important uncertain parameters are described by a gaussian random vector with known covariance matrix, and a vector sensitivity objective function is defined as the probabilities that the design objectives will violate specified requirements constraints. Control system parameters are found which minimize the sensitivity vector in a Pareto-optimal sense, using constrained minimization algorithms. Example results are shown for lateral stability augmentation system (SAS) design for three Shuttle flight conditions.

Schy, A. A.↗

Error analysis applied to several inversion techniques used for the retrieval of middle atmospheric constituents from limb-scanning MM-wave spectroscopic measurements

The formal retrieval error analysis of Rodgers (1990) allows the quantitative determination of such retrieval properties as measurement error sensitivity, resolution, and inversion bias. This technique was applied to five numerical inversion techniques and two nonlinear iterative techniques used for the retrieval of middle atmospheric constituent concentrations from limb-scanning millimeter-wave spectroscopic measurements. It is found that the iterative methods have better vertical resolution, but are slightly more sensitive to measurement error than constrained matrix methods. The iterative methods converge to the exact solution, whereas two of the matrix methods under consideration have an explicit constraint, the sensitivity of the solution to the a priori profile. Tradeoffs of these retrieval characteristics are presented.

Puliafito, E.↗

Preliminary investigation of acousto-ultrasonic evaluation of metal-matrix composite specimens

Acoustoultrasonic (AU) measurements were performed on a series of (0)8, (90)8, (+/-30)2s, (+/-60)2s, (0/90)2s, and (90/0)2s tensile specimens composed of eight laminated layers of continuous, SiC-fiber-reinforced Ti-15-3 matrix. The frequency spectrum was dominated by frequencies of longitudinal wave resonance through the thickness of the specimen at the sending transducer; signal propagation from the sender to the receiver was by shear waves. The magnitude of the frequency spectrum of the AU signal was used for calculating a stress-wave factor (SWF) based upon integrating the spectral distribution function. The SWF was sensitive to fiber-matrix debonding caused by mechanical strain and also to unconstrained thermal cycling. Damage in this metal-matrix composite structure due to tensile loading or thermal cycling was detected by this change in the magnitude of the frequency spectrum.

Kautz, Harold E.↗

Nondestructive evaluation of a ceramic matrix composite material

Monolithic ceramic materials have proven their usefulness in many applications, yet, their potential for critical structural applications is limited because of their sensitivity to small imperfections. To overcome this extreme sensitivity to small imperfections, ceramic matrix composite materials have been developed that have the ability to withstand some distributed damage. A borosilicate glass reinforced with several layers of silicon-carbide fiber mat has been studied. Four-point flexure and tension tests were performed not only to determine some of the material properties, but also to initiate a controlled amount of damage within each specimen. Acousto-ultrasonic (AU) measurements were performed periodically during mechanical testing. This paper will compare the AU results to the mechanical test results and data from other nondestructive methods including acoustic emission monitoring and X-ray radiography. It was found that the AU measurements were sensitive to the damage that had developed within the material.

Grosskopf, Paul P.↗

Derivatives of eigenvalues and eigenvectors of a general complex matrix

A survey of methods for sensitivity analysis of the algebraic eigenvalue problem for non-Hermitian matrices is presented. In addition, a modification of one method based on a better normalizing condition is proposed. Methods are classified as Direct or Adjoint and are evaluated for efficiency. Operation counts are presented in terms of matrix size, number of design variables and number of eigenvalues and eigenvectors of interest. The effect of the sparsity of the matrix and its derivatives is also considered, and typical solution times are given. General guidelines are established for the selection of the most efficient method.

Murthy, Durbha V.↗

Adaptive Inverse Control for Rotorcraft Vibration Reduction

This thesis extends the Least Mean Square (LMS) algorithm to solve the mult!ple-input, multiple-output problem of alleviating N/Rev (revolutions per minute by number of blades) helicopter fuselage vibration by means of adaptive inverse control. A frequency domain locally linear model is used to represent the transfer matrix relating the higher harmonic pitch control inputs to the harmonic vibration outputs to be controlled. By using the inverse matrix as the controller gain matrix, an adaptive inverse regulator is formed to alleviate the N/Rev vibration. The stability and rate of convergence properties of the extended LMS algorithm are discussed. It is shown that the stability ranges for the elements of the stability gain matrix are directly related to the eigenvalues of the vibration signal information matrix for the learning phase, but not for the control phase. The overall conclusion is that the LMS adaptive inverse control method can form a robust vibration control system, but will require some tuning of the input sensor gains, the stability gain matrix, and the amount of control relaxation to be used. The learning curve of the controller during the learning phase is shown to be quantitatively close to that predicted by averaging the learning curves of the normal modes. For higher order transfer matrices, a rough estimate of the inverse is needed to start the algorithm efficiently. The simulation results indicate that the factor which most influences LMS adaptive inverse control is the product of the control relaxation and the the stability gain matrix. A small stability gain matrix makes the controller less sensitive to relaxation selection, and permits faster and more stable vibration reduction, than by choosing the stability gain matrix large and the control relaxation term small. It is shown that the best selections of the stability gain matrix elements and the amount of control relaxation is basically a compromise between slow, stable convergence and fast convergence with increased possibility of unstable identification. In the simulation studies, the LMS adaptive inverse control algorithm is shown to be capable of adapting the inverse (controller) matrix to track changes in the flight conditions. The algorithm converges quickly for moderate disturbances, while taking longer for larger disturbances. Perfect knowledge of the inverse matrix is not required for good control of the N/Rev vibration. However it is shown that measurement noise will prevent the LMS adaptive inverse control technique from controlling the vibration, unless the signal averaging method presented is incorporated into the algorithm.

Jacklin, Stephen A.↗

Multiple boundary condition testing error analysis

Techniques for interpreting data from multiple-boundary-condition (MBC) ground tests of large space structures are developed analytically and demonstrated. The use of MBC testing to validate structures too large to stand alone on the ground is explained; the generalized least-squares mass and stiffness curve-fitting methods typically applied to MBC test data are reviewed; and a detailed error analysis is performed. Consideration is given to sensitivity coefficients, covariance-matrix theory, the correspondence between test and analysis modes, constraints and step sizes, convergence criteria, and factor-analysis theory. Numerical results for a simple beam problem are presented in tables and briefly characterized. The improved error-updating capabilities of MBC testing are confirmed, and it is concluded that reasonably accurate results can be obtained using a diagonal covariance matrix.

Glaser, R. J.↗

Polarization analysis of a balloon-borne solar magnetograph

The 10(exp -5) polarization specification for the Balloon-borne Vector Magnetograph (BVM) can be met. The 10(exp -5) specification is shown to be a limitation on the diattenuation and retardance along the chief ray path through the optical system, such that the magnitude of the polarization aberration piston term is constrained to be less than .5(10)(exp -5). Coating specification sheets are provided which will ensure that the polarization sensitivity of the BVM will be less than 10(exp -5). An optical design is provided for a vector magnetograph. Finally, to provide a concrete mathematical meaning for polarization sensitivity, the polarization aberration matrix is averaged of the exit pupil. This shows that the coupling between circular and linear states depends only on the magnitude of the polarization aberration piston term.

Reiley, Daniel J.↗

ISS-Crystal Growth of Photorefractive Materials (BSO): Critical Design Issues for Optimized Data Extraction from Space Experiments

Realization of the full potential of photorefractive materials in device technology is seriously impeded by our inability to achieve controlled formation of critical defects during single crystal growth and by difficulties in meeting the required degree of compositional uniformity on a micro-scale over macroscopic dimensions. The exact nature and origin of the critical defects which control photorefractivity could not as yet be identified because of gravitational interference. There exists, however, strong evidence that the density of defect formation and their spatial distribution are adversely affected by gravitational interference which precludes the establishment of quantifiable and controllable heat and mass transfer conditions during crystal growth. The current, NASA sponsored research at MIT is directed at establishing a basis for the development of a comprehensive approach to the optimization of property control during melt growth of photorefractive materials, making use of the m-g environment, provided in the International Space Station. The objectives to be pursued in m-g research on photorefractive BSO (Bi12SiO20) are: (a) identification of the x-level(s) responsible for photorefractivity in undoped BSO; (b) development of approaches leading to the control of x-level formation at uniform spatial distribution; (c) development of doping and processing procedures for optimization of the critical, application specific parameters, spectral response, sensitivity, response time and matrix stability. The presentation will focus on: the rationale for the justification of the space experiment, ground-based development efforts, design considerations for the space experiments, strategic plan of the space experiments, and approaches to the quantitative analysis of the space experiments.

Hyers, Robert W.↗

Mechanical Behavior of Notched SiC/SiC Composites

Gas turbine components such as combustor liners or turbine vanes are subject to regions of high stress-concentration, e.g., attachment to the frame or at cooling holes. Ceramic matrix composites (CMCs) are potential materials for high temperature applications in gas turbines. They offer some capability to relieve stress at regions of high stress-concentration via matrix damage accumulation. In this study notch sensitivity was examined for woven SiC fiber reinforced, melt-infiltrated SiC matrix composites with a BN interphase, utilizing either Hi-Nicalo(TM) fibers or the stiffer Sylramic fibers. The double-edge notched tensile test approach was used for a wide range of notch sizes and specimen widths. Both composite systems exhibited mild notch sensitivity similar to other CMC systems. Acoustic emission, detected during the tensile tests, indicated that matrix cracking occurred around notches at net-section stresses below the stress where matrix cracking first occurs in unnotched specimens. However, thermoelastic stress analysis did not show any measurable stress relief around notches after the specimens were preloaded.

Morscher, Gregory N.↗

Polarization sensitivity analysis of an earth remote sensing instrument - The MODIS-N phase B study

Polarization analysis software that employs Jones matrix formalism to calculate the polarization sensitivity of an instrument design was developed at Hughes Danbury Optical Systems. The code is capable of analyzing the full ray bundle at its angles of incidence for each optical surface. Input is based on the system ray trace and the thin film coating design at each surface. The MODIS-N (Moderate Resolution Imaging Spectrometer) system is used to demonstrate that it is possible to meet stringent requirements on polarization insensitivity associated with planned remote sensing instruments. Analysis indicates that a polarization sensitivity less than or equal to 2 percent was achieved in all desired spectral bands at all pointing angles, per specification. Polarization sensitivities were as high as 10 percent in similar remote sensing instruments.

Waluschka, E.↗