Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Scintillator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Crystal structure, electronic structure, optical and scintillation properties of self-activated Cs 4 YbI 6 [Crystal structure, optical and scintillation properties of self-activated Cs 4 YbI 6 ]

A self-activated Cs 4 YbI 6 single crystal was grown by the vertical Bridgman method. Crystal structure refinements verified the phase purity and the trigonal crystal system with a space group of $\bar{R}$ 3 c . By using differential scanning calorimetry, the melting and crystallization points were determined to be 550 and 510 °C, respectively. Luminescence and scintillation properties were systematically studied. Upon ultraviolet light (360 nm) excitation, the Cs 4 YbI 6 crystal exhibits bluish-green emission centered at 450 and 480 nm due to spin-allowed and spin-forbidden transitions of Yb 2+ activators. The lifetimes of the corresponding emission bands at room temperature are tens and hundreds of nanoseconds, respectively. X-ray excited radioluminescence spectrum is dominated by the spin-forbidden transition of Yb 2+ at 480 nm. The absolute light yield is 2700 ± 200 photons/MeV with a principal scintillation decay time of 33 ns. In conclusion, the physical explanation for the low light yield observed is proposed from experimental and theoretical insights.

36 MATERIALS SCIENCE↗

Comparative Neutron Detection Efficiency in He-3 Proportional Counters and Liquid Scintillators

We present new results on the neutron detection efficiency of detection systems based on He-3 proportional counters compared to organic liquid scintillators. The experiments were conducted using a well-characterized Cf-252 neutron source, measured bare, and shielded with slabs of polyethylene. The results show that the intrinsic neutron detection efficiency for the bare source is approximately 25% for the He-3 system, and 67% for the liquid scintillator system. When polyethylene sheets were used to shield the source in 2.54 cm increments, the neutron detection efficiency of both systems decreased exponentially to approximately 10% for the case of 25.4 cm. Experimental results were simulated using MCNPX-PoliMi and good agreement was found between measurement and simulation results for all the cases considered here.

Organic scintillator, He-3, neutron detection, det↗

Measurement of transmission efficiency for 400 MeV proton beam through collimator at Fermilab MuCool Test Area using Chromox-6 scintillation screen

The MuCool Test Area (MTA) at Fermilab is a facility to develop the technology required for ionization cooling for a future Muon Collider and/or Neutrino Factory. As part of this research program, feasibility studies of various types of RF cavities in a high magnetic field environment are in progress. As a unique approach, we have tested a RF cavity filled with a high pressure hydrogen gas with a 400 MeV proton beam in an external magnetic field (B = 3 T). Quantitative information about the number of protons passing through this cavity is an essential requirement of the beam test. The MTA is a flammable gas (hydrogen) hazard zone. Due to safety reasons, no active (energized) beam diagnostic instrument can be used. Moreover, when the magnetic field is on, current transformers (toroids) used for beam intensity measurements do not work due to the saturation of the ferrite material of the transformer. Based on these requirements, we have developed a passive beam diagnostic instrumentation using a combination of a Chromox-6 scintillation screen and CCD camera. This paper describes details of the beam profile and position obtained from the CCD image with B = 0 T and B = 3 T, and for high and low intensity proton beams. A comparison is made with beam size obtained from multi-wires detector. Beam transmission efficiency through a collimator with a 4 mm diameter hole is measured by the toroids and CCD image of the scintillation screen. Results show that the transmission efficiency estimated from the CCD image is consistent with the toroid measurement, which enables us to monitor the beam transmission efficiency even in a high magnetic field environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Auger recombination in sodium-iodide scintillators from first principles

Scintillator radiation detectors suffer from low energy resolution that has been attributed to non-linear light yield response to the energy of the incident gamma rays. Auger recombination is a key non-radiative recombination channel that scales with the third power of the excitation density and may play a role in the non-proportionality problem of scintillators. In this work, we study direct and phonon-assisted Auger recombination in NaI using first-principles calculations. Our results show that phonon-assisted Auger recombination, mediated primarily by short-range phonon scattering, dominates at room temperature. We discuss our findings in light of the much larger values obtained by numerical fits to z-scan experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Average neutron time-of-flight instrument response function inferred from single D-T neutron events within a plastic scintillator

The apparent ion temperature and neutron-reaction history are important characteristics of a fusion plasma. Extracting these quantities from a measured neutron-time-of-flight signal requires accurate knowledge of the instrument response function (IRF). This paper describes a novel method for obtaining the IRF directly for single DT neutron interactions by utilizing n-alpha coincidence. The t(d,α)n nuclear reaction was produced at Sandia National Laboratories’ Ion Beam Laboratory using a 300 keV Cockcroft-Walton generator to accelerate a 2.5 μA beam of 175 keV D + ions into a stationary ErT 2 target. The average neutron IRF was calculated by taking a time-corrected average of individual neutron events within an EJ-228 plastic scintillator. The scintillator was coupled to two independent photo-multiplier tubes operated in the current mode: a Hamamatsu 5946 mod-5 and a Photek PMT240. Finally, the experimental setup and results will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DUAL-PARTICLE DOSEMETER BASED ON ORGANIC SCINTILLATOR

Abstract Traditionally available handheld dosemeters are generally sensitive to only one type of radiation: neutrons or photons. Some dosemeters also rely on very specific attenuation correlations between response and dose, are not scalable in size and multiple dosemeters are required to characterise mixed-particle fields. The research presented here serves as a proof-of-concept for a method to simultaneously measure dose rates from neutrons and photons using a particle discriminating organic scintillation detector without the need for spectral deconvolution. The method was compared with traditional instruments and to simulation. Isotopic photon dose rates measured with this method were within 4% of simulated truth, whereas fission spectrum neutron dose rates were measured within 21%. Measurements of dose rates from both particles agree with simulated truth better than traditional instruments. This new method allows for measurement of dose equivalent from both neutrons and photons with a single instrument and no reliance on spectral deconvolution.

Miller, C. A.↗

Relationship of Li{sub 2}WO{sub 4} to the scheelite tungstate scintillators: Electronic structure and atomic positions from density-functional calculations

Density-functional calculations of the electronic structure and atomic positions are reported for Li{sub 2}WO{sub 4}. This compound is found to be very different from the tungstate scintillators such as PbWO{sub 4} in that both the valence and conduction bands are much less dispersive. This leads to a substantially larger band gap. The difference is understood in terms of the crystal structure, in particular, the longer O-O distances connecting the WO{sub 4} tetrahedra.

36 MATERIALS SCIENCE↗

Cherenkov and scintillation light separation in organic liquid scintillators

The CHErenkov/Scintillation Separation experiment (CHESS) has been used to demonstrate the separation of Cherenkov and scintillation light in both linear alkylbenzene (LAB) and LAB with 2 g/L of PPO as a fluor (LAB/PPO). This is the first successful demonstration of Cherenkov light detection from the more challenging LAB/PPO cocktail and improves on previous results for LAB. A time resolution of 338 ± 12 ps FWHM results in an efficiency for identifying Cherenkov photons in LAB/PPO of 70 ± 3 % and 63 ± 8 % for time- and charge-based separation, respectively, with scintillation contamination of 36 ± 5 % and 38 ± 4 %. LAB/PPO data is consistent with a rise time of τ r = 0.72 ± 0.33 ns.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cosmic ray scintillations. II - General theory of interplanetary scintillations

The motion of charged particles in a stochastic magnetic field with nonzero mean is considered via a generalized quasi-linear expansion of Liouville's equation. The general result is an equation relating cosmic ray scintillations to magnetic fluctuations and to cosmic ray gradients. The resonant interaction between particles and the random magnetic field is considered in detail, and the effect of nonlinear terms in the equations is considered. The nonlinear terms are important in damping out initial conditions and in determining conditions near cyclotron resonances. The application of the theory to the propagation of cosmic rays during quiet times in interplanetary space is considered. It is concluded that cosmic ray scintillations in interplanetary space may provide useful information about interplanetary particles and fields and also about nonlinear plasma interactions.

Owens, A. J.↗

Crystal growth and scintillation properties of strontium iodide scintillators

Single crystals of SrI{sub 2}:Eu and SrI{sub 2}:Ce/Na were grown from anhydrous iodides by the vertical Bridgman technique in evacuated silica ampoules. Growth rates were of the order of 5-30 mm/day. Radioluminescence spectra of SrI{sub 2}:Eu and SrI{sub 2}:Ce/Na exhibit a broad band due to Eu{sup 2+} and Ce{sup 3+} emission, respectively. The maximum in the luminescence spectrum of SrI{sub 2}:Eu is found at 435 nm. The spectrum of SrI{sub 2}:Ce/Na exhibits a doublet peaking at 404 and 435 nm attributed to Ce{sup 3+} emission, while additional impurity - or defected - related emission is present at approximately 525 nm. The strontium iodide scintillators show very high light yields of up to 120,000 photons/MeV, have energy resolutions down to 3% at 662 keV (Full Width Half Maximum) and exhibit excellent light yield proportionality with a standard deviation of less than 5% between 6 and 460 keV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structure and scintillation of Eu2+-activated calcium bromide iodide

© 2015, Elsevier. All rights reserved. We report the structure and scintillation properties of Eu2+-activated calcium bromide iodide. CaBr0.7I1.3was the only composition that could be synthesized in the CaBr2-CaI2 system. The compound has an effective atomic number of 47 and crystallizes in a trigonal crystal system with the R-3 space group and a density of 3.93 g/cc. The structure is layered and contains Ca in an octahedral environment with the Br/I anions jointly occupying a single site. Eu2+-activated samples show an intense narrow emission, characteristic of the 5d-4f transition of Eu2+, when excited with UV or X-rays. The sample with 0.5% Eu shows a light output of 63,000 ph/MeV at 662 keV with 96% of the light emitted with a monoexponential decay time of 1332 ns. An energy resolution of 10.4% full width at half maximum (FWHM) has been achieved for 662 keV gamma rays at room temperature.

Gundiah, Gautam↗