Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Scanning Electron Microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 73 records · Page 4

Understanding Biases in Sample Preparation Techniques for Coupled Scanning Electron Microscopy and MAMA PuO 2 Morphological Analysis

In this project, the scanning electron microscopy (SEM) sampling method used during the statistical design study (SDS) was investigated to determine if any sampling biases were present in the analyzed data. Using standard particle size distribution powders from the National Institute of Standards and Technology (NIST 1984 standard reference material) with the origin wet dispersion method, it was determined that a bias to smaller particles was present. This was supported by theoretical calculations using Stokes’ law to determine the settling rate of spherical particles of roughly the same size and mass as those found in the SDS. Based on the theoretical calculations, it was determined that the settling rate for each of the 76 powder sets in the SDS could be unique based on specific particle shape and mass distributions, making a universal correction factor/formula not applicable. Therefore, priority shifted to developing an improved wet dispersion method that significantly reduced the particle settling rate for all particle size and shapes. This was achieved by replacing the original solvent (isopropyl alcohol) with a heavy liquid (lithium heteropolytungstates), which dramatically slowed the settling rate and allowed for the capture of a suitable homogeneous aliquot. SEM imaging and Morphological Analysis for Material Attribution (MAMA) software analysis were conducted on the NIST standard, and the SEM/MAMA data were compared to data captured by a dynamic image analysis particle size analyzer. The resulting data confirmed that the new wet dispersion method does indeed deliver an improved representative aliquot to the SEM stub. For instance, in the NIST certificate, the average particle size is ~17.1 µm ± 2.2 µm with a normal distribution. The initial wet dispersion method resulted in a drastically reduced average particle size of 6.1 µm in addition to a non-representative heavy bi-modal distribution whereas the improved LST wet dispersion method resulting in an average particle size that was much closer to the NIST certificate (12.7 µm) with a similar normal distribution. Although the improved method was still short of the NIST certificate average, atomic force microscopy analysis determined that the resulting ~20-25% reduction in size was due to particles sinking into the carbon sticky tape used for SEM imaging. It is believed that that this bias can be calibrated in a much more predicable manner than the original settling rate bias. In addition, the matching normal distribution curves between the NIST certificate and the heavy liquid method indicate a much-improved representative aliquot has been sampled and imaged. A surrogate CeO 2 powder was used to reflect PuO 2 more accurately and to aid in implementing radiological controls and shielding. The resulting data sets from the SEM/MAMA method and the particle size analyzer give almost identical average particle sizes and particle distribution statistics. Future work will re-analyze several select runs from the SDS to determine if morphological signatures can be found with the improved sampling method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Phase Development in a U-7 wt.% Mo vs. Al-7 wt.% Ge Diffusion Couple

Fuel development for the Reduced Enrichment for Research and Test Reactors (RERTR) program has demonstrated that U-Mo alloys in contact with Al develop interaction regions with phases that have poor irradiation behavior. The addition of Si to the Al has been considered with positive results. Compositional modification to replace Si with Ge is now under evaluation to attempt to further improve irradiation behavior. In this study, the microstructural and phase development of a diffusion couple of U-7 wt.% Mo in contact with Al-7 wt.% Ge was examined by transmission electron microscopy, scanning electron microscopy and energy dispersive spectroscopy. The interdiffusion zone developed a microstructure that included the cubic-UGe3 phase and amorphous phases. The UGe3 phase was observed with and without Mo and Al solid solutioning developing a (U,Mo)(Al,Ge)3 phase.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Microstructural evolution of NF709 (20Cr–25Ni–1.5MoNbTiN) under neutron irradiation

In this study, because of its superior creep and corrosion resistance as compared with general austenitic stainless steels, NF709 has emerged as a candidate structural material for advanced nuclear reactors. To obtain fundamental information about the radiation resistance of this material, this study examined the microstructural evolution of NF709 subjected to neutron irradiation to 3 displacements per atom at 500 °C. Transmission electron microscopy, scanning electron microscopy, and high-energy x-ray diffraction were employed to characterize radiation-induced segregation, Frank loops, voids, as well as the formation and reduction of precipitates. Radiation hardening of ~76% was estimated by nanoindentation, approximately consistent with the calculation according to the dispersed barrier-hardening model, suggesting Frank loops as the primary hardening source.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cement paste surface roughness analysis using coherence scanning interferometry and confocal microscopy

Scanning electron microscopy and scanning probe microscopy have been used for several decades to better understand the microstructure of cementitious materials. Very limited work has been performed to date to study the roughness of cementitious materials by optical microscopy such as coherence scanning interferometry (CSI) and chromatic confocal sensing (CCS). The objective of this paper is to better understand how CSI can be used as a tool to analyze surface roughness and topography of cement pastes. Observations from a series of images acquired using this technique on both polished and unpolished samples are described. The results from CSI are compared with those from a STIL confocal microscopy technique (SCM). Comparison between both optical techniques demonstrates the ability of CSI to measure both polished and unpolished cement pastes. - Highlights: • Coherence scanning interferometry (CSI) was used to analyze cement paste surfaces. • The results from the CSI were compared with those from a confocal microscopy. • 3D roughness parameters were obtained using the window resizing method. • Polished and unpolished cement pastes were studied.

36 MATERIALS SCIENCE↗

Catalytic hydrogen sensing using microheated platinum nanoparticle-loaded graphene aerogel

We present that low power catalytic hydrogen sensors are fabricated by functionalizing low power polysilicon microheaters with platinum nanoparticle catalyst loaded in a high surface area graphene aerogel support. Fabrication and characterization of the polysilicon microheaters are described. The platinum nanoparticle-loaded graphene aerogel is characterized by transmission electron microscopy, scanning electron microscopy, and energy dispersive X-ray spectroscopy. Finally, the catalytic hydrogen sensors consume as little as 2.2 mW of power, have sensitivity of 1.6%/10,000 ppm hydrogen, a t90 response and recovery time of 0.97 s and 0.72 s, respectively, a lower detection limit of approximately 65 ppm, and negligible cross sensitivity to methane, n-pentane, and diethylether.

08 HYDROGEN↗

Characterization and corrosion behavior test of glass ceramic waste form

The research conducted in this work package is to collect data in support of future development of glass ceramic waste forms and to help develop the next generation high performance waste management technologies. This work package collaborates closely with the work conducted under “Glass Ceramic – Pacific Northwest National Laboratory (PNNL) - (FT-15PN030704)” and “CCIM Test with Glass Ceramic – Idaho National Laboratory (INL) – (FT-15IN030707)”. The Los Alamos National Laboratory (LANL) is focusing on characterization, testing procedures on glass ceramics from the test matrix and melter testing to further develop and mature the glass ceramic waste form for immobilization of high level waste (HLW) raffinate stream. In Fiscal Year 2015, we are mainly working on multi-phase glass ceramic waste forms. Various characterization and testing techniques (including X-ray diffraction, transmission electron microscopy/scanning transmission electron microscopy, scanning electron microscopy, synchrotron X-ray, nano-indentation) were used to characterize and investigate the corrosion behavior of glass ceramics.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of crystalline ceramic waste form

The research conducted in this work package is to collect data in support of future development of ceramic waste forms and to help develop the next generation high performance waste management technologies. This work package collaborates closely with the work conducted under “Ceramics - Savannah River National Laboratory (SRNL) - (FT-15SR030702)” and the NEUP project “Alternative High-Performance Ceramic Waste Forms” – Alfred University (AU) – (DE-AC07-05ID14517)”. The Los Alamos National Laboratory (LANL) is focusing on characterization and testing procedure on the reference crystalline ceramics to further develop the crystalline ceramic waste form to incorporate combined HLW raffinate stream and/or TRU stream from fuels fabrication processes. In Fiscal Year 2015, we are mainly working on cold crucible induction melter (CCIM) test multi-phase crystalline ceramic waste form samples and single phase hollandite materials. Various characterization techniques (including X-ray diffraction, transmission electron microscopy, scanning electron microscopy) were used to characterize CCIM samples. For the radiation stability test, in situ radiation techniques were employed to simulate self-radiation in waste form samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Synthesis of nanodiamonds encapsulated by zeolitic imidazole framework-8 for quantum sensing applications

Nitrogen vacancy (NV)-containing nanodiamonds are widely used in quantum sensing applications due to their high sensitivity to magnetic fields, relatively low cost, and ability to be initialized, manipulated, and read out at room temperature. Quantum sensing techniques such as optically detected magnetic resonance (ODMR) and spin relaxometry have exploited the sensitivity of the NV nanodiamonds to magnetic fields to detect a range of analytes, such as pH, metal ions, and biomolecules. However, diversifying the sensing targets accessible by NV diamond quantum sensors typically requires careful engineering of the diamond surface chemistry with stimuli-responsive functional groups. Here, a simple protocol for coating NV nanodiamonds with the zeolitic imidazole framework 8 (ZIF-8), a widely used metal-organic framework, is presented. ZIF-8 is a highly porous material that has been used as a selective sensor for gasses, metal ions, and other analytes. The material is well-characterized by x-ray diffraction, transmission electron microscopy, scanning electron microscopy, x-ray photoelectron spectroscopy, and luminescence spectroscopy. Encapsulation of NV nanodiamonds with a porous scaffold such as ZIF-8 provides a promising method for improving the selectivity for the quantum sensing of various analytes. Importantly, the ZIF-8 coating does not impact the luminescence properties of the NV diamond, which is a key readout in ODMR and spin relaxometry sensing approaches. Indeed, the ODMR spectra with and without the ZIF-8 shell is nearly identical. Moreover, the ZIF-8 coating increases the longitudinal spin relaxation time of the NV nanodiamond by a factor of 4 relative to aggregated diamond, a desirable outcome for spin relaxation-based quantum sensing. Metal-organic framework composites with nanodiamonds thus are an exciting strategy for enhancing NV nanodiamond performance in applications such as quantum sensing and quantum-enhanced nuclear magnetic resonance spectroscopy.

nitrogen vacancy nanodiamond↗

Styrene-Based Elastomer Composites with Functionalized Graphene Oxide and Silica Nanofiber Fillers: Mechanical and Thermal Conductivity Properties

The mechanical and thermal conductivity properties of two composite elastomers were studied. Styrene–butadiene rubber (SBR) filled with functionalized graphene oxide (GO) and silica nanofibers, and styrene–butadiene–styrene (SBS) block copolymers filled with graphene oxide. For the SBR composites, GO fillers with two different surface functionalities were synthesized (cysteamine and dodecylamine) and dispersed in the SBR using mechanical and liquid mixing techniques. The hydrophilic cysteamine-based GO fillers were dispersed in the SBR by mechanical mixing, whereas the hydrophobic dodecylamine-based GO fillers were dispersed in the SBR by liquid mixing. Silica nanofibers (SnFs) were fabricated by electrospinning a sol–gel precursor solution. The surface chemistry of the functionalized fillers was studied in detail. The properties of the composites and the synergistic improvements between the GO and SnFs are presented. For the SBS composites, GO fillers were dispersed in the SBS elastomer at several weight percent loadings using liquid mixing. Characterization of the filler material and the composite elastomers was performed using x-ray photoelectron spectroscopy, x-ray diffraction, transmission electron microscopy, scanning electron microscopy, thermogravimetric analysis, dynamic mechanical analysis, tensile testing, nanoindentation, thermal conductivity and abrasion testing.

36 MATERIALS SCIENCE↗

Methods of analyzing microsize particulate aerosols and contaminants.

Methods for analyzing atmospheric aerosols and particulate contaminants from natural and industrial sources are briefly described. Their development was spurred by interest in cosmic dust investigations. These methods make it possible to analyze individual particles ranging in size from 0.01 to 1000 microns for elemental and mineralogical content. The described methods include transmission electron microscopy, scanning electron microscopy, electron probe microanalysis, X-ray diffraction, optical mineralogy, and density measurement.

Blanchard, M. B.↗

Endolithic algae and micrite envelope formation in Bahamian oolites as revealed by scanning electron microscopy.

Examination of Holocene Bahamian ooelites by scanning electron and light microscopy has revealed the morphology and orientation of aragonite crystals in the lamellar ooelitic envelope, and their modification by the boring activities of endolithic algae. The voids produced by these algae are found in progressive stages of being lined and filled with precipitated microcrystalline aragonite, which is similar to the process of micrite envelope formation in molluscan and other skeletal carbonate grains.

Margolis, S.↗

Chemistry and surface morphology of soil particles from Luna 20 LRL sample 22003.

Optical and scanning electron microscopy, scanning electron microprobes and energy dispersion techniques were applied in an analysis of six siliceous glass spheres, five siliceous glass-bonded agglutinates and one breccia fragment from Luna 20 sample 22003. It is theorized that local meteor impact processes might have been responsible for the formation of most of the glass spheres and that the impacts of relatively high velocity particles might have been responsible for the craters observed on the surfaces of the spheres. The concentrations of iron spherules on the surfaces of the glass spheres were generally lower than in similar Apollo 11 and 12 glass spheres.

Carter, J. L.↗

In-situ scanning electron microscopy and atomic force microscopy Young's modulus determination of indium oxide microrods for micromechanical resonator applications

Electric field induced mechanical resonances of In{sub 2}O{sub 3} microrods are studied by in-situ measurements in the chamber of a scanning electron microscope. Young's moduli of rods with different cross-sectional shapes are calculated from the resonance frequency, and a range of values between 131 and 152 GPa are obtained. A quality factor of 1180–3780 is measured from the amplitude-frequency curves, revealing the suitability of In{sub 2}O{sub 3} microrods as micromechanical resonators. The Young's modulus, E, of one of the rods is also measured from the elastic response in the force-displacement curve recorded in an atomic force microscope. E values obtained by in-situ scanning electron microscopy and by atomic force microscopy are found to differ in about 8%. The results provide data on Young's modulus of In{sub 2}O{sub 3} and confirm the suitability of in-situ scanning electron microscopy mechanical resonance measurements to investigate the elastic behavior of semiconductor microrods.

36 MATERIALS SCIENCE↗

Three-dimensional characterization of hardened paste of hydrated tricalcium silicate by serial block-face scanning electron microscopy

With the application of a three-dimensional (3D) characterization technique, serial block-face scanning electron microscopy (SBFSEM), the 3D microstructure of a hydrated cement monomineral, tricalcium silicate (C 3 S), was measured with nanoscale resolution. The 3D morphologies of anhydrous particles, hydrated products, and capillary pores were visualized. Closed and open pores were discovered inside an anhydrous particle. The size and distribution of both the anhydrous C 3 S particles and their capillary pores were analyzed quantitatively and the porosity was determined to be 9%. The distribution of pores was found to be in a good agreement with the inner and outer product model of Hu et. al., with an inner shell distance of 860 nm. Here, considering the spatial resolution of the instrument and the volume of sample measured, most pores in this experiment could be characterized as capillary pores.

3D microstructure↗

In situ investigation of ion-induced dewetting of a thin iron-oxide film on silicon by high resolution scanning electron microscopy

Using our new in situ high resolution scanning electron microscope, which is integrated into the UNILAC ion beamline at the Helmholtzzentrum fuer Schwerionenforschung (GSI) in Darmstadt, Germany, we investigated the swift heavy ion induced dewetting of a thin iron oxide layer on Si. Besides heterogeneous hole nucleation at defects and spontaneous (homogeneous) hole nucleation, we could clearly identify a dewetting mechanism, which is similar to the spinodal dewetting observed for liquid films. Instead of being due to capillary waves, it is based on a stress induced surface instability. The latter results in the formation of a wavy surface with constant dominant wave-length and increasing amplitude during ion irradiation. Dewetting sets in as soon as the wave-troughs reach the film-substrate interface. Inspection of the hole radii and rim shapes indicates that removal of the material from the hole area occurs mainly by plastic deformation at the inner boundary and ion induced viscous flow in the peripheral zone due to surface tension.

36 MATERIALS SCIENCE↗

Evidence of nonplanar field emission via secondary electron detection in near field emission scanning electron microscopy

Nonplanar field emission from electrochemically etched tungsten field emitters has been observed using near field emission scanning electron microscopy. Close-proximity field emission in adequate ultrahigh vacuum conditions was implemented to attain Fowler-Nordheim plots using typical imaging parameters. The emission radii deduced via a detailed, spherical surface field emission theory, by [Edgcombe and de Jonge, J. Phys. D 40, 4123 (2007)], reveal that our sharpest tip asperities are less than a nanometer. This yields a spatial resolution on the order of one nanometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗